• 제목/요약/키워드: SLS

검색결과 438건 처리시간 0.025초

Uniformity Improvement of SLS poly-Si TFT AMOLED

  • Park, Hye-Hyang;Lee, Ki-Yong;Kim, Kyoung-Bo;Kim, Hye-Dong;Chung, Ho-Kyoon
    • Journal of Information Display
    • /
    • 제6권3호
    • /
    • pp.22-25
    • /
    • 2005
  • In this study, we attempted to find the origin of brightness non-uniformity in SLS poly-Si TFT AMOLED. By developing a suitable SLS process with a compensation circuit, we successfully improved the non-uniformity from 40% to 1.7%. In addition, we were able to fabricate 2.2" AMOLED display using SLS poly-Si.

The Characterization of Poly-Si Thin Film Transistor Crystallized by a New Alignment SLS Process

  • Lee, S.J.;Yang, J.Y.;Hwang, K.S.;Yang, M.S.;Kang, I.B.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.16-19
    • /
    • 2007
  • In this paper, we present work that has been carried out using the SLS process to control grain boundary(GB) location in TFT channel region and it is possible to locate the GB at the same location in the channel region of each TFT. We fabricated TFT by applying a new alignment SLS process and compared the TFT characteristics with a normal SLS method and the grain boundary location controlled SLS method. Also, we have analyzed degradation phenomena under hot carrier stress conditions for n-type LDD MOSFETs.

  • PDF

SLS(Solid-Liquid-Solid) 성장기구에 의한 탄화규소 나노튜브의 성장 (Growth of SiC Nanotube by SLS (Solid-Liquid-Solid) Growth Mechanism)

  • 노대호;김재수;변동진;양재웅;김나리
    • 한국재료학회지
    • /
    • 제14권2호
    • /
    • pp.83-89
    • /
    • 2004
  • SiC nanotubes were synthesized by SLS growth mechanism using various metal catalysts. Synthesized nanotubes had mean diameters of 20~50 nm and several $\mu\textrm{m}$ length. The kind of catalysts affected microstructures of SiC nanotubes by different diffusion routes. These differences are attributed to catalysts' physical properties and relative activities to the graphite substrate. Fe acted as a good catalyst of SLS growth mechanism. But in case of Ni, SiC nanotubes grew slowly. Optical property was measured by photoluminescence measurement. Relatively broad peak was obtained and mean peak positioned at about 430 nm. This result was the same as other nanocrystalline SiC materials, but was different from the results of bulk SiC probably due to quantum confinement effect and defect in the grown SiC nanotube.

The Scanning Laser Source Technique for Detection of Surface-Breaking and Subsurface Defect

  • Sohn, Young-Hoon;Krishnaswamy, Sridhar
    • 비파괴검사학회지
    • /
    • 제27권3호
    • /
    • pp.246-254
    • /
    • 2007
  • The scanning laser source (SLS) technique is a promising new laser ultrasonic tool for the detection of small surface-breaking defects. The SLS approach is based on monitoring the changes in laser-generated ultrasound as a laser source is scanned over a defect. Changes in amplitude and frequency content are observed for ultrasound generated by the laser over uniform and defective areas. The SLS technique uses a point or a short line-focused high-power laser beam which is swept across the test specimen surface and passes over surface-breaking or subsurface flaws. The ultrasonic signal that arrives at the Rayleigh wave speed is monitored as the SLS is scanned. It is found that the amplitude and frequency of the measured ultrasonic signal have specific variations when the laser source approaches, passes over and moves behind the defect. In this paper, the setup for SLS experiments with full B-scan capability is described and SLS signatures from small surface-breaking and subsurface flaws are discussed using a point or short line focused laser source.

A rare case of Sjogren-Larsson syndrome with recurrent pneumonia and asthma

  • Tavasoli, Azita;Sayyahfar, Shirin;Behnam, Babak
    • Clinical and Experimental Pediatrics
    • /
    • 제59권6호
    • /
    • pp.276-279
    • /
    • 2016
  • Sjogren-Larsson syndrome (SLS) is a rare autosomal recessive neurocutaneous disorder with worldwide incidence of 0.4 per 100,000 people. It is characterized by the triad of congenital ichthyosis, spastic diplegia or quadriplegia, and mental retardation. Herein we report a 2-year-old male child with SLS, asthma, and recurrent pneumonia. SLS was confirmed by a molecular genetics study that revealed a deletion mutation in the ALDH3A2 gene. An ALDH3A2 gene mutation results in dysfunction of the microsomal enzyme fatty aldehyde dehydrogenase and impaired metabolism and accumulation of leukotriene B4, which is a key molecule and a pro-inflammatory mediator in developing allergic diseases, especially asthma. An increased level of leukotriene B4 has been reported in SLS patients. As far as we are aware, this is the first report of SLS associated with asthma and recurrent pneumonia. In conclusion, pediatricians should be aware of and evaluate patients with SLS for possible associated asthma and allergic disorders.

SLS 공정에서 최적 공정 조건 도출을 위한 실험적 연구 (An Experimental Study for Drawing of Optimal Process Condition in the SLS Process)

  • 배성우;유성연;김동수
    • 한국생산제조학회지
    • /
    • 제21권3호
    • /
    • pp.516-524
    • /
    • 2012
  • Selective Laser Sintering(SLS) system consists of various element technologies. Main components of the system include a position control system, a speed control system of the roller, and nitrogen atmosphere furtherance for the powdered sintering. Other systems which make the core of the SLS system are build room and the feed room for powder epitaxial, a temperature control system, and a scan path generator for the laser. The powder material for laser sintering is necessary to produce prototypes in Solid Freeform Fabrication(SFF) based on SLS process. This powder material is sintered in powder room using $CO_2$ laser after spreading evenly using roller to reproduce mold via SFF. This study addresses an SFF system by using the SLS process which applies single laser system to enable manufacturing of 3D shape. And to evaluate applicability of the single laser system, experiments were conducted with optimal fabricating process.

Development of Thin and Lightweight Bulletproof Windows Using Strengthened SLS Glass by Ion Exchange

  • Shim, Gyu-In;Kim, Seong-Hwan;Ahn, Deok-Lae;Park, Jong-Kyoo;Choi, Se-Young
    • 한국세라믹학회지
    • /
    • 제52권2호
    • /
    • pp.123-127
    • /
    • 2015
  • Soda-lime silicate (SLS) glass was strengthened by ion exchange for application of thin and lightweight bulletproof windows. The optimal conditions for ion exchanged SLS glass (thickness of 3 and 10 mm) at $480^{\circ}C$ were 10 and 17 min, respectively. The Vickers hardness values of the strengthened SLS glass samples with thicknesses of 3 and 10 mm were $5.9{\pm}0.22$ and $6.7{\pm}0.17GPa$, respectively, which values were about 22% higher than those of parent SLS glass. By laminating a multilayer defense film and polycarbonate sheet with ion exchanged SLS glass, we were able to make a thin and lightweight bulletproof window (24.25 mm, 4.57 kg, $50.06kg/m^2$, $V_{50}$ 901.8 m/s). As a result, the thickness of the bulletproof window was decreased by about 39% from 40 to 24.25 mm. The light transmittance in the visible range satisfied the standard (over 76%) for bulletproof windows.

Comparison of difference in muscle activity ratio, ground reaction force and knee valgus angle during single leg squat and landing according to dynamic taping

  • Ha, Tae-Won;Park, Sam-Ho;Lee, Myung-Mo
    • Physical Therapy Rehabilitation Science
    • /
    • 제9권4호
    • /
    • pp.281-286
    • /
    • 2020
  • Objective: This study examined the effects of dynamic tape applied to the patellofemoral joint on the knee valgus angle, muscle activity, and ground reaction force during a single leg squat (SLS) and single leg landing (SLL). Design: Cross-sectional study. Methods: Twenty-four subjects (11 male, 13 female) who met the inclusion criteria were screened by the knee palpation and patella compression tests. First, the knee valgus angle and muscle activity during SLS were measured. Second, the knee valgus angle and ground reaction force during SLL were measured. For the intervention, a patella joint loop using dynamic tape was used. The knee valgus angle, muscle activities in SLS and SLL after the intervention, and the ground reaction force were measured in the same way. A paired t-test was used to examine the difference between before and after the intervention. Results: The knee valgus angle showed a statistically significant improvement after dynamic taping application in SLS and SLL (p<0.05). The differences in muscle activity of the VL/VMO and ground reaction forces were not statistically significant after dynamic taping application in SLS and SLL. Conclusions: This study showed that dynamic taping applied around the patellofemoral joint was effective in improving the knee valgus angle in SLS and SLL and had a reduced risk of secondary injury during sports activity.

세치제내 SLS함유에 따른 타액과 세균변화 (The Change of Salivary and Oral Bacteria Amount by Composition of SLS Contents of Toothpaste)

  • 심연수;정미애;정상희
    • 한국산학기술학회논문지
    • /
    • 제11권9호
    • /
    • pp.3341-3346
    • /
    • 2010
  • 이 연구는 세치제 내 함유되어 있는 SLS의 함유여부에 따라 구강 내 타액과 세균수의 변화정도를 비교분석하여 향후 보다 양질의 세치제 개발을 위한 기초자료를 제공하고자 하였다. SLS의 함유량을 2.2%와 0.0%의 세치제를 제조하여 각각 30명으로 구성된 두 집단의 실험대상자에게 4주간 사용하게 하고 실험 전 후의 타액과 구강 내 세균 수의 변화 차이를 보았다. 연구결과 SLS의 배합여부는 타액, 세균수의 변화에 현저한 차이를 보이지 않았다. 또한 SLS 배합여부는 타액량과 구강 내 세균수의 관련성이 없는 결과를 보였다. 하지만 실험대상자들이 사용한 세치제에 대한 만족도 조사에서는 SLS가 함유되지 않은 그룹 보다 SLS가 함유된 그룹에서 만족도가 현저하게 높은 것으로 나타났다. 만일 SLS가 선호감 때문에 이용되고 있다면 SLS의 적정 함유량에 대한 구체적 개선방안을 모색하여 할 것이다.

국부상의치의 전해연마에 따른 SLS 3D 프린터의 적합성 평가 (Assessment of the fit of partial frame fabricated by SLS 3D printer)

  • 박영대;강월
    • 한국치위생학회지
    • /
    • 제19권6호
    • /
    • pp.1067-1075
    • /
    • 2019
  • Objectives: The present study aimed to compare the accuracy of removable partial denture (RPD) frameworks fabricated by selective laser sintering (SLS) before and after electropolishing. Methods: A partially edentulous mandibular model was used as the working model. Scanning of the model was performed using a dental scanner. The framework was designed using CAD software. The metal framework was formed using an SLS 3D printer. 3D scans of the two fabricated prototypes produced before and after electropolishing were overlapped with reference data. The fit was calculated based on Root Mean Square (RMS). Fabrication accuracy was verified using the paired t-test to compare the discrepancy before and after electropolishing. Results: The mean (SD) values of RMS before and after electropolishing were 126.6 (34.19) and 75.86 (21.36), respectively. There was a statistically significant difference before and after electropolishing (p<0.05). Conclusions: Metal frameworks made with SLS 3D printers showed clinically acceptable fit after electropolishing.