• 제목/요약/키워드: SHEAR STRENGTH

검색결과 5,534건 처리시간 0.032초

세그멘탈 합성보 접합부 전단 모델 시험 (Shear Modeling Tests for Post-Tensioned Composite Segmental Beams)

  • 설동재;김인규;유승룡
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.481-486
    • /
    • 2002
  • A precast concrete beam which is larger than the limits of domestic transportation regulation in weight, length, and volume is divided into three parts, transported separately, and erected with a composite beam by post-tensioning in site. Shear tests are performed on the post-tensioned composite segmental beam models with 1/2 scale. The jacking force and the ratio of area of shear key to beam section are major experimental variables. Nine shear strength are resulted from the tests with two variables. Rational equation for estimation of shear strength are obtained from the regression analysis on test results.

  • PDF

화강암질풍화토(花崗岩質風化土)의 역학적(力學的) 성질(性質)에 관(關)한 연구(硏究) -전단강도(剪斷强度)의 영향요소(影響要素)와 견밀도(堅密度)에 대(對)하여- (Studies on the Mechanical Properties of Weathered Granitic Soil -On the Elements of Shear Strength and Hardness-)

  • 조희두
    • 한국산림과학회지
    • /
    • 제66권1호
    • /
    • pp.16-36
    • /
    • 1984
  • 화강암질풍화토(花崗岩質風化土)의 미교란(未攪亂) 시료(試料)를 사용하여 일면(一面) 직접(直接) 전단시험(剪斷試驗)으로 측정(測定)한 전단강도(剪斷强度)와 함수비(含水比), 간극비(間隙比), 건조밀도(乾燥密度), 비중(比重)과의 관계(關係)를 통계(統計) 분석(分析)하였고, 화강암질풍화토(花崗岩質風化土)의 사방시공지(砂防施工地)에 식재(植栽)된 리기다소나무림(林)과 리기테-다소나무림(林)에서 토양단면(土壤斷面)을 만들어 산중식토양경도계(山中式土壤硬度計)로 토양(土壤)의 견밀도(堅密度)를 측정(測定)하고 수근분포(樹根分布)를 조사(調査)하여 통계(統計) 분석(分析)한 결과(結果) 다음과 같다. 1) 함수비(含水比), 간극비(間隙比)와 전단강도(剪斷强度) 간(間)에는 유의적(有意的)인 부(負)의 상관(相關)이며 직접적(直接的)인 관계(關係)에 있었다. 2) 건조밀도(乾燥密度)와 전단강도(剪斷强度) 사이에는 정(正)의 상관(相關)이며 직접적(直接的)인 관계(關係)에 있었다. 3) 비중(比重)과 전단강도(剪斷强度) 간(間)에는 유의적(有意的)인 상관관계(相關關係)를 인정(認定)할 수 없었다. 4) 전단강도(剪斷强度)에 영향(影響)을 미치는 영향요소(影響要素)의 직접효과(直接效果)의 크기는 함수비(含水比)>간극비(間隙比)>건조밀도(乾燥密度)의 순위(順位)이다. 5) 다중선형(多重線型) 회귀방정식(回歸方程式)의 분산분석결과(分散分析結果) 함수비(含水比)만이 회귀성(回歸性)이 인정(認定)되므로 함수비(含水比)를 독립변수(獨立變數)로 하여 전단강도(剪斷强度)를 추정(推定)하기 위한 회귀방정식(回歸方程式)은 제한(制限)된 건조밀도(乾燥密度)의 범위내(範圍內)에서 적합도(適合度)가 매우 높게 평가(評價)되었다. 6) 토양(土壤)의 견밀도(堅密度)는 토심(土深)이 깊어짐에 따라 높아진다. 7) 토양(土壤)의 지표경도(指標硬度)와 수근수(樹根數) 간(間)에는 유의적(有意的)인 부(負)의 상관(相關)이며 직접적(直接的)인 관계(關係)에 있었다. 8) 리기다소나무와 리기테-다소나무의 수근(樹根)은 토심(土深) 20cm까지에 대부분 분포(分布)하고 있었다. 9) 리기다소나무림(林)과 리기테-다소나무림(林)에서 측정(測定)한 토양(土壤)의 지표경도(指標硬度)를 독립변수(獨立變數)로한 회귀방정식(回歸方程式)으로 수근수(樹根數)를 추정(推定)할 수 있었으나 낮은 적합도(適合度)를 나타내었다.

  • PDF

환경인자에 노출된 탄소섬유/에폭시 복합재의 장기 층간전단강도 예측 (Prediction of Long-Term Interlaminar Shear Strength of Carbon Fiber/Epoxy Composites Exposed to Environmental Factors)

  • 윤성호
    • Composites Research
    • /
    • 제30권1호
    • /
    • pp.71-76
    • /
    • 2017
  • 본 연구에서는 환경인자에 노출된 탄소섬유/에폭시 복합재의 층간전단강도를 이용하여 장기 성능을 예측하였다. 필라멘트와인딩 공법으로 제작된 층간전단시편은 분위기 온도가 $50^{\circ}C$, $70^{\circ}C$, $100^{\circ}C$인 건조 조건과 분위기 온도가 $25^{\circ}C$, $50^{\circ}C$, $70^{\circ}C$인 침수 조건에 각각 3000시간까지 노출시켰다. 연구결과에 따르면 분위기 온도가 $50^{\circ}C$$70^{\circ}C$인 건조 상태에서는 층간전단강도가 노출시간에 따라 크게 변하지 않지만 분위기 온도가 $100^{\circ}C$인 건조 상태에서는 노출시간이 길어지면 후경화로 인해 다소 증가한다. 그러나 분위기 온도가 $25^{\circ}C$인 침수 상태의 경우 층간전단강도는 노출 초기에 크게 변하지 않다가 노출시간이 길어지면 감소하고 감소 정도는 분위기 온도가 높아지면 커진다. 각 분위기 온도에 대한 층간전단강도 선형회귀식은 침수 상태에 3000시간까지 노출된 시편에서 얻은 층간전단강도에서 구할 수 있었다. 이들 선형 회귀식을 이용하면 층간전단강도는 분위기 온도가 $25^{\circ}C$$50^{\circ}C$인 경우 측정값의 5.5% 이내, 분위기 온도가 $70^{\circ}C$인 경우 측정값의 2.3% 이내로 예측이 가능하였다. 따라서 제시된 성능 예측 절차는 환경인자에 노출된 탄소섬유/에폭시 복합재의 장기 층간전단강도를 잘 예측할 수 있다.

Effect of silicone rubber-sleeve mounted on shear studs on shear stiffness of steel-concrete composite structures

  • Yang, Chang;Yang, Decan;Huang, Caiping;Huang, Zhixiang;Ouyang, Lizhi;Onyebueke, Landon;Li, Lin
    • Steel and Composite Structures
    • /
    • 제44권5호
    • /
    • pp.741-752
    • /
    • 2022
  • Earlier works have shown that excessive shear stiffness at the steel-concrete interface causes a non-uniform distribution of shear force in composite structures. When the shear studs are wrapped at the fixed end with flexible materials with a low elastic modulus, the shear stiffness at the interface is reduced. The objective of this study was to investigate the effect of silicone rubber-sleeve mounted on shear studs on the shear stiffness of steel-concrete composite structures. Eighteen push-out tests were conducted to investigate the mechanical behavior of silicone rubber-sleeved shear stud groups (SRS-SSG). The dimension and arrangement of silicon rubber-sleeves (SRS) were taken into consideration. Test results showed that the shear strength of SRS-SSG was higher than that of a shear stud group (SSG), without SRS. For SRS-SSG with SRS heights of 50 mm, 100 mm, 150 mm, the shear strengths were improved by 13%, 20% and 9%, respectively, compared to the SSG alone. The shear strengths of SRS-SSG with the SRS thickness of 2 mm and 4 mm were almost the same. The shear stiffness of the SRS-SSG specimens with SRS heights of 50 mm, 100 mm and 150 mm were 77%, 67% and 66% of the SSG specimens, respectively. Test results of specimens SSG-1 and predicted values based on the three design specifications were compared. The nominal single stud shear strength of SSG-1 specimens was closest to that calculated by the Chinese Code for Design of Steel Structures (GB50017-2017). An equation is proposed to consider the effects of SRS for GB50017-2017, and the predicted values based on the proposed equation agree well with the tested results of SRS-SSG.

철근콘크리트 깊은 보에서 전단철근비와 전단내력의 관계 (The Relationships Between Shear Reinforcement Ratios and Shear Strength in Reinforced Concrete Deep Beams)

  • 양근혁;박정화;정헌수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.256-259
    • /
    • 2004
  • The objective of this experimental study is to understand the effects of horizontal and vertical shear reinforcement on the shear strength of concrete deep beams. Main variables were the horizontal shear reinforcement ratio $(P_{sh})$, vertical shear reinforcement ratio$(P_{sv})$ and shear span-to-overall depth ratio(a/h). Test results revealed that the effectiveness of shear resistance of shear reinforcement was greatly related to the a/h. For the beams with $a/h\geq1.0$, the vertical shear reinforcement was more effective than horizontal shear reinforcement.

  • PDF

Shear Index로 표시된 E. coli Floc의 강도 (Strength of E. coli Floc as indicated by Shear Index)

  • 나초균
    • 유변학
    • /
    • 제8권3_4호
    • /
    • pp.226-231
    • /
    • 1996
  • 침강제에 의해 형성된 E. coli floc들의 강도를 측정하기 위해 floc 의 shear index를 측정하였다. 형성된 E. coli floc은 10/sec 같이 낮은 shear rate에서도 분쇄되거나 변형되었 다. 측정된 shear index의 감소에서 보듯이 E. coli floc의 강도는 염의 농도가 증가함에 EK 라 감소하였다. E. coli floc의 shear index는 NaCl의 농도가 0에서 100 mM로 증가함에 따 라 0.47에서 0.09로 줄었다. 발효배지의 조성에서 형성된 E. coli floc들은(shear index=0.18-0.24 with BPA-1000. 0.13-0.22 with BPA-1050 and 0.37-0.42 with BPA-5020) 염이 없을 때 형성된 floc에(shear index=0.47 with BPA-1000 and 0.46 with BPA-1050) 비 해 약하였다. 따라서 발효배지에서 형성된 floc은 생물공정 중 쉽게 shear에 의해 분쇄되거 나 변형될것이다.

  • PDF

막요소 해석에 사용된 트러스 모델을 이용한 철근콘크리트 보의 전단거동 예측 (Shear Response Prediction of the Reinforced Concrete Beams using Truss Models for Membrane Element Analysis)

  • 김상우;이정윤
    • 한국공간구조학회논문집
    • /
    • 제3권1호
    • /
    • pp.77-85
    • /
    • 2003
  • This paper presents a truss model that can predict the shear behavior of reinforced concrete (RC) beams subjected to the combined actions of shear and flexure. Unlike other truss models, the proposed truss model, TATM, takes into account the effect of the flexural moment on the shear strength of RC beams with different shear span-to-depth ratios. To check the successfulness of the proposed model experimentally obtained stress shear strain curves were compared to the predicted ones using the proposed truss model. Furthermore, the shear strengths of 170 RC test beams with variable shear span-to-depth ratios were compared to the shear strengths as given by the truss model reported in this paper.

  • PDF

Minimum shear reinforcement ratio of prestressed concrete members for safe design

  • Park, Min-Kook;Lee, Deuck Hang;Ju, Hyunjin;Hwang, Jin-Ha;Choi, Seung-Ho;Kim, Kang Su
    • Structural Engineering and Mechanics
    • /
    • 제56권2호
    • /
    • pp.317-340
    • /
    • 2015
  • Design codes have specified the minimum shear reinforcement requirement for reinforced concrete (RC) and prestressed concrete (PSC) members to prevent brittle and premature shear failure. They are, however, very different from one another, and particularly, ACI318 code allows the required minimum shear reinforcement to be reduced in PSC members, compared to that in RC members, by specifying the additional equation for PSC members whose basis is not clear. In this paper, the minimum shear reinforcement ratio for PSC members was proposed, which can provide a sufficient reserved shear strength and deformation capacity. The proposed equation was also verified by the test results of PSC specimens lightly reinforced in shear, comparing to design codes and other proposed equations from previous studies.

Interfacial shear resistance of angle shear connectors welded to concrete filled U-shaped CFS beam

  • Oh, Hyoung Seok;Shin, Hyeongyeop;Ju, Youngkyu;Kang, Thomas H.K.
    • Steel and Composite Structures
    • /
    • 제43권3호
    • /
    • pp.311-325
    • /
    • 2022
  • For multi-story structural systems, Korean steel industry has fostered development of a steel-concrete composite beam. Configuration of the composite beam is characterized by steel angle shear connectors welded to a U-shaped cold formed-steel beam. Effects of shear connector orientation and spacing were studied to evaluate current application of the angle shear connector design equation in AC495. For the study, interfacial shear resistance behavior was investigated by conducting 24 push-out tests and attuned using unreinforced push-out specimens. Interfacial shear to horizontal slip response was reported along with corresponding failure patterns. Pure shear connector strength was also evaluated by excluding concrete shear contribution, which was estimated in relation to steel beam-slab interface separation or interfacial crack width.

가혹 환경이 복합재/Ni-Cr 합금 접착전단강도에 미치는 영향 연구 (Effect of Adhesive Shear Strength of CFRP/Ni-Cr Alloy Under Severe Environmental Condition)

  • 조현태;박성민;김민준;황반토;김학인;손명숙;안종기;안지민;최진호;남영우;권진회
    • Composites Research
    • /
    • 제33권5호
    • /
    • pp.275-281
    • /
    • 2020
  • 본 논문에서는 항공기 팬 블레이드에 적용되는 복합재와 금속 간의 접합 구조물에 대한 온도, 습도에 따른 접착제의 물성 변화에 관해 연구하였다. 항공기 운용 시 노출되는 환경 조건을 고려하여 상온 건조(Room Temperature Dry, RTD), 고온 흡습(Evaluated Temperature Wet, ETW), 저온 건조(Cold Temperature Dry, CTD) 세가지 환경에서 강도 시험을 수행하였다. 접착전단강도 시험은 ASTM D3528을 기준으로 수행하였고, 파손 영역에 대한 마이크로 구조 특성을 SEM이미지를 통해 분석하였다. 연구 결과에 따르면 RTD 환경에서의 전단강도 대비하여 ETW 환경에서 72.8% 저하되었으며, CTD 환경에서는 56.5% 증가되었다. 이는 고온 및 수분 흡습이 접착제의 기계적 특성에 큰 영향을 미치는 것을 확인했고, 저온 환경에서는 모재와 접착제 모두 취성의 증가로 인해 접착 전단 강도가 향상된 것으로 분석되었다.