• Title/Summary/Keyword: SD-spectrum

Search Result 72, Processing Time 0.045 seconds

Analysis of sampling noise effect of Interferometer on FTIR Spectrometer (FTIR 분광용 간섭계의 샘플링 잡음 영향 분석)

  • Bae, Hyo-Wook;Park, Do-Hyun;Ra, Sung-Woong;Choi, Seung-Ki
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.4
    • /
    • pp.10-17
    • /
    • 2007
  • FTIR(Fourier Transform Infrared) spectrometry is a useful method to obtain infrared spectra of materials in gas phase by registering the interferogram of a target material using an interferometer, and then performing a Fourier transform on the interferogram to obtain the spectrum. In this paper, sampling noise effect on signal processing of the rapid scan interferometer was studied with relation to sampling the interferogram points at the improper location and empirically verified.

Complex Conjugate Resolved Retinal Imaging by One-micrometer Spectral Domain Optical Coherence Tomography Using an Electro-optical Phase Modulator

  • Fabritius, Tapio E.J.;Makita, Shuichi;Yamanari, Masahiro;Myllyla, Risto A.;Yasuno, Yoshiaki
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.111-117
    • /
    • 2011
  • Full-range spectral domain optical coherence tomography (SD-OCT) with a 1-${\mu}m$ band light source is shown here. The phase of the reference beam is continuously stepped while the probing beam scans the sample laterally (B-scan). The two dimensional spectral interferogram obtained is processed by a Fourier transform method to obtain a complex spectrum leading to a full-range OCT image. A detailed mathematical explanation of the complex conjugate resolving method utilized is provided. The system's measurement speed was 7.96 kHz, the measured axial resolution was $9.6{\mu}m$ in air and the maximum sensitivity 99.4 dB. To demonstrate the effect of mirror image elimination, In vivo human eye pathology was measured.

A new Structure of Bidirectional add/drop Multiplexer Using Fiber Bragg Gratings (광섬유 브래그 격자를 이용한 새로운 구조의 양방향 파장가감기)

  • Kim, Jeong-Ho;Lee, Byeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.5
    • /
    • pp.49-54
    • /
    • 2000
  • We propose a new structure of bidirectional add/drop multiplexer that is a key component to implement bidirectional ring network. The proposed bidirectional add/drop multiplexer is based on fiber Bragg gratings. In experiment, we demonstrate the operation of the proposed bidirectional add/drop multiplexer in optical spectrum domain.

  • PDF

GOCI-IIVisible Radiometric Calibration Using Solar Radiance Observations and Sensor Stability Analysis (GOCI-II 태양광 보정시스템을 활용한 가시 채널 복사 보정 개선 및 센서 안정성 분석)

  • Minsang Kim;Myung-Sook Park;Jae-Hyun Ahn;Gm-Sil Kang
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_2
    • /
    • pp.1541-1551
    • /
    • 2023
  • Radiometric calibration is a fundamental step in ocean color remote sensing since the step to derive solar radiance spectrum in visible to near-infrared wavelengths from the sensor-observed electromagnetic signals. Generally, satellite sensor suffers from degradation over the mission period, which results in biases/uncertainties in radiometric calibration and the final ocean products such as water-leaving radiance, chlorophyll-a concentration, and colored dissolved organic matter. Therefore, the importance of radiometric calibration for the continuity of ocean color satellites has been emphasized internationally. This study introduces an approach to improve the radiometric calibration algorithm for the visible bands of the Geostationary Ocean Color Imager-II (GOCI-II) satellite with a focus on stability. Solar Diffuser (SD) measurements were employed as an on-orbit radiometric calibration reference, to obtain the continuous monitoring of absolute gain values. Time series analysis of GOCI-II absolute gains revealed seasonal variations depending on the azimuth angle, as well as long-term trends by possible sensor degradation effects. To resolve the complexities in gain variability, an azimuth angle correction model was developed to eliminate seasonal periodicity, and a sensor degradation correction model was applied to estimate nonlinear trends in the absolute gain parameters. The results demonstrate the effects of the azimuth angle correction and sensor degradation correction model on the spectrum of Top of Atmosphere (TOA) radiance, confirming the capability for improving the long-term stability of GOCI-II data.

Assessment of Response Spectrum by Dynamic Centrifuge Test for the Pile Foundation into the Sand (동적 원심모형실험에 의한 사질토에 근입된 말뚝지지 기초의 응답 스펙트럼 분석)

  • Park, Yong-Boo;Park, Jong-Bae;Kim, Sang-Yeon;Kim, Dong-Soo
    • Land and Housing Review
    • /
    • v.5 no.1
    • /
    • pp.35-40
    • /
    • 2014
  • Site coefficient and amplification factor of current domestic Seismic Design Code (KBC-2009) have no consideration for the domestic ground condition in which the base rock is normally placed within 30m form the surface. Accordingly, in this study dynamic centrifugal test and analysis for pile foundation into sand and upper structure were achieved. and the response spectrums of free surface and basement were compared with each other. Within the period 1 sec., the measured spectral acceleration of free surface and basement was bigger than the design spectral acceleration of SC and SD site. However the measured spectral acceleration of free surface and basement for the period over 1.5 sec. was smaller than the design spectral acceleration of SC site. There was no severe difference of spectral acceleration according to the upper structure, embedded depth of foundation and free surface conditions. Consequently, normal domestic apartment housing for the period range over 1.5sec. could be design more economically applying these test result.

Vital Signal Monitoring Simulation System by Various Visual Stimulus (다양한 시각자극에 따른 생체신호 모니터링 시뮬레이션 시스템)

  • Chung, Kyung-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • With the development of next IT convergence technology and the construction of infrastructure for personalized services, the importance of services based on user's sensibility status and vital signal is being spotlighted. It is the most crucial factor for the strategy of sensibility engineering to investigate student's vital signal according to the sensibility. In this paper, we proposed the vital signal monitoring simulation system by the various visual stimulus. The proposed method obtained the student's vital signal by the various visual stimulus. And the power spectrum analysis using the fast fourier transform is evaluated the activity level between the sympathetic and the parasympathetic. The analyzed result is monitoring the sensibility by displaying the heath signal light. To evaluate the sensibility between the high school's students and the university's students, we conducted SD profile and paired T-tests so as to verify usefulness. This evaluation found that the difference of sensibility activity by positive and negative stimulus was statistically meaningful. Ultimately, this paper suggests empirical application to verify the adequacy and the validity.

Investigation of the Performance of Spectral Domain Optical Doppler Tomography with High-speed Line Scanning CMOS Camera and Its Application to the Blood Flow Measurement in a Micro-tube

  • Park, Cheol Woo;Lee, Changho;Lim, SooHee;Ni, Aleksey;An, Jin Hyo;Lee, Ho;Bae, Jae Sung;Kim, Jeehyun
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.174-180
    • /
    • 2012
  • In this study, the feasibility of spectral domain optical Doppler tomography for measuring blood flow characteristics in a micro-tube was demonstrated through several experiments. The use of an SD-ODT system in blood flow measurement can provide high resolution images (5 microns resolution). We prepared three capillary tubes to reveal the effect of different concentrations of hematocrit ratio (HR). One tube serves as the control. The two other tubes contained different concentrations of HR (5%, 25%). Three different capillary tube inlet flow velocities were tested in the present study. The Reynolds number (Re) which is based on the capillary tube inner diameter ranges from Re=6 to 48. We calculated a Doppler shift of the power spectrum of the temporal interference fringes with Kasai autocorrelation function to achieve the velocity profile of the flow. As a result, SD-ODT systems could not detect the cell depletion layer in the present study due to the limitation of spatial resolution. Nevertheless, these systems were proven to be capable of observing the RBCs of blood.

A Study on Human Autonomic Nervous System Activities by Far-Infrared Ray Hyperthermia (원적외선 온열이 인체 자율신경기능에 미치는 영향에 관한 연구)

  • Park Chan-Ouk;Jang Yun-Ho;Min Se-Dong;Kang Se-Gu;Lee Chung-Keun;Lee Myoungho
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.623-628
    • /
    • 2004
  • This paper describes autonomic nervous system activities caused by hyperthermia of far-infrared ray on human body. Designed protocol and analysis algorithm were evaluated by experiments on 20 subjects to analyze the characteristic of heart rate variability(HRV) signals which could be analyzed by FFT power spectrum and time-frequency analysis. Using Poincare' plot analysis, LF and HF were compared with SD1 and SD2. During the experiment, subject was exposed to hyperthermic effects of far-infrared radiation. We could confirm that far-infrared ray, which was known to improve the blood circulation, stress state and enhancing thermal effect into human body, had an effect on human nervous system. As the hyperthermic temperature of far-infrared ray increased, the activity of cardiovascular system to sustain the homeostasis was observed by means of investigating the increase of the sympathetic activity.

A Study on Estimating Earthquake Magnitudes Based on the Observed S-Wave Seismograms at the Near-Source Region (근거리 지진관측자료의 S파를 이용한 지진규모 평가 연구)

  • Yun, Kwan-Hee;Choi, Shin-Kyu;Lee, Kang-Ryel
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.121-128
    • /
    • 2024
  • There are growing concerns that the recently implemented Earthquake Early Warning service is overestimating the rapidly provided earthquake magnitudes (M). As a result, the predicted damages unnecessarily activate earthquake protection systems for critical facilities and lifeline infrastructures that are far away. This study is conducted to improve the estimation accuracy of M by incorporating the observed S-wave seismograms in the near source region after removing the site effects of the seismograms in real time by filtering in the time domain. The ensemble of horizontal S-wave spectra from at least five seismograms without site effects is calculated and normalized to a hypocentric target distance (21.54 km) by using the distance attenuation model of Q(f)=348f0.52 and a cross-over distance of 50 km. The natural logarithmic mean of the S-wave ensemble spectra is then fitted to Brune's source spectrum to obtain the best estimates for M and stress drop (SD) with the fitting weight of 1/standard deviation. The proposed methodology was tested on the 18 recent inland earthquakes in South Korea, and the condition of at least five records for the near-source region is sufficiently fulfilled at an epicentral distance of 30 km. The natural logarithmic standard deviation of the observed S-wave spectra of the ensemble was calculated to be 0.53 using records near the source for 1~10 Hz, compared to 0.42 using whole records. The result shows that the root-mean-square error of M and ln(SD) is approximately 0.17 and 0.6, respectively. This accuracy can provide a confidence interval of 0.4~2.3 of Peak Ground Acceleration values in the distant range.

Facet Reflectivities as a Function of Waveguide width of Buried Channel Waveguides using the Field Profiles Obtained by the Variational Method (Variational 방법으로 구한 필드 분포를 이용한 도파로 폭에 따른 Buried Channel Waveguides의 단면 반사율)

  • Kim, Sang-Taek;Kim, Dong-Hoo;Kim, Boo-Gyoun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.11
    • /
    • pp.36-42
    • /
    • 2000
  • We calculate the facet reflectivity as a function of the waveguide width of buried channel waveguides using the angular spectrum method and the field profiles obtained by the effective index method, the variational method and the modified variational method, respectively and discuss the results. As the waveguide width increases, the facet reflectivity of buried channel waveguides approaches to that of slab waveguides. As the waveguide width decreases, the facet reflectivity of quasi-TE mode decreases from that of slab waveguides, while that of quasi-TE mode increases from that of slab waveguides. The variation of the facet reflectivity of quasi-TE mode as a function of waveguide width is much larger than that of quasi-TM mode. When the aspect ratio is one, the difference between the facet reflectivity of quasi-TE mode and that of quasi-TM mode using the variational method and the modified variational method is negligible, while the difference between the facet reflectivity of quasi-TE mode and that of quasi-TM mode using the effective index method is large. In the case of quasi-TE mode, the facet reflectivity using the angular spectrum method and the field profiles obtained by the modified variational method could be more accurate than that obtained by the effective method. In the case of quasi-TM mode, the facet reflectivities obtained by the various methods are almost the same.

  • PDF