• 제목/요약/키워드: SEC

Search Result 6,484, Processing Time 0.034 seconds

Unenhanced Breast MRI With Diffusion-Weighted Imaging for Breast Cancer Detection: Effects of Training on Performance and Agreement of Subspecialty Radiologists

  • Yeon Soo Kim;Su Hyun Lee;Soo-Yeon Kim;Eun Sil Kim;Ah Reum Park;Jung Min Chang;Vivian Youngjean Park;Jung Hyun Yoon;Bong Joo Kang;Bo La Yun;Tae Hee Kim;Eun Sook Ko;A Jung Chu;Jin You Kim;Inyoung Youn;Eun Young Chae;Woo Jung Choi;Hee Jeong Kim;Soo Hee Kang;Su Min Ha;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.25 no.1
    • /
    • pp.11-23
    • /
    • 2024
  • Objective: To investigate whether reader training improves the performance and agreement of radiologists in interpreting unenhanced breast magnetic resonance imaging (MRI) scans using diffusion-weighted imaging (DWI). Materials and Methods: A study of 96 breasts (35 cancers, 24 benign, and 37 negative) in 48 asymptomatic women was performed between June 2019 and October 2020. High-resolution DWI with b-values of 0, 800, and 1200 sec/mm2 was performed using a 3.0-T system. Sixteen breast radiologists independently reviewed the DWI, apparent diffusion coefficient maps, and T1-weighted MRI scans and recorded the Breast Imaging Reporting and Data System (BI-RADS) category for each breast. After a 2-h training session and a 5-month washout period, they re-evaluated the BI-RADS categories. A BI-RADS category of 4 (lesions with at least two suspicious criteria) or 5 (more than two suspicious criteria) was considered positive. The per-breast diagnostic performance of each reader was compared between the first and second reviews. Inter-reader agreement was evaluated using a multi-rater κ analysis and intraclass correlation coefficient (ICC). Results: Before training, the mean sensitivity, specificity, and accuracy of the 16 readers were 70.7% (95% confidence interval [CI]: 59.4-79.9), 90.8% (95% CI: 85.6-94.2), and 83.5% (95% CI: 78.6-87.4), respectively. After training, significant improvements in specificity (95.2%; 95% CI: 90.8-97.5; P = 0.001) and accuracy (85.9%; 95% CI: 80.9-89.8; P = 0.01) were observed, but no difference in sensitivity (69.8%; 95% CI: 58.1-79.4; P = 0.58) was observed. Regarding inter-reader agreement, the κ values were 0.57 (95% CI: 0.52-0.63) before training and 0.68 (95% CI: 0.62-0.74) after training, with a difference of 0.11 (95% CI: 0.02-0.18; P = 0.01). The ICC was 0.73 (95% CI: 0.69-0.74) before training and 0.79 (95% CI: 0.76-0.80) after training (P = 0.002). Conclusion: Brief reader training improved the performance and agreement of interpretations by breast radiologists using unenhanced MRI with DWI.

Tumor Margin Infiltration in Soft Tissue Sarcomas: Prediction Using 3T MRI Texture Analysis (연조직 육종의 종양 가장자리 침윤: 3T 자기공명영상 텍스처 분석을 통한 예측)

  • Minji Kim;Won-Hee Jee;Youngjun Lee;Ji Hyun Hong;Chan Kwon Jung;Yang-Guk Chung;So-Yeon Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.112-126
    • /
    • 2022
  • Purpose To determine the value of 3 Tesla (T) MRI texture analysis for predicting tumor margin infiltration in soft tissue sarcomas. Materials and Methods Thirty-one patients who underwent 3T MRI and had a pathologically confirmed diagnosis of soft tissue sarcoma were included in this study. Margin infiltration on pathology was used as the gold standard. Texture analysis of soft tissue sarcomas was performed on axial T1-weighted images (WI) and T2WI, fat-suppressed contrast-enhanced (CE) T1WI, diffusion-weighted images (DWI) with b-value of 800 s/mm2, and apparent diffusion coefficient (ADC) was mapped. Quantitative parameters were compared between sarcomas with infiltrative margins and those with circumscribed margins. Results Among the 31 patients with soft tissue sarcomas, 23 showed tumor margin infiltration on pathology. There were significant differences in kurtosis with the spatial scaling factor (SSF) of 0 and 6 on T1WI, kurtosis (SSF, 0) on CE-T1WI, skewness (SSF, 0) on DWI, and skewness (SSF, 2, 4) on ADC between sarcomas with infiltrative margins and those with circumscribed margins (p ≤ 0.046). The area under the receiver operating characteristic curve based on MR texture features for identification of infiltrative tumor margins was 0.951 (p < 0.001). Conclusion MR texture analysis is reliable and accurate for the prediction of infiltrative margins of soft tissue sarcomas.

Weaning Following a 60 Minutes Spontaneous Breathing Trial (1시간 자가호흡관찰에 의한 기계적 호흡치료로부터의 이탈)

  • Park, Keon-Uk;Won, Kyoung-Sook;Koh, Young-Min;Baik, Jae-Jung;Chung, Yeon-Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.3
    • /
    • pp.361-369
    • /
    • 1995
  • Background: A number of different weaning techniques can be employed such as spontaneous breathing trial, Intermittent mandatory ventilation(IMV) or Pressure support ventilation(PSV). However, the conclusive data indicating the superiority of one technique over another have not been published. Usually, a conventional spontaneous breathing trial is undertaken by supplying humidified $O_2$ through T-shaped adaptor connected to endotracheal tube or tracheostomy tube. In Korea, T-tube trial is not popular because the high-flow oxygen system is not always available. Also, the timing of extubation is not conclusive and depends on clinical experiences. It is known that to withdraw the endotracheal tube after weaning is far better than to go through any period. The tube produces varying degrees of resistance depending on its internal diameter and the flow rates encountered. The purpose of present study is to evaluate the effectiveness of weaning and extubation following a 60 minutes spontaneous breathing trial with simple oxygen supply through the endotracheal tube. Methods: We analyzed the result of weaning and extubation following a 60 minutes spontaneous breathing trial with simple oxygen supply through the endotracheal tube in 18 subjects from June, 1993 to June, 1994. They consisted of 9 males and 9 females. The duration of mechanical ventilation was from 38 hours to 341 hours(mean: $105.9{\pm}83.4$ hours). In all cases, the cause of ventilator dependency should be identified and precipitating factors should be corrected. The weaning trial was done when the patient became alert and arterial $O_2$ tension was adequate($PaO_2$ > 55mmHg) with an inspired oxygen fraction of 40%. We conducted a careful physical examination when the patient was breathing spontaneously through the endotracheal tube. Failure of weaning trial was signaled by cyanosis, sweating, paradoxical respiration, intercostal recession. Weaning failure was defined as the need for mechanical ventilation within 48 hours. Results: In 19 weaning trials of 18 patients, successful weaning and extubation was possible in 16/19(84.2 %). During the trial of spontaneous breathing for 60 minutes through the endotracheal tube, the patients who could wean developed slight increase in respiratory rates but significant changes of arterial blood gas values were not noted. But, the patients who failed weaning trial showed the marked increase in respiratory rates without significant changes of arterial blood gas values. Conclusion: The result of present study indicates that weaning from mechanical ventilation following a 60 minutes spontaneous breathing with $O_2$ supply through the endotracheal tube is a simple and effective method. Extubation can be done at the same time of successful weaning except for endobronchial toilet or airway protection.

  • PDF

The comparison of lesion localization methods in breast lymphoscintigraphy (Breast lymphoscintigraphy 검사 시 체표윤곽을 나타내는 방법의 비교)

  • Yeon, Joon ho;Hong, Gun chul;Kim, Soo yung;Choi, Sung wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.74-80
    • /
    • 2015
  • Purpose Breast lymphoscintigraphy is an important technique to present for body surface precisely, which shows a lymph node metastasis of malignant tumors at an early stage and is performed before and after surgery in patients with breast cancer. In this study, we evaluated several methods of body outline imaging to present exact location of lesions, as well as compared respective exposure doses. Materials and Methods RANDO phantom and SYMBIA T-16 were used for obtaining imaging. A lesion and an injection site were created by inserting a point source of 0.11 MBq on the axillary sentinel lymph node and 37 MBq on the right breast, respectively. The first method for acquiring the image was used by drawing the body surface of phantom for 30 sec using $Na^{99m}TcO_4$ as a point source. The second, the image was acquired with $^{57}Co$ flood source for 30 seconds on the rear side and the left side of the phantom, the image as the third method was obtained using a syringe filled with 37 MBq of $Na^{99m}TcO_4$ in 10 ml of saline, and as the fourth, we used a photon energy and scatter energy of $^{99m}Tc$ emitting from phantom without any addition radiation exposure. Finally, the image was fused the scout image and the basal image of SPECT/CT using MATLAB$^{(R)}$ program. Anterior and lateral images were acquired for 3 min, and radiation exposure was measured by the personal exposure dosimeter. We conducted preference of 10 images from nuclear medicine doctors by the survey. Results TBR values of anterior and right image in the first to fifth method were 334.9 and 117.2 ($1^{st}$), 266.1 and 124.4 ($2^{nd}$), 117.4 and 99.6 ($3^{rd}$), 3.2 and 7.6 ($4^{th}$), and 565.6 and 141.8 ($5^{th}$). And also exposure doses of these method were 2, 2, 2, 0, and $30{\mu}Sv$, respectively. Among five methods, the fifth method showed the highest TBR value as well as exposure dose, where as the fourth method showed the lowest TBR value and exposure dose. As a result, the last method ($5^{th}$) is the best method and the fourth method is the worst method in this study. Conclusion Scout method of SPECT/CT can be useful that provides the best values of TBR and the best score of survey result. Even though personal exposure dose when patients take scout of SPECT/CT was higher than another scan, it was slight level comparison to 1 mSv as the dose limit to non-radiation workers. If the scout is possible to less than 80 kV, exposure dose can be reduced, and also useful lesion localization provided.

  • PDF

A Comparative Analysis of GBEF According to Image Aquisition Method in Hepatobiliary Scan (간담도스캔의 영상수집방법에 따른 담즙배출율의 비교분석)

  • Kim, Yeong-Seon;Seo, Myeong-Deok;Lee, Wan-Kyu;Song, Jae-Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.8-16
    • /
    • 2014
  • Purpose The quantitative analysis of gallbladder emptying is very important in diagnosis of motility disorder of gallbladder and in biliary physiology. The GBEF obtain the statics aquisition method or the dynamic acquisition method in two ways. The purpose of this study is to compare the GBEF value of statics acquisition method and the dynamic acquisition method. And we find the best way for calculate GBEF. Materials and Methods The quantitative hepatobiliary scan with $^{99m}Tc$-mebrofenin was performed of 27 patients. Initial images were acquired statically, for 60 min after injection of the radioactive tracer. And if the gallbladder is visualized to 60 min, performed stimulation of gallbladder (1egg, 200 mL milk). After that, started acquisition of dynamic image for 30 min. After that, image of after fatty meal of the statics method were acquired on equal terms with 60 min image. The statics GBEF was calculated using the images of before fatty meal and post fatty meal by the statics method. The dynamic GBEF was calculated using the images of time of maximum bile juice uptake ($T_{max}$) and time of minimum bile juice uptake ($T_{min}$) images from the gallbladder time-activity curve. A bile juice is secreted from gallbladder while eating a fatty meal. that is named early GBEF and that was calculated using before fatty meal image of the statics method and 1 min image of the dynamic method. Results The result saw very big difference between two according to $T_{max}$. The result, were as follows. 1) In case of less than 1 min, the dynamic mean GBEF was $40.1{\pm}21.7%$, the statics mean GBEF was $51.5{\pm}23.6%$ in 16 cases. The early mean GBEF was $14.0{\pm}29.1%$. The GBEF of statics method was higher because that include secreted bile juice while performed stimulation of gallbladder. A difference of GB counts according to acquisition method and the early bile juice counts was $17.6{\pm}14.8%$ and $13.5{\pm}15.3%$. 2) In case of exceed than 1 min, the dynamic mean GBEF was $31.0{\pm}19.7%$, the statics mean GBEF was $21.3{\pm}19.4%$ in 7 cases. The early GBEF was $-6.9{\pm}4.9%$. The GBEF of dynamic method was higher because that include concentrated bile juice to $T_{max}$. A difference of GB counts according to acquisition method and the early bile juice counts was $14.3{\pm}7.3%$ and $5.9{\pm}3.9%$. Conclusion The statics method is very easy and simple, but in case of $T_{max}$ delay, the GBEF can be lower. The dynamic method is able to calculate accurately in case of $T_{max}$ delay, but in case of $T_{max}$ is less than 1 min, the GBEF can be lower because dynamic GBEF exclude secreted bile juice while performed stimulation of gallbladder. The best way to calculate GBEF is to scan with dynamic method preferentially and to choose suitable method between the two way after conform $T_{max}$ on the T-A curve of the dynamic method.

  • PDF

One-stop Evaluation Protocol of Ischemic Heart Disease: Myocardial Fusion PET Study (허혈성 심장 질환의 One-stop Evaluation Protocol: Myocardial Fusion PET Study)

  • Kim, Kyong-Mok;Lee, Byung-Wook;Lee, Dong-Wook;Kim, Jeong-Su;Jang, Yeong-Do;Bang, Chan-Seok;Baek, Jong-Hun;Lee, In-Su
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.33-37
    • /
    • 2010
  • Purpose: In the early stage of using PET/CT, it was used to damper revision but recently shows that CT with MDCT is commonly used and works well for an anatomical diagnosis. This hospital makes the accuracy and convenience more higher in the diagnosis and evaluate of coronary heart disease through concurrently running myocardial perfusion SPECT examination, myocardial PET examination with FDG, and CT coronary artery CT angiography(coronary CTA) used PET/CT with 64-slice. This report shows protocol and image based on results from about 400 coronary heart disease examinations since having 64 channels PET/CT in July 2007. Materials and Methods: An Equipment for this examination is 64-slice CT and Discovery VCT (DVCT) that is consisted of PET with BGO ($Bi_4Ge_3O_{12}$) scintillation crystal by GE health care. First myocardial perfusion SPECT with pharmacologic stress test to reduce waiting time of a patient and get a quick diagnosis and evaluation, and right after it, myocardial FDG PET examination and coronary CTA run without a break. One-stop evaluation protocol of ischemic heart disease is as follows. 1)Myocardial perfusion SPECT with pharmacologic stress: A patient is injected with $^{99m}Tc$-MIBI 10 mCi and does not have any fatty food for myocardial PET examination and drink natural water with ursodeoxcholic acid 100 mg and we get SPECT image in an hour. 2)Myocardial FDG PET: To reduce blood fatty content and to increase uptake of FDG, we used creative oral glucose load using insulin and Acipimox to according to blood acid content. A patient is injected with $^{18}F$-FDG 5 mCi for reduction of his radiation exposure and we get a gated image an hour later and get delay image when we need. 3) Coronary CTA: The most important point is to control heart rate and to get cooperation of patient's breath. In order to reduce a heart rate of him or her below 65 beats, let him or her take beta blocker 50 mg ~ 200 mg after a consultation with a doctor about it and have breath-practices then have the examination. Right before the examination, we spray isosorbide dinitrate 3 to 5 times to lower tension of bessel wall and to extension a blood wall of a patient. It makes to get better the shape of an anatomy. At filming, a patient is injected CT contrast with high pressure and have enough practices before the examination in order to have no problem. For reduction of his radiation exposure, we have to do ECG-triggered X-ray tube modulation exposure. Results: We evaluate coronary artery stenosis through coronary CTA and study correlation (culprit vessel check) of a decline between stenosis and perfusion from the myocardial perfusion SPECT with pharmacologic stress, coronary CTA, and can check viability of infarction or hibernating myocardium by FDG PET. Conclusion: The examination makes us to set up a direction of remedy (drug treatment, PCI, CABG) because we can estimate of effect from remedy, lesion site and severity. In addition, we have an advantage that it takes just 3 hours and one-stop in that all of process of examinations run in succession and at the same time. Therefore it shows that the method is useful in one stop evaluation of ischemic heart disease.

  • PDF

Comparison of Treadmill and Cycle Ergometer in Male Korean College Students (한국 남자 대학생을 대상으로 시행한 Cardiopulmonary Exercise Test에서 Treadmill과 Cycle Ergometer의 비교 분석)

  • Chang, Yoon-Soo;Park, Jae-Min;Choi, Seung-Won;Ahn, Gang-Hyun;Lee, Jun-Gu;Yang, Dong-Kyu;Kim, Se-Kyu;Chang, Jun;Ahn, Chul-Min;Kim, Seong-Kyu;Lee, Won-Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.1
    • /
    • pp.26-34
    • /
    • 1999
  • Background : Generally $VO_2$ max is higher in treadmill exercise than cycle ergometer exercise. According to Hassen and Wasserman, $VO_2$ max with treadmill exercise is higher at ratio of 1.11 than that with cycle ergometer. $VO_2$ max also is influenced by race, sociocultural background, exercise habit In this study, $VO_2$ max and AT were evaluated between Treadmill and cycle exercise in male Korean college students. Method: Study subjects were 44 male college students. We randomized them into 2 groups; 24 students did treadmill exercise at first and 1 week later did cycle ergometer. Another 20 students did in opposite method. They made symptom limited maximal exercise. Author defined maximal exercise as followings: 1) respiratory exchange ratio(RER)> 1.1, 2) plateau>30 sec, 3) heart rate reserve(HRR) <15%, or 4) breathing reserve (BR)<30%. Otherwise their results are excluded as submaximal exercise. Anaerobic threshold(AT) was estimated by V-slope method. Results: $VO_2$ max and AT was $45.1{\pm}6.66m\ell$/kg/min and $26.0{\pm}6.78m\ell$/kg/min in treadmill and $34.9{\pm}5.89m\ell$/kg/min, $19.5{\pm}4.77m\ell$/kg/min in Cycle Ergometer. The measured-$VO_2max$/pred-$VO_2max$ was $98.8{\pm}13.24%$ in treadmill; $84.4{\pm}13.42%$ in cycle ergometer. Comparing $VO_2$ max in treadmill with that obtained by Hassen's method, there were significant differences.(p<0.01). At maximal exercise there were differences in HRR, $O_2$/pulse, BR, $V_E$/MVV, $V_E/VCO_2$ between treadmill and cycle but not in $V_E/VO_2$, Vd/Vt, Ti/Ttot. At AT there were differences in $O_2$/pulse, BR, $V_E$/MVV, Ti/Ttot between treadmill and cycle, otherwise not. Conclusion: According to the result of this study, there are larger gap between treadmill and cycle ergometer in normal Korean adults than foreign data, and it needs further study to obtain reference value of Korea.

  • PDF

Peak Expiratory Flow(PEF) Measured by Peak Flow Meter and Correlation Between PEF and Other Ventilatory Parameters in Healthy Children (정상 소아에서 최고호기유량계(peak flow meter)로 측정한 최고호기유량(PEF)와 기타 환기기능검사와의 상관관계)

  • Oak, Chul-Ho;Sohn, Kai-Hag;Park, Ki-Ryong;Cho, Hyun-Myung;Jang, Tae-Won;Jung, Maan-Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.3
    • /
    • pp.248-259
    • /
    • 2001
  • Background : In diagnosis or monitor of the airway obstruction in bronchial asthma, the measurement of $FEV_1$ in the standard method because of its reproducibility and accuracy. But the measurement of peak expiratory flow(PEF) by peak flow meter is much simpler and easier than that of $FEV_1$ especially in children. Yet there have been still no data of the predicted normal values of PEF measured by peak flow meter in Korean children. This study was conducted to provide equations to predict the normal value of PEF and correlation between PEF and $FEV_1$ in healthy children. Method : PEF was measured by MiniWright peak flow meter, and the forced expiratory volume and the maximum expiratory flow volume curves were measured by Microspiro HI 501(Chest Co.) in 346 healthy children(age:5-16 years, 194 boys and 152 girls) without any respiratory symptoms during 2 weeks before the study. The regression equations for various ventilatory parameters according to age and/or height, and the regression equations of $FEV_1$ by PEF were derived. Results : 1. The regression equation for PEF(L/min) was: $12.6{\times}$age(year)+$3.4{\times}$height(cm)-263($R^2=0.85$) in boys, and $6{\times}$age(year)+$3.9{\times}$height(cm)-293($R^2=0.82$) in girls. 2. The value of FEFmax(L/sec) derived from the maximum expiratory flow volume curves was multiplied by 60 to compare with PEF(L/min), and PEF was faster by 125 L/min in boys and 118 L/min in girls, respectively. 3. The regression equation for $FEV_1$(ml) by PEF(L/min) was:$7{\times}$PEF-550($R^2=0.82$) in boys, and $5.8{\times}$PEF-146 ($R^2=0.81$) in girls, respectively. Conclusion : This study provides regression equations predicting the normal values of PEF by age and/or height in children. And the equations for $FEV_1$, a gold standard of ventilatory function, was predicted by PEF. So, in taking care of children with airway obstruction, PEF measured by the peak flow meter can provide useful information.

  • PDF

Effect of Pressure Rise Time on Tidal Volume and Gas Exchange During Pressure Control Ventilation (압력조절환기법에서 압력상승시간(Pressure Rise Time)이 흡기 일환기량 및 가스교환에 미치는 영향)

  • Jeoung, Byung-O;Koh, Youn-Suck;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Lim, Chae-Man
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.5
    • /
    • pp.766-772
    • /
    • 2000
  • Background : Pressure rise time (PRT) is the time in which the ventilator aclieves the set airway pressure in pressure-targeted modes, such as pressure control ventilation (PCV). With varying PRT, in principle, the peak inspiratory flow rate of the ventilator also varies. And if PRT is set to a shorter duration, the effective duration of target pressure level would be prolonged, which in turn would increase inspiratory tidal volume(Vti) and mean airway pressure (Pmean). We also postulated that the increase in Vti with shortening of PRT may relate inversely to the patients' basal airway resistance. Methods : In 13 paralyzed patients on PCV (pressure control 18$\pm$9.5 cm $H_2O$ $FIO_2\;0.6\pm0.3$, PEEP 5$\pm$3 cm $H_2O$, f 20/min, I : E1 : 2) with Servo 300 (Siemens-Elema, Solna, Sweden) from various causes of respiratory failure, PRT of 10 %, 5 % and 0 % were randomly applied. At 30 min of each PRT trial, peak inspiratory flow (PIF, L/sec), Vti (ml), Pmean (cm $H_2O$) and ABGA were determined. Results : At PRT 10%, 5%, and 0%, PIF were 0.69$\pm$0.13, 0.77$\pm$0.19, 0.83$\pm$0.22, respectively (p<0.001). Vti were 425$\pm$94, 439$\pm$101, 456$\pm$106, respectively (p<0.001), and Pmean were 11.2$\pm$3.7, 12.0$\pm$3.7, 12.5$\pm$3.8, respectively (p<0.001). pH were 7.40$\pm$0.08, 7.40$\pm$0.92, 7.41$\pm$0.96, respectively (p=0.00) ; $PaCO_2$ (mm Hg) were 47.4$\pm$15.8, 47.2 $\pm$15.7, 44.6$\pm$16.2, respectively (p=0.004) ; $PAO_2-PaO_2$ (mm Hg) were 220$\pm$98, 224$\pm$95, 227$\pm$94, respectively (p=0.004) ; and $V_n/V_T$ as determined by ($PaCO_2-P_E-CO_2$)/$PaCO_2$ were 0.67$\pm$0.07, 0.67$\pm$0.08, 0.66$\pm$0.08, respectively (p=0.007). The correlation between airway resistance and change of Vti from PRT 10% to 0% were r= -0.243 (p=0.498). Conclusion : Shortening of pressure rise timee during PCV was associated with increased tidal volume, increased mean airway pressure and lower $PaCO_2$.

  • PDF

Application of MicroPACS Using the Open Source (Open Source를 이용한 MicroPACS의 구성과 활용)

  • You, Yeon-Wook;Kim, Yong-Keun;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Tae-Sung;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.51-56
    • /
    • 2009
  • Purpose: Recently, most hospitals are introducing the PACS system and use of the system continues to expand. But small-scaled PACS called MicroPACS has already been in use through open source programs. The aim of this study is to prove utility of operating a MicroPACS, as a substitute back-up device for conventional storage media like CDs and DVDs, in addition to the full-PACS already in use. This study contains the way of setting up a MicroPACS with open source programs and assessment of its storage capability, stability, compatibility and performance of operations such as "retrieve", "query". Materials and Methods: 1. To start with, we searched open source software to correspond with the following standards to establish MicroPACS, (1) It must be available in Windows Operating System. (2) It must be free ware. (3) It must be compatible with PET/CT scanner. (4) It must be easy to use. (5) It must not be limited of storage capacity. (6) It must have DICOM supporting. 2. (1) To evaluate availability of data storage, we compared the time spent to back up data in the open source software with the optical discs (CDs and DVD-RAMs), and we also compared the time needed to retrieve data with the system and with optical discs respectively. (2) To estimate work efficiency, we measured the time spent to find data in CDs, DVD-RAMs and MicroPACS. 7 technologists participated in this study. 3. In order to evaluate stability of the software, we examined whether there is a data loss during the system is maintained for a year. Comparison object; How many errors occurred in randomly selected data of 500 CDs. Result: 1. We chose the Conquest DICOM Server among 11 open source software used MySQL as a database management system. 2. (1) Comparison of back up and retrieval time (min) showed the result of the following: DVD-RAM (5.13,2.26)/Conquest DICOM Server (1.49,1.19) by GE DSTE (p<0.001), CD (6.12,3.61)/Conquest (0.82,2.23) by GE DLS (p<0.001), CD (5.88,3.25)/Conquest (1.05,2.06) by SIEMENS. (2) The wasted time (sec) to find some data is as follows: CD ($156{\pm}46$), DVD-RAM ($115{\pm}21$) and Conquest DICOM Server ($13{\pm}6$). 3. There was no data loss (0%) for a year and it was stored 12741 PET/CT studies in 1.81 TB memory. In case of CDs, On the other hand, 14 errors among 500 CDs (2.8%) is generated. Conclusions: We found that MicroPACS could be set up with the open source software and its performance was excellent. The system built with open source proved more efficient and more robust than back-up process using CDs or DVD-RAMs. We believe that the operation of the MicroPACS would be effective data storage device as long as its operators develop and systematize it.

  • PDF