• Title/Summary/Keyword: S-Parameter Measurement

Search Result 379, Processing Time 0.036 seconds

A Study on QoS Measurement & Evaluation for MPEG Transmission in Network (통신망에서 MPEG 영상 전송을 위한 QoS 측정 및 평가에 관한 연구)

  • Suh Jae-Chul
    • Journal of Digital Contents Society
    • /
    • v.3 no.1
    • /
    • pp.101-111
    • /
    • 2002
  • Lately development of network around Internet expands range of data traffic to multimedia information, and so for the guarantee of multimedia services end-to-end QoS(Quality of Service) must service because comparing with existing Internet service can not support For satisfying those QoS requirements, network have to guarantee not only network on parameter, such as delay, jitter, throughput but also system resources like CPU utilization, memory usage. Therefore it is urgent to develop QoS based middleware to distribute multimedia data and maximize network utilization in the limited resource environment. And it must be necessary of network to provide end-to-end QoS(Quality of Service) for multimedia applications. Multimedia applications want that QoS which satisfy their own service properties be guaranteed Then, We must analyze those necessary QoS requirements md define QoS parameter which specify as two viewpoint, user's and network's perspective. Therefore network provider supplying network for usual user and university, enterprise must want to find about their own network performance and problem. It is essential for network manager to want to use a tool like this. On the basis of technique about QoS test-bed in the AIM network, We studied on the method of QoS measurement and management about end-to-end connection in the Internet. We measured network status about end-to-end connection and analyze the result of performance.

  • PDF

Designing an Input Parameters Setting Model for Reducing the Difficulty of Input Parameters Estimations in Cross Impact Analysis (기술상호효과분석의 입력변수 추정 난이도 경감을 위한 입력변수 설정모형의 설계)

  • Jun, Jungchul;Kwon, Cheolshin
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.42 no.2
    • /
    • pp.35-48
    • /
    • 2017
  • As the technology convergence paradigm emerges, the need for "CIA techniques" to analyze the mutual effects of technology is increasing. However, since the CIA input parameter estimation is difficult, the present study suggests a "CIA input parameter setting model" to alleviate the difficulty of CIA input parameter estimation. This paper is focused on the difference of measurement difficulty by each scale which expert's estimation behavior was defined as measurement activity quantifying the judgment of future technology. Therefore, this model is designed to estimate the input variable as a sequence or isometric scale that is relatively easy to measure, and then converts it into a probability value. The input parameter setting model of the CIA technique consists of three sub-models : 'probability value derivation model', 'influence estimation model', and 'impact value calculation model', in order to develop a series of models the Thurstone V model, Regression Analysis, etc has been used.

A Study on the Roughness Measurement for Joints in Rock Mass Using LIDAR (LIDAR를 이용한 암반 절리면의 거칠기 측정에 관한 연구)

  • Lee, Sudeuk;Jeon, Seokwon
    • Tunnel and Underground Space
    • /
    • v.27 no.1
    • /
    • pp.58-68
    • /
    • 2017
  • According to the development of optical technology, the capacity of LIDAR equipments has been greatly improved to get rock mass characteristics precisely and accurately enough and it has been lightened and popularized so that it can be easily used in the field. In this study, we examined the applicability of roughness measurement for joints in a rock slope using LIDAR technique. A triangular irregular network was constructed using LIDAR and a patch, which is a plane structure of discontinuity on rock mass measured from LIDAR scanning, was extracted to estimate the roughness of the rock slope. Four different kinds of roughness parameters were analyzed to find out their correlation with JRC for various point intervals. Among them, $R_s$ parameter was used to measure the roughness of a patch. Regression analysis between four roughness parameters and JRC with respect to point interval was performed. All the roughness parameters decreased with the increase of point interval. In addition, the parameter value showed greater decrease for rougher surfaces. A method of roughness measurement using $R_s$ parameter on rock slope discontinuities was suggested which showed slight overestimation of the real roughness value.

Sensitivity Analysis in the Estimation of Complex Elastic Modulus of Viscoelastic Materials by Transmissibility Measurements (전달율 측정에 의한 점탄성재료의 복소탄성계수 추출시의 민감도 분석)

  • 안태길;허진욱;김광준
    • Journal of KSNVE
    • /
    • v.2 no.2
    • /
    • pp.99-106
    • /
    • 1992
  • The complex Young's modulus of a viscoelastic material can be obtained as a function of frequency from the measurements of relative motion between the two ends of a bar-type specimen. Non-resonance method is usually used to obtain the complex Young's modulus over wide range of frequency including resonance points, while in resonance method information at resonance frequencies only is used. However, the complex Young's modulus obtained by the non-resonance method is often unreliable in the anti-resonance frequency regions because of the measurement noise problems. In this study, the effects of the random measurement errors on estimating the complex Young's modulus are studied in the aspect of sensitivity, and how to obtain the reliable frequency region for a given measurement error level is shown. The usable frequency regions in determining the complex Young's modulus are represented by a non-dimensional parameter formed with the wave length and specimen length.

  • PDF

Experimental Analysis on Temperature Compensation of Capacitive Voltage Divider for a Pulsed High Voltage Measurement (고전압 펄스신호 측정용 분압기의 온도보상에 관한 실험)

  • Jang, S.D.;Son, Y.G.;Kwon, S.J.;Oh, J.S.;Cho, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1530-1533
    • /
    • 2005
  • Total 12 units of high power klystron-modulator systems as microwave source is under operation for 2.5-GeV electron linear accelerator in Pohang Light Source(PLS) linac. RF power and beam power of klystron are precisely measured for the effective control of electron beam. A precise measurement and measurement equipment with good response characteristics are required for this. Input power of klystron is calculated from the applied voltage and the current on its cathode. Tiny measurement error severely effects RF output power value of klystron. Therefore, special care is needed to measure precise beam voltage. Capacitive voltage divider(CVD) unit is intended for the measurement of beam voltage of 400 kV generated from the pulsed klystron-modulator system. Main parameter to determine the standard capacitance in the high arm of CVD is dielectric constant of insulation oil. Therefore CVD should be designed to have a minimum capacitance variation due to voltage, frequency and temperature in the measurement range. This paper will discuss the analysis of capacitive voltage divider for a pulsed high-voltage measurement, and the empirical relations between capacitance and oil temperature variation.

  • PDF

Fundamental Small-signal Modeling of Li-ion Batteries and a Parameter Evaluation Using Levy's Method

  • Zhang, Xiaoqiang;Zhang, Mao;Zhang, Weiping
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.501-513
    • /
    • 2017
  • The fundamental small-signal modeling of lithium-ion (Li-ion) batteries and a parameter evaluation approach are investigated in this study to describe the dynamic behaviors of small signals accurately. The main contributions of the study are as follows. 1) The operational principle of the small signals of Li-ion batteries is revealed to prove that the sinusoidal voltage response of a Li-ion battery is a result of a sinusoidal current stimulation of an AC small signals. 2) Three small-signal measurement conditions, namely stability, causality, and linearity, are proved mathematically proven to ensure the validity of the frequency response of the experimental data. 3) Based on the internal structure and electrochemical operational mechanism of the battery, an AC small-signal model is established to depict its dynamic behaviors. 4) A classical least-squares curve fitting for experimental data, referred as Levy's method, are introduced and developed to identify small-signal model parameters. Experimental and simulation results show that the measured frequency response data fit well within reading accuracy of the simulated results; moreover, the small-signal parameters identified by Levy's method are remarkably close to the measured parameters. Although the fundamental and parameter evaluation approaches are discussed for Li-ion batteries, they are expected to be applicable for other batteries.

High Frequency Permeability Measurement of Magnetic Films (자성막의 고주파 투자율 측정)

  • Choi, Hyung;Jang, Kyung-Do;Kwon, Sang-Il
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.1
    • /
    • pp.71-78
    • /
    • 1995
  • We introduced and compared the two methods, 'figure-8 coil method' and 's-parameter method', to measure high frequency permeability of magnetic films. We made a permeameter by using s-parameter method and discussed about problems and solutions in measuring permeability. We can measure the permeability rapidly and exactly up to 200 MHz with the aid of computer program and the low level permeance detection limit is about $1\mu\textrm{m}$.

  • PDF

Measurement of Stokes parameter changes due to blood glucose using PS-LCI (PS-LCI를 이용한 혈당 농도에 따른 Stokes 파라미터 측정)

  • 이상원;김법민
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.258-259
    • /
    • 2003
  • 최근 수년간 polarimetry, Raman spectroscopy, near infrared (NIR) absorption spectroscopy, NIR scattering, optoacoustics 등의 방법을 통하여 비침습적으로 Glucose의 농도를 측정하려는 연구가 많이 시도되었다. 일반적으로 이들 방법은 sensitivity 와 signal-to-noise ratio가 매우 낮고 복잡한 알고리즘이 요구되어져 glucose 농도 측정에 한계가 있음이 드러났다. 본 연구에서는 polarization sensitive low coherence interferometer (PS-LCI) 기법을 이용하여 농도에 따른 stokes parameters를 측정함으로써 비침습적으로 glucose를 측정하는 것이 가능한지 알아보는데 그 목적이 있다. (중략)

  • PDF

A Study on the optical aspects of machine vision based dimensional measurement system (정밀 좌표측정용 머신비전 시스템의 광학적 해석에 관한 연구)

  • Lee, E.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.2
    • /
    • pp.149-163
    • /
    • 1994
  • A novel method of dimensional measurement using machine vision, which is called Landmark Tracking System, has been developed. Its advantages come form tracking only the bright, standard shaped "landmarks" which are made from retroreflective sheets. In the design of the LTS, it is essential to know the relationship between optical parameters and their influence on system performance. Such optical parameters include the brightness of landmark image, the illumination system design, and the choice of imaging optics. And the performance of retroreflective material also plays important role in the LTS performances. Influences of such optical parameters on LTS's dimensional measurement characteristics are investigated, with respect to the retroreflective material, the imaging optics, and the illumination system. Measuremtn errors due to parameter variations are also analyzed. Experiments are performed with a LTS prototype. Retroreflective characteristics are verified, and the LTS's measurement performances are measured in the form of repeatability and accuracy. Experimental results shgow that the LTS has repeatability better than 1/30,000 of a field of view(30 degrees), and accuracy better tha 1/3,000 of a field fo view.d fo view.

  • PDF