• Title/Summary/Keyword: S-N line

Search Result 872, Processing Time 0.027 seconds

Charge Redistribution of Pt-based Alloys

  • Lim, K.Y.;Chung, Y.D.;Kwon, S.Y.;Lee, Y.S.;C.N.Whang;Y.Jeon;Park, B.S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.171-171
    • /
    • 1999
  • We studied the charge redistribution in the Pt-M (M=Cu, Co) alloys by X-ray Absorption Near Edge Spectroscopy(XANES) and X-ray Photoelectron Spectroscopy(XPS). These analysis tools provide us information about the charge transfer in the valence band of intermetallic bonding. The samples were prepared by arc-melting method. After annealing this samples in vacuum for several hours, we cold get the ordered samples, which were confirmed with XRD analysis. the core and valence level energy shift in these system were investigated by Mg $K\alpha$(1253.6eV) x-ray source for Pt-Co alloys and monochromatized Al $K\alpha$ (1486.6eV) for Pt-Cu alloys. Pt L2, L3-edge, and Cu, Co K-edge XANES spectra were measured with the total electron-yield mode detector at the 3Cl beam line of the PLS (Pohang light source0. from the changes of White line (WL) area and the core level shifts of the each metal sites, we can obtain the information about the electrons participating in the intermetallic bonding of the Pt-Cu and Pt-Co alloys.

  • PDF

교차로 방향별 차선공동이용 연구

  • 김동녕
    • Journal of Korean Society of Transportation
    • /
    • v.6 no.2
    • /
    • pp.49-56
    • /
    • 1988
  • Alternate use of lane at a signalized intersection is a quite different control of the operation of an intersection. This control introduces a new stop line and signal before the original stop line. All of the lanes between the two stop lines are used for left turn traffic or through traffic at a time. The purpose of the control is increasing the capacity of a n intersection without widening the approach width. this paper contains a study on the condition of a application, the proper distances between the two stop lines, the reasonable offsets(rear) to guarantee clearing the vehicles of previous phase, the comparison of approach capacity between the existing control and this control. The study results reveals that the offsets(rear) are rather stable showing the range(maximum value minus minimum value) of it's value does not exceed 3.6 seconds according to the field data. The approach capacity will be increased by 27%, 43%, 59%, 84% when the distances between the stop lines are 30.0m respectively. The control might have theoretical limitation to operate in practice. So an experimental application of the control at some suitable intersections prior to expanding it.

  • PDF

The Research of suitability of Medium Access Control Layer based on High-Speed Power Line Communications (고속 PLC에 기반한 매체접근제어 계층의 적합성 연구)

  • Lee, Joo-Hwa;Lee, Seong-Won;Hong, Choong-Seon;Lee, Jae-Jo
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06d
    • /
    • pp.413-414
    • /
    • 2012
  • 본 연구는 고속 PLC(PLC: Power Line Communications)를 구현하기 위해, 전력선을 통해서 통신을 하고, 시스템 간의 정보를 교환하는 매체접근제어(MAC) 계층 적합성 인증하기 위한 실험에 관한 연구이다. 연구과정은 물리계층(PHY) 및 매체제어접근계층(MAC) 규격을 바탕으로 하고, 200Mbps의 고속전송이 가능한 PLC 칩(Chip)을 대상으로 한다.

New technology trend and characteristic for GIL (GIL(Gas Insulated Line)에 관한 신기술 동향 및 특징)

  • Jung, Si-Hwan;Kim, Chel-Soo;Kang, Cheul-Won;Kim, Wan-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.99-101
    • /
    • 2006
  • As the same concept with GIB, GIL(Gas Insulated Line) has been established and run for the first time in New Jersey, America, in 1972. At the beginning, the installation condition of GIL was complicated and the construction cost was excessive, so it was not economical, but the construction cost was substantially reduced with the use of insulation material which is the mixture of $SF_6$ and $N_2$ Gas in Germany, in 1990s. And also comparing to cable, GIL has lots of advantages, such as being capable of the high voltage transmission, being applied to reclosing and lowering the strength of electromagnetic force, Due to these advantages, GIL is recently accepted in many countries.

  • PDF

A numerical study on convective heat transfer characteristics at the vessel surface of the Korean Next Generation Reactor (차세대 원자로 용기내 vessel 내면에서의 대류 열전달특성에 관한 수치해석적 연구)

  • Jung, S.D.;Kim, C.N.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.228-233
    • /
    • 2000
  • The Korean Next Generation Reactor(KNGR) is a Pressurized Water Reactor adopting direct vessel injection(DVI) to optimize the performance of emergency core cooling system(ECCS). In a certain accident, however, pressurized thermal shock(PTS) of the vessel due to the sudden contact with the injected cold water is expected. In this paper, an accident of Main Steam Line Break(MSLB) has been numerically investigated with direct vessel injections and an increased volume flow rate in some cold legs. Using FLUENT code, temperature distributions of the fluid in the downcomer and of reactor vessel including the core region have been calculated, together with the distribution of convective heat transfer coefficient(CHTC) at the cladding surface of the reactor vessel. The result shows that some parts of the core region of the reactor vessel have higher temperature gradient expressing higher thermal stress.

  • PDF

GLOBAL CONVERGENCE OF A MODIFIED BFGS-TYPE METHOD FOR UNCONSTRAINED NON-CONVEX MINIMIZATION

  • Guo, Qiang;Liu, Jian-Guo
    • Journal of applied mathematics & informatics
    • /
    • v.24 no.1_2
    • /
    • pp.325-331
    • /
    • 2007
  • To the unconstrained programme of non-convex function, this article give a modified BFGS algorithm associated with the general line search model. The idea of the algorithm is to modify the approximate Hessian matrix for obtaining the descent direction and guaranteeing the efficacious of the new quasi-Newton iteration equation $B_{k+1}s_k=y^*_k,\;where\;y^*_k$ is the sum of $y_k\;and\;A_ks_k,\;and\;A_k$ is some matrix. The global convergence properties of the algorithm associating with the general form of line search is proved.

Effects of Blank Design factors on Stretch Flange Forming of the Tailored Blank Using Taguchi Method (다구찌법을 이용한 테일러드 블랭크의 신장플랜지 성형에 미치는 설계 인자의 영향 분석)

  • 백승엽;권재욱;이경돈
    • Transactions of Materials Processing
    • /
    • v.9 no.4
    • /
    • pp.339-347
    • /
    • 2000
  • For the successful forming of tailored blank, it is important to control the deformation of the stretch flange mode, which is strong1y dependent upon the location of weld line and blank shape. In order to investigate the effects of tailored blank design factors on the stretch flange forming, we made the model die which can simulate stretch flange mode. Taguchi method was employed to analyze the sensitivity of blank design factors for the forming of tailored blank. From the results of experiment S/N ratios were calculated and using Variance Analysis, significance of parameters and optimal condition of each factors were extracted. Based on these analyses, the weld line height and the strength ratio and the arc center height were selected as effective parameter. The analysed result was practically applied for Side outer panel stamping process.

  • PDF

Syntheses of Idarubicin Analogues Containing a Glucose or Galactose Moiety as a Glycone

  • Rho, Young-S.;Park, Ran;Kim, Seon-Young;Yoo, Dong-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.1
    • /
    • pp.69-74
    • /
    • 2010
  • The new idarubicin analogues (12 and 13) with a glucose or galactoseas as a glycone were synthesized from daunomycin (2). (+)-4-Demethoxydaunomycinone (6) obtained from reaction of 2 with $AlCl_3$ was converted to 4-trifluoromethanesulfonyl daunomycinone (7) through reaction with trifluoromethanesulfonic anhydride. The treatment of 7 with 1,1-bis-(diphenylphospino)ferrocene/$Pd(OAc)_2$ in triethylamine/formic acid/dioxane provided the idarubicinone (5b). Glycosylation of 7-hydroxy group of 5b with two kinds of tetraacetyl pyranosyl halide (8 and 9) by a modified Koenigs-Knorr procedure and then deacetylation using aqueous 0.1 N LiOH solution and amberlite cationic resin gave the objective materials. The in vitro MTT assay of the analogues (12b and 13a) in comparison with idarubicin (5a) on peripheral blood human promyelocytic-leukemia cell line and human breast cancer cell line were also described.

HI 21 CM EMISSION LINE STUDY OF SOUTHERN GALACTIC SUPERNOVA REMNANTS

  • KOO BON-CHUL;KANG JI-HYUN;MCCLURE-GRIFFITHS N. M.
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.61-77
    • /
    • 2004
  • We have searched for HI 21 cm line emission from shocked atomic gas associated with southern supernova remnants (SNRs) using data from the Southern Galactic Plane Survey. Among the 97 sources studied, we have detected 10 SNRs with high-velocity HI emission confined to the SNR. The large velocity and the spatial confinement suggest that the emission is likely from the gas accelerated by the SN blast wave. We also detected 22 SNRs which show HI emission significantly brighter than the surrounding regions over a wide ($>10 km\;s^{-1}$) velocity interval. The association with these SNRs is less certain. We present the parameters and maps of the excess emission in these SNRs. We discuss in some detail the ten individual SNRs with associated high-velocity HI emission.

A Study on Ground Fault Detecting System for DC Voltage Line in the Electric Power Plant (발전소 직류전압 전선로 접지검출시스템에 관한 연구)

  • Lee, H.K.;Kim, N.H.;Park, C.H.;Kim, T.S.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.754-757
    • /
    • 1995
  • This system can detect a ground fault point or a bad insulated line by measuring a power plant DC feeder insulation resistance at the uninterruptible power status. And when the power plant DC feeder with low frequency AC signal has a ground fault, this measuring system can keep recording of its ground fault current and phase checked by Z.C.T. Therefore the power plant could protect a unexpected service interruption.

  • PDF