Dosimetric comparison of volumetric modulated arc therapy with robotic stereotactic radiation therapy in hepatocellular carcinoma

  • Paik, Eun Kyung;Kim, Mi-Sook;Choi, Chul Won;Jang, Won Il;Lee, Sung Hyun;Choi, Sang Hyoun;Kim, Kum Bae;Lee, Dong Han
    • Radiation Oncology Journal
    • /
    • 제33권3호
    • /
    • pp.233-241
    • /
    • 2015
  • Purpose: To compare volumetric modulated arc therapy of RapidArc with robotic stereotactic body radiation therapy (SBRT) of CyberKnife in the planning and delivery of SBRT for hepatocellular carcinoma (HCC) treatment by analyzing dosimetric parameters. Materials and Methods: Two radiation treatment plans were generated for 29 HCC patients, one using Eclipse for the RapidArc plan and the other using Multiplan for the CyberKnife plan. The prescription dose was 60 Gy in 3 fractions. The dosimetric parameters of planning target volume (PTV) coverage and normal tissue sparing in the RapidArc and the CyberKnife plans were analyzed. Results: The conformity index was $1.05{\pm}0.02$ for the CyberKnife plan, and $1.13{\pm}0.10$ for the RapidArc plan. The homogeneity index was $1.23{\pm}0.01$ for the CyberKnife plan, and $1.10{\pm}0.03$ for the RapidArc plan. For the normal liver, there were significant differences between the two plans in the low-dose regions of $V_1$ and $V_3$. The normalized volumes of $V_{60}$ for the normal liver in the RapidArc plan were drastically increased when the mean dose of the PTVs in RapidArc plan is equivalent to the mean dose of the PTVs in the CyberKnife plan. Conclusion: CyberKnife plans show greater dose conformity, especially in small-sized tumors, while RapidArc plans show good dosimetric distribution of low dose sparing in the normal liver and body.

폐암의 정위적체부방사선치료에서 육안적종양체적 변화에 따른 적응방사선치료의 효용성 및 가능성 연구 (Feasibility and Efficacy of Adaptive Intensity Modulated Radiotherapy Planning according to Tumor Volume Change in Early Stage Non-small Cell Lung Cancer with Stereotactic Body Radiotherapy)

  • 박재원;강민규;예지원
    • 한국의학물리학회지:의학물리
    • /
    • 제26권2호
    • /
    • pp.79-86
    • /
    • 2015
  • 이 연구는 조기 폐암의 정위방사선치료에서 육안적종양체적(Gross tumor volume, GTV) 변화에 따른 적응방사선치료(ART)의 효과 및 가능성을 보기 위해 시행되었다. 영남대학교 의료원에서 정위방사선치료를 시행한 22개의 종양을 대상으로 연구를 진행하였다. 정위방사선치료는 2주에 걸쳐 48 혹은 60 Gy를 4회에 나누어 조사하는 방법으로 시행되었다. 종양체적 변화를 측정하기 위해 매 콘빔시티마다 육안적종양체적에 대한 윤곽선 그리기를 시행하였다. 그 다음 첫 번째 콘빔시티에 기준 치료계획으로 사용할 세기조절방사선치료 계획을 시행하였다. 적응방사선치료 계획을 하기 위해, 2, 3, 4번째 콘빔시티에 기준 치료계획과 동일한 빔 각도와 제약을 적용하여 각각 재 최적화 과정을 진행하였다. 이후 적응방사선치료 계획은 기준치료계획을 각각의 콘빔시티에 복사하여 생성한 비적응방사선치료 계획과 비교되었다. 평균 육안적종양체적은 10.7 cc였다. 평균 종양체적 변화는 두 번째, 세 번째, 네 번째 콘빔시티에서 각각 -1.5%, 7.3%, 25.1%였으며 세 번째 이후 변화는 통계적으로 유의하였다(p<0.05). 하지만 두 번째 콘빔시티에서는 9개의 종양 체적이 증가하였다. 적응방사선치료 계획을 시행하였을 때, 폐에서 $V_{20\;Gy}$, $D_{1500\;cc}$, $D_{1000\;cc}$가 유의하게 감소하였으며, 흉벽에 대한 $V_{30\;Gy}$$V_{32\;Gy}$ 역시 유의하게 감소하였다(p<0.05). 두 번째 콘빔시티의 종양체적이 증가한 환자들에서, 기준치료 계획에 비해 적응치료방사선치료 계획을 시행하지 않았을 때, 계획용 표적체적에 대한 선량 범위 변수 중 $D_{min}$은 8.3% 감소한 반면 (p=0.021), 적응방사선치료계획을 시행한 경우에는 차이가 없었다. 이러한 결과를 보았을 때, 적응방사선치료 계획을 함으로서 표적 선량 커버는 개선시키면서 손상위험장기에 대한 선량을 감소시킬 수 있을 것이다. 그러므로, 콘빔시티를 이용한 적응방사선치료 방법은 조기 폐암의 정위방사선치료에서 고려되어야 하겠다.

간원개에 위치한 종양에 대한 Anisotropic Analyticalal Algorithm과 Pencil Beam Convolution 알고리즘에 따른 전달선량 비교 (Comparison of Dose Distributions Calculated by Anisotropic Analytical Algorithm and Pencil Beam Convolution Algorithm at Tumors Located in Liver Dome Site)

  • 박병도;정상훈;박성호;곽정원;김종훈;윤상민;안승도
    • 한국의학물리학회지:의학물리
    • /
    • 제23권2호
    • /
    • pp.106-113
    • /
    • 2012
  • 본 연구에서는 종양이 간원개에 위치한 환자들을 대상으로 Eclipse 치료계획시스템(treatment planning system V8.9 : TPS, Varian)에서 쓰이는 두 종류의 선량계산 알고리즘(pencil beam convolution : PBC, anisotropic Analytical algorithm : AAA)들을 적용하여 육안적종양체적(gross tumor volume : GTV), 내부표적체적(internal target volume : ITV), 계획용표적체적(planning target volume : PTV) 및 주요 관심장기에 전달되는 선량의 변화를 정량적으로 평가하고, 선량분포에 영향을 미칠 수 있는 인자들을 분석하고자 하였다. 본원에서 치료받은 간암환자 20명을 대상으로 하였고 그 중 10명의 환자들에 대해서는 정위적 방사선치료(stereotactic body radiation therapy : SBRT) 기술을 적용, 다른 10명의 환자들에 대해서는 3차원 입체조형 방사선치료(three-dimensional conformal radiation therapy : 3DCRT) 기술을 적용하여 치료하였다. 조사선량은 우선적으로 PBC 알고리즘을 적용하여 선량계산을 하였고 동일한 빔 정렬 및 콜리메이터(Collimator), Monitor Unit (MU) 그리고 Field 가중치를 적용시켜서 AAA 선량계산법으로 다시 계산 한 후, 두 알고리즘에 대한 처방선량 100%에 해당하는 체적(V100)의 lesion coverage factor (CVF) 들을 비교하였다. SBRT 기술을 이용한 환자들의 치료계획에서 전체 PTV에 대한 CVF의 경우, 두 선량계산 알고리즘사이 통계학적으로 유의한 상관관계(p=0.018)를 보였다. 또한, 3DCRT 기술을 이용한 환자들의 치료계획에서는 전체 PTV (p=0.006), 간원개에 위치한 PTV (p=0.013), 전체 ITV (p=0.024)에 대하여 각각 통계학적으로 유의한 상관관계를 보였다. 복부에 위치한 주요 관심장기에 대하여 SBRT 기술을 이용한 환자들의 치료계획에서 정상 간과 신장에 조사되는 최대선량에 대하여 통계학적으로 각각 유의한 상관관계(정상간: p=0.009, 신장: p=0.037)를 보였다. 본 연구에서 선택한 선량변화 예측인자들에 대하여 대응표본 T-검정(paired T-test)을 시행한 결과, 전체 PTV에 대한 간원개에만 위치하는 PTV의 비율($PTV_{dome}$/PTV)과 두 알고리즘에 의한 CVF 비율의 상관관계에 있어서 통계학적으로 유의미한 상관관계를 보였다(p<0.01). 또한, 종양의 크기에 대한 두 알고리즘의 CVF 비율에 있어서 통계학적으로 의미가 있는 상관관계를 보였다(SRS환자 p=0.017, 3DCRT환자 p=0.023). 본 연구에서는 15MV x-ray beam으로 선량을 계산할 때 PBC와 AAA간의 선량계산 차이를 분석하여 선택한 선량변화 예측인자 중 간원개에 위치한 종양의 크기와 계획용 표적체적에 대한 관계성을 알아내었다. 일반적으로 15MV x-ray beam에 의한 선량분포를 정확하게 알아내는 것은 AAA으로도 불충분하다는 것이 일반적인 사실로 받아들여지고 있어 이를 AAA와 PBC간의 차이로 그 정확성을 간접적으로 유추하여 실질적인 선량분포에 대한 치료계획단계에서의 선량분포의 차이의 경향성을 보고자 하였다.

폐암 환자의 정위적 체부 방사선 치료 시 IntraFraction CBCT를 이용한 치료 중 자세 오차 교정에 대한 고찰 (An investigation Of IntraFraction Motion Correction For Lung Stereotactic Body Radiation Therapy By Using IntraFraction Cone Beam Computed Tomography)

  • 송형석;조강철;박효국;윤종원;조정희
    • 대한방사선치료학회지
    • /
    • 제31권1호
    • /
    • pp.67-74
    • /
    • 2019
  • 목 적: 폐암 환자의 정위적 체부 방사선 치료를 시행하는 동안 발생할 수 있는 표적의 움직임을 치료 중 CBCT를 사용하여 표적의 위치 변화를 재보정함으로써 긴 치료 시간에 의해 발생하는 치료 중 자세 오차를 교정하는데 목적이 있다. 대상 및 방법: 본원에서 시행한 폐암 정위적 체부 방사선 치료 시 치료 계획상 치료 Arc가 2개로 구성된 환자 14명의 데이터를 후향적으로 분석하였다. 치료 중 CBCT를 사용하여 영상을 획득하여 발생한 치료 중 자세 변화(IntraFraction Motion; IFM)를 분석하고 발생한 오차만큼 Arccheck 팬텀에 역으로 오차를 만들어 선량 분석을 실시하였다. 결 과: 첫번째 치료 중 CBCT의 Translation(x, y, z) 방향의 평균, 표준편차 그리고 최대 오차 값은 x(LR) 축에서 $0.16{\pm}0.05cm$, 0.72 cm, y(SI) 축에서 $0.2{\pm}0.14cm$, 1.26 cm, z(AP) 축에서 $0.24{\pm}0.08cm$, 0.82 cm로 나타났다. Rotation(x, y, z) 방향은 x(pitch) 축에서 $0.84{\pm}0.23^{\circ}$, $2.8^{\circ}$, y(yaw) 축에서 $0.72{\pm}0.23^{\circ}$, $2.5^{\circ}$, z(roll) 축에서 $0.7{\pm}0.19^{\circ}$, $2^{\circ}$로 나타났다. 두번째 치료 중 CBCT의 Translation(x, y, z) 방향의 평균, 표준편차 그리고 최대 오차 값은 x(LR) 축에서 $0.1{\pm}0.04cm$, 0.37 cm, y(SI) 축에서 $0.14{\pm}0.17cm$, 2 cm, z(AP) 축에서 $0.12{\pm}0.04cm$, 0.5 cm로 나타났다. Rotation(x, y, z) 방향은 x(pitch) 축에서 $0.45{\pm}0.12^{\circ}$, $1.3^{\circ}$, y(yaw) 축에서 $0.37{\pm}0.1^{\circ}$, $1^{\circ}$, z(roll) 축에서 $0.35{\pm}0.1^{\circ}$, $1.2^{\circ}$로 나타났다. IFM 값만큼 오차를 적용한 선량 비교에서 점 선량 값은 평균 $5.2{\pm}4.2%$의 차이가 발생했으며 감마 값은 $82.64{\pm}10.51%$로 나타났다. 결 론: 정위적 방사선 치료를 시행하는 폐암 환자의 있어서 치료 시간이 길어짐에 따라 발생하는 치료 중 자세오차의 크기를 줄이기 위해 개별 Arc CBCT를 사용해 추가적 자세 오차 교정을 하는 것이 치료 정확성과 효율성을 높일 것으로 사료된다.

Contemporary treatment with radiosurgery for spine metastasis and spinal cord compression in 2015

  • Ryu, Samuel;Yoon, Hannah;Stessin, Alexander;Gutman, Fred;Rosiello, Arthur;Davis, Raphael
    • Radiation Oncology Journal
    • /
    • 제33권1호
    • /
    • pp.1-11
    • /
    • 2015
  • With the progress of image-guided localization, body immobilization system, and computerized delivery of intensity-modulated radiation delivery, it became possible to perform spine radiosurgery. The next question is how to translate the high technology treatment to the clinical application. Clinical trials have been performed to demonstrate the feasibility of spine radiosurgery and efficacy of the treatment in the setting of spine metastasis, leading to the randomized trials by a cooperative group. Radiosurgery has also demonstrated its efficacy to decompress the spinal cord compression in selected group of patients. The experience indicates that spine radiosurgery has a potential to change the clinical practice in the management of spine metastasis and spinal cord compression.

Flattening filter-free beam을 이용한 방사선 치료 기법의 특성 및 환자의 시간적.경제적 유용성 평가 (The evaluation of properties for radiation therapy techniques with flattening filter-free beam and usefulness of time and economy to a patient with the radiation therapy)

  • 구장현;원희수;홍주완;장남준;박진홍
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.363-368
    • /
    • 2014
  • 목 적 : Flattening filter-free (3F) beam과 flattening filter (2F) beam을 이용한 치료기법에 따른 특성 비교와 환자 측면의 시간적 경제적 유용성을 비교 평가하고자 한다. 대상 및 방법 : Alderson rando phantom의 전산화단층촬영 영상을 획득하여 가상의 전립선을 설정한 후 세기변조 방사선치료, 용적변조 회전방사선치료 그리고 체부정위적 방사선치료에 3F와 2F beam을 각각 적용하여 총 6개의 전산화치료계획을 수립하였다. 선량률은 3F beam을 이용한 치료기법에 1200 MU/min을 설정하였고, 2F beam의 경우 600 MU/min을 적용하였다. 3F와 2F beam을 이용한 치료기법의 특성 비교를 위하여 총 monitor unit (MU)값을 비교하였고 치료시간의 비교를 위하여 beam on time (BOT)과 gantry rotation time (GRT)을 측정하였으며, 3F와 2F beam에 의한 각 치료기법에서 발생되는 광중성자 측정을 위하여 Surveillance And Measurement (SAM) 940을 사용하였다. 또한, 환자의 총 내원기간과 자기부담금을 계산하였다. 결 과 : 총 MU값은 세기변조 방사선치료에서 3F beam을 이용하였을 때 2F beam을 이용한 경우보다 최대 34.0% 증가하였고 BOT, GRT 그리고 광중성자 측정값은 체부정위적 방사선치료에 3F beam을 적용하였을 때 2F beam보다 각각 최대 39.8, 38.6, 48.1% 감소하였다. 환자의 총 내원기간과 자기부담금은 3F와 2F beam의 이용에 따른 차이는 없었으며, 치료기법 중 체부정위적 방사선치료가 10일과 169,560원으로 가장 적게 나타났다. 결 론 : 본 연구 결과, 3F beam의 고 선량률을 이용한 치료기법은 2F beam과 비교하여 총 MU값은 증가하였으나 BOT, GRT 그리고 광중성자 측정값이 모두 감소하였다. 이처럼 3F beam의 고 선량률을 사용하는 치료기법은 intra-fraction setup error 및 2차 방사선 유발암 발생률을 줄이는 효과를 기대할 수 있으나, 동일한 치료기법 내에서 3F와 2F beam 사용에 따른 환자에게 특별한 시간적 경제적인 이점은 없었다.

국내 선형가속기의 포괄적인 품질관리체계에 대한 제언 (Suggestion for Comprehensive Quality Assurance of Medical Linear Accelerator in Korea)

  • 최상현;박동욱;김금배;김동욱;이재기;신동오
    • 한국의학물리학회지:의학물리
    • /
    • 제26권4호
    • /
    • pp.294-303
    • /
    • 2015
  • 미국의학물리학회는 포괄적인 방사선치료기기의 품질관리를 위한 작업그룹(Task Group: TG) 40 보고서를 1994년 발표한 이후로 세기조절방사선치료, 정위적방사선치료, 및 영상유도방사선치료 등의 고정밀 방사선치료를 포함한 선형가속기에 대한 품질관리를 권고하기 위해 2010년에 AAPM TG-142를 발간하였다. 그리고 최근 국내에서도 최신 치료기법에 대한 품질관리의 필요성에 따라 원자력안전위원회는 원자력안전위원회고시 제2015-005호 "의료분야의 방사선안전관리에 관한 기술기준"을 발표하였다. 원자력안전위원회고시에는 각 의료기관에서 품질관리전문인력을 두어 품질관리 조직 및 직무, 품질관리에 필요한 장비, 품질관리 방법/주기/관리오차 및 관리오차 초과 시 조치방법 등에 대한 내용이 포함된 품질관리절차서를 수립하고 품질관리를 수행하도록 규정되어 있다. 이에 따라 의료기관에서는 3차원 입체조형방사선치료, 세기조절방사선치료, 정위적방사선치료 등과 같은 방사선치료유형별(Non-IMRT, IMRT, SRS/SBRT)로 방사선치료기기에 맞는 품질관리 항목, 주기 및 관리오차를 설정하고, 적절한 품질관리 장비 등을 사용하여 기관의 실정에 맞게 품질관리를 수행하여야 한다. 그러나 국내에는 선형가속기의 체계적인 품질관리를 구축할 수 있는 지침서나 학회 보고서 등이 미비하여 현재 각 의료기관별로 각기 다른 품질관리의 항목, 주기 및 관리오차를 설정하여 품질관리를 수행하고 있는 실정이다. 그러므로 본 논문에서는 방사선치료의 안전성 및 정확성을 확보하기 위해 원자력안전위원회 고시 및 TG-142에 기반한 국내 실정에 적합한 선형가속기에 대한 품질관리체계 구축 방안 등을 제안하였다. 제안된 선형가속기에 대한 품질관리 체계는 다른 고정밀 방사선치료기기 등의 품질관리 체계 구축에도 도움이 될 것으로 사료된다.

International Spine Radiosurgery Consortium Consensus Guidelines에 따른 Spine Stereotactic Radiosurgery에서 IMRT와 VMAT의 비교연구 (Comparison of IMRT and VMAT Techniques in Spine Stereotactic Radiosurgery with International Spine Radiosurgery Consortium Consensus Guidelines)

  • 오세안;강민규;김성규;예지원
    • 한국의학물리학회지:의학물리
    • /
    • 제24권3호
    • /
    • pp.145-153
    • /
    • 2013
  • 정위적 체부 방사선치료(Stereotactic Body Radiation Therapy, SBRT)는 척추 전이암을 치료하는데 있어서 점점 증가하고 있다. 표적 종양의 급격한 선량 변화와 등선량 분포를 얻기 위해서, 세기조절방사선치료(Intensity-modulated radiation therapy, IMRT)와 체적변조회전치료(Volumetric-modulated arc therapy, VMAT)는 척추 방사선수술에 있어서 필수적인 치료기법이다. 이 연구의 목적은 표적 종양을 위한 International Spine Radiosurgery (ISRC) Consortium의 consensus guideline으로 그려진 표적에 있어서 IMRT와 VMAT의 치료기법을 질적으로 비교하고자 한다. 경부, 흉부, 요추 부위에 종양치료를 받은 3명의 환자를 선택 하였다. 표적 종양은 ISRC의 consensus guideline을 바탕으로 정의 하였다. $T_B$는 vertebral body만 포함하였고, $T_{BPT}$는 vertebral body, pedicle, transverse process를 포함하였다. 그리고 $T_{ST}$는 spinous process와 transverse process를 포함하여 그렸다. Maximum spinal cord선량은 $T_B$, $T_{BPT}$, $T_{ST}$에서 각각 12.46 Gy, 12.17 Gy, 11.36 Gy였고, IMRT, RA1, RA2에서 각각 11.81 Gy, 12.19 Gy, 11.99 Gy였다. 평균 감소(90%~50%) 선량 거리 (mm)는 $T_B$, $T_{BPT}$, $T_{ST}$에서 각각 3.5 mm, 3.3 mm, 3.9 mm였고, IMRT, RA1, RA2에서 각각 3.7 mm, 3.7 mm, 3.3 mm였다. 가장 복잡한 $T_{BPT}$의 경우에서 IMRT, RA1, RA2의 conformity index는 각각 0.621, 0.761, 0.817 이었고, rDHI는 0.755, 0.796, 0.824 였다. IMRT와 VMAT 모두 척추 정위적 방사선수술에서 표적 종양에 급격한 선량 변화와 등선량 분포를 전달하였다. 그러나 표적 종양이 vertebral body, pedicle, transverse process를 포함한다면, IMRT 치료기법은 VMAT 치료기법과 비교해서 conformity index 측면에서 불충분하였다. 그럼에도 불구하고, IMRT 치료기법은 RA1, RA2와 비교해서 대부분의 영역에서 maximum spinal cord 선량을 줄이는데 더 효과적이었다.

호흡 동조 췌장 암 용적 세기조절 회전 치료 시 Inter-fraction Intra-fraction 분석 (Analysis of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in Pancreas Ca)

  • 조영필;서동린;홍택균;강태영;백금문;홍동기;윤인하;김진산
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.247-256
    • /
    • 2014
  • 목 적 : 췌장 환자 방사선 치료 중 기점(Fiducial) 대상 내부 및 외부 종양 움직임의 오차를 정량화 하고자 한다. 또한 cone beam computed tomography (CBCT) 를 기반으로 호흡 시 췌장의 움직임 분석하고자 한다. 대상 및 방법 : 용적 세기변조 회전조사 (V-MAT)를 적용, 정위적 방사선 치료를 국소 진행성 췌장암 환자 11명을 대상으로 하였다. CBCT 및 직교 투시이미지를 적용하여 기점(Fiducial Marker)의 Inter, intra-fraction 움직임 변화를 치료 전, 치료 진행 시 분석하였다. 결 과 : 치료 후 프로토콜을 오프라인 교정 프로토콜을 사용하여, CBCT 와 직교투시 간의 평균 오차(범위)는 0.0(-1.7~4.0), 0.3(-0.5~3.0) and 0.0(-4.1~6.6)mm 측방 (LR), 세로 (AP) 및 종 방향 (SI) 이였다. 무작위 Inter-fraction Setup 오차 결과는 -0.1, -2.3 and -1.1 mm: 95% Fiducial포함 마진은 각 9.9, 7.8, 12.5mm로 수식되었다. 결 론 : 위 분석으로 뼈 일치 정렬 후 잔류 불확실성이 있으며, SI 방향에 큰 임의의 움직임은 적합한 여백이 필요하다. 주변 내부 장기를 보호, 내부 장기 문제점을 최소화, 호흡편차를 고려, 치료 시 정기적으로 측정하여야 한다.

초기 폐암의 정위방사선치료후 반응평가 분석 (Response Evaluation after Stereotactic Ablative Radiotherapy for Lung Cancer)

  • 최지훈
    • 한국의학물리학회지:의학물리
    • /
    • 제26권4호
    • /
    • pp.229-233
    • /
    • 2015
  • 정위 방사선치료를 받은 폐암환자에서 결과를 후향적으로 분석하고자 하였다. 연속된 흉부 컴퓨터단층촬영(CT)의 종양의 크기변화 분석을 통해 치료 반응 평가를 조사하였다. 11명의 초기 비소세포폐암환자를 대상으로 정위 방사선치료 선량의 중앙값은 6,000 cGy이고 분할 조사 회수의 중앙값은 5회였다. 경과 관찰기간의 중앙값은 28개월로 치료후 종양의 크기 변화는 총 51회의 CT를 통해 분석하였고, 각 환자당 중앙값 3회의 CT 촬영이 시행되었다. 본 연구에서 치료의 총 반응률은 90.9%로 5명의 환자에서 완전관해와 5명에서 부분관해가 관찰되었다. 부분관해와 완전관해까지의 기간의 중앙 값은 각각 3개월과 5개월이었다. 경과관찰에서 3명의 환자가 병의 진행양상을 나타내었다. 본 연구에서 초기 폐암의 정위방사선치료후 CT 분석을 통해 반응 평가와 함께 치료 반응 시점을 확인할 수 있었다.