• Title/Summary/Keyword: SCR turn on/off time

Search Result 8, Processing Time 0.02 seconds

ISC-STS Proposal for Reliability Improvement of Communication System's (통신용 전원공급 신뢰성 증진을 위한 ISC-STS 제안)

  • Jung, Hyun-Chul;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.383-390
    • /
    • 2008
  • The SCR in Static Transfer Switch (STS) is used for reliability improvement of important load's power supply in industry field. However an average of 2% fault in thyristor(SCR) occurs, so that the attached mechanical switch is paralleled with SCR's both end points and SCR operates only during the $12{\sim}208$[mS] before operation of the mechanical switch. Also, an ISC (Ideal State Conditioning Interlock Device) - STS system that two power supply paths may not be thrown at the same time is developed to remove the overlap section perfectly when a short or earth fault is generated in one system. This method has reduced the fault rate remarkably through the reduction of SCR's fatigue degree by using SCR in conversion operation corresponding to 0.89 times a year. Also, in case of fault generations, it does not affect to supply power to the load, therefore it contributes to the promotion of reliability in the power supply.

A Study on Gate Trigger Current of SCR (SCR 게이트 전류의 변화특성에 관한 연구)

  • Seong, Houng-Su;Won, Hak-Jai;Han, Seung-Mun;Ha, Jeong-Hoon;Park, Ho-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1333-1335
    • /
    • 2000
  • In order to turn on the SCR gate, trigger signal source have to provide appropriate gate current and voltage under the gate rating based on the characteristic of SCR, the nature of load and power. It will be essential design factors such as trigger source impedance, trigger signal occurring, signal time width and turn off conditions. Also minimum gate trigger current is changed with the deterioration of SCR. SCR, which is needed large gate trigger current absolutely, is very important for SCR characteristic test because it causes unstable output in the misfile or makes a trouble to pulse trigger circuits. This paper shows scheme to test the performance of SCR with the precision analyzing mechanism and the changing trend of minimum gate current under the trigger conditions.

  • PDF

Study of Changes of Characteristics of SCR in accordance with a rise in temperature (온도상승에 따른 SCR 특성 변화에 관한연구)

  • Lee Young-Soo;Lee Kan-Woon;Park Moon-Dong;Cha Jae-Man
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1199-1201
    • /
    • 2004
  • When The temperature of the joining of SCR rises major changes of characteristics are increase of leakage current, decrease of break-down voltage, and increase of turn off time. Because these changes promote the inferiority of SCR it(SCR) will get out of control and its life time will be shortened and finally it will be destroyed. In this paper, we will measure the changes of the characteristics in accordance with a rise in temperature. On the basis of the result we will find out the appropriate time to change SCR and we will use the result for the maintenance of SCR and increase of reliability of SCR.

  • PDF

A Study on the Reversible SCR Servo Amplifier (정역전이 가능한 SCR 서보증폭기에 관한 연구)

  • Ahn, B. W.;Park, S. K.
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.2
    • /
    • pp.190-198
    • /
    • 1995
  • Many industrial servo amplifiers employ power transister as output device. Thyristor converters are not adopted to drive servo motor, although thyristor is superior to power TR in power rating, noise immunity, price, and size. The reason is, thyristor has no ability of self turn - off. Here in this paper line commutation, in which thyristor is turned off naturally since cathode voltage is higher than anode as time goes by, is employed to turn on thyristor with a delicate sequence. We developed thyristor servo amplifier which does not cause any damage on thyristor because it is designed to prevent triggering the two SCRs in the same arm simultaneously. And it was made clearly how to trigger SCR without any power line shorting and also harmonic analysis is carried out with the aid of FFT analyzer and proved that it can be used even severe reactive load. The designed circuit operated as a good DC amplifier in conventinal servomotor and the results can be use as a position control system application.

  • PDF

A study on the improvement of communiation circuit for DC chopper (DC chopper용 전류회로 개선에 관한 연구)

  • 노창주;오진석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.57-68
    • /
    • 1989
  • This paper treats the analytical and experimental studies on the improvement of commutating circuit for the speed control of DC motor. A simple circuit composed of R, L and C elements is proposed here for switching off power SCR carrying the load current. The real important in this chopper circuit is to determine the reasonable values of commutating circuit constants. In this paper, the reasonable values of the commutating circuit constants are basically determined on a view point of commutating performances in the given circuit model and must satisfy the following conditions. The first, the peak commutating current should be larger than the anticipated maximum load current. The second, the circuit turn-off time (tc) must be longer than the SCR turn-off time (tq). The third, the resistor should be enough large to permit the current to be neglected in the analysis of the commutation circuit, as well as be enough small to permit to charge the capacity voltage (Ec) to the half the value of source voltage (E) before the next communication cycle is initiated. The last, the period of chopping signal must be the least possible multiple of the damping vibration period of commutating circuit. The improved chopper circuit used in the experiment under unloaded condition was composed to meet the reasonable conditions mentioned above, and a successful commuting performance was achieved without failure. Several types of microprocessor having a different value of CPU speed individually have been applied to the experiment under the loaded conditions. Also it shows that the faster the speed of CPU is, the more stable the commutation turns out.

  • PDF

A Study on DC Circuit Breaker using SCR Chung Hoo Park (SCR 에 의한 직류회로차단기의 과부하차단특성개선)

  • 박정후
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.14 no.2
    • /
    • pp.89-95
    • /
    • 1978
  • A SCR static breaker was studied on the Resistive and inductive load, then on the overload break circuit using operational Amplifier. In this paper, the principal circuit required for forced commutation was voltage commutation by the introduction of a parallel Capacitor. The results obtained are follows; 1. In thecondition that the tima constant of R-C circuit is larger than the turn off time of SCR, the breaker has low transient phenomena and no recovery vol age. 2. By using OP Amplifier on the load circuit, overcurrent trip point will be able to adjust to the wide range of over current. 3. In the over current qrcuit, the power loss was reduced remarkably.

  • PDF

Operation characteristics of SFCLs combined with a transformer in three-phase power system

  • Jung, B.I.;Choi, H.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.30-33
    • /
    • 2013
  • The studies of superconducting fault current limiter (SFCL) for reduction of the fault current are actively underway in the worldwide. In this paper, we analyzed the characteristics of a new type SFCL using the conventional transformer and superconducting elements combined mutually. The secondary and third windings of this SFCL were connected the load and the superconducting element, respectively. The electric power was provided to load connected to secondary windings of the transformer in normal state of power system. On the other hand, when the fault occurred in power system, the fault current was limited by closing the line of third winding of the transformer. At this time, the ripple phenomenon of the fault was minimized by opening the fault line in secondary winding of a transformer in power system. The sensing of the fault state was performed by the CT(current transformer) and then turn-on and turn-off switching behavior of the SFCL was performed by the SCR(silicon-controlled rectifier). As a result, the proposed SFCL limited the fault current within a half-cycle efficiently. We confirmed that the fault current limitation rate was changed according to the winding ratio of a transformer.

Analysis of Transient Characteristics of SFCL using the Three-Phase Transformer and Power Switch (삼상 변압기와 전력용 스위치를 이용한 초전도 한류기의 과도특성 해석)

  • Jung, Byung-Ik;Choi, Hyo-Sang;Park, Jung-Il;Cho, Geum-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1743-1747
    • /
    • 2012
  • The research of superconducting fault current limiter (SFCL) for reduction of the fault current is actively underway in the worldwide. In this paper, we analyzed the characteristics of a SFCL using the transformer and superconducting elements combined mutually in accordance with the fault types. The structure of this SFCL was composed of the secondary and third windings of a transformer connected to the load and the superconducting element, respectively. The provided electric power flew into the load connected to the secondary winding of the transformer in normal state. On the other hand, when the fault occurred in power system, the fault current was limited by closing the line of third winding of the transformer. At this time, the effect of the fault was minimized by opening the fault line in secondary winding of a transformer in power system. The sensing of the fault state was performed by the current transformer(CT) and then turn-on and turn-off switching behavior of the secondary line in the transformer was performed by the silicon-controlled rectifier(SCR). As a result, the proposed SFCL limited the fault current within one-cycle efficiently. Also, the degradation of the superconducting element in the normal state was avoided.