• 제목/요약/키워드: SLF(Short Line Fault)

검색결과 9건 처리시간 0.021초

Development of a 170kV 50kA Capacitorless Gas Circuit Breaker

  • Park, K. Y.;K. D. Song;Y. H. Oh;W. P. Song;J. H. Kang;Park, S. W.
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권3호
    • /
    • pp.73-76
    • /
    • 2003
  • In modern EHV (Extra High Voltage) class GCBs (Gas Circuit Breakers), the interruption capability for SLF (Short Line Fault) is one of the most important aspects of performance required for GCBs. Up to now, the SLF interruption capability of EHV class GCBs was partially assisted by the adoption of capacitors able to decrease the dV/dt of the TRV (Transient Recovery Voltage), particularly the TRV on the line side. This paper describes the technique to increase the SLF interruption capability of EHV class GCBs as well as the procedure to develop capacitorless l70kV 50kA GCB.

Simplified Synthetic Testing Facility with Modified TRV Circuit

  • Chong, Jin-Kyo;Lee, Kyung Seob;Lee, Chang-Hoon;Kim, Gyu-Tak
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.881-885
    • /
    • 2018
  • In order to develop a gas circuit breaker (GCB), the breaking performance of the short line fault (SLF) should be prioritized over that of the breaker terminal fault (BTF). In brief, it is necessary to evaluate the thermal characteristics of the insulating gas that is filled in a GCB. In the process of developing a GCB, many companies use the simplified synthetic testing facility (SSTF).In order to evaluate the SLF breaking performance of a GCB with a long minimum arcing time, a modifications to the conventional SSTF was proposed. In this study, we developed the SSTF with a modified transient recovery voltage circuit. The performance of the newly developed SSTF was verified by an $L_{90}$ breaking performance test on a rating combination of 170 kV, 50 kA, and 60 Hz.

345kV 고장전류 저감을 위한 한류리액터 설치시 차단기 TRV(근거리 고장시) 검토 (A Study on the TRV(SLF) of Circuit Breakers According to Install Current Limit Reactors)

  • 박흥석;곽주식;주형준;유희영;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.371-373
    • /
    • 2005
  • An enhancement for a transmission and substation equipment in power system make the system impedance to be lower. In principle, if the system impedance become low, system stability will be better, but the fault current become very higher. It is a very big problem for CB operating. As a fact of CB operating performance, high amplitude of the fault current may cause CB operation failure because of exceeding standard value in TRV. So we simulated TRV by using the EMTP. Generally there are two types of TRV in actual power system. One is short line fault, the other is bus terminal fault. In this paper, we simulated the TRv at short line fault as installed current limit reactors to reduce fault current in 345kV ultra-high voltage system. Short line fault is caused from single line fault in transmission line.

  • PDF

복합소호형 가스 차단기의 SLF 차단 성능 해석 (Analysis of SLF Interruption Performance in self-blast Gas Circuit Breaker)

  • 박진근;안희섭;최종웅;김영근;조해용
    • 한국기계가공학회지
    • /
    • 제19권9호
    • /
    • pp.24-32
    • /
    • 2020
  • A self-blast type gas circuit breaker has been studied in this study to improve efficiency of interrupting performance of short line fault(SLF). Hot gas flows of gas circuit breaker have been simulated to evaluate interruption performance using CFD. Design parameters such as various types of expansion chamber and nozzles are suggested by using simulation results. Simulated results and experimental ones are compared with previous (ones that of in under development and with capacitor) GCB. Modified new shape of an expansion chamber and nozzle has been suggested to improve the efficiency of gas flow and to provide guidelines for designing self-blast breaker with a higher interruption capability.

Analysis of SLF Interruption Performance of Self-Blast Circuit Breaker by Means of CFD Calculation

  • Kim, Hong-Kyu;Chong, Jin-Kyo;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.254-258
    • /
    • 2014
  • This paper presents the performance analysis results of a short line fault interruption of a gas circuit breaker, particularly a self-blast type breaker. Hot gas flow analysis was carried out using a CFD calculation combined with the arc model and nozzle ablation model. To evaluate the interruption performance, the index function was defined using the pressure in the heating chamber and the density above the arc region. The simulation and test results showed that the gas flow field and suitable choice of an interruption performance index can be used to predict the interruption characteristics and provide guidelines for designing self-blast breakers with a higher interruption capability.

전류영점 영역에서 파퍼식 SF6 가스차단기의 아크 컨덕턴스에 관한 연구 (A Study on Arc Conductance of Puffer Type SF6 GCB at Current Zero Period)

  • 정진교;송기동;이우영;김규탁
    • 전기학회논문지
    • /
    • 제59권2호
    • /
    • pp.328-332
    • /
    • 2010
  • The SLF(Short Line Fault) breaking capability test for high voltage class $SF_6$ GCB(Gas Circuit Breaker) was conducted. Simplified LC resonant circuit test facility was used for SLF breaking test. During test, Test current was measured by Rogwski coil and arc voltage was measured by voltage divider. Arc conductance was calculated by using these test results before 200ns at current zero. Critical arc conductance value at rated voltage 145kV class is about 2.3mS regardless of breaking current magnitude and arc conductance value at rated voltage 170kV class is about 2.6mS.

Investigation of SLF Interruption Capability of Gas Circuit Breaker with CFD and a Mathematical Arc Model

  • Cho, Yong-Sung;Kim, Hong-Kyu;Chong, Jin-Kyo;Lee, Woo-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.354-358
    • /
    • 2013
  • This paper discusses the analysis of arc conductance in a gas circuit breaker (GCB) during current interruption process and the investigation method of the interruption capability. There are some limitations in the application of the computational fluid dynamics (CFD) for the implementation of an arc model around the current zero, despite the fact that it gives good results for the high-current phase arc. In this study, we improved the accuracy in the analysis of the interruption performance by attempting the method using CFD and a mathematical arc model. The arc conductance at 200 ns before current zero (G-200ns) is selected as the indicator to predict the current interruption of the Short Line Fault (SLF). Finally, the proposed method is verified by applying to the actual circuit breakers which have different interruption performances.

한양대학교 간이차단 합성시험설비구축 (HY Simplified Synthetic Test Facility)

  • 장용무;황률;김철호;이방욱;구자윤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.220-220
    • /
    • 2009
  • We are developing of the evaluation technique and system for testing the performance of circuit breaker using Simplified Synthetic circuit. This facility specification is up to 90[kApeak] and up to 300[kVpeak]. It is possible to verify the interrupting capability by using low-energy and reduce the development period and the cost.

  • PDF

파퍼실린더 직경이 초고압 GCB의 열적 차단성능에 미치는 영향 (Influence of Diameter of Puffer Cylinder on Thermal Interruption Capability of EHV GCB)

  • 오연호;송기동;최영길;이병윤;박경엽;신영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.37-39
    • /
    • 1998
  • This paper presents the pressure-rise of the puffer cylinder in a model gas circuit breaker and the analyzed results of thermal interruption capability in SLF(short line fault) to the diameter of the puffer cylinder. This paper can be applied to the design of the EHV interrupter.

  • PDF