• 제목/요약/키워드: SHGC(Solar Heat Gain Coefficient)

검색결과 16건 처리시간 0.019초

건물 외피의 열특성과 외주부 깊이에 따른 PAL에 관한 연구 (A study on the PAL according to thermal characteristic of building skin and perimeter zone depth)

  • 김지혜;김환용
    • 한국태양에너지학회 논문집
    • /
    • 제30권2호
    • /
    • pp.33-38
    • /
    • 2010
  • The perimeter zone is space which receives a significant effect of ambient condition, it is necessary to improve the thermal performance in order to building energy saving. For this reason, a lot of study about the active approach is being performed, such as perimeter-less air conditioning system. But the performance of the perimeter zone is necessary to improve, through the passive approach. Therefore, the purpose of this study is to provide basic materials of energy-saving design of perimeter zone, based of the PAL that simulation changing the thickness of insulation and the rate of windows.

창호의 성능 및 건물의 창면적비에 따른 기존 단독주택의 창호 리모델링 방안 연구 (Optimum Method of Windows Remodeling of Existing Residential according to the Window Properties and Window Wall Ratio)

  • 이나은;안병립;정학근;김종훈;장철용
    • KIEAE Journal
    • /
    • 제13권3호
    • /
    • pp.71-78
    • /
    • 2013
  • A need for building energy efficiency is on the issue since energy demand in the building stock in Korea represents about 24% of the final energy consumption. As a way of improving the thermal performance of buildings for reducing maintenance costs and environmental conservation, a lot of effort is shown to improve the building energy efficiency by applying improvement of envelope insulation performance for buildings whose energy efficiency is low relatively through the remodeling. The windows of building envelopes are areas that lead to the biggest heat loss in the building. So windows are considered to be the primary target of energy efficiency in remodeling and various studies for windows have been done. Currently, however, only U-factor and airtightness of windows performance are regulated. Window wall ratio(WWR) and solar heat gain coefficient(SHGC) of windows are not considered when conducting the remodeling. In this study appropriate performance of windows(U-factor and SHGC) for existing residential is proposed according to the window wall ratio by using EnergyPlus. As the results of this study, the U-factor of windows representing the maximum energy savings is $1.0W/m^2K$ but in case of SHGC, the values that indicate the maximum energy savings are different depending on the window wall ratio. Therefore, when conducting the remodeling of windows, to determine energy efficiency by considering only the U-factor is inadequate so it is necessary that appropriate windows are applied to buildings by considering window wall ratio and windows properties(U-factor and SHGC).

Electrochromic 창호 적용시 지역별 건물 냉난방 에너지 소비량 절감성능 (Performance Evaluation of Electrochromic Window System by Different Orientations and Locations in Korea)

  • 신재윤;채영태
    • 한국태양에너지학회 논문집
    • /
    • 제38권5호
    • /
    • pp.75-84
    • /
    • 2018
  • The most crucial point of reducing building energy is application of high performance envelope. The amount of heat exchange through window is highest in comparison of other envelopes so that heat exchange through window influence directly with building energy consumption. The window energy performance can be define with thermal, leakage and optical performance. In previous study we can confirmed that not only thermal performance but also optical performance are considered, 11% to 15% of building energy consumption can be reduced. Smart window system has potential of energy saving so that many industry field use smart window system including architectural area and these aspect causes smart window market continuous growth year by year. In this study, building energy consumption has been analyzed which consist of smart window that dynamically control optical states. The consideration of standard commercial building model for research, the reference medium size commercial building model of DOE (Department Of Energy, USA) has been used. The building energy simulation result of 4 axis in 8 regions in Korea shows 8% to 22% reduction of building energy consumption by application of smart window system.

창호의 성능인증 규격 기준과 면적 변화에 따른 에너지성능 비교분석 (A Comparative Analysys of Window Energy Performance According to the Difference Between Actual size and Standard size)

  • 김성범;이수열;김동윤;최원기
    • 한국태양에너지학회 논문집
    • /
    • 제40권1호
    • /
    • pp.49-60
    • /
    • 2020
  • This study reviewed selected specific windows and reviewed the window performance certification criteria including KS F 2278 and KS L 9107 and analyzed the change in performance based on the change of area. This study also compared the heating and cooling loads of an apartment house applied with window performance reviewed in consideration of insulation and SHGC performance and actual size based on KS F 2278. The analyzed window was a double window composed of aluminum and PVC and the building was the apartment house model of 141 ㎡. The analysis results were as follows. First, as the window glass's thermal performance is superior to frame, the performance degraded in reduced area. In case of selected window, the 1 m × 1m window's thermal performance and SHGC decreased by 35% and 37% respectively compared to 2 m × 2 m window. Secondly, in the comparison of performance for increasing area with 2 m × 2 m and 3 m × 3 m windows, the 3 m × 3 m window's thermal performance and SHCG increased about 14%. Third, in the comparison of heating and cooling loads of the analyzed model considering the apartment house model applied with window performance derived from KS F 2278 and actual figures, the model's total heating and cooling loads increased by 33% with cooling decreasing by 36% and heating increasing by 77%. Above analysis results show that evaluation of window performance based on criteria such as KS F 2278 and KS L 9107 may lead to distortion of performances different from actual products. Thus, it is necessary to suggest new evaluation criteria.

단열 도료 코팅 창호의 냉난방부하 특성분석 및 경제성 평가 (The Estimation of Heating, Cooling Load and Economical Efficiency Analysis of Insulation Paint Coating Windows)

  • 정열화;김병수
    • 한국태양에너지학회 논문집
    • /
    • 제31권6호
    • /
    • pp.95-102
    • /
    • 2011
  • The purpose of study is to estimate heating, cooling load performance and economic efficiency in office building with applied the functional paint. this paint can reduced SHGC(Solar Heat Gain Coefficient) on the glazing surface by coating. In this study, estimated to compared with double glazing, low-e glazing, IP(Insulation Paint) and IPu(Insulation UV-Cut Paint) coating glazing. As a result of this study, 1)heating & cooling load Analysis, SHGC value and U-factor of double glazing is about 0.70 and 3.29($W/m^2K$). low-E glazing is about 0.65 and 2.70($W/m^2K$). Two-side it is about 0.27 and 3.25($W/m^2K$). When compared to double glazing, annual heating & cooling load of low-E glazing, Two-side IPu and IP paint coating glazing is 3,012MWh($124kWh/m^2$), 2,910MWh($120kWh/m^2$), 2,867MWh($118.4kWh/m^2$) and 2,867MWh($118.4kWh/m^2$). It i sreduced to 2.0%, 5.2%, 6.7%, and 6.7% respectively. 2)the estimation of economic efficiency, low-e glazing installed in office building can not recover the investment within a lifetime 40years. but IPu and IP paint, two-side coating in glazing, have a payback period of 13 years respectively.

염료감응태양전지의 광학특성분석을 통한 건축창호 적용가능성 평가 연구 (An Evaluation of Application Possibility of Window System in the Building based on Optical Characteristics Analysis of DSSC)

  • 심세라;윤종호;정선영;백남춘
    • 한국태양에너지학회 논문집
    • /
    • 제31권3호
    • /
    • pp.109-115
    • /
    • 2011
  • It can gain both the electric energy production and disperse of light at the same time if DSSC is applied in the building as window system. It means to help facade design and to be used in lighting, heating, cooling energy directly by applicating DSSC BIPV window that is possible to daylighting and materialization of color. For this, optical characteristics analysis that is basic step must take precedence. So, basic databases of DSSC are builded and optical performances according to the double and triple glazing are evaluated by analyzing spectral data of various colored DSSC. As a result, Green(4) has the highest visible transmittance that is 28.8%, and Blue(3) has the lowest that is 0.3%. And, in case of optical performance of Green(4) depending on the incidence angle, SHGC and Tsol are decreased sharply from more than $60^{\circ}C$. Finally, It is judged that Red(4), Green(1), (4), Blue(4) are suitable for application in office building because visible transmittance is high and solar heat gain coefficient is low relatively in spite of composing to double and triple glazing.