Effect of the Paclitaxel and Radiation in the Mucosa of the Small Bowel of Rat (흰쥐의 소장점막에 Paclitaxel(Taxol)과 방사선조사의 효과)

  • Lee Kyung-Ja
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.255-264
    • /
    • 1996
  • Purpose : Paclitaxel is a chemotherapeutic agent with potent microtubule stabilizing activity that arrests cell cycle in $G_2$-M Because $G_2$-M is the most radiosensitive Phase of the cell cycle, paclitaxel has potential as a cell cycle- specific radiosensitizer. This study was designed to investigate the ability of paclitaxel to increase the radiotoxicity in normal small bowel mucosa of the rat. materials and Methods : A sigle intraperitoneal infusion of paclitaxel (10mg/kg), and a single irradiation(8 Gy, x-ray) to the whole abdomen and combination of radiation(8 Gr, x-ray) 24 hours after paclitaxel infusion in the rats were done. The changes of jejunal mucosa, and kinetics of mitotic arrest and apoptosis in the jejunal crypt were defined at 6 hours - 5 days after each treatment histologically. Results : Paclitaxel blocked jejunal crypt cell in mitosis and induced minmal apoptosis. Mitotic arrest by paclitaxel was peaked at 6 hours after infusion and returned to normal by 24 hours. Radiation induced apoptosis and peaked at 6 hours and returned to normal by 24 hours. Combination of paclitaxel and radiation blocked crypt cell in mitosis at 3 days and induced apoptosis slightly at 6 hours and 24 hours and returned to normal by 3 days. The incidence of apoptosis in combined group at 6 hours was slightly higher than normal control but significantly lower than radiation alone group. The major changes of jejunal mucosa were nuclear vesicle and atypia which were appeared at 6 hours - 3 days and returned to normal by 5 days The degree of the mucosal changes are not different in 3 groups except for absence of inflmmatory reaction in radiation group. Conclusion : Mitotic arrest by paclitaxel was peaked at 6 hours and returned to normal by 24 hours and paclitaxel induced minimal apoptosis. Radiation induced apoptosis, peaked at 6 hours and returned to normal by 24 hours. Radiation-induced apoptosis was less in combined group which suggested that paclitaxel have a radioprotective effect when radiation was given 24 hours after paclitaxel infusion.

  • PDF

Magnetic resonance image-based tomotherapy planning for prostate cancer

  • Jung, Sang Hoon;Kim, Jinsung;Chung, Yoonsun;Keserci, Bilgin;Pyo, Hongryull;Park, Hee Chul;Park, Won
    • Radiation Oncology Journal
    • /
    • v.38 no.1
    • /
    • pp.52-59
    • /
    • 2020
  • Purpose: To evaluate and compare the feasibilities of magnetic resonance (MR) image-based planning using synthetic computed tomography (sCT) versus CT (pCT)-based planning in helical tomotherapy for prostate cancer. Materials and Methods: A retrospective evaluation was performed in 16 patients with prostate cancer who had been treated with helical tomotherapy. MR images were acquired using a dedicated therapy sequence; sCT images were generated using magnetic resonance for calculating attenuation (MRCAT). The three-dimensional dose distribution according to sCT was recalculated using a previously optimized plan and was compared with the doses calculated using pCT. Results: The mean planning target volume doses calculated by sCT and pCT differed by 0.65% ± 1.11% (p = 0.03). Three-dimensional gamma analysis at a 2%/2 mm dose difference/distance to agreement yielded a pass rate of 0.976 (range, 0.658 to 0.986). Conclusion: The dose distribution results obtained using tomotherapy from MR-only simulations were in good agreement with the dose distribution results from simulation CT, with mean dose differences of less than 1% for target volume and normal organs in patients with prostate cancer.

P53 Overexpression and Outcome of Radiation Therapy in Head & Neck Cancers (두경부종양 환자에서 p53의 과발현과 방사선치료결과)

  • Kim In Ah;Choi Ihl Bhong;Kang Ki Mun;Jang Ji Young;Kim Kyung Mi;Park Kyung Shin;Young Shin Kim;Kang Chang Suk;Cho Seung Ho;Kim Hyung Tae
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 1999
  • Purpose : Experimental studies have implicated the wild type p53 In cellular response to radiation. Whether altered p53 function can lead to changes in clinical radiocurability remains an area of ongoing study. This study was performed to investigate whether any correlation between change of p53 and outcome of curative radiation therapy in patients with head and neck cancels. Methods : Immunohistochemical analysis with a mouse monoclonal antibody (DO-7) specific for human p53 was used to detect to overexpression of protein in formalin fixed, paraffin-embedded tumor sample from 55 head and neck cancer patients treated with curative radiation therapy (median dose of 7020 cGy) from February 1988 to March 1996 at 51. Mary's Hospital. Overexpression of p53 was correlated with locoregional control and survival using Kaplan-Meier method. A Cox regression multi-variate analysis was peformed that included all clinical variables and status of p53 expression. Results : Thirty-seven (67.2$\%$) patients showed overexpression of p53 by immunohistochemical staining in their tumor. One hundred percent of oral cavity, 70$\%$ of laryngeal, 66.7$\%$ of oropharyngeal, 66.7$\%$ of hypopharyngeal cancer showed p53 overexpression (P=0.05). The status of p53 had significant relationship with stage of disease (P=0.03) and history of smoking (P=0.001). The overexpression of p53 was not predictive of response rate to radiation therapy. The locoregional control was not significantly affected by p53 status. Overexpression of p53 didn't have any prognostic implication for disease free survival and overall survival. Primary site and stage of disease were significant prognostic factors for survival. Conclusions : The p53 overexpression as detected by immunohistochemical staining had significant correlation with stage, primary site of disease and smoking habit of patients. The p53 overexpression didn't have any predictive value for outcome of curative radiation therapy in a group of head and neck cancers.

  • PDF

Design of Tapered Slot Antenna for UWB Communications (UWB 통신을 위한 테이퍼드 슬롯 안테나 설계)

  • Kim, Sun-Woong;Choi, Dong-You
    • Smart Media Journal
    • /
    • v.4 no.4
    • /
    • pp.64-69
    • /
    • 2015
  • In this paper, we have proposed a tapered slot antenna for UWB communication system. The tapered slot antenna has directional radiation and broad bandwidth. Proposed tapered slot antenna is designed using Ansys Inc. HFSS and its VSWR, return los, and radiation pattern is analyzed. Operating band of the antenna were satisfied -10 dB S11 and $VSWR{\leq}2$ in 2.7 ~ 4.8 GHz band. The radiation pattern of the antenna is showed in E-plane (YZ plane) and the H-plane (XZ plane) and the highest gain of 7.3 dBi is seen at 4.5 GHz. Therefore, proposed tapered slot antenna has wide bandwidth characteristic and directional for location awareness.

NOAA's Response Plan for Nuclear Emergencies

  • Hwang, Sun-Tae;Choi, Kil-Oung
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.2
    • /
    • pp.115-118
    • /
    • 2000
  • With reference to nuclear emergency information concerning the national emergency plan for nuclear accidents, the response plan for the atmospheric nuclear emergencies of the U.S. National Oceanic and Atmospheric Administration (NOAA) was reviewed and described for introducing an overview on it to the Korean Association for Radiation Protection (KARP).

  • PDF

Dosimetric Evaluation of an Automatically Converted Radiation Therapy Plan between Radixact Machines

  • Lee, Mi Young;Kang, Dae Gyu;Kim, Jin Sung
    • Progress in Medical Physics
    • /
    • v.31 no.4
    • /
    • pp.153-162
    • /
    • 2020
  • Purpose: We aim to evaluate the accuracy and effectiveness of an automatically converted radiation therapy plan between Radixact machines by comparing the original plan with the transferred plan. Methods: The study involved a total of 20 patients for each randomly selected treatment site who received radiation treatment with Radixact. We set up the cheese phantom (Gammex RMI, Middleton, WI, USA) with an Exradin A1SL ion chamber (Standard Imaging, Madison, WI, USA) and GAFCHROMIC EBT3 film (International Specialty Products, Wayne, NJ, USA) inserted. We used three methods to evaluate an automatically converted radiation therapy plan using the features of the Plan transfer. First, we evaluated and compared Planning target volume (PTV) coverage (homogeneity index, HI; conformity index, CI) and organs at risk (OAR) dose statistics. Second, we compared the absolute dose using an ion chamber. Lastly, we analyzed gamma passing rates using film. Results: Our results showed that the difference in PTV coverage was 1.72% in HI and 0.17% in CI, and majority of the difference in OAR was within 1% across all sites. The difference (%) in absolute dose values was averaging 0.74%. In addition, the gamma passing rate was 99.64% for 3%/3 mm and 97.08% for 2%/2 mm. Conclusions: The Plan transfer function can be reliably used in appropriate situations.

A unique Vietnam's red clay-based brick reinforced with metallic wastes for γ-ray shielding purposes: Fabrication, characterization, and γ-ray attenuation properties

  • Ta Van Thuong;O.L. Tashlykov;K.A. Mahmoud
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1544-1551
    • /
    • 2024
  • A unique brick series based on Vietnamese clay was manufactured at 114.22 MPa pressure rate for γ-ray attenuation purposes, consisting of (x) metallic waste & (90%-x) red clay mineral & 10% (hardener mixed with epoxy resin), where (x) is equal to the values 0%, 20%, 40%, 50%, and 70%. The impacts of industrial metal waste ratio in the structure and radiation protective characteristics were evaluated experimentally. The increase in metallic waste doping concentrations from 0% to 70% was associated with an increase in the manufactured brick's density (ρ) from 2.103 to 2.256 g/cm3 while the fabricated samples' porosity (Φ) decreased from 11.7 to 1.0%, respectively. Together with a rise in fabricated brick's density and a decrease in their porosities, the manufactured bricks' γ-ray attenuation capacities improved. The measured linear attenuation coefficient (μ, cm-1) was improved by 30.8%, 22.1%, 21.6%, and 19.7%, at Eγ equal to the values respectively 0.662, 1.173, 1.252, and 1.332 MeV, when the metallic waste concentration increased from 0% to 70%, respectively. The study demonstrates that manufactured bricks exhibit superior radiation shielding properties, with radiation protection efficiencies of 88.4%, 90.0%, 91.7%, 92.1%, and 92.4% for bricks with industrial metal waste contents of 0%, 20%, 40%, 50%, and 70%, respectively, at γ-ray energy (Eγ) of 1.332 MeV.

The Expression of Oncogenes on the Radiation-induced Apoptosis in SCK Mammary Adenocarcinoma Cell Line (SCK 선암세포주에서 방사선 조사에 의해 유도되는 Apoptosis에 미치는 암유전자의 발현)

  • Lee Hyung Sik;Park Hong Kyu;Moon Chang Woo;Yoon Seon Min;Hur Won Joo;Jeong Su Jin;Jeong Min Ho;Lee Sang Hwa
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.70-77
    • /
    • 1999
  • Purpose : The expression of p53, P211WAF/CIP, Bcl-2, and Bax underlying the radiation-induced apoptosis in different pH environments using SCK mammary adenocarcinoma cell line was investigated. Materials and Methods Mammary adenocarcinoma cells of hi) mice (SCK cells) in exponential growth phase were irradiated with a linear accelerator at room temperature. The cells were irradiated with 12 Gy and one hour later, the media was replaced with fresh media at a different pHs. After Incubation at 37Microbioiogy, College of Medicine Dong A University for 0$\~$48 h, the extort of apoptosis was determined using agarose gel electrophoresis and flow cytometry. The progression of cells through the cell cycle after irradiation in different pHs was also determined with flow cytometry. Western blot analysis was used to monitor p53, p211WAFfCIP, Bcl-2, and Bu protein levels. Results : The induction of apoptosis by irradiation in pH 6.6 medium was markedly less than that in pH 7.5 medium. The radiation-induced G2IM arrest in pH 6.6 medium lasted markedly longer than that in pH 7.5 medium. Considerable amounts of p53 and p21 proteins already existed at pH 7.5 and increased the level of p53 and p21 significantly after 12 Gy X-irradiation. An incubation at pH 6.6 after 12 Gy X-irradiation did not change the level of p53 and p21 protein levels significantly. Bcl-2 proteins were not significantly affected by radiation and showed no correlation with cell susceptibility to radiation-induced apoptosis in different pHs. An exposure to 12 Gy of X-rays increased the level of Bax protein at pH 7.5 but at pH 6.6, it was slight. Conclusions : The molecular mechanism underlying radiation-induced apoptosis in dinerent pH environments using SCK mammary adenocarcinoma cell line was dependent of the expression p53 and P211YVAF/CIP proteins. We may propose following hypothesis that an acidic stress augments the radiation-induced G2iM arrest, which inhibiting the irradiated cells undergo post-mitotic apoptosis. The effects of environmental acidity on anti-apoptotic and pro-apoptotic function of Bcl-2 family was unclear in SCK mammary adenocarcinoma cell line.

  • PDF

Usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit (안와 주변 방사선 치료 시 수정체 피폭선량 감소를 위한 2차 차폐의 유용성 평가)

  • Kwak, Yong Kuk;Hong, Sun Gi;Ha, Min Yong;Park, Jang Pil;Yoo, Sook Hyun;Cho, Woong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.87-95
    • /
    • 2015
  • Purpose : This study presents the usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit. Materials and Methods : We accomplished IMRT treatment plan similar with a real one through the computed treatment planning system after CT simulation using human phantom. For the secondary shield, we used Pb plate (thickness 3mm, diameter 25mm) and 3 mm tungsten eye-shield block. And we compared lens dose using OSLD between on TPS and on simulation. Also, we irradiated 200 MU(6 MV, SPD(Source to Phantom Distance)=100 cm, $F{\cdot}S\;5{\times}5cm$) on a 5cm acrylic phantom using the secondary shielding material of same condition, 3mm Pb and tungsten eye-shield block. And we carried out the same experiment using 8cm Pb block to limit effect of leakage & transmitted radiation out of irradiation field. We attached OSLD with a 1cm away from the field at the side of phantom and applied a 3mm bolus equivalent to the thickness of eyelid. Results : Using human phantom, the Lens dose on IMRT treatment plan is 315.9cGy and the real measurement value is 216.7cGy. And after secondary shield using 3mm Pb plate and tungsten eye-shield block, each lens dose is 234.3, 224.1 cGy. The result of a experiment using acrylic phantom, each value is 5.24, 5.42 and 5.39 cGy in case of no block, 3mm Pb plate and tungsten eye-shield block. Applying O.S.B out of the field, each value is 1.79, 2.00 and 2.02 cGy in case of no block, 3mm Pb plate and tungsten eye-shield block. Conclusion : When secondary shielding material is used to protect critical organ while irradiating photon, high atomic number material (like metal) that is near by critical organ can be cause of dose increase according to treatment region and beam direction because head leakage and collimator & MLC transmitted radiation are exist even if it's out of the field. The attempt of secondary shield for the decrease of exposure dose was meaningful, but untested attempt can have a reverse effect. So, a preliminary inspection through Q.A must be necessary.

  • PDF

A Numerical Study of Smoke Movement with Radiation in Atrium Fires (아트리움에서 화재 발생시 복사가 고려된 연기거동에 대한 수치해석 연구)

  • 정진용;유홍선;홍기배
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.7-15
    • /
    • 2001
  • This paper describes the smoke filling process of a fire field model based on a self-developed SMEP (Smoke Movement Estimating Program) codo to the simulation of fire induced flows in the atrium space (SIVANS atrium at Japan) containing smoke radiation effect. The SMEP using PISO algorithm solves conservation equations for mass, momentum, energy and species, together with those for the modified k-$\varepsilon$ turbulence model with buoyancy term. Also it solves the radiation equation using the discrete ordinates method. The result of the calculated smoke temperature containing radiation effect has shown a better prediction than the result calculated by only convection effect in comparison with the experimental data. This seems to come from the radiation effect of $H_2$O and $CO_2$ gas under smoke productions. Thus, the consideration of the radiation effect under smoke in fire should be necessary in order to get more realistic result. Also the numerical results indicated that the smoke layer is developing at a rate of about 0.1 m/s. It would take about 450 seconds after starting the ultra fast fire of 560 kW that the smoke layer move down to 1.5m above the escape level.

  • PDF