• Title/Summary/Keyword: S-peak amplitude

Search Result 130, Processing Time 0.028 seconds

Nondestructive Evaluation of Adhesive Bonding Quality by Measurements of Peak Amplitude of Simulated Stress Wave (모의 음향 방출 신호의 Peak Amplitude측정을 통한 복합 재료 접합부의 비파괴평가)

  • Son, Y.H.;Lee, J.O.;Lee, S.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.2
    • /
    • pp.357-363
    • /
    • 1995
  • Disbond size of adhesively bonded single lap and double lap joints CFRP composite specimens has been evaluated using acousto-ultrasonic(AU) technique. Frequency spectra for all specimens were obtained by measuring peak amplitude of the stress wave propagated through the bond-lines. By analyzing these frequency spectra, peak amplitude was found to be proportional to fractional bonding area and to be maxima at the fundamental and the third order higher harmonic frequencies of specimen thickness mode. The disbond size can be evaluated quantitatively and this technique can be applied to real structures if the reference specimens are prepared in advancve.

  • PDF

Effects of Load Center of Gravity and Feet Positions on Peak EMG Amplitude at Low Back Muscles While Lifting Heavy Materials (중량물 들기 작업시 물체 무게중심 및 발의 위치가 허리 근육의 최대 EMG 진폭에 미치는 영향)

  • Kim, Sun-Uk;Han, Seung Jo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.3
    • /
    • pp.257-264
    • /
    • 2012
  • Objectives: This study's aims were to evaluate the effects of load center of gravity within an object lifted and feet placements on peak EMG amplitude acting on bilateral low back muscle groups, and to suggest adequate foot strategies with an aim to reducing low back pain incidence while lifting asymmetric load. Methods: The hypotheses that asymmetric load imposes more peak EMG amplitude on low back muscles contralateral to load center of gravity than symmetric load and maximum peak EMG amplitude out of bilateral ones can be relieved by locating one foot close to load center of gravity in front of the other were established based on biomechanics including safety margin model and previous researches. 11 male subjects were required to lift symmetrically a 15.8kg object during 2sec according to each conditions; symmetric load-parallel feet (SP), asymmetric load-parallel feet (AP), asymmetric load-one foot contralateral to load center of gravity in front of the other (AL), and asymmetric load-one foot ipsilateral to load center of gravity in front of the other (AR). Bilateral longissimus, iliocostalis, and multifidus on right and left low back area were selected as target muscles, and asymmetric load had load center of gravity 10cm deviated to the right from the center in the frontal plane. Results: Greater peak EMG amplitude in left muscle group than in right one was observed due to the effect of load center of gravity, and mean peak EMG amplitudes on both sides was not affected by load center of gravity because of EMG balancing effect. However, the difference of peak EMG amplitudes between both sides was significantly affected by it. Maximum peak EMG amplitude out of both sides and the difference of peak EMG amplitude between both sides could be reduced with keeping one foot ipsilateral to load center of gravity in front of the other while lifting asymmetric load. Conclusions: It was likely that asymmetric load lead to the elevated incidence of low back pain in comparison with symmetric load based on maximum peak EMG amplitude occurrence and greater imbalanced peak EMG amplitude between both sides. Changing feet positions according to the location of load center of gravity was suggested as one intervention able to reduce the low back pain incidence.

Accuracy Improvement Methode of Step Count Detection Using Variable Amplitude Threshold (가변 진폭 임계값을 이용한 걸음수 검출 정확도 향상 기법)

  • Ryu, Uk Jae;Kim, En Tae;An, Kyung Ho;Chang, Yun Seok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.2 no.6
    • /
    • pp.257-264
    • /
    • 2013
  • In this study, we have designed the variable amplitude threshold algorithm that can enhance the accuracy of step count using variable amplitude. This algorithm converts the x, y, z sensor values into a single energy value($E_t$) by using SVM(Signal Vector Magnitude) algorithm and can pick step count out over 99% of accuracy through the peak data detection algorithm and fixed peak threshold. To prove the results, We made the noise filtering with the fixed amplitude threshold from the amplitude of energy value that found out the detection error was increasing, and it's the key idea of the variable amplitude threshold that can be adapted on the continuous data evaluation. The experiment results shows that the variable amplitude threshold algorithm can improve the average step count accuracy up to 98.9% at 10 Hz sampling rate and 99.6% at 20Hz sampling rate.

The Effects of Lift-Off from Wall Thinning Signal in Pulsed Eddy Current Testing

  • Park, Duck-Gun;Angani, C.S.;Kishore, M.B.;Kim, C.G.;Lee, D.H.
    • Journal of Magnetics
    • /
    • v.17 no.4
    • /
    • pp.298-301
    • /
    • 2012
  • In order to know the effect of surface irregularity in the detection of local wall thinning of pipeline using pulsed eddy current (PEC), the lift-off effects on PEC signal have been investigated. Three kinds of parameters in the PEC signal, which is "peak amplitude", "time to peak amplitude" and "time to zero crossing" are analyzed to separate the lift-off effects in the PEC signal. The distance from sensor to the bottom of sample which is the total thickness of combined insulator and sample is kept constant. The magnitude of the differential peak amplitude is increased with increasing sample thickness, the time to peak amplitude is increased with increasing the sample thickness. To determine the effect of lift-off, a number of balanced transient responses combining wall thinning locations and lift-off distances were plotted.

Comparison of Peak EMG Amplitude on Low Back Muscles according to Asymmetric Load Center of Gravity and Trunk Lateral Bending while Lifting (들기 작업시 중량물의 비대칭 무게중심 및 상체 옆으로 기울임에 따른 허리근육의 Peak EMG 진폭 비교)

  • Han, Seung Jo;Kim, Sun-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4629-4635
    • /
    • 2012
  • This study was aimed at the relationship between peak EMG amplitude on low back muscles acting on L5/S1 and load center of gravity, trunk lateral bending while lifting an object. Musculoskeletal disorders including low back pain can occur even when handling heavy objects only once as well as when doing non-heavy materials repeatedly. 11 male subjects with average 23 age were required to lift a 15.8kg object symmetrically three times. Peak EMG amplitudes on 6 muscles related with L5/S1 were recorded and analyzed. The lifting conditions consisted of lifting symmetric load with no trunk lateral bending, asymmetric load with no trunk lateral bending, and asymmetric load with trunk lateral bending to the load center of gravity within an object. The results showed that peak EMG amplitude on back muscles contralateral to load center of gravity was observed greater in comparison with the symmetric load. Also, in case of lifting asymmetric load the posture with trunk lateral bending increased peak EMG amplitude on muscles contralateral to load center of gravity more than with no trunk lateral bending. This research can be used as one administrative intervention in order to reduce the low back pain incidence with suggesting workers that they keep the trunk not bending to load center of gravity if possible when lifting a heavy asymmetric object.

A Study for the Distinction between Denervation Potentials and Endplate Spikes for the Diagnosis of Neuropathy (신경질환의 진단을 위한 탈신경 전위와 종판 전위의 구별에 관한 연구)

  • 임재중;김남균;황윤성;박인선
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.4
    • /
    • pp.451-459
    • /
    • 1999
  • During the electromyographic evaluation for the diagnosis of neuropathy, presence for site of lesion could be predicted by a detection of denervation potentials such as fibrillation potentials or positive sharp waves in a group of muscles. Unfortunately, since denervation potentials are distinguished by examiner's experience, it is possible to make mistake identifying endplate spikes as a denervation potential. The aim of the study was to extract parameters to make an algorithm for quantitative distinction between denervation potentials and endplate spikes. It will help to minimize the examiner's bias and to localize the site of lesion thus increase the reliability on EMG diagnosis. There types of signals, endplate spike, fibrillation potential and positive sharp wave were obtained from the EDB(extensor digitorum brevis) muscle using then neuropathic patients. Eight parameters such as duration, area, slope, peak-to-peak amplitude, positive peak negative peak amplitude, ratio of positive to negative peak amplitude, and number of phase were extracted and compared. As a results, peak-to-peak amplitude, positive peak amplitude, ratio of positive to negative peak amplitude showed statistically significant differences between endplate spikes and denervation potentials. It was concluded that those parameters could be used to establish an algorithm which will improve the accuracies in automated quantitative EMG diagnosis.

  • PDF

Inter-Rater Reliability of the Deep Tendon Reflex by using EMG Electric Reflex Hammer (근전도 전자 망치를 이용한 깊은힘줄반사의 측정자 간 신뢰도)

  • Lee, Jeong-Woo;Seo, Tae-Hwa
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.4
    • /
    • pp.137-143
    • /
    • 2022
  • Purpose : The purpose of this study was to evaluate the reliability analysis of the deep tendon reflex by using electromyography (EMG). Methods : The study was tested on 30 volunteers who are women in their 20s. Using an electronic reflective hammer of EMG, deep tendon reflex was measured on all subjects with the participation of three trained physical therapists as raters. First, the subjects were comfortably seated on a table with their knees bent at 90 °. The three raters tapped the electric hammer at intervals of 10 seconds to avoid habituation until a total of 10 compound muscle action potential records were collected. Intraclass correlation coefficients (ICCs) were calculated to assess the inter-rater reliability of the deep tendon reflex with the use of EMG. The items of analysis included amplitude (mV), latency (ms), duration (ms), and area (mV × ms) of the compound evoked potentials. Results : Based on the average records of 10 compound muscle action potential, excellent reliability (ICC: .912) was achieved in terms of area, and there was good reliability in terms of latency (ICC: .795) and duration (ICC: .800). In the shortest latency of the compound muscle action potential, good reliability was achieved in terms of amplitude (ICC: .865), duration (ICC: .781), and area (ICC: .832). In the amplitude of peak-to-peak of compound muscle action potential, excellent reliability was recorded in terms of amplitude (ICC: .924), and good reliability was recorded in terms of duration (ICC: .801) and area (ICC: .874). Conclusion : The findings in this study indicate that electromyography via an electric hammer is a reliable method of assessing and measuring deep tendon reflexes. Especially, it may be an excellent gauge in the area of average values of the compound muscle action potentials and the amplitude of peak-to-peak of compound muscle action potentials.

Characteristics of long-period swells measured in the near shore regions of eastern Arabian Sea

  • Glejin, Johnson;Kumar, V. Sanil;Amrutha, M.M.;Singh, Jai
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.4
    • /
    • pp.312-319
    • /
    • 2016
  • Measured wave data covering two years simultaneously at 3 locations along the eastern Arabian Sea reveals the presence of long-period (peak wave period > 18 s) low-amplitude waves (significant wave height < 1 m) and the characteristics of these waves are described in this article. In a year, 1.4-3.6% of the time, the low-amplitude long-period swells were observed, and these waves were mainly during the nonmonsoon period. The wave spectra during these long-period swells were multi-peaked with peak wave period around 18.2 s, the secondary peak period around 13.3 s and the wind-sea peak period at 5 s. The ratio of the spectral energy of the wind-sea peak and the primary peak (swell) was slightly higher at the northern location (0.2) than that at the southern location (0.15) due to the higher wind speed present at the northern location.

Effects of Ultrasonic Amplitude on Electrochemical Properties During Cavitation of Carbon Steel in 3.5% NaCl Solution

  • Jang, I.J.;Kim, K.T.;Yoo, Y.R.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.163-173
    • /
    • 2020
  • Cavitation corrosion in many industrial plants has recently become a serious issue. Cavitation corrosion has generally been investigated using a vibratory method based on ASTM G32 standard, and the test can be divided into direct cavitation and indirect cavitation. Cavitation corrosion test uses the vibration frequency of the horn of 20 kHz with constant peak-to-peak displacement amplitude. In this work, the peak-to-peak amplitude was controlled from 15 ㎛ to 85 ㎛, and electrochemical measurements were obtained during indirect cavitation. The relationship between cavitation corrosion rate and electrochemical properties was discussed. Corrosion steps of carbon steel at the initial stage under cavitation condition in 3.5 % NaCl can be proposed. When the cavitation strength is relatively low, corrosion of the steel is more affected by the electrochemical process than by the mechanical process; but when the cavitation strength is relatively high, corrosion of the steel is affected more by the mechanical process than by the electrochemical process. This work confirmed that the critical ultrasonic amplitude of 0.42 %C carbon steel is 53.8 ㎛, and when the amplitude is less than 53.8 ㎛, the corrosion effect during the cavitation corrosion process is higher than the mechanical effect.

Inactivation of N-Type Calcium Current in Rat Sympathetic Neurons

  • Goo, Yong-Sook;Keith S. Elmslie
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 1999.06a
    • /
    • pp.52-52
    • /
    • 1999
  • Inactivation of N-type calcium current has been reported to be voltage dependent (Jones & Marks, 1989) and $Ca^{2+}$ dependent(Cox & Dunlap, 1994). We examined inactivation by recording currents from the same cell both in [B $a^{2+}$]$_{o}$ and [C $a^{2+}$]$_{o}$ in rat sympathetic neurons. With 11 mM internal EGTA, fractional inactivation[l-(current amplitude at the end of 5 sec pulse/peak current amplitude [1-(current amplitude at the end of 5 sec pulse/peak current amplitude)] was larger in $Ca^{2+}$(0.80$\pm$0.07) than in $Ba^{2+}$(0.69$\pm$0.10)(n=31, p<0.001), but the current traces were nicely fitted with two exponential components both in $Ba^{2+}$ and $Ca^{2+}$.(omitted)ted)ted)

  • PDF