• Title/Summary/Keyword: SIP 말뚝

Search Result 24, Processing Time 0.025 seconds

Suggestion of Evaluation Formula for Skin Resistance of SIP (SIP말뚝의 주면저항력 예측 모델 제안)

  • Chung, Hyung-Sik;Lim, Hae-Sig;Kim, Jung-Soo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.4 no.1
    • /
    • pp.59-66
    • /
    • 2003
  • The environmental problem due to the pile driving, the use of low noise-vibration auger-drilled pilling is increasing to solve noise and vibration problem in pilling. Therefore, in Korea, SIP (Soil-Cement Injected Precast Pile) method is mainly used as auger-drilled pilling. However, a proper bearing capacity evaluation formula has not been suggested, yet. In order to improve and supplement this situation, direct shear tests between SIP pile skin interface and soil were executed under various conditions. Through the analysis of test results, skin resistance characteristics of SIP were investigated thoroughly. Also, the nonlinear unit skin resistance capacity model and relative parameters evaluation formula with SM, SC soil were suggested.

  • PDF

Investigation of Characteristics and Suggestion of Evaluation Formulae for Skin Resistance of SIP (SIP 말뚝의 주면저항력 특성 고찰 및 산정식 제안)

  • Lim, Hae-Sig;Park, Yong-Boo;Park, Jong-Bae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.3 no.2
    • /
    • pp.15-21
    • /
    • 2002
  • Because of the environmental problem during the pile driving, the use of low noise-vibration auger-drilled pilling is increasing to solve noise and vibration problem in pilling. In Korea, SIP (Soil-Cement Injected Precast Pile) method is mainly used as auger-drilled pilling. But, a proper bearing capacity evaluation formula has not been suggested, yet. To improve and supplement this situation, direct shear tests between SIP pile skin interface and soil were executed under various conditions. Through the analysis of test results, skin resistance characteristics of SIP were investigated thoroughly. Also, the maximum unit skin resistance capacity evaluation formulae on SM, SC soil was suggested.

  • PDF

Estimation of Bearing Capacity of SIP Pile Installed by Improved Criteria (개선된 기준으로 시공된 SIP 말뚝의 지지력 평가에 관한 연구)

  • Park, Jong-Bae;Kim, Jung-Soo;Lim, Hae-Sik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.3
    • /
    • pp.5-15
    • /
    • 2004
  • SIP has been widely used as a low noise and vibration piling method in Korea. But the quality control of SIP was not properly settled down and field workers did not fully understand the principle of SIP method. So not a less troubles were raised at construction site and bearing capacity was not fully mobilized. To settle these problems, Korea National Housing Corporation amended the construction and load test criteria of SIP in 2002. After load tests on the SIPs installed in field according to the new criteria, we found that the bearing capacity in field vs the design load ratio increased and bearing characteristics was enhanced than that installed by the former criteria. To consider the enhanced bearing characteristics in the pile design and determine the adequate design criteria, this paper analyzed the accuracy of design criterion which were commonly used in Korea comparing with the load test results. Analysis result shows that Meyerhof criteria(1976) properly simulates the bearing capacity of SIP installed by the new construction and load test criteria.

  • PDF

SIP시공말뚝의 지지력특성

  • 이명한;윤성진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1993.04a
    • /
    • pp.91-115
    • /
    • 1993
  • 최근 환경문제에 대한 사회적 관심이 고조됨에 따라 말뚝항타로 인한 지반진동, 소음 등이 각종 건설현장에서 심각한 문제점으로 대두되고 있다. 지반을 굴착하고 cement paste를 주입한후 기성말뚝을 삽입하는 SIP공법은 이러한 건설환경 여건의 변화에 부응하여 그 적용이 급속히 증대되고 있다. 그러나 국내에서 SIP공법으로 시공딘 말뚝의 재하시험 결과는 각종 문헌에서 제시학 있는 지지력 산정공식들과는 상이한 특성을 나타내 주고있다. 또한 말뚝의 품질관리를 위한 시험결과는 상당한 지지력 미달현상이 발생학 있는 것으로 나타나고 있어 본 공법에 대한 지지력 특성이 규명되어야 할 필요가 있다. 본 논문에서는 국내에서 시공된 사례들을 중심으로 SIP공법의 지지력 특성을 분석하여 보았다.

  • PDF

A Study on the Skin Friction Characteristics of SIP and Numerical Model of the Interface Between SIP and Soils (SIP말뚝의 주면마찰특성 및 주면 경계요소의 수치모델에 관한 연구)

  • 천병식;임해식
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.247-254
    • /
    • 2003
  • While the interests in the environmental problem during the construction are increasing, the use of low noise-vibration auger-drilled pilling is increasing to solve noise and vibration problem in pilling. Therefore, in Korea, SIP (Soil-Cement Injected Precast Pile) method is mainly used as auger-drilled pilling. However, there is no proper design criteria compatible with the ground condition of Korea, so which is most wanted. To improve and supplement this situation, direct shear tests for the friction between SIP pile skin interface and soil were executed on various conditions. Through the analysis of test results, skin friction characteristics of SIP were investigated thoroughly Also, hyperbolic model parameter fomulas which describe the friction behavior and the new non-linear unit skin friction capacity model with SM, SC soil were suggested.

Bearing Capacity Characteristics of SIP Piles (SIP 공법의 지지력 특성에 관한 연구)

  • 박종배;김정수;정형식
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.1
    • /
    • pp.51-60
    • /
    • 2003
  • As piling works in urban area are increasing, SIP which has low noise & vibration piling method takes the place of driven pile which has good bearing charateristics and is economical. Although SIP has been used far more than 15 years and it's use is increasing year by year, accurate analysis of bearing mechanism of SIP is not enough. So the design of SIP is much more conservative than driven pile. This paper is aimed at analysing the bearing charateristics of 103 SIPs constructed in Korea to give rational design criteria. Research result shows that bearing capacity of SIP is 40% lower than that of driven pile and conservative Meyerhof(20$\bar{N}_b'A_b$) method produced closer result to load test results than any other design method. And this result shows that in order to use optimised design criteria for the economical SIP design, quality control criteria must be settled down to produce high bearing capacity.

Analysis and Countermeasures for the Problem Arise of the Spot Installation Pile Using SIP (SIP공법 시공시 문제점 발생 요인 분석 및 대응 방안)

  • Park, Jong-Hyuk;Park, Hong-Tae;Jeon, Yong-Bae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.3287-3295
    • /
    • 2011
  • Currently in construction Soil-cement Injected Precast pile of buried pile method are in wide use. But deterioration in pile quality and faulty construction can be often found these days because of problems arise in the construction field. For this study, survey was carried out by targeting construction engineers working in the field in order to identify the types and the causes of problems arise based on SIP(Soil-cement Injected Precast) method. By analyzing the causes of problems arise, countermeasures could be presented. The data and the analysis presented in the study could be effectively used for minimizing problems arise in future during SIP method construction.

PHC말뚝의 경제성에 대한 연구

  • 임성한
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1992.06a
    • /
    • pp.57-86
    • /
    • 1992
  • 본 연구에서는 기존의 PC말뚝과 PHC말뚝의 시공성과 지지력에 대한 비교확인 시험의 결과를 근거로 하여 PHC말뚝의 시공상의 장점, 특성 및 경제성을 파악하였으며, SIP공법에 의하여 PHC말뚝을 사용시 기존 PC말뚝이나 강관말뚝보다 경제성이 우수함을 확인하였다. 또한 PHC말뚝은 압축강도와 지지혁이 기존 PC말뚝보다 높을 뿐만아니라 강관말뚝과 같이 용접이음이 가능하고 말뚝의 심도가 깊은 경우에도 강관말뚝과의 대체시공이 가능하여 PHC말뚝의 성능을 극대화할 수 있는 적절한 항타장비를 사용하는 경우에는 혁신적인 원가절감이 가능함을 확인할 수 있다.

  • PDF

A Study on the Characteristics of Bearing Capacity for SIP Piles in Domestic Areas (국내 SIP 말뚝의 지지력 특성에 관한 연구)

  • Lee, Song;Park, Jun-Hong;Park, Joong-Bai;Kim, Tae-Hwoon
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.319-327
    • /
    • 2002
  • In this research, problems of recent design methods and their improvement for SIP(Soil-Cement Injected precast Pile) in domestic areas were studied by using the properties of load-settlement curves and bearing capacity from field loading tests. Elastic and plastic settlement for total settlement in each loading step of loading tests conducted in domestic areas has been shown to have a tendency. From this tendency and bearing capacity determined by loading tests, it could be ascertained that empirical chart could be an assistant tool in SIP design. It was shown that SIP design using N-value in domestic area with soil condition of granitic type resulted in very conservative hearing capacity. On the other hands, in soil with unfitted geological conditions, the design could be insecure. Also, we could ascertain that Meyerhof's bearing capacity using modified N-value on the tip part of pile was more applicable than recent design method where tip bearing capacity was 20NA$_p$ N-value limited to 50. These results showed that modified design method could be more economic than those in the past because it used pile's bearing capacity unto tolerable load of pile material.