Measurement Data Comparison of Fast SAR Measurement System by Probe Arrays with Robot Scanning SAR Measurement System

  • Kim, Jun Hee;Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • 제14권4호
    • /
    • pp.336-341
    • /
    • 2014
  • Dosimetry of radiating electromagnetic wave from mobile devices to human body has been evaluated by measuring Specific Absorption Rate (SAR). Usual SAR measurement system scans the volume by robot arm to evaluate RF power absorption to human body from wireless devices. It is possible to fast estimate the volume SAR by software deleting robot moving time with the 2D surface SAR data acquired by arrayed probes. This paper shows the principle of fast SAR measurement and the measured data comparison between the fast SAR system and the robot scanning system. Data of the fast SAR is well corresponding with data of robot scanning SAR within ${\pm}3$ dB, and its dynamic range covers from 10 mW/kg to 30 W/kg with 4.8 mm probe diameter.

150 MHz 대역에서의 SAR 측정시스템의 유효성 연구 (A Study on the SAR Measurement System Validation at 150 MHz Band)

  • 최동근;김기회;최재훈
    • 한국전자파학회논문지
    • /
    • 제24권10호
    • /
    • pp.1008-1016
    • /
    • 2013
  • 한국전파법에서 휴대전화에만 적용되었던 전자파흡수율(SAR: Specific Absorption Rate) 측정 대상기기가 2012년 1월 이후 인체로부터 20 cm 이내에 위치하는 휴대용 송신 무선통신기기로 확대됨에 따라 150 MHz 대역의 무전기가 포함되어 이에 대한 SAR 적합성 평가를 위한 SAR 측정방법이 필요하다. 그러나 현재 SAR 측정방법에 대한 국제표준(IEC 62209-2)에서는 300 MHz 대역 이상의 주파수에 대해서 적용하고 있으며, 상용 SAR 측정시스템에서도 300 MHz 대역 이상의 주파수에 대해서만 측정이 가능하도록 되어 있는 실정이다. 본 논문에서는 150 MHz 대역의 SAR 측정 유효성 평가를 위한 기준 다이폴 안테나(복사체 길이: 760 mm, 반사 손실 : -25.48 dB) 및 평면형 모의인체의 크기($1,300 mm(L){\times}900 mm(W){\times}200 mm(H)$), 수치해석 SAR 목표값(1 g: 1.08 W/kg, 10 g: 0.77 W/kg)을 제시하였다. 제시된 기준 다이폴 안테나 및 평면형 모의인체를 제작하여 상용 SAR 측정시스템의 적합성 여부를 확인하였다. 측정된 1 g 및 10 g SAR 값은 각각 1.13 W/kg, 0.81 W/kg으로, IEC 국제 표준의 유효 범위인 ${\pm}10$ % 이내를 만족하였다. 본 연구를 통해 도출된 규격들은 국내 SAR 측정방법 및 IEC 국제 표준으로 반영될 수 있을 것으로 기대된다.

Probe 고정형 SAR 측정 시스템의 구현 (Implementation of SAR Measurement System with Stationary Probes)

  • 김정호;김윤명
    • 한국전자파학회논문지
    • /
    • 제17권2호
    • /
    • pp.221-227
    • /
    • 2006
  • 본 논문에서 제안한 probe 고정형 SAR 측정 시스템은 9개의 프로브를 측정 대상체에 꽃아 획득한 전기장 값들로부터 수초 이내에 $1cm^2$ SAR 값을 계산하고, 그 면적 SAR 값으로부터 1g SAR 값을 도출하는 기술로서, 이동통신 단말기의 개발 단계 및 생산 라인에 투입하여 신속하게 SAR 값을 측정하게 해준다. 국제 표준 문서에서 제시한 1g 기준 SAR 값과 측정된 SAR 값을 비교함으로써 제안된 측정 시스템의 타당성을 확인하였다.

Probe 고정형 SAR 측정 시스템 (Implementation of SAR Measurement System with Stationary Probes)

  • 김정호;김윤명
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.443-447
    • /
    • 2005
  • The SAR measurement system with stationary probes, presented in this paper, can calculate area SAR value based ell the measured 9 electric field data. By converting obtained area SAR to the volume SAR, the results can be acquired in a few seconds. The system can be very useful tool in the stages of handset development for mobile communication as well as in the handset production line because of its rapid SAR measurement. The system showed good linearity characteristics at 835 MHz of 10 $\sim$ 27 dBm input power range.

  • PDF

SAR와 현장관측에 의한 황해 어청도 주변 해역에서의 내부파 특성 (The Characteristics of Internal Waves Observed by SAR and in-situ Measurement Data Near Ocheong-Do in the Yellow Sea)

  • 김태림;최현용
    • 한국해양학회지:바다
    • /
    • 제8권2호
    • /
    • pp.132-137
    • /
    • 2003
  • 서해 중부 연안에서의 내부파 관측을 위하여 현장 관측과 인공위성의 SAR(Synthetic Aperture Radar)센서를 이용한 관측을 함께 수행하였다. 2002년 5월 28일부터 30일까지 어청도 서쪽 10 km해상에서 thermistor chain, RCM 및 ADCP 유속계를 계류하여 관측하였으며 주변해역에 대한 CTD 관측도 수행하였다. 또한 29일 오전 6시 53분 SAR 영상을 획득하였다. 현장관측 결과 계류 지점을 통과하는 여러 개의 내부파가 관측되었고 SAR 영상에서도 관측지점 주변에서 다수의 내부파 군의 공간적인 분포를 확인할 수 있었다. SAR영상에서 관측된 내부파의 공간적인 특성과 현장 관측에서 계산된 시간적인 특성에 K-dv(Korteweg and de Vries)방정식을 적용하며 서해 중부 연안에서 발생한 내부파의 특성을 분석하였다. 이러한 내부파는 물리적으로, 군사적으로, 그리고 해양생물학적으로 매우 중요한 현상이며 서해의 중요한 여름철 특성으로 고려되어야 할 것이다.

저수지 저수량 추정을 위한 위성 SAR 자료의 활용성 (Applicability of Satellite SAR Imagery for Estimating Reservoir Storage)

  • 장민원;이현정;김이현;홍석영
    • 한국농공학회논문집
    • /
    • 제53권6호
    • /
    • pp.7-16
    • /
    • 2011
  • This study discussed the applicability of satellite SAR (Synthetic Aperture Radar) imagery with regard to reservoir monitoring, and tried the extraction of reservoir storage from multi-temporal C-band RADARSAT-1 SAR backscattering images of Yedang and Goongpyeong agricultural reservoirs, acquired from May to October 2005. SAR technology has been advanced as a complementary and alternative approach to optical remote sensing and in-situ measurement. Water bodies in SAR imagery represent low brightness induced by low backscattering, and reservoir storage can be derived from the backscatter contrast with the level-area-volume relationship of each reservoir. The threshold segmentation over the routine preprocessing of SAR images such as speckle reduction and low-pass filtering concluded a significant correlation between the SAR-derived reservoir storage and the observation record in spite of the considerable disagreement. The result showed up critical limitations for adopting SAR data to reservoir monitoring as follows: the inappropriate specifications of SAR data, the unreliable rating curve of reservoir, the lack of climatic information such as wind and precipitation, the interruption of inside and neighboring land cover, and so on. Furthermore, better accuracy of SAR-based reservoir monitoring could be expected through different alternatives such as multi-sensor image fusion, water level measurement with altimeters or interferometry, etc.

휴대전화의 시험위치에 따른 SAR 분석 (SAR Analysis for Test Positions of Mobile Phone)

  • 최형도;이애경;조광윤;오학태
    • 한국전자파학회논문지
    • /
    • 제12권7호
    • /
    • pp.1199-1205
    • /
    • 2001
  • 최근, 휴대전화로부터 복사되는 전자파 노출에 대한 건강 위험성에 관한 국민적 관심이 높아지고 있고, 그에 따라 휴대전화가 전자파 인체보호기준의 적합성 여부를 평가하기 위한 전자파흡수율 측정 방법이 제안되어 왔다. 피시험기기인 휴대전화에 대한 국부 전자파흡수율은 전기장 프로브를 사용하여 모의조직으로 채워진 모의 인체 두부에서 전기장 분포를 측정함으로써 얻어진다. 전자파흡수율 측정에 요소가 되는 전기장 프로브, 모의인체의 형상과 크기, 모의조직의 전기정수 그리고 시험위치 등에 따라 측정값이 달라지므로 전자파흡수율 측정 기준을 설정하기 위해서는 이들 요소에 대한 연구가 요구된다. 본 논문에서는 휴대전화의 시험위치에 따른 전자 파흡수율 변화를 수치해석과 측정을 통해 분석하였으며, 통상 사용위치에서 최악의 조건을 조사하였다. 본 결과를 바탕으로 국내 전자파흡수율 측정 기준의 시험위치로서 접촉위치와 경사위치를 채택하였다.

  • PDF

Formulation of the Sucrose-Free Simulant Human Tissue for SAR Measurement at CDMA Mobile Band

  • Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • 제7권2호
    • /
    • pp.53-58
    • /
    • 2007
  • A general method to formulate the tissue-equivalent liquids for SAR measurement is proposed to make sucrose-free brain tissue applicable at 835 MHz as an example We suggest the tissue composition can be determined by measuring the dielectric constants and conductivities with the DI water and salt addition variation to the pre-manufactured auxiliary liquid of DGBE and TritonX-100 The manufactured liquid satisfies the specified electrical parameters of international standard at 835 MHz.

전자파 비흡수율(SAR) 측정용 전기장 프로브의 검파 전압 특성 (Characteristics of the Detection Voltages of an E-field Sensing Probe in SAR Measurement System)

  • 김윤명;이승배;김기회
    • 한국전자파학회논문지
    • /
    • 제16권2호
    • /
    • pp.217-221
    • /
    • 2005
  • 이동통신 기기로부터 복사되는 전자파가 인체에 흡수되는 에너지의 양은 모의 인체 내에서 전자파 비흡수율 [SAR(Specific Absorption Rate)]로 평가된다. RF 센싱 프로브의 Schottky 다이오드에 검출된 DC 전압은 높은 레벨에서 자승법칙(Square Law) 영역을 벗어나 선형성을 나타낸다. Square Law Region을 벗어난 직선 영역의 검파는 적절한 DCP(Diode Compression Point) 값으로 검 파된 전압을 보상하여야 한다. 적절한 보상에 의한 한 점에서의 SAR 값은 200 W/kg까지 측정할 수 있다.

시각 동기화 오차가 SAR 영상에 미치는 영향 분석 및 보상 (Analysis and Compensation of Time Synchronization Error on SAR Image)

  • 이수정;박우정;박찬국;송종화;배창식
    • 한국항공우주학회지
    • /
    • 제48권4호
    • /
    • pp.285-293
    • /
    • 2020
  • 본 논문에서는 Synthetic Aperture Radar (SAR, 합성개구레이다) 영상 품질을 향상시키기 위해 EGI/IMU (Embedded GPS/INS, Inertial Measurement Unit) 통합 항법 시스템에서 발생하는 시각 동기화 오차의 영향을 분석하고 이를 보상하기 위해 상태변수증강 기법을 적용한다. SAR 요동 측정 알고리즘으로 항체의 위치를 추적하기 위한 EGI와 추가적으로 안테나에 장착된 IMU를 결합하는 EGI/IMU 통합 항법 시스템이 많이 이용된다. 이와 같은 EGI/IMU 통합 항법 시스템에서 센서간의 시계가 동기화되지 않을 경우 시각 동기화 오차가 발생한다. 시각 동기화 오차가 항법 및 SAR 영상에 미치는 영향 분석을 통해 시각 동기화 오차가 SAR 영상 품질을 악화시키는 것을 확인하였다. 이를 보상하기 위해 상태변수증강 기법을 적용하고, 적용한 결과 SAR 영상 품질이 저하되지 않음을 확인하였다. 또한 기동에 따른 시각 동기화 오차 추정 성능과 가관측성을 분석하여 시각 동기화 오차를 효과적으로 추정하기 위해서는 회전 기동과 같은 시간에 따라 변화하는 기동이 필요함을 보였다. 따라서, SAR 영상에 미치는 시각 동기화 오차의 영향을 줄이기 위해서는 SAR 구간 전에 회전 기동 등 시간에 따라 변화하는 기동을 수행하여 시각 동기화 오차를 보상해 주어야 한다.