• Title/Summary/Keyword: SI units

Search Result 170, Processing Time 0.024 seconds

Proficiency Test of Water Flow Rate for Measurement Equivalence Among KOLAS Accredited Laboratories (KOLAS 교정기관의 측정동등성 확립을 위한 물유량 숙련도 시험)

  • Chun, Sejong;Yoon, Byung-Ro;Kim, Soo-Jin
    • Transactions of the KSME C: Technology and Education
    • /
    • v.5 no.2
    • /
    • pp.105-113
    • /
    • 2017
  • KOLAS (KOrea Laboratory Accreditation Scheme) belongs to APLAC (Asia Pacific Laboratory Accreditation Cooperation). KOLAS manages the accreditation scheme for measurement traceability to SI units. As per June 2016, there are 22 KOLAS laboratories for liquid flow metering. Among them, 12 laboratories participated in the proficiency test (PM2015-08) for water flow metering, organized by KASTO (Korea Association of Standards and Testing Organizations). This proficiency test was performed with three kinds of flow ranges ($3.6m^3/h{\sim}12m^3/h$, $40m^3/h{\sim}80m^3/h$, $40m^3/h{\sim}200m^3/h$) considering the CMC (calibration and measurement capability) of the participating laboratories. The purpose of the proficiency test was to find out measurement equivalence of the CMC's between each participating laboratory and the reference testing laboratory (KRISS). The measurement equivalence was tested by the number of equivalence ($E_n$). If ${\mid}E_n{\mid}$ < 1, the measurement equivalence was established. All the participating laboratories passed this proficiency test.

Process Modeling System of a Combined Cycle Plant for Steady State Simulation with Model Based Approach (수학적 모델링 방법에 기초한 복합발전 공정의 정상상태 모사시스템 개발)

  • Kim, Shin Hyuk;Hwang, Lee Si;Joo, Yong Jin;Lee, Sang Uk;Shon, Byung Mo;Oh, Min
    • Korean Chemical Engineering Research
    • /
    • v.53 no.5
    • /
    • pp.545-552
    • /
    • 2015
  • Process modeling and simulation is a powerful methodology to quantitatively predict the change of process variables when operating and design conditions are changed. In this study, considering drawbacks of currently used process simulator for combined cycle plants, we developed process modeling system equipped with an ease of use and flexibility for model development. For this purpose, the analysis of combined cycle processes was carried out and consequently, mathematical models and libraries were developed. Furthermore, in view of the fact that the level of the abstraction of process models depends on the purpose of simulation as well as the available data, simple and rigorous models were also developed for some important units. In use of reference combined plant, we executed process simulation using the developed modeling system and the comparison was made between the results of simulation and the reference data. Less than 1% marginal error was identified and we concluded that the modeling system can be applied for commercial combined cycle processes.

A Study on the Energy Consumption Characteristics for Use and Operation Period in Office Buildings (업무용 건물의 용도 및 운전 기간별 에너지 소비 특성 연구)

  • Park, Byung Hun;Kim, Si Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.11
    • /
    • pp.605-611
    • /
    • 2017
  • The purpose of this study is to calculate the energy consumption rate based on data regarding energy use in office buildings, and to confirm the general characteristics of energy consumption. The energy consumption rate of the building is calculated by dividing the energy consumption by the floor area. The energy consumption rate of small-sized office buildings was calculated as $101.48{\sim}201.55kWh/m^2{\cdot}year$ and in the case of medium-sized buildings, the range was $92.77{\sim}177.89kWh/m^2{\cdot}year$. In the case of small buildings, it was found that the energy consumption was $73.24kWh/m^2{\cdot}year$ in electronic device, $34.31kWh/m^2{\cdot}year$ in hot water supply, and $18.37kWh/m^2{\cdot}year$ in heating. In the case of medium-sized buildings, electronic devices was $73.08kWh/m^2{\cdot}year$, lighting was $18.35kWh/m^2{\cdot}year$ and heating, $15.37kWh/m^2{\cdot}year$. In all of the study buildings, the peak heating energy use was observed from 8:00 a.m. to 10:00 a.m during the winter, and the peak power management was required. Energy use at and around the midnight hour is confirmed to be 40~60% of weekly working hours, so it is necessary to manage power use at night time as well as during the day. In order to improve the accuracy of future studies, it is necessary to make efforts to secure the data with standardized energy measuring units for the various type of buildings.

Hydrolysis of Sucrose by Invertase Entrapped in Calcium Alginate Gel (칼슘 알지네이트 젤에 고정화시킨 Invertase에 의한 설탕의 가수분해)

  • Uhm, Tai-Boong;Hong, Jai-Sik;Byun, Si-Myung
    • Applied Biological Chemistry
    • /
    • v.27 no.2
    • /
    • pp.112-118
    • /
    • 1984
  • Inverase was entrapped in calcium alginate gel. The immobilized beads had excellent uniform size and configuration. To screen the optimal conditions possessing high enzyme activity, effects of sodium alginate concentration, $CaCl_2$ concentration, and the incubation time of beads in $CaCl_2$ solution during the immobilization procedure were investigated. Immobilized beads prepared from the optimal conditions had 18.8 units per ml of gel, which is equivalent to 68% of the activity of soluble enzyme. Several kinetic parameters were determined: Km value. 143 mM; optimum pH, 4.5; optimum temperature, $50^{\circ}C$. Enzyme loading capacity was 150 mg per 20 ml gel. No significant decrease in sugar conversion was observed during the column operation for 6 days.

  • PDF

Development and validation of the Korean Nursing Delirium Scale (한국어판 간호 섬망 선별 도구 개발 및 검증)

  • Kim, Kyoung-Nam;Kim, Cheol-Ho;Kim, Kwang-Il;Yoo, Hyun-Jung;Park, Si-Young;Park, Yeon-Hwan
    • Journal of Korean Academy of Nursing
    • /
    • v.42 no.3
    • /
    • pp.414-423
    • /
    • 2012
  • Purpose: The aims of this study were to develop and test the validity of the Korean Nursing Delirium Scale (Nu-DESC) for older patients in hospital. Methods: The Korean Nu-DESC was developed based on the Nu-DESC (Gaudreau, 2005), and revised according to nursing records related to signs and symptoms of older patients with delirium (n=361) and the results of a pilot study (n=42) in one general hospital. To test the validity of the Korean Nu-DESC, 75 older patients whom nurses suspected of delirium from 731 older patients from 12 nursing units were assessed by bedside nurses using the Korean Nu-DESC. A Receiver Operating Characteristic Curve of the Korean Nu-DESC was constructed with an accompanying Area Under the Curve (AUC). Results: Specific examples such as irritable, kidding, sleeping tendency, which were observed by bedside nurses in Korea, were identified in the five features of signs and symptoms of delirium in the instrument. The Korean Nu-DESC was psycho-metrically valid and had a sensitivity and specificity of .81-.76 and .97-.73, respectively. The AUC were .89, .74. Conclusion: Results of this study indicate that the Korean Nu-DESC is well-suited for widespread clinical use in busy inpatients settings and shows promise as a research instrument.

The effect of photodynamic therapy on Aggregatibacter actinomycetemcomitans attached to surface-modified titanium

  • Cho, Kyungwon;Lee, Si Young;Chang, Beom-Seok;Um, Heung-Sik;Lee, Jae-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.2
    • /
    • pp.38-45
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the effect of photodynamic therapy (PDT) using erythrosine and a green light emitting diode (LED) light source on biofilms of Aggregatibacter actinomycetemcomitans attached to resorbable blasted media (RBM) and sandblasted, large-grit, acid-etched (SLA) titanium surfaces in vitro. Methods: RBM and SLA disks were subdivided into four groups, including one control group and three test groups (referred to as E0, E30, E60), in order to evaluate the effect of PDT on each surface. The E0 group was put into $500{\mu}L$ of $20{\mu}M$ erythrosine for 60 seconds without irradiation, the E30 group was put into erythrosine for 60 seconds and was then irradiated with a LED for 30 seconds, and the E60 group was put into erythrosine for 60 seconds and then irradiated with a LED for 60 seconds. After PDT, sonication was performed in order to detach the bacteria, the plates were incubated under anaerobic conditions on brucella blood agar plates for 72 hours at $37^{\circ}C$, and the number of colony-forming units (CFUs) was determined. Results: Significant differences were found between the control group and the E30 and E60 groups (P<0.05). A significantly lower quantity of CFU/mL was found in the E30 and E60 groups on both titanium disk surfaces. In confocal scanning laser microscopy images, increased bacterial death was observed when disks were irradiated for a longer period of time. Conclusions: These findings suggest that PDT using erythrosine and a green LED is effective in reducing the viability of A. actinomycetemcomitans attached to surface-modified titanium in vitro.

Mechanism Improvement of the Heat Exchanger for the Thermal Efficiency Increase of Hot Air Heater (온풍난방기의 열효율 증대를 위한 열교환기 구조개선)

  • Kang, Geum-Choon;Kang, Yoen-Ku;Ryou, Young-Sun;Kim, Young-Joong;Lee, Si-Young;Paek, Yee
    • Journal of Biosystems Engineering
    • /
    • v.34 no.5
    • /
    • pp.363-370
    • /
    • 2009
  • Hot air heater with light oil combustion is used as the most common heater for greenhouse heating in the winter season. Hot air heaters of 256,246 units have been supplied as main greenhouse heating equipment until 2008 and greenhouse heating cost has reached to 620 billions won in Korea. In order to improve the thermal efficiency of the hot air heater and to reduce the expenses for greenhouse heating, prototype hot air heater was manufactured and tested in this experiment. The heat exchanger of tested prototype hot air heater was circular and hexagonal pipe type and inline and stagger arrangement type. Capacity of the heating was 43,062 kJ/h and total heat transfer area of the heat exchanger was $10.728\;m^2$. According to the performance test, it could supply heat of 38,240 to 35,100 kJ/h depending on the fan motor speed of 1,740~1,220 rpm, respectively. Thermal efficiency of hot air heater was 87.0% to 80.8% in the same conditions. As a result, thermal efficiency of hot air heater with hexagonal pipe-stagger arrangement heat exchanger developed in this study was higher 10.2% than that of conventional hot air heater and heating energy saving rate of 14.3% increased.

A Transaction Scheme for Managing Mobile Units in Wireless Environments: A Case of Airport Safety Control (무선환경에서의 이동객체 관리를 위한 통제기법: 공항 안전통제 업무를 중심으로)

  • Kim, Yong-Jae;Ahn, Hyun-Sup;Lee, Seog-Jun;Hyun, Doo-Woon;Choi, Yong-Goo;Lee, Sang-Won
    • Information Systems Review
    • /
    • v.10 no.2
    • /
    • pp.309-327
    • /
    • 2008
  • This research is a byproduct of a project initiated by a major airport in Korea. The airport aimed to enhance airside safety and weighed a few IT options that may strengthen its current safety practices. In order to satisfy requirements unique to the airport and to inherit existing legacy systems, a PCS-based mobile database system was proposed. We first discuss technical aspects of the system as well as design issues in mobile systems before we compare two specific alternatives for transactional service handoff. A simulation study comparing two types of coordination follows before we present a scheme that manages transaction processing and locating service in mobile environments. Finally, we discuss the limitations of the scheme from the perspectives of the airport in question along with other research issues.

Development of Primary Standard Gas Mixtures of Fourteen Volatile Organic Compounds in Hazardous Air Pollutants for Accurate Ambient Measurements in Korea (at 1 μmol/mol Levels) (유해대기오염물질 중 14종의 휘발성유기화합물 1차 표준가스개발 (1 μmol/mol 수준))

  • Kang, Ji Hwan;Kim, Young Doo;Kim, Mi Eon;Lee, Jinhong;Lee, Sangil
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.2
    • /
    • pp.331-341
    • /
    • 2018
  • Hazardous air pollutants(HAPs) in the atmosphere are regulated as major air pollutants in Korea by the Air Pollution Control Act. In order to manage and control HAPs, accurate standards, which are traceable to the International System of Units(SI), are required. In this study, primary standard gas mixtures(PSMs) of volatile organic compounds(VOCs) which are specified as HAPs were developed at $1{\mu}mol/mol$ levels. The selected fourteen VOCs include Benzene, Toluene, Ethylbenzene, m-Xylene, Styrene, o-Xylene, Chloroform, 1,1,2-Trichloroethane, Trichloroethylene, Tetrachloroethylene, 1,1-Dichloroethane, Carbon tetrachloride, 1,3-Butadiene, and Dichloromethane. The HAPs PSMs were gravimetrically prepared in aluminum cylinders and their consistency was verified within the relative expanded uncertainty of 0.71% (k=2). Potential adsorption loss onto the internal surface of cylinders was estimated by cylinder-to-cylinder division method. No adsorption loss was observed within the uncerainty of 0.53%. The long-term stability of the HAPs PSMs was evaluated comparing with freshly prepared HAPs PSMs. The HAPs PSMs were stable for one year within the uncertainty of 0.38%. The final uncertainty of the PSMs was determined by combining the preparation uncertainty, verification uncertainty, and stability uncertainty. Finally, traceable and stable HAPs PSMs at $1{\mu}mol/mol$ levels were developed with the uncertainty of less than 0.76% in high-pressure aluminum cylinders.

Mass Balance Method for Purity Assessment of Organic Reference Materials: for Thermolabile Materials with LC-UV Method

  • Lee, Joonhee;Kim, Byungjoo
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.11
    • /
    • pp.3275-3279
    • /
    • 2014
  • A mass balance method for purity assessment of thermolabile organic reference materials was established by combining several techniques, including liquid chromatography with UV/VIS detector (LC-UV), Karl-Fischer (K-F) Coulometry, and thermal gravimetric analysis (TGA). This method was applied to three fluoroquinolones like enrofloxacin, norfloxacin and ciprofloxacin. LC-UV was used to analyze structurally related organic impurities based on UV/VIS absorbance spectra obtained in combination with LC separation. For all three organic reference materials, the UV/VIS spectra of the separated impurities were similar to that of the major component of the corresponding materials. This indicates that the impurities are structurally related to the respective reference material sharing common chromophores. Impurities could be quantified by comparing their absorbances at the wavelength of maximum absorbance (${\lambda}_{max}$). The water contents of the reference materials were measured by K-F Coulometry by an oven-drying method. The total inorganic impurities contents were assayed from ash residues in TGA analysis with using air as a reagent gas. The final purities estimated from results of those analytical techniques were assigned as ($99.91{\pm}0.06$), ($97.09{\pm}0.17$) and ($91.85{\pm}0.17$)% (kg/kg) for enrofloxacin, norfloxacin and ciprofloxacin, respectively. The assigned final purities would be applied to the reference materials which will be used as calibrators for the certification of those compounds in matrix CRMs as starting points for the traceability of their certified values to SI units.