• 제목/요약/키워드: SHM(Structural Health Monitoring)

검색결과 314건 처리시간 0.03초

Real time crack detection using mountable comparative vacuum monitoring sensors

  • Roach, D.
    • Smart Structures and Systems
    • /
    • 제5권4호
    • /
    • pp.317-328
    • /
    • 2009
  • Current maintenance operations and integrity checks on a wide array of structures require personnel entry into normally-inaccessible or hazardous areas to perform necessary nondestructive inspections. To gain access for these inspections, structure must be disassembled and removed or personnel must be transported to remote locations. The use of in-situ sensors, coupled with remote interrogation, can be employed to overcome a myriad of inspection impediments stemming from accessibility limitations, complex geometries, the location and depth of hidden damage, and the isolated location of the structure. Furthermore, prevention of unexpected flaw growth and structural failure could be improved if on-board health monitoring systems were used to more regularly assess structural integrity. A research program has been completed to develop and validate Comparative Vacuum Monitoring (CVM) Sensors for surface crack detection. Statistical methods using one-sided tolerance intervals were employed to derive Probability of Detection (POD) levels for a wide array of application scenarios. Multi-year field tests were also conducted to study the deployment and long-term operation of CVM sensors on aircraft. This paper presents the quantitative crack detection capabilities of the CVM sensor, its performance in actual flight environments, and the prospects for structural health monitoring applications on aircraft and other civil structures.

효과적인 구조물 진단 시스템을 위한 MULTI MODE 계측법의 연구 (Study about MULTI MODE Measurement Algorithm For Effective Structural Monitoring System)

  • 홍용;왕고평;황승호;박현우;홍동표
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1382-1385
    • /
    • 2007
  • In this paper, we study about the measuring algorithm that can implement Structural Health Monitoring (SHM) more efficiently by two measurement methods using smart sensor. Through the impedance measurement method, the damage condition of structures on wide area is monitored first, and then it changes the mode to guided wave measurement mode by mode switching algorithm when impedance measurement mode detects abnormal signals. Efficient handling of the real-time data would be available by analyzing location and shape of damage through guided wave measurement.

  • PDF

Issues in structural health monitoring for fixed-type offshore structures under harsh tidal environments

  • Jung, Byung-Jin;Park, Jong-Woong;Sim, Sung-Han;Yi, Jin-Hak
    • Smart Structures and Systems
    • /
    • 제15권2호
    • /
    • pp.335-353
    • /
    • 2015
  • Previous long-term measurements of the Uldolmok tidal current power plant showed that the structure's natural frequencies fluctuate with a constant cycle-i.e., twice a day with changes in tidal height and tidal current velocity. This study aims to improve structural health monitoring (SHM) techniques for offshore structures under a harsh tidal environment like the Uldolmok Strait. In this study, lab-scale experiments on a simplified offshore structure as a lab-scale test structure were conducted in a circulating water channel to thoroughly investigate the causes of fluctuation of the natural frequencies and to validate the displacement estimation method using multimetric data fusion. To this end, the numerical study was additionally carried out on the simplified offshore structure with damage scenarios, and the corresponding change in the natural frequency was analyzed to support the experimental results. In conclusion, (1) the damage that occurred at the foundation resulted in a more significant change in natural frequencies compared with the effect of added mass; moreover, the structural system became nonlinear when the damage was severe; (2) the proposed damage index was able to indicate an approximate level of damage and the nonlinearity of the lab-scale test structure; (3) displacement estimation using data fusion was valid compared with the reference displacement using the vision-based method.

A multi-radio sink node designed for wireless SHM applications

  • Yuan, Shenfang;Wang, Zilong;Qiu, Lei;Wang, Yang;Liu, Menglong
    • Smart Structures and Systems
    • /
    • 제11권3호
    • /
    • pp.261-282
    • /
    • 2013
  • Structural health monitoring (SHM) is an application area of Wireless Sensor Networks (WSNs) which usually needs high data communication rate to transfer a large amount of monitoring data. Traditional sink node can only process data from one communication channel at the same time because of the single radio chip structure. The sink node constitutes a bottleneck for constructing a high data rate SHM application giving rise to a long data transfer time. Multi-channel communication has been proved to be an efficient method to improve the data throughput by enabling parallel transmissions among different frequency channels. This paper proposes an 8-radio integrated sink node design method based on Field Programmable Gate Array (FPGA) and the time synchronization mechanism for the multi-channel network based on the proposed sink node. Three experiments have been performed to evaluate the data transfer ability of the developed multi-radio sink node and the performance of the time synchronization mechanism. A high data throughput of 1020Kbps of the developed sink node has been proved by experiments using IEEE.805.15.4.

Computational aspects of guided wave based damage localization algorithms in flat anisotropic structures

  • Moll, Jochen;Torres-Arredondo, Miguel Angel;Fritzen, Claus-Peter
    • Smart Structures and Systems
    • /
    • 제10권3호
    • /
    • pp.229-251
    • /
    • 2012
  • Guided waves have shown a great potential for structural health monitoring (SHM) applications. In contrast to traditional non-destructive testing (NDT) methodologies, a key element of SHM approaches is the high process of automation. The monitoring system should decide autonomously whether the host structure is intact or not. A basic requirement for the realization of such a system is that the sensors are permanently installed on the host structure. Thus, baseline measurements become available that can be used for diagnostic purposes, i.e., damage detection, localization, etc. This paper contributes to guided wave-based inspection in anisotropic materials for SHM purposes. Therefore, computational strategies are described for both, the solution of the complex equations for wave propagation analysis in composite materials based on exact elasticity theory and the popular global matrix method, as well as the underlying equations of two active damage localization algorithms for anisotropic structures. The result of the global matrix method is an angular and frequency dependent wave velocity characteristic that is used subsequently in the localization procedures. Numerical simulations and experimental investigations through time-delay measurements are carried out in order to validate the proposed theoretical model. An exemplary case study including the calculation of dispersion curves and damage localization is conducted on an exemplary unidirectional composite structure where the ultrasonic signals processed in the localization step are simulated with the spectral element method. The proposed study demonstrates the capabilities of the proposed algorithms for accurate damage localization in anisotropic structures.

Structural health monitoring data reconstruction of a concrete cable-stayed bridge based on wavelet multi-resolution analysis and support vector machine

  • Ye, X.W.;Su, Y.H.;Xi, P.S.;Liu, H.
    • Computers and Concrete
    • /
    • 제20권5호
    • /
    • pp.555-562
    • /
    • 2017
  • The accuracy and integrity of stress data acquired by bridge heath monitoring system is of significant importance for bridge safety assessment. However, the missing and abnormal data are inevitably existed in a realistic monitoring system. This paper presents a data reconstruction approach for bridge heath monitoring based on the wavelet multi-resolution analysis and support vector machine (SVM). The proposed method has been applied for data imputation based on the recorded data by the structural health monitoring (SHM) system instrumented on a prestressed concrete cable-stayed bridge. The effectiveness and accuracy of the proposed wavelet-based SVM prediction method is examined by comparing with the traditional autoregression moving average (ARMA) method and SVM prediction method without wavelet multi-resolution analysis in accordance with the prediction errors. The data reconstruction analysis based on 5-day and 1-day continuous stress history data with obvious preternatural signals is performed to examine the effect of sample size on the accuracy of data reconstruction. The results indicate that the proposed data reconstruction approach based on wavelet multi-resolution analysis and SVM is an effective tool for missing data imputation or preternatural signal replacement, which can serve as a solid foundation for the purpose of accurately evaluating the safety of bridge structures.

스마트 능동 레이어 센서 개발 (II): 저작 및 적용 연구 (Development of Smart Active Layer Sensor (II): Manufacturing and Application)

  • 이영섭;이상일;권재화;윤동진
    • 비파괴검사학회지
    • /
    • 제24권5호
    • /
    • pp.476-486
    • /
    • 2004
  • 본 논문은 두 편으로 구성된 스마트능동레이어 (smart active layer, SAL) 센서 개발에 관한 두 번째 것이다. 이미 첫 번째 논문에서 언급되었지만, 구조물 건전성 감시 (structural health monitoring, SHM)는 구조물 안전 감시의 비용과 편리성을 개선하기 위한 방법으로서, 산업현장에서 그 응용이 점차 증가하는 새로운 기술이며, 최근 실제 응용을 하기 위한 스마트 센서의 개발 및 연구가 매우 활발하다. 본 논문에서는 첫 번째 논문에 기술된 SAL 센서의 이론 및 개념 연구에 이어서 실제 제작 및 적용연구에 관해 기술한다. 본 연구에서는 탄성파 감지를 위한 스마트 압전 센서 SAL을 개발하였는데, 압전 소자, 전자기파 차폐층 (EMI shielding lave.) 및 보호 층(protection layer)으로 구성되었다. 보호층에 일정 간격으로 분포된 압전 센서가 부착되고, 이들을 전기적으로 연결하는 회로층이 위치하고 있다. 모두 4종류의 SAL 센서가 설계, 제작 및 시험되었으며 이에 대해 상세히 기술하고 있다. 본 연구를 통해 SAL 센서는 SHM의 수행과 탄성파에 의한 손상 위치를 표정하는데 적용 가능할 것으로 예상된다.

Developing a smart structure using integrated DDA/ISMP and semi-active variable stiffness device

  • Karami, Kaveh;Nagarajaiah, Satish;Amini, Fereidoun
    • Smart Structures and Systems
    • /
    • 제18권5호
    • /
    • pp.955-982
    • /
    • 2016
  • Recent studies integrating vibration control and structural health monitoring (SHM) use control devices and control algorithms to enable system identification and damage detection. In this study real-time SHM is used to enhance structural vibration control and reduce damage. A newly proposed control algorithm, including integrated real-time SHM and semi-active control strategy, is presented to mitigate both damage and seismic response of the main structure under strong seismic ground motion. The semi-active independently variable stiffness (SAIVS) device is used as semi-active control device in this investigation. The proper stiffness of SAIVS device is obtained using a new developed semi-active control algorithm based on real-time damage tracking of structure by damage detection algorithm based on identified system Markov parameters (DDA/ISMP) method. A three bay five story steel braced frame structure, which is equipped with one SAIVS device at each story, is employed to illustrate the efficiency of the proposed algorithm. The obtained results show that the proposed control algorithm could significantly decrease damage in most parts of the structure. Also, the dynamic response of the structure is effectively reduced by using the proposed control algorithm during four strong earthquakes. In comparison to passive on and off cases, the results demonstrate that the performance of the proposed control algorithm in decreasing both damage and dynamic responses of structure is significantly enhanced than the passive cases. Furthermore, from the energy consumption point of view the maximum and the cumulative control force in the proposed control algorithm is less than the passive-on case, considerably.

Admittance를 기반으로 한 센서 자가 진단 알고리즘의 실험적 검증 - 상호비교를 통한 센서 결함 탐지 (Validation of Piezoelectric Sensor Diagnostics Algorithm Using Instantaneous Baseline Data)

  • 조혜진;정휘권;박통일;박규해
    • Composites Research
    • /
    • 제28권4호
    • /
    • pp.148-154
    • /
    • 2015
  • 구조건전성 모니터링은 구조물에 발생된 손상을 조기에 감지 및 적절한 유지보수를 통해 재정적 혹은 인명 피해를 방지하기 위해 실시된다. 대부분의 능동센싱 기반 구조건전성 모니터링에서는 많은 수의 압전체(piezoelectric transducer) 센서와 구동기(actuator)를 필요로 한다. 구조건전성 모니터링 시 사용된 압전센서에 결합이 존재하는 경우, 구조물의 상태진단에 문제가 발생할 수 있다. 본 연구에서는 신뢰성 있는 구조건전성 모니터링 결과를 위해 임피던스 기반 센서 자가 진단법을 사용하여 다수 센서의 결함을 탐지하였다. 또한 사용된 접착제와 센서의 정보가 충분치 못한 경우, 사용된 센서로부터 측정된 데이터만을 토대로 센서결함 진단을 위한 알고리즘을 소개하였다. 알고리즘이 적용 가능한 온도 범위를 실험적으로 분석함으로써 개발된 기법이 실제 환경에서 응용이 가능함을 확인하였다.

상시진동을 이용한 격납건물의 동적특성에 관한 연구 (Study on the Dynamic Characteristics of a Containment using Ambient Vibration Data)

  • 박수용;최상현;현창헌;김문수
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2010년도 정기 학술대회
    • /
    • pp.696-699
    • /
    • 2010
  • 원자력 발전소의 격납건물은 인위적 또는 자연적 재해로부터 방사능의 외부누출을 방지함으로써 공중을 보호하는 역할을 하기 때문에 지속적인 건전성 확인을 통해 안전을 확보하는 것이 필수적이다. 격납건물의 구조적 건전성 확인은 통상 주기적으로 콘크리트에 대한 비파괴강도, 균열 및 중성화, 프리스트레스 텐던의 유효 긴장력 등의 측정을 통해 수행되고 있으나, 이러한 검사는 국부적인 건전도 정보만을 제공할 뿐 격납건물과 같은 대형 구조물 전체의 건전성에 대한 신뢰성 있는 평가 결과를 얻는데 많은 시간과 경비가 소요된다는 단점이 있다. 이러한 단점은 최근 구조물 전체의 상태를 평가하는 방법으로 주목받고 있는 구조건전성모니터링(Structural Health Monitoring, SHM)기법을 이용하여 극복할 수 있다. 본 논문에서는 실제 운전 중인 격납건물을 대상으로 상시진동 측정을 수행하였으며, SHM 기법의 기초자료로 활용될 수 있는 동적특성, 즉 격납건물의 고유진동수와 모드형상을 제시하였다.

  • PDF