• Title/Summary/Keyword: SC Wall

Search Result 99, Processing Time 0.026 seconds

Effects of Dietary Yeast (Saccharomyces cerevisiae) Components on Growth Performance, Heal Morphology and Serum Cholesterol in Male Broiler Chickens (효모(Saccharomyces cerevisiae)의 급여가 육계의 생산성. 장내 융모 발달 및 혈청 콜레스테롤에 미치는 효과)

  • Lee B. D.;Zhang A. W.;Sung C. K.;Ahn G. H.;Lee K. W.
    • Korean Journal of Poultry Science
    • /
    • v.32 no.1
    • /
    • pp.49-54
    • /
    • 2005
  • An experiment was conducted to investigate whether dietary yeast (Saccharomyces cerevisiae, SC) and its' structural components, i.e., yeast cell-extract (YE) and yeast cell-wall (CW) could influence growth performance, ileal morphology and serum lipids of male broiler chickens. There were four dietary treatments, each consisting of 6 replicates (10 birds per replicate). Chickens were fed a corn-soybean meal base control diet and diets containing SC ($0.5\%$), YE ($0.25\%$) and CW ($0.25\%$), respectively for 5-wk-experimental period. Dietary SC, YE and CW versus the control diet did not affect growth performance of male broiler chickens. Ileal morphology as to villus height, crypt depth and villus:crypt ratio of birds fed on the control diet was not significant from those fed on diets rich in SC, YE and CW, respectively. Dietary SC significantly lowered (P<0.05) serum total cholesterol by on average $19.7\%$ as compared to the control group. In addition, chickens fed on diets with either YE or CW lowered serum cholesterol by on average 15.3 and $12.5\%$, respectively as compared to the control albeit that the former only reached statistical significance. In conclusion, our study observed the hypocholesterolemic effect of SC in male broiler chickens. Moreover, YE, i.e., an extract of intracellular components of SC contains active molecules that are responsible far lowering serum cholesterol concentrations, but their identification at the molecular level needs to be assessed.

Experimental Study on Bending and Shear Behavior of SC Structures under Out of Plane Load (면외하중을 받는 보형 SC구조 시험체의 휨 및 전단특성에 관한 실험적 연구-시험방법을 중심으로-)

  • Park, Dong-Su;Jeoung, Won-Seoup
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.65-68
    • /
    • 2008
  • This is an experimental study on the out of plane load behavior of SC (Steel Plate Concrete) wall module under bending and shear loading. 4 tests were conducted to verify structural performance according to rib reinforcement ratio, stud reinforcement ratio and shear reinforcement ratio. On the basis of test results, it is found that rib reinforcement ratio is a main factor of flexural strength of SC structures.

  • PDF

Compressive performance with variation of yield strength and width-thickness ratio for steel plate-concrete wall structures

  • Choi, Byong-Jeong;Kim, Won-Ki;Kim, Woo-Bum;Kang, Cheol-Kyu
    • Steel and Composite Structures
    • /
    • v.14 no.5
    • /
    • pp.473-491
    • /
    • 2013
  • The primary objectives of this paper are to describe the buckling patterns and to determine the squash load of steel plate-concrete (SC) walls. The major variables in this study were the width-thickness (B/t) ratio and yield strength of surface steel plates. Six SC walls were tested, and the results include the maximum strength, buckling pattern of steel plates, strength of headed studs, and behavior of headed studs. Based on the test results, the effects of the B/t ratio on the compressive strength are also discussed. The paper also presents recommended effective length coefficients and discusses the effects of varying the yield strength of the steel plate, and the effects of headed studs on the performance of SC structures based on the test results and analysis.

A Study on the Bond Strength of Wall-Slab Joint of Steel Plate-Concrete Structures (SC구조의 벽-바닥 접합부의 정착강도에 관한 연구)

  • Choi, Kyong-Min;Kim, Ki-Sung;Kim, Byoung-Kook;Kim, Won-Ki;Choi, Oan-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.321-324
    • /
    • 2006
  • An experimental study on the bond strength of wall-slab joint in SC(steel plate-concrete) structure was performed. Six-full scale specimens were tested. Specimens were constructed with key variables, such as, development length, location of the bar and quantity of the shear bar. The experimental results, show that as the development length and quantity of the shear bar increase, the bond strength increases. As the bars is located on the inside the stud bolt, the bond performance was highly increased compared to the bars located out of plane of the stud bolts.

  • PDF

Estimated Risk of Radiation Induced Contra Lateral Breast Cancer Following Chest Wall Irradiation by Conformal Wedge Field and Forward Intensity Modulated Radiotherapy Technique for Post-Mastectomy Breast Cancer Patients

  • Athiyaman, Hemalatha;M, Athiyaman;Chougule, Arun;Kumar, HS
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.12
    • /
    • pp.5107-5111
    • /
    • 2016
  • Background: Epidemiological studies have indicated an increasing incidence of radiation induced secondary cancer (SC) in breast cancer patients after radiotherapy (RT), most commonly in the contra-lateral breast (CLB). The present study was conducted to estimate the SC risk in the CLB following 3D conformal radiotherapy techniques (3DCRT) including wedge field and forward intensity modulated radiotherapy (fIMRT) based on the organ equivalent dose (OED). Material and Methods: RT plans treating the chest wall with conformal wedge field and fIMRT plans were created for 30 breast cancer patients. The risks of radiation induced cancer were estimated for the CLB using dose-response models: a linear model, a linear-plateau model and a bell-shaped model with full dose response accounting for fractionated RT on the basis of OED. Results: The plans were found to be ranked quite differently according to the choice of model; calculations based on a linear dose response model fIMRT predict statistically significant lower risk compared to the enhanced dynamic wedge (EDW) technique (p-0.0089) and a non-significant difference between fIMRT and physical wedge (PW) techniques (p-0.054). The widely used plateau dose response model based estimation showed significantly lower SC risk associated with fIMRT technique compared to both wedge field techniques (fIMRT vs EDW p-0.013, fIMRT vs PW p-0.04). The full dose response model showed a non-significant difference between all three techniques in the view of second CLB cancer. Finally the bell shaped model predicted interestingly that PW is associated with significantly higher risk compared to both fIMRT and EDW techniques (fIMRT vs PW p-0.0003, EDW vs PW p-0.0032). Conclusion: In conclusion, the SC risk estimations of the CLB revealed that there is a clear relation between risk associated with wedge field and fIMRT technique depending on the choice of model selected for risk comparison.

Comparison of Continuous Appositional Suture Patterns for Cystotomy Closure in Ex Vivo Swine Model

  • Sang-hun Park;Joo-Myoung Lee;Hyunjung Park;Jongtae Cheong
    • Journal of Veterinary Clinics
    • /
    • v.39 no.6
    • /
    • pp.353-359
    • /
    • 2022
  • Several suture patterns can be used for cystotomy closure, and a continuous suture pattern is the most commonly used. In this study, the fluid-tight ability and other suitabilities of continuous appositional sutures, such as the simple continuous suture pattern (SC), running suture pattern (RN), and Ford interlocking suture pattern (FI), were compared for cystotomy closure. Cystotomy closure was performed using each suture method in 10 cases of ex vivo swine bladders in each group. Suture time, leakage site, suture length, bursting pressure (BP), bursting volume (BV), and circular bursting wall tension (CBWT) were measured. Suture time and suture length were the shortest in RN and the longest in FI. Leakage occurred in two places: the incision line directly and the hole made by the suture. Leakage occurred through the incision line in 4 bladders of the RN group and 2 bladders of the FI group, but not in the SC group, and in the rest of the bladders, leakage occurred through the suture hole. The values of BP, BV, and CBWT increased in the order of FI, SC, and RN. Suture time and suture length can be considered as factors related to healing and side effects. In this study, leakage through the incision was found in a less appositional area; therefore, leakage through the hole could be considered an indicator of better apposition. Good apposition is one of the conditions required for ideal cystotomy closure. The bursting strength representing the fluid-tight ability can be expressed as the CBWT. RN is expected to be efficient and cause a small degree of foreign body reaction; however, it is expected to be less stable. FI has the greatest fluid-tightness ability, but it has been proposed that side effects due to foreign body reactions most frequently occur in FI. In conclusion, SC, which is expected to have a sufficient degree of fluid-tightness and appropriate recovery, is preferable to other continuous appositional suturing methods for cystotomy closure.

Evaluation of Flexural Performance of Reinforced Concrete Shear Walls According to Flexural Retrofit by Wall End Excavating (단부 파쇄형 휨 보강에 따른 철근콘크리트 전단벽 휨 성능 평가)

  • Cho, Ui-Jin;Kim, Su-Yong;Bae, Baek-Il;Choi, Chang-Sik
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.4
    • /
    • pp.123-133
    • /
    • 2020
  • The purpose of this study is to analyze the method of retrofitting flexural strength and the flexural performance of retrofitted shear walls. There are various ways to reinforce the flexural strength of reinforced concrete shear wall structural systems that have already been built, in the case of that, the external force is increased, and the internal force is insufficient. However, there are various problems, such as excessive flexural stiffness after reinforcement and increasing the thickness and length of the wall. We have developed a retrofit method to solve these problems. The wall end is excavated to place the required vertical rebars, and concrete is poured after placing rebars. This is the same concept as creating wall end boundary elements later on. We also studied the anchorage method of reinforcement and the interaction method between the retrofitting end and the existing wall. The flexural test results for the reinforced concrete shear wall using the studied retrofit method can be predicted according to the sectional analysis and FEM analysis, and there are differences in the plastic hinge length, crack propagation, stiffness degradation and energy dissipation due to the bending depending on the vertical rebar ratio of wall end.

Analysis and Design on the Flexural Behavior of Composite Basement Wall Through Nonlinear Sectional Analysis (비선형 단면해석을 통한 합성지하벽의 휨 거동 분석 및 설계)

  • Seo, Soo-yeon;Kim, Hyeon-woo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.2
    • /
    • pp.145-153
    • /
    • 2020
  • The purpose of this study is to investigate the effects of composition of underground structural wall and H-pile in soil cement. The results of previous experimental studies are re-analyzed and the nonlinear cross-sectional analyses of composite basement walls are performed to verify their nonlinear flexural behavior. Based on the study, it is explained how the gap deformation between H-Pile and RC wall should be considered in the design of flexure of composite underground walls. The nonlinear cross-sectional analysis shows that the load-displacement curves of composite basement wall specimens exhibiting flexural behavior exist between the results of the analysis of the complete and non-composite cases. When predicting the behavior of the composite basement wall by nonlinear cross-sectional analysis, the flexural behavior of the composite basement wall could be suitably predicted by considering the reduction of the composite ratio due to tensile stress acting on shear connectors.

An Experimental Study on the Behavior of Steel Plate-Concrete Wall with Vertical Ribs (수직 보강된 SC 벽체의 거동에 대한 실험적 연구)

  • Lee, Seung Joon;Choi, Byong Jeong;Kim, Tae Kyoung
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.3
    • /
    • pp.277-287
    • /
    • 2009
  • The objective of this study was to experimentally investigate the structural behavior of steel plate concrete walls with vertical ribs (SSC walls), to compare the experimental results with the currently applied evaluation equations, and to obtain information that would be useful in the development of design equations for SSC walls. SSC test specimens that were subjected to in plane shear forces and bending moments were fabricated and tested. The experimental results show that the effect of vertical ribs on the structural behavior of SSC walls may be neglected, and that the confinement effect of concrete on the steel plates on both sides of the walls was negligible. The comparison of the experimental results with the evaluation equations showed that the structural behavior of SSC walls under shear control is close to that of the evaluation equations, but that the behavior of SSC walls under larger bending moments is not very close to that of the evaluation equations. The current evaluation equations for USC walls may be applied to the design of SSC walls because the structural walls of nuclear power plants are not subjected to large in plane bending moments.