• Title/Summary/Keyword: SEP

Search Result 1,146, Processing Time 0.026 seconds

EL-SEP: Improved L-SEP by adding Single-hop layer

  • LEE, WooSuk;Jung, Kye-Dong;Lee, Jong-Yong
    • International journal of advanced smart convergence
    • /
    • v.6 no.1
    • /
    • pp.50-56
    • /
    • 2017
  • Wireless sensor nodes have limited energy, so it is important to optimize energy consumption to preserve network lifetime. Various protocols have been proposed for this purpose. LEACH protocol and SEP are the representative protocols. These protocols become less effective as the Sensor Field becomes wider. To improve this, MR-SEP and L-SEP were proposed. These protocols increase the energy efficiency by dividing the Sensor Field into layers and reducing the transmission distance. However, when dividing a layer, there are cases where it is divided inefficiently, and a node within a certain range from a Base Station has a better transmission efficiency than a direct transmission method using a cluster method. In this paper, we propose a Single-hop layer for L-SEP to improve inefficient layer division and near node transmission efficiency. When the larger the Sensor Field, the better the performance of the proposed method by up to 87%. The larger the sensor field, the more efficient the proposed method is over the conventional method. That is, the proposed method is suitable for the wide Sensor Field.

A Fully Integrated CMOS Security-Enhanced Passive RFID Tag

  • Choi, Suna;Kim, Hyunseok;Lee, Sangyeon;Lee, Kangbok;Lee, Heyungsub
    • ETRI Journal
    • /
    • v.36 no.1
    • /
    • pp.141-150
    • /
    • 2014
  • A fully integrated CMOS security-enhanced passive (SEP) tag that compensates the security weakness of ISO/IEC 18000-6C is presented in this paper. For this purpose, we propose a security-enhanced protocol that provides mutual authentication between tag and reader. We show that the proposed protocol meets the security demands of the ongoing international standard for RFID secure systems, ISO/IEC 29167-6. This paper fabricates the SEP tag with a 0.18-${\mu}m$ CMOS technology and suggests the optimal operating frequency of the CMOS SEP tag to comply with ISO/IEC 18000-6C. Furthermore, we measure the SEP tag under a wireless environment. The measured results show that communications between the SEP tag and reader are successfully executed in both conventional passive and SEP modes, which follow ISO/IEC 18000-6C and the proposed security enhanced protocol, respectively. In particular, this paper shows that the SEP tag satisfies the timing link requirement specified in ISO/IEC 18000-6C.

The Study on the SEP (Standard Essential Patents) Procurement Strategy to accelerate the Trade Negotiation Competitiveness (통상 협상의 경쟁력 강화를 위한 표준특허 확보전략 연구)

  • Cho, Dongmin;Cho, Wongil
    • International Commerce and Information Review
    • /
    • v.18 no.4
    • /
    • pp.263-281
    • /
    • 2016
  • The Importance of SEP (Standard Essential Patents) Procurement Operation is on the side of Governmental and Public both to accelerate the national trade negotiation competitiveness. To operate cooperative system of SEP creation and management, Government should monitor the effect and performance periodically to public sectors. and To achieve the support objectives, it should establish the virtuous circle infrastructure between R&D and economic performance on SEP. This can make the SEP enhancement to pursue the international competitiveness on Intellectual Property Rights. Especially the specific support approach to each phase of the SEP declaration matrix is essential to consolidate the possibility of SEP creation and acquisition. In this study, the concepts of SEP to accelerate the national trade negotiation competitiveness and the prior research were verified through the investigation of market trend and current state of affair analysis. Through the analysis of international and domestic situation of SEP procurement and management, We have found the results as follows. First of all, the leading conglomerates and the Government should focus on the secondary and tertiary industries to create and acquire SEPs to accomplish the effectiveness of selection and concentration. In second, the SMEs and Univ. Labs should focus on the quaternary sector of the economy to retain the competitiveness of speed and challenge on SEP related. From this study, the appropriateness of the tailored-support management model should be institutionalized, and the results implied an research in order to examine the suitability among the current SEP to enhance the competitiveness of national trade research issues.

  • PDF

Change in shear bond strength of orthodontic brackets using self-etching primer according to adhesive types and saliva contamination (Self-etching primer를 사용하여 교정용 브라켓 접착 시 접착제와 타액오염에 따른 전단결합강도 변화)

  • Nam, Eun-Hye;Yoon, Young-Ah;Kim, Il-Kyu
    • The korean journal of orthodontics
    • /
    • v.35 no.6 s.113
    • /
    • pp.433-442
    • /
    • 2005
  • The purpose of this study was to evaluate and compare the shear bond strength of orthodontic brackets depending on the variety of adhesives and whether saliva exists, by using self-etching primer (SEP). Groups were divided according to the type of adhesive into resin adhesive (Trans bond XT) and resin-modified glass ionomer cement (Fuji Ortho LC). One group of resin adhesive used XT primer after etching with 37% phosphoric acid, and the other group used self-etching primer. One group of resin-modified glass ionomer cement only used etching for bonding, and the other group used SEP. Each of the groups were also classified by whether saliva was contaminated or not. and then the shear bond strength was measured. The results showed that when using resin adhesive, the shear bond strength of SEP was lower than the XT primer. In the resin-modified glass ionomer cement groups, the shear bond strength which depends on the priming method, did not have a meaningful difference statistically When saliva was contaminated, the group which used SEP, regardless of the adhesive variety, had a greater shear bond strength than the normal priming group. From these results, SEP showed a shear bond strength that is possible to be used clinically, regardless of the adhesive variety. It can especially be clinically useful to use SEP to bond brackets even on tooth surfaces contaminated with saliva, because it offers the appropriate bonding strength as well as shorter treatment time and easy application.

Rapid Preparation and Quality Control of $^{99m}Tc$-ECD, $MAG_3$ and MIBI using Microwave Heating and Sep-Pak Cartridges (마이크로웨이브와 Sep-Pak 카트리지를 이용한 $^{99m}Tc$-ECD, $MAG_3$, MIBI의 신속한 제조 및 정도관리)

  • Oh, Seung-Jun;Moon, Dae-Hyuk;Ryu, Jin-Sook;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.430-438
    • /
    • 1999
  • Purpose: We evaluated a rapid preparation procedures for the labeling and quality control of $^{99m}Tc$-ECD, $MAG_3$, and MIBI using microwave heating and Sep-Pak cartridges. Materials and Methods: $^{99m}Tc$ labeling of ECD, $MAG_3$, and MIBI kit preparation was performed according to the package inserts with microwave heating modification. Heating time was 10-15 sec, and heating was performed with 3 mm plastic bottle with screw cap to prevent radiation contamination. Labeling efficiency was obtained with $C_{18}$ or Alumina N Sep-Pak cartridges. Results: The radiochemical purity of $93{\sim}96%$ for $^{99m}Tc$-ECD and $95{\sim}99%$ for $^{99m}Tc$-MIBI was obtained using Alumina N Sep-Pak cartridge. The optimum irradiation time of microwave method for 3 ml $^{99m}Tc$-labeled radiopharmaceutical solution was 10 sec for $^{99m}Tc$-ECD and $^{99m}Tc$-MIBI, and 15 sec for $^{99m}Tc-MAG_3$. The results of quality control data with Sep-Pak cartridges were well correlated with TLC method. The total preparation time of these radiopharmcaeuticals was $5{\sim}6min$ including quality control procedure. Conclusion: This study demonstrates that radiopharmaceuticals preparation by microwave heating and quality control by Sep-Pak cartridges can be efficiently utilized as an alternative to the recommended method by manufacturer's manual.

  • PDF

Analysis of antigenic specificities of Puragonimus westeymuni developmental stages using immunoblot technique (Immunoblot technique을 이용한 폐흡충의 발육단계별 항원 특이성 분석)

  • 주경환;홍성철
    • Parasites, Hosts and Diseases
    • /
    • v.27 no.1
    • /
    • pp.1-8
    • /
    • 1989
  • Serodiagnosis of parasitic infections is widely used, since parasites or their eggs are not always detected by ordinary methods. The sensitive tests such as ELISA are highly dependent on the purity of antigens used. To solve this problem. many workers have tried to find species-specific components of antigens, The present study was performed to determine the antigenic profile of crude saline extracts of 3, 5, 8 and 12-week old p. westermani worms, which were collected from experimentally infected cats, based on SDS-PAGE and immunoblot technique. The results were as follows: 1. The SDS-PAGE showed at least 30 Protein bands ranging from 229 kDa to 10 kDa molecular weight. The protein components of p. wsstermani changed chronologically during its developmental period. The 229 kDa band was recognized only in 12-week old worms ($$SEP_{l2}$). 2. Analysis by ELISA showed a significant increase in antibody levels at 3 weeks in infected cats using crude saline extract antigens ($SEP_3,{\;}SEP_5,{\;}SEP_8,{\;}SEP_{l2}$). 3. By EITB using $SEP_3$ and $SEP_5$ infected cats recognisea major protein bands with molecular weight of 60, 35, 28, 25 or 21 kDa at 3~12 weeks of infection, and 3 additional antigens, 19, 13 and 10 kDa, were detected at 8~12 weeks of infections. 4. Using $SEP_8$ 5 antigens, 91, 85, 31, 25 and 21 kDa, were consistently detected by all infected sera tested. In addition, 3 antigens of lg. 13 and 10 kDa were detected at 8~12 weeks of infection. Using $SEP_12$, similar results were obtained with that by using $SEP_8$ and 1 additional antigen of 229 kDa, specifically reacting with the sera from 12 weeks of in(traction, was recognized.

  • PDF

Cell Proliferation and Motility Are Inhibited by G1 Phase Arrest in 15-kDa Selenoprotein-Deficient Chang Liver Cells

  • Bang, Jeyoung;Huh, Jang Hoe;Na, Ji-Woon;Lu, Qiao;Carlson, Bradley A.;Tobe, Ryuta;Tsuji, Petra A.;Gladyshev, Vadim N.;Hatfield, Dolph L.;Lee, Byeong Jae
    • Molecules and Cells
    • /
    • v.38 no.5
    • /
    • pp.457-465
    • /
    • 2015
  • The 15-kDa selenoprotein (Sep15) is a selenoprotein residing in the lumen of the endoplasmic reticulum (ER) and implicated in quality control of protein folding. Herein, we established an inducible RNAi cell line that targets Sep15 mRNA in Chang liver cells. RNAi-induced Sep15 deficiency led to inhibition of cell proliferation, whereas cell growth was resumed after removal of the knockdown inducer. Sep15-deficient cells were arrested at the G1 phase by upregulating p21 and p27, and these cells were also characterized by ER stress. In addition, Sep15 deficiency led to the relocation of focal adhesions to the periphery of the cell basement and to the decrease of the migratory and invasive ability. All these changes were reversible depending on Sep15 status. Rescuing the knockdown state by expressing a silent mutant Sep15 mRNA that is resistant to siRNA also reversed the phenotypic changes. Our results suggest that SEP15 plays important roles in the regulation of the G1 phase during the cell cycle as well as in cell motility in Chang liver cells, and that this selenoprotein offers a novel functional link between the cell cycle and cell motility.

Scan Element Characteristics of Open-Ended Waveguide Array Antenna (개방형 도파관 배열안테나의 조향소자 특성)

  • Kim, Dong-Seok;Kim, Tae-Hyun;Park, Dong-Chul;Kim, Chan-Hong
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.347-352
    • /
    • 2005
  • Scan Element Pattern(SEP) and Scan Impedance(SI) concepts are used to analyze the characteristics of open-ended waveguide array, which is the representative phased array antenna element in C-band and X-band. Transmit SEP's are calculated for 15$\sim$15 subarray and SI's are obtained by applying periodic boundary conditions for a unit cell of the given array condition. CST's MWS and Ansoft's HFSS are utilized for each analysis. Some relations are reviewed between the two results, which are based on mutual coupling effects. For validation purpose, an 8$\sim$8 subarray is constructed and tested. Transmit SEP measured in MTG's far-field range shows good agreement with the calculated transmit SEP.

  • PDF

Computing the Average Symbol Error Probability of the MPSK System Having Quadrature Error

  • Park, Seung-Keun;Cho, Sung-Ho
    • ETRI Journal
    • /
    • v.28 no.6
    • /
    • pp.793-795
    • /
    • 2006
  • When quadrature error exists, the shape of the M-ary phase shift keying (MPSK) signal constellation becomes skewed-elliptic. Each MPSK symbol takes on a different symbol error probability (SEP) value. The analytical results presented thus far have been derived from studies which examined the SEP problem assuming that the SEP of each MPSK symbol is equally likely; therefore, those results should not be treated as offering a complete solution. In this letter, we present a new and more complete solution to the SEP problem of MPSK by relaxing the above assumption and finding the expressions for the average as well as individual SEP in the presence of quadrature error.

  • PDF

Measurement of Socioeconomic Position in Research on Cardiovascular Health Disparities in Korea: A Systematic Review

  • Lee, Chi-Young;Lee, Yong-Hwan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.52 no.5
    • /
    • pp.281-291
    • /
    • 2019
  • Objectives: The validity of instruments measuring socioeconomic position (SEP) has been a major area of concern in research on cardiovascular health disparities. The purpose of this systematic review is to identify the current status of the methods used to measure SEP in research on cardiovascular health disparities in Korea and to provide directions for future research. Methods: Relevant articles were obtained through electronic database searches with manual searches of reference lists and no restriction on the date of publication. SEP indicators were categorized into compositional, contextual, composite, and life-course measures. Results: Forty-eight studies published from 2003 to 2018 satisfied the review criteria. Studies utilizing compositional measures mainly relied on a limited number of SEP parameters. In addition, these measures hardly addressed the time-varying and subjective features of SEP. Finding valid contextual measures at the organizational, community, and societal levels that are appropriate to Korea's context remains a challenge, and these are rarely modeled simultaneously. Studies have rarely focused on composite and life-course measures. Conclusions: Future studies should develop and utilize valid compositional and contextual measures and appraise social patterns that vary across time, place, and culture using such measures. Studies should also consider multilevel influences, adding a focus on the interactions between different levels of intertwined SEP factors to advance the design of research. More attention should be given to composite and life-course measures.