• 제목/요약/키워드: SAP 2000

Search Result 177, Processing Time 0.027 seconds

Structural response relationship between scaled and prototype concrete load bearing systems using similarity requirements

  • Altunisik, Ahmet C.;Kalkan, Ebru;Basaga, Hasan B.
    • Computers and Concrete
    • /
    • v.21 no.4
    • /
    • pp.385-397
    • /
    • 2018
  • This study is focused on the investigation for similitude the requirements between prototype and scaled models to determine the structural behavior of concrete load bearing systems. The scaling concept has been utilized in many engineering branches, has been assisted to engineers and scientists for obtain the behavior of the prototype by using scaled model. The scaling can be done for two purposes, either scaling up or scaling down depending upon the application. Because, scaled down models are the experimentation on scaled models is cheaper than huge structures. These models also provide facilities for experimental work. Similarity relationships between systems are created either by field equations of the system or by dimensional analysis. Within this study, similarity relationships were obtained by both methods. The similarity relations obtained are applied to different load bearing systems and it is determined that the similarity relation is a general expression. In this study, as an example, column, frame, cantilever beam and simple beam are chosen and 1/2, 1/5 and 1/10 scales are applied. The results are compared with the analytical results which are obtained by creating of the finite element models with SAP2000 software of different scaled load bearing systems. The analysis results of all systems are examined and it is determined that the scale factors are constant depending on the scale types for different load bearing systems.

Seismic behavior of steel frames with lightweight-low strength industrialized infill walls

  • Zahrai, Seyed Mehdi;Khalili, Behnam Gholipour;Mousavi, Seyed Amin
    • Earthquakes and Structures
    • /
    • v.9 no.6
    • /
    • pp.1273-1290
    • /
    • 2015
  • JK wall is a shear wall made of lightweight EPS mortar and reinforced with a 3-D galvanized steel mesh, called JK panel, and truss-like stiffeners, called JK stiffeners. Earlier studies have shown that low strength lightweight concrete has the potential to be used in structural elements. In this study, seismic contribution of the JK infill walls surrounded by steel frames is numerically investigated. Adopting a hybrid numerical model, behavior envelop of the wall is derived from the general purpose finite element software, Abaqus. Obtained backbone would be implemented in the professional analytical software, SAP2000, in which through calibrated hysteretic parameters, cyclic behavior of the JK infill can be simulated. Through comparison with earlier experimental results, it turned out that the proposed hybrid modeling can simulate monotonic and cyclic behavior of JK walls with good accuracy. JK infills have a panel-type configuration which their dominant failure mode would be ductile in flexure. Finally technical and economical advantages of the proposed JK infills are assessed for two representative multistory buildings. It is revealed that JK infills can reduce maximum inter-story drifts as well as residual drifts at the expense of minor increase in the developed base shear.

A study on seismic behaviour of masonry mosques after restoration

  • Altunisik, Ahmet C.;Bayraktar, Alemdar;Genc, Ali F.
    • Earthquakes and Structures
    • /
    • v.10 no.6
    • /
    • pp.1331-1346
    • /
    • 2016
  • Historical masonry structures have an important value for cultures and it is essential for every society to strengthen them and confidently transfer to the future. For this reason, determination of the seismic earthquake response, which is the most affecting factor to cause the damage at these structures, gain more importance. In this paper, the seismic earthquake behaviour of Kaya Çelebi Mosque, which is located in Turkey and the restoration process has still continued after 2011 Van earthquake, is determined. Firstly the dynamic modal analysis and subsequently the seismic spectral analysis are performed using the finite element model of the mosque constructed with restoration drawings in SAP2000 program. Maximum displacements, tensile, compressive and shear stresses are obtained and presented with contours diagrams. Turkish Earthquake Code and its general technical specifications are considered to evaluate the structural responses. After the analyses, it is seen that the displacements and compressive/shear stresses within the code limits. However, tension stresses exceeded the maximum values at some local regions. For this mosque, this is in tolerance limits considering the whole structure. But, it can be said that the tension stresses is very important for this type of the structures, especially between the stone and mortar. So, some additional strengthening solutions considering the originality of historical structures may be applicable on maximum tensile regions.

Development of a Model for Animal Health Monitoring System V. Iso1ation Frequence Of Salmonella spp., Escherichia O157:H7 and Listeria monocytogenes from Dairy Cow with different herd size (동물(젖소)건강 Monitoring System 모델 개발 V. 유우의 사육규모에 따른 Salmonella spp., Escherichia coli O157:H7 및 Listeria monocytogenes의 분리 빈도)

  • 김용환;김종수;김곤섭;최민철;이은주
    • Journal of Veterinary Clinics
    • /
    • v.17 no.2
    • /
    • pp.316-320
    • /
    • 2000
  • The present study conducted to evaluate the isolation frequency of Salmonella sap., Escherichia O157:H7 and Listeria monocytogenes in fecal samples collected form 33 dairy cow feedlots in West Gyeong-nam province from tan. 179\ulcorner to Feb. 1999. Salmonella spp. were isolated from 8.7% of fecal samples and 57.5% of dairy cow feedlots participaiting in this study had at least one positive fecal 7ample. The isolation rates of Salmonella spp. in each herd size were 42.9% in ln less than 125 heads, 63.6% in 25% to 50 heads and 75% in more than 50 heads. Of the positive sample, the most common serogroup recovered was Bl(31.5%), followed by C1 and D(22.9%), C2(16.2%), A(4.2%) and E(2.1%), in order. However, E. coli O157:H7 and Listeria monocytogenes were net detected in the fecal samples collected from all feedlots.

  • PDF

Earthquake Response Reduction Simulation of a 3 Story Building Structure by Stockbridge Damper (스톡브릿지댐퍼를 사용한 지진시 구조물의 응답제어 시뮬레이션)

  • Chang, Seongkyu;Kim, Dookie;Raman, Mohammad Sabbir;Kim, Hyung Seong
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.295-300
    • /
    • 2016
  • In this study, Stockbridge damper was adopted to reduce the reponses of structures under earthquakes. A finite element analysis software, SAP2000, was used to simulate the structural response and the control device under dynamic loads. A 3 story frame model and the proposed control device, Stockbridge damper, were designed under laboratory conditions. In this research, a pendulum type tuned mass damper (PTMD) was also adopted in order to compare with the Stockbridge damper. Harmonic loads were applied to verity the control performance of both control devices in each mode. In results, it has been found that the Stockbirdge damper decreases significantly the responses of the structure more than the PTMD under the harmonic loadings. The El Centro and Northridge earthquakes were also applied in order to investigate the performance by both control devices. The responses of the building demonstrate that the Stockbridge damper reduces the response of the building structure during earthquakes more effectively than the PTMD.

Literatural Study on Prescription of the Skin Disease from the Viewpoint of the Onbyung(溫病) (온병적(溫病的) 관점(觀點)으로 본 피부질환(皮膚疾患) 처방(處方)에 관(關)한 고찰(考察))

  • Chang, Seung-Soon;Kang, Jung-Soo
    • Journal of Haehwa Medicine
    • /
    • v.9 no.1
    • /
    • pp.113-120
    • /
    • 2000
  • This study was carried out to investigate the relation between the Onbyung and the skin disease, and classify the medical treatment by some categories. The results were as follows ; 1. Onbyung reduces the Eun(陰) by the fever and the skin disease results from the deficiency of the Eun and blood. 2. We can grasp the depth of the disease and the damage of the Jung Gi(正氣) by the observation of the every condition on the skin disease. 3. Medical treatment 1. Hae Phyo Bub(解表法) Using the method of the perspiration, we take care of the preservation of the sap. 2. Cheong Gi Bub(淸氣法) of the using Gypsum and Tong Ha Bub(通下法) of the using Dae Whang(大黃). A. Cheong Gi Bub(淸氣法) When the Sa(邪) stay the Gi area(氣分), we use the radiational material or the Wha Sub(化濕) material with Gypsum. B. Tong Ha Bub(通下法) We reduce the evil fever by the Ha Bub(下法). 3. Cheong Yul Hae Dog Bub(淸熱解毒法) and Ja Eum Bub(滋陰法) 4. Wha Sub Bub(化濕法) This treatment reduce the fever by eliminating the urine or the sweat.

  • PDF

A consistent FEM-Vlasov model for hyperbolic cooling towers on layered soil under unsymmetrical wind load

  • Karakas, Ali I.;Ozgan, Korhan;Daloglu, Ayse T.
    • Wind and Structures
    • /
    • v.22 no.6
    • /
    • pp.617-633
    • /
    • 2016
  • In this paper, the analysis of hyperbolic cooling tower on elastic subsoil exposed to unsymmetrical wind loading is presented. Modified Vlasov foundation model is used to determine the soil parameters as a function of vertical deformation profile within subsoil. The iterative parameter updating procedure involves the use of Open Application Programming Interface (OAPI) feature of SAP2000 to provide two way data flow during execution. A computing tool coded in MATLAB employing OAPI is used to perform the analysis of hyperbolic cooling tower with supporting columns over a hollow annular raft founded on elastic subsoil. The analysis of such complex soil-structure system is investigated under self-weight and unsymmetrical wind load. The response of the cooling tower on elastic subsoil is compared with that of a tower that its supporting raft foundation is treated as fixed at the base. The results show that the effect of subsoil on the behavior of cooling tower is considerable at the top and bottom of the wall as well as supporting columns and raft foundation. The application of a full-size cooling tower has demonstrated that the procedure is simple, fast and can easily be implemented in practice.

A comparison of the effect of SSI on base isolation systems and fixed-base structures for soft soil

  • Karabork, T.;Deneme, I.O.;Bilgehan, R.P.
    • Geomechanics and Engineering
    • /
    • v.7 no.1
    • /
    • pp.87-103
    • /
    • 2014
  • This study investigated the effect of soil-structure interaction (SSI) on the response of base-isolated buildings. Seismic isolation can significantly reduce the induced seismic loads on a relatively stiff building by introducing flexibility at its base and avoiding resonance with the predominant frequencies of common earthquakes. To provide a better understanding of the movement behavior of multi-story structures during earthquakes, this study analyzed the dynamic behavior of multi-story structures with high damping rubber bearing (HDRB) behavior base isolation systems that were built on soft soil. Various models were developed, both with and without consideration of SSI. Both the superstructure and soil were modeled linearly, but HDRB was modeled non-linearly. The behavior of the specified models under dynamic loads was analyzed using SAP2000 computer software. Erzincan, Marmara and Duzce Earthquakes were chosen as the ground motions. Following the analysis, the displacements, base shear forces, top story accelerations, base level accelerations, periods and maximum internal forces were compared in isolated and fixed-base structures with and without SSI. The results indicate that soil-structure interaction is an important factor (in terms of earthquakes) to consider in the selection of an appropriate isolator for base-isolated structures on soft soils.

Construction stage analysis of fatih sultan mehmet suspension bridge

  • Gunaydin, Murat;Adanur, Suleyman;Altunisik, Ahmet Can;Sevim, Baris
    • Structural Engineering and Mechanics
    • /
    • v.42 no.4
    • /
    • pp.489-505
    • /
    • 2012
  • In this study, it is aim to perform the construction stage analysis of suspension bridges using time dependent material properties. Fatih Sultan Mehmet Suspension Bridge connecting the Europe and Asia in Istanbul is selected as an example. Finite element models of the bridge are modelled using SAP2000 program considering project drawing. Geometric nonlinearities are taken into consideration in the analysis using P-Delta large displacement criterion. The time dependent material strength variations and geometric variations are included in the analysis. Because of the fact that the bridge has steel structural system, only prestressing steel relaxation is considered as time dependent material properties. The structural behaviour of the bridge at different construction stages has been examined. Two different finite element analyses with and without construction stages are carried out and results are compared with each other. As analyses result, variation of the displacement and internal forces such as bending moment, axial forces and shear forces for bridge deck and towers are given with detail. It is seen that construction stage analysis has remarkable effect on the structural behaviour of the bridge.

Seismic assessment of historical masonry structures: The case of Amasya Taşhan

  • Karaca, Zeki;Turkeli, Erdem;Pergel, Senol
    • Computers and Concrete
    • /
    • v.20 no.4
    • /
    • pp.409-418
    • /
    • 2017
  • Turkey owns a very important cultural and historical heritage that bears the traces of thousands of years of culture and civilization. It is an inevitable duty to carry these treasuries to the future generations. In this paper, structural safety assessment and strengthening stages of one of these important historical heritages namely Amasya Taşhan was investigated in details as a case study. For this purpose, the detailed architectural projects of the structure with the information of all load carrying and structural elements were prepared. Then, the structural dynamic analyses were performed by using SAP2000. The internal forces obtained from the dynamic analyses determined the weak regions. By obtaining the information from dynamic analyses, the method of state of the art technique of application of the structure that needs structural strengthening was selected. The last step is the application of these precautions to the whole structure. At the end of this study, this study not also contains several strengthening techniques that is used in one masonry structure together but also provides a useful reference to the practicing engineers.