• Title/Summary/Keyword: SAR(Specific Absorption Rate)

Search Result 91, Processing Time 0.023 seconds

Input Power Determination of TEM Cell Due to SAR for Mobile Phone Wave Blood Exposure (휴대폰 전자파의 혈액 조사를 위한 SAR별 TEM 셀의 입력 전력 산출)

  • Youn Ji-Hun;Son Tae-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.8 s.99
    • /
    • pp.810-814
    • /
    • 2005
  • Input power for TEM cell apparatus due to SAR(Specific Absorption Rate) for culture blood cell is determined by the transmission and reflection measurement of blood into the TEM cell. Blood cell with skin cell are reference culture cells for the study of EM wave effect. Exposure RF power from exposure apparatus to culture cell should not only exact for SAR value, but also should be based on the theoretical theory. In this paper, insertion loss of 50 g blood was measured to know exposure power per gram for culture blood cell, and input power of TEM cell due to SAR 0.8, 1.6, 3, 4 mW/g using the measured data are delivered. This study is for applying to EM wave exposure apparatus to culture cell.

Design of Radiation Pattern Reconfigurable Antenna for Vital Signal Sensing Device Attached on Wristband and SAR Analysis on Human body (팔목 부착형 생체신호 측정기기에 사용가능한 방사패턴 재구성 안테나 설계 및 인체 SAR 영향 분석)

  • Lee, Chang Min;Jung, Chang Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.666-670
    • /
    • 2015
  • This paper presents radiation pattern reconfigurable antenna for Fitbit Flex wristband which detects vital signal. Also, the paper presents Specific Absorption Rate (SAR) from the loop-dipole radiation pattern reconfigurable antenna based on the position of human body. The proposed loop-dipole radiation pattern reconfigurable antenna produces two opposite side direction radiation pattern using two RF switches. The resonant frequency of the radiation pattern reconfigurable antenna is Bluetooth communication bandwidth (2.4 - 2.485 GHz) and the maximum gain of the proposed antenna is 1.96 dBi. The proposed antenna satisfied the standard SAR value of 1.6 W/kg in 1 g tissue of the human body when the Bluetooth communication input average power of 0.04 W is excited to five parts of human body (head, chest, stomach, back, wrist). The maximum SAR value of in this simulation is presented in the part of head.

The Statistical Technique for Dosimetric Meta-Analysis at in-vivo and in-vitro Papers about Bioeffects of RF Electromagnetic Field (RF 전자기장 생체 영향 연구 문헌에서 노출량 메타분석을 위한 통계적 기법)

  • Choi, Sung-Ho;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.12
    • /
    • pp.1311-1320
    • /
    • 2003
  • This paper proposed the estimating method of electromagnetic dosimetric reliability at in-vivo and in-vitro experiments. For more accurate consequences of these researches, we have tried to find out any correlations among output power, power density and specific absorption rate(SAR) with the results of in-vivo, in-vitro tests and SAR reports of cellular phone and PDA. In the case of in-vivo tests, the power density has close statistical correlations with SAR value and in the event of in-vitro tests, the output power has considerable statistical correlations with SAR containing duty factor. We analysed the coefficient of determination to estimate the dosimeoic uncertainty. If we use this method before evaluating techniques of measurement and analysis at both in-vivo and in-vitro experiments, we will conduct more accurate reliability test.

Electromagnetic Compatibility Study of a Medical Lead for MRI Systems (자기공명영상시스템에서의 의료용 리드선의 전자기적 호환 연구)

  • Yoo, Hyoungsuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.2019-2022
    • /
    • 2016
  • In the presence of an electrically conducting medical lead, radio frequency (RF) coils in magnetic resonance imaging (MRI) systems may concentrate the RF energy and cause tissue heating near the lead. A novel design for a medical lead to reduce this heating by introducing pins in the lead is presented. Peak 10 g specific absorption rate (SAR) in heart tissue, an indicator of heating, was calculated and compared for both conventional (Medtronic) lead design and our proposed design. Remcom XFdtd software was used to calculate the peak SAR distribution in a realistic model of the human body. The model contained a medical lead that was exposed to RF magnetic fields at 64 MHz (1.5 T), 128 MHz (3 T) and 300 MHz (7 T) using a model of an MR birdcage body coil. The proposed design of adding pins to the medical lead can significantly reduce the heating from different MRI systems.

Development and Validation of Reverberation Chamber Type Whole Body Exposure System fer Mobile Phone Frequency (이동전화 주파수에 대한 전자파 잔향실 형태의 전신 노출장치 개발 및 유효성 평가)

  • 정기범;고경배;도현정;백정기;정연춘;최재훈
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.3
    • /
    • pp.291-300
    • /
    • 2004
  • Due to the rapid growth of mobile communication services, many studies have been performed on the biological effects of EMF(Electromagnetic field) exposure. However, it is not easy to create the field uniformity in radio frequency. To overcome this difficulty, the electric field and SAR(Specific Absorption Rate) distribution is developed to measure the whole body exposure system. In this paper, we developed the whole body exposure system for in-vivo study utilizing reverberation chamber which has a high possibility of practical use by substituting previous the EMC chamber. The field uniformity in the test area of the designed reverberation chamber was satisfied by the simulation and measurement data. In animal study of the whole body exposure for a mouse, the results of FDTD simulation were compared with those of measurement to confirm SAR under the electromagnetic exposure. We analyze the electric field distribution in the interior of the reverberation chamber and treat these results in statistical manner. In the CDMA frequency band(PCS & Cellular band), an average value of the whole body SAR and local peak value for a experimental mouse were presented for various input power.

Realization of High Impedance Surface Characteristics Using a Periodically Transformed Artificial Magnetic Conductor Structure and Reduction Technique of Specific Absorption Rate

  • Lee, Seungwoo;Rhee, Seung-Yeop;Kim, Pan-Yeol;Kim, Nam
    • Journal of electromagnetic engineering and science
    • /
    • v.13 no.2
    • /
    • pp.113-119
    • /
    • 2013
  • We developed a transformed, symmetrical, mushroom-like surface without via holes in cells focused on a 2.4-GHz WLAN band. Each slot in the novel type structure plays a key role in modeling at the desired frequencies. The designed artificial magnetic conductor (AMC) has several advantages, including a small size, a wider bandwidth, a short reflecting distance to the antenna, and easy fabrication because there are no via holes. Overall dimensions of the AMC cell are 21 mm $(Width){\times}21mm$ $(Height){\times}2.6mm$ (Thickness), and the bandwidth is about three times wider (11.7%) compared to that of a conventional AMC (4.0%). For evaluating the performance of the proposed structure, a reflector, which periodically consists of the designed AMC cells, was developed. The antenna with the investigated AMC reflector not only works within a quarter of the wavelength because of the extremely high wave impedance generated by the AMC cells on the surface of the structure but also reduces the specific absorption rate (SAR). Electromagnetic field (EMF) exposure to a human phantom was analyzed by applying the designed reflector to the 2.4-GHz dipole antenna in a tablet PC. The calculated peak SAR averaged over 1 g was 0.125 W/kg when the input power was 1 W and the antenna was located at 20 cm from the human phantom. However, the SAR value was only 0.002 W/kg (i.e., 98.4% blocked) when the designed reflector was inserted in front of the antenna.

Automatic RF Input Power Level Control Methodology for SAR Measurement Validation

  • Kim, Ki-Hwea;Choi, Dong-Geun;Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.181-184
    • /
    • 2015
  • Evaluation of radiating radiofrequency fields from hand-held and body-mounted wireless communication devices to human bodies are conducted by measuring the specific absorption rate (SAR). The uncertainty of system validation and probe calibration in SAR measurement depend on the variation of RF power used for the validation and calibration. RF input power for system validation or probe calibration is controlled manually during the test process of the existing systems in the laboratories. Consequently, a long time is required to reach the stable power needed for testing that will cause less uncertainty. The standard uncertainty due to this power drift is typically 2.89%, which can be obtained by applying IEC 62209 in a normal operating condition. The principle of the Automatic Input Power Level Control System (AIPLC), which controls the equipment by a program that maintains a stable input power level, is suggested in this paper. The power drift is reduced to less than ${\pm}1.16dB$ by AIPLC, which reduces the standard uncertainty of power drift to 0.67%.

Method of SAR reduction for Wireless Transceiver (무선통신 단말기의 SAR 저감법)

  • Hwang, Jae-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.346-349
    • /
    • 2005
  • In this paper, we propose SAR(Specific absorption rate) reduction methods based on surface electric field distribution relation. Proposed the new method that is able to consider improvement of the SAR from the very beginning step of developing the wireless transceiver. Analysis of wireless handset with human body(head) using finite element method(FEM). Results of this method, SAR reduced about 50 %.

  • PDF

A Metamaterial-Based Handset Antenna with the SAR Reduction

  • Kahng, Sungtek;Kahng, Kyungseok;Yang, Inkyu;Park, Taejoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.622-627
    • /
    • 2014
  • A method to reduce the specific absorption rate(SAR) of the antenna for WiMAX mobile communication is proposed in this paper. The SAR reduction is achieved by miniaturizing the physical size of the antenna for the given resonance frequency by devising a metamaterial-composite right- and left-handed(CRLH) configuration-based radiator much smaller than the quarter-guided wavelength adopted a lot in the conventional planar inverted F antenna(PIFA) or modified monopole antenna. The proposed antenna is placed near the head-phantom and its SAR is evaluated by the full-wave simulations(SEMCAD X), where the metamaterial-inspired antenna is shown to have the lower value than a modified monopole as the reference in terms of the SAR.

Human Head Size and SAR Characteristics for Handset Exposure

  • Lee, Ae-Kyoung;Choi, Hyung-Do;Lee, Hyung-Soo;Pack, Jeong-Ki
    • ETRI Journal
    • /
    • v.24 no.2
    • /
    • pp.176-179
    • /
    • 2002
  • Using scaled models for an anatomical head model and a simple head model, we investigated the effects of head size on specific absorption rate characteristics for two mobile phones operating at 835 MHz and 1765 MHz. Our results showed that a larger head produced a higher localized SAR at 835 MHz. However, at 1765 MHz, the differences among the head models were insignificant since the superficial absorption was dominant over the effects of head shape and size. A larger head produced a lower whole-head averaged SAR at both frequencies.

  • PDF