Electromagnetic Wave Shielding Effectiveness Measurement Method of EMP Protection Facility (EMP 방호시설의 전자파 차폐효과 측정 방법)

  • Seo, Manjung;Chi, Seongwon;Kim, Youngjin;Park, Woochul;Kang, Hojae;Huh, Changsu
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.5
    • /
    • pp.548-558
    • /
    • 2014
  • EMP(Electromagnetic Pulse) protection facility was evaluated according to standard of shielding effectiveness. To comply with the standard, transmitting antenna was placed on outside of protection facility and receiving antenna was placed on inside of protection facility. However, measurement is impossible that place does not have enough space between protection facility and external concrete structure. In this paper, we performed a various of tests that put transmitting antenna inside the EMP protection facility in order to find out test method for measuring the shielding effectiveness of electromagnetic wave. Transmitting antenna was placed on inside of the EMP protection facility for measuring the shielding effectiveness to compare and analyze the impact of the position regarding to the transmitting and receiving antenna. As a result of test, in case that transmitting antenna was placed on inside of the EMP protection facility, it was found that test frequency range 10 kHz~1 GHz were occurred overall average difference of ${\pm}4$ dB level.

Design and Manufacturing of Multiscale Hybrid Composites for Electromagnetic Interference Shielding (전자파차폐용 멀티스케일 하이브리드 복합재의 설계 및 제조)

  • Ngouanom, Joel Renaud Gnidakouong;Kim, Myung-Soo;Park, Hyung-Wook;Park, Young-Bin;Jung, Young-Bok;Jeong, Ho-Soon
    • Composites Research
    • /
    • v.24 no.6
    • /
    • pp.25-30
    • /
    • 2011
  • This paper presents an experimental study on the enhancement of electromagnetic shielding (EMI) properties of glass fiber, carbon fiber, and glass-carbon fiber composites by adding layers of multi-walled carbon nanotubes (MWCNTs). In the case of glass-fiber composites, spraying 0.1~0.2 g of MWCNT over a fiber area of $200mm{\times}200mm$ (1.8~3.6 ${\mu}m$ in thickness) resulted in significant improvement in EMI shielding effectiveness (SE). Also, when applying multiple MWCNT layers, it was more effective to place the layers concentrated near the center of the composite rather than spreading them out. On the contrary, inherently conductive carbon fiber and glass-carbon fiber composites did not show appreciable improvement with the addition of MWCNT layers. In order to maximize the effectiveness of carbon nanomaterials as EMI shielding fillers, it is imperative to understand the effect of these materials on various EMI shielding mechanisms and their interactions.

A Study of Shielding Property of Magnetic Field for the Film Impregnated with Soft Magnetic Powder (연자성 합금분말을 함침시킨 필름의 자계 차폐 특성 연구)

  • Park, Jong-Hyun;Ra, Keuk-Hwan;Kang, Eun-Kyun;Kim, Jin-Woo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.1
    • /
    • pp.211-218
    • /
    • 2014
  • In this paper the magnetic field properties of the soft magnetic alloys (Fe-Si-Cr and Fe-Ni-Cr) are studied in advance for the development of electro-magnetic shielding films, which could be used in the IT Devices (NFC, mobile phone, computer, etc.).As a result each of the selected soft magnetic alloy melts of the corresponding compositions is water-dispersed into the disk-shaped grains, which are soaked in polymer resin, and of which two types of thin film of thickness 0.1mm and 1mm are made by passing through the heating calendar roller. And the magnetic permeability and the shielding effectiveness of the polymer films containing the soft magnetic alloy grains are measured over the whole frequency bands from the low frequency to 10GHz. Before the experiments of the soft magnetic alloy, a special equation is proposed to estimate the permeability of the alloy, and the equation is verified with the pre-published data by MATLAB, and from which the most optimal compositions can be decided. And the SE(Shielding Effectiveness) of the polymer films containing the soft magnetic alloy grains is simulated by the HFSS.

A Development of the Optimized Shielding Room Design Simulator for HEMP Protection (HEMP 방호용 차폐실 최적설계를 위한 시뮬레이터 개발)

  • Min, Gyung-Chan;Kim, Dong-Il
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.4
    • /
    • pp.121-126
    • /
    • 2010
  • Regarding HEMP has been studied as few thousand of paper by major nuclear bomb holding countries with USA for the self protection against nuclear bomb attract. Major HEMP protection facilities are consist of the shielding, filtering, grounding and high voltage protection circuits. Shielding room construction required a highest cost among the key protective facilities. Most of a theoretical formulas listed on the paper and related books has a little correlations in the certain frequency band between the theoretical formulas and field measuring results. For the reasons we proposed the advanced new theoretical formulas and developed the computer simulation S/W as enough as apply to the cost effective shielding room design for HEMP considering the various structural constants.

Electromagnetic Pulse (EMP) Shielding Effectiveness of Waveguide-Below-Cutoff (WBC) Arrays Installed in Generator Exhaust Chimney and its Effects on Gas Velocity (도파관 배열이 설치된 비상발전기 연도의 유속 예측 및 EMP 차폐평가)

  • Pang, Seung-Ki;Kim, Jae-Hun;Yook, Jong-Gwan;Kim, Yuna;Kim, Sangin;Kim, Suk-Bong
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • Characteristics of exhaust from chimney of electricity generator are analyzed based on CFD when Waveguide-Below-Cutoff (WBC) array is installed in order to achieve the certain level of electromagnetic pulse (EMP) shielding. The main purpose is prediction of average and maximum velocity of exhaust. The results reveal that: 1) When the specification of waveguide is given as 80-diameter, 400-length, and the gap of 20 mm, the shielding effectiveness (SE) is 140dB. The average and maximum velocity of exhaust in the chimney with WBC Array can be represented as exponential functions. 2) As the number of WBC increases, the velocity in the chimney dwindles. 3) Under the situation that WBC with 80 mm diameter is located at intervals of 20 mm, the average velocity can be approximated by $25.5344{\times}e^{(-0.0098{\times}N_{WBC})}$ with input velocity of 15 m/s. In addition, the determination coefficient is 0.915, which is sufficiently high.

Adhesion Improvement of Electroless Copper Plated Layer on PET Film - Effect of Pretreatment Conditions - (무전해 동도금 피막의 접착력 향상에 관한 연구 - PET 필름의 전처리 조건의 영향 -)

  • 오경화;김동준;김성훈
    • Polymer(Korea)
    • /
    • v.25 no.2
    • /
    • pp.302-310
    • /
    • 2001
  • Cu/PET film composites were prepared by electroless copper plating method. In order to improve adhesion between electroless Cu plated layer and polyester (PET) film, the effect of pretreatment conditions such as etching method and mixed catalyst composition, and accelerator was investigated. Compared to NaOH etching medium, PET film was more finely etched by HCl solution, resulting in an improvement in adhesion between Cu layer and PET film. However, there were no significant differences in electromagnetic interference shielding effectiveness as a function of etching medium. The surface morphology of Cu plated PET film revealed that Pd/Sn colloidal particles became more evenly distributed in the smaller size by increasing the molar ratio of PdCl$_2$ : SnCl$_2$ from 1 : 4 to 1 : 16. With increasing the molar ratio of mixed catalyst, the adhesion and the shielding effectiveness of Cu plated PET film were increased. Furthermore, HCl was turned out to be a better accelerator than NaOH in order to enhance the activity of the mixed PdCl$_2$/SnCl$_2$ catalyst, which facilitated the formation of more uniform copper deposit on the PET film.

  • PDF

Design of a Planar Log-Spiral Antenna for Testing Plane-Wave Shielding Effectiveness (평면파 차폐효과 시험용 평판형 로그 스파이럴 안테나 설계)

  • Chung, Yeon-Choon
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.762-767
    • /
    • 2019
  • The plane-wave shielding effectiveness is typically measured for horizontal and vertical polarizations using a linearly polarized antenna. However, this typical measurement method results in big evaluation fees due to very long measurement time as well as huge idle space for maintenance, these problems is more severe especially in large shielded enclosures such as EMP protection facilities to be built in indoor buildings and underground. This paper describes the design and fabrication process and results of a planar log-spiral antenna applicable to the evaluation of the electromagnetic shielding effectiveness of a large EMP protection facility. Since the proposed antenna has a circular polarization, there is no need to separately measure the horizontal and vertical polarizations. Therefore, the measurement time can be shortened by more than 1/2, and further, its small volume with a planar structure can reduce greatly idle space required for the maintenance.

Electromagnetic Wave Shielding Effect of Nano-powder Dispersed Epoxy Resin Composite (나노분말이 분산된 에폭시 섬유수지의 전자파차폐 효과)

  • Han, Jun-Young;Lee, Chul-Hee;Choi, Min-Gyu;Hong, Soon-Jik;Park, Joong-Hark;Lee, Dong-Jin
    • Journal of Powder Materials
    • /
    • v.22 no.4
    • /
    • pp.234-239
    • /
    • 2015
  • Electronic products are a major part of evolving industry and human life style; however most of them are known to emit electromagnetic waves that have severe health hazards. Therefore, different materials and fabrication techniques are understudy to control or limit transfer of such waves to human body. In this study, nanocomposite powder is dispersed into epoxy resin and shielding effects such as absorption, reflection, penetration and multiple reflections are investigated. In addition, nano size powder (Ni, $Fe_2O_3$, Fe-85Ni, C-Ni) is fabricated by pulsed wire evaporation method and dispersed manually into epoxy. Characterization techniques such as X-ray diffraction, Scanning electron microscopy and Transmission electron microscopy are used to investigate the phase analysis, size and shape as well as dispersion trend of a nano powder on epoxy matrix. Shielding effect is measured by standard test method to investigate the electromagnetic shielding effectiveness of planar materials, ASTM D4935. At lower frequency, sample consisting nano-powder of Fe-85%Wt Ni shows better electromagnetic shielding effect compared to only epoxy, only Ni, $Fe_2O_3$ and C-Ni samples.

Effect of Plasma Etching and $PdCl_2/SnCl_2$ Catalyzation on the Performance of Electroless Plated Copper Layer (플라즈마 에칭 및 $PdCl_2/SnCl_2$ 촉매조건이 무전해 동도금 피막의 성능에 미치는 영향)

  • 오경화;김동준;김성훈
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.7
    • /
    • pp.843-850
    • /
    • 2003
  • Cu/PET film composites were prepared by electroless copper plating method. In order to improve adhesion between electroless plated Cu layer and polyester (PET) film, the effect of pretreatment conditions such as etching method, mixed catalyst composition were investigated. Chemical etching and plasma treatment increased surface roughness in decreasing order of Ar>HCl>O$_2$>NH$_3$. However, adhesion of Cu layer on PET film increased in the following order: $O_2$<Ar<HCl<NH$_3$. It indicated that appropriate surface roughness and introduction of affinitive functional group with Pd were key factors of improving adhesion of Cu layer. PET film was more finely etched by HCI tolution, resulting in an improvement in adhesion between Cu layer and PET film. Plasma treatment with NH$_3$produced nitrogen atoms on PET film, which enhances chemisorption of Pd$^{2+}$ on PET film, resulting in improved adhesion and shielding effectiveness of Cu layer deposited on the Pd catalyzed surface. Surface morphology of Cu plated PET film revealed that Pd/Sn colloidal particles became more evenly distributed in the smaller size by increasing the molar ratio of PdCl$_2$; SnCl$_2$from 1 : 4 to 1 : 16. With increasing the molar ratio of mixed catalyst, adhesion and shielding effectiveness of Cu plated PET film were increased.d.