• Title/Summary/Keyword: SEM(Scanning Electron Microscope)

Search Result 1,875, Processing Time 0.031 seconds

Synthesis of Inorganic/Organic Core-Shell Polymer Using Polyoxyethylene Alkylether Sulfate as a Surfactant (Polyoxyethylene Alkylether Sulfate 계면활성제를 사용한 무기/유기 코어-셀의 합성)

  • Kim, Duck-Sool;Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.27 no.1
    • /
    • pp.93-97
    • /
    • 2010
  • Silicone dioxide absorbed polyoxyethylene alkylether sulfate (EU-S75D) surfactant was prepared. The core-shell composite of inorganic/organic were polymerized by using styrene(St) as a shell monomer and potassium persulfate(KPS) as an initiator. We studied the effect of surfactants on the core-shell structure of silicone dioxide/styrene in the presence of an anionic surfactant lauryl sulfate(SLS). The structure of core-shell polymer were investigated by measuring to the thermal decomposition of polymer composite using thermogravimetric analyzer(TGA) and morphology of latex by scanning electron microscope(SEM).

A Study on Material Characterization and Mechanical Properties of SMC Compression Molding Parts (SMC 압축성형재의 기계적 물성 및 특성에 관한 연구)

  • 김기택;임용택
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.9
    • /
    • pp.2396-2403
    • /
    • 1994
  • An experimental study on material characterization and mechanical properties of SMC(Sheet Molding Compounds) compression method parts was carried out. Simple compression test using grease oil as a lubricant was carried out to characterize flow stress of SMC at elevated temperatures. Two different mold temperatures, $130^{\circ}C{\;}and{\;}150^{\circ}C$ and two different mold speeds, 15, 45 mm/min were used for preparing the specimen of SMC compression molded parts. Surface roughness, tensile, and 3-point bending tests were used to determine the effects of molding temperatures and speeds on mechanical properties of compression molded SMC parts. Orientation and distribution of glass fiber in the compression molded SMC parts were also investigated by photographing the burnt flat specimen and taking SEM(Scanning Electron Microscope) of cross-sectional T-specimen.

Studies on the Character of Ant(Formicidae) in Korea on the Basis of Scanning Electron Microscope(I) -On the Form-Character of Smithistruma japonica(Ito)- (주사전자현미경을 이용한 한국산 개미의 형질특성에 관한 연구(I) -Smithistruma japonica(Ito)의 형질특성에 관하여-)

  • 김창효;최병문;방종렬
    • Korean journal of applied entomology
    • /
    • v.30 no.4
    • /
    • pp.285-290
    • /
    • 1991
  • Smithistruma japonica(lto) unrecorded species of Dacetini tribe in Korea was found in Is. Kekumdo, Chonnam Province and named Saw teeth scale ant. The form-characteristics difference between Smithistruma japonica(Ito) and Strumigenys lewisi Cameron was discribed with the result of observation by the scanning electron microscope(SEM). Total species of Dacetini tribe in Korean contained two species in two genus.

  • PDF

Characterization of Surface at Ti Oxide Films Converted by Anodic Spark Discharge (양극산화 불꽃 방전에 의한 Ti 산화피막의 표면특성)

  • Song, Jae-Joo;Han, Byung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.545-546
    • /
    • 2006
  • This study was performed to investigate the surface properties of electrochemically oxidized pure titanium by anodic spark discharging method. Commercially pure titanium plates of $10{\times}20{\times}1[mm]$ in dimensions were polished sequentially emery paper. Anodizing was performed at current density of $76.2\;[mA/cm^2]$, application voltage of 290, 350, 400 [V] using a regulated DC power supply, which allowed automatic transition constant current when a preset maximum voltage has been reached. The Ti surface oxided films was characterized by scanning electron microscope(SEM). The precipitation of HA(Hydroxyapatite) crystals on anodized surface was greatly accelerated by hydrothermal treatment. The concentrations of DL-$\alpha$-Glycerolphosphate Magnesiurn(DL-$\alpha$-GP-Mg) salt and Ca acetate in an electrolyte was highly affected the precipitation of HA crystals converted by Ti Anodized oxide films by Shape of Impulse Voltage.

  • PDF

Characterization of Nano-Grained ZnO Piezoelectric Thin Films Deposited under Various Sputtering Conditions

  • Zhang, Ruirui;Lee, Eunju;Yoon, Giwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.428-430
    • /
    • 2009
  • C-axis-oriented ZnO thin films were successfully deposited on p-Si (100) in an RF magnetron sputtering system. Deposition conditions such as deposition power, working pressure, and oxygen gas ratio were varied. Crystalline structures of the deposited ZnO films were investigated by a scanning electron microscope (SEM) technique. Results show that the deposition parameters can have a strong impact on the preferred orientations and grain sizes of the deposited ZnO films.

  • PDF

Conductivity of copper(II)-phthalocyanine thin films due to a grain growth (결정 성장 조건에 따른 copper(II)-phthalocyanine 박막의 전기전도도 특성)

  • Park, Mie-Hwa;Yoo, Hyun-Jun;Lee, Kie-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.132-136
    • /
    • 2004
  • 열 증착 방법을 이용하여 copper(II)-phthalocyanine(CuPc) 박막을 glass 기판 위에 제작하였다. 열처리 조건은 $150^{\circ}C$에서 후열(annealing) 처리 하는 방식과 예열하는 두 가지 방식으로 달리하였다. 제작된 박막의 전기전도도를 평가하기 위해 마이크로웨이브 근접장 효과를 이용한 근접장 현미경(near-field scanning microwave microscope)을 이용하여 비파괴적인 방식으로 CuPc 박막의 반사계수(reflection coefficient)를 측정하였다. CuPc 박막의 전기전도도 특성을 UV 흡수도를 통한 에너지 밴드갭의 shift 현상과 관련지어 설명하고 또한 x-ray diffraction(XRD) data를 통해 박막의 결정 특성과 비교하였다. 박막 표면 특성은 SEM(scanning microscope microscopy)을 통해 관측하였다. 열처리 조건에 따른 CuPc 박막의 전기전도도 특성은 후열 처리한 박막의 경우 예열 처리한 박막보다 전기 전도 특성이 향상되었음을 관측할 수 있었다.

  • PDF

In vitro effect of praziquantel on Heterophyopsis continua by scanning electron microscopic observation (Heterophyopsis continua에 대한 praziquantel 시험관내 효과의 주사현미경적 관찰)

  • Woo, Ho-choon;Suh, Myung-deuk;Hong, Sung-jong
    • Korean Journal of Veterinary Research
    • /
    • v.30 no.4
    • /
    • pp.487-497
    • /
    • 1990
  • This study was carried out to observe in vitro effect of praziquantel on the tegumental changes of Heterophyopsis continua with scanning electron microscope. Metacercariae were collected from the perch, Lateolabrax japonicus, by artificial digestion technique and fed to 2-week old chickens. Adult worms were recovered from small intestine of chickens 8 days after infection. For working solutions, praziquantel was diluted with TC199 medium at concentration of 0.01, 0.1. 1 and $10{\mu}g/ml$. To each petri dish containing 10ml of solution, 5~10 worms were introduced and incubated at $37^{\circ}C$. For the scanning electron microscopy(SEM), the worms were fixed in cold 2.5% glutaraldehyde, dehydrated in a series of graded ethanol and freeze-dried. Dried specimen was mounted on stub and coated with gold and observed in an SEM. The results were as follows: 1. Severe tegumental alterations were recognized by scanning electron microscope. Bleb formation of tegument was observed in 5 minute group and most pronounced on anterior tegument of worms. The number and size of blebs increased as incubation time prolonged. 2. The surface destruction was more pronounced at ventral margin between the oral and the ventral suckers. 3. The sensory papillae were slightly affected, but destruction of tegumental spine was not recognized. 4. The effect of praziquantel on the worm was found dependent on the concentration and incubation time, however, the effect was more dependent upon the incubation time.

  • PDF

Cryo-SEM Methodology of Arabidopsis thaliana Stem Using High-Pressure Freezing (고압동결고정을 이용한 애기장대 줄기의 cryo-SEM 분석법)

  • Choi, Yun-Joung;Lee, Kyung-Hwan;Je, A-Reum;Chae, Hee-Su;Jang, Ji-Hoon;Lee, Eun-Ji;Kweon, Hee-Seok
    • Applied Microscopy
    • /
    • v.42 no.2
    • /
    • pp.111-114
    • /
    • 2012
  • The scanning electron microscopy is an ideal technique for examining plant surface at high resolution. Most hydrate samples, however, must be fix and dehydrate for observation in the scanning electron microscope. Because the microscopes operate under high vacuum, most specimens, especially biological samples, cannot withstand water removal by the vacuum system without morphological distortion. Cryo-techniques can observe in their original morphology and structure without various artifacts from conventional sample preparation. Rapid cooling is the method of choice for preparing plant samples for scanning electron microscopy in a defined physiological state. As one of cryo-technique, high-pressure freezing allows for fixation of native non-pretreated samples up to $200{\mu}M$ thick and 2 mm wide with minimal or no ice crystal damage for the freezing procedure. In this study, we could design to optimize structural preservation and imaging by comparing cryo-SEM and convention SEM preparation, and observe a fine, well preserved Arabidopsis stem's inner ultrastructure using HPF and cryo-SEM. These results would suggest a useful method of cryo-preparation and cryo-SEM for plant tissues, especially intratubule and vacuole rich structure.

Study about The Effect Alcohol and The Temperature Exert on $TiO_2$ Particle Production by Sedimentation Method (침전법을 이용한 이산화티탄 입자 제조에 알콜과 온도가 미치는 영향에 관한 연구)

  • Kim, Duck-Sool
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.495-502
    • /
    • 2012
  • Using the Sedimentation method it's possible to get $TiO_2$ particle from which by this research, $TiO_2$ particle was produced. The parameter in the kind of the temperature and the alcohol solvent used $TiO_2$ particle production investigated crystal structure of $TiO_2$ particle and the influence exerted on the size of the particle and the form. After scanning electron microscope (SEM) analyzed methyl alcohol, iso-propylalcohol and tert-butylalcohol used by a solvent at the $TiO_2$ particle production, iso-propylalcohol was most effective. And after an thermogravimetric analyzer method was used, the anatase structure was maintained $500^{\circ}C$ by $200^{\circ}C$, but it was converted by the rutile structure by $800^{\circ}C$.

Structure of a Plasma Ion Source for a Cross-Section SEM Sample (SEM 단면 시료 제작을 위한 플라즈마 이온원의 구조)

  • Won, Jong-Han;Jang, Dong-Young;Park, Man-Jin
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.4
    • /
    • pp.400-406
    • /
    • 2015
  • This study researched the structure of the source of an ion milling machine used to fabricate a scanning electron microscope (SEM) sample. An ion source is used to mill out samples of over 1 mm dimension using a broad ion beam to generate plasma between the anode and cathode using a permanent magnet. To mill the sample in the vacuum chamber, the ion source should be greater than 6 kV for a positive ion current over $200{\mu}A$. To discover the optimum operating conditions for the ion miller, the diameter of the extractor, anode shape, and strength of the permanent magnet were varied in the experiments. A silicon wafer was used as the sample. The sputter yield was measured on the milled surface, which was analyzed using the SEM. The wafer was milled by injecting 1 sccm of argon gas into the 0.5 mTorr vacuum chamber.