• Title/Summary/Keyword: S-N곡선

Search Result 324, Processing Time 0.031 seconds

Development of Vortex Scrubber Using Electrolyzed Water for the Removal Efficiency Improvement of Minute Particles and Odor (미세분진 및 냄새제거 효율향상을 위한 선회류식 세정전해 기술개발)

  • Kim, Nor-Jung;Lim, Seong-Il;Kim, Sun-Mi;Kim, Sun-Uk;Kim, Lae-Hyun;Kim, Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.3
    • /
    • pp.1-7
    • /
    • 2010
  • According to Indoor Air Quality(IAQ) management law for multi-use buildings, SEEONE CO., Ltd. made pilot and tested it to remove minute particle, odor, VOCs, etc. within the standards of IAQ. This pilot made by SEEONE CO., Ltd. is vortex scrubber washing electrolyzed water. As 30 minutes test result in multi-use building indoor place, minute particle(the smoke of a cigarette) was reduced $920{\mu}g/m^3{\rightarrow}112{\mu}g/m^3$, gaseous contaminants was reduced Formaldehyde (HCHO) 20ppm$\rightarrow$4ppm, Ammonia($NH_3$) 50ppm$\rightarrow$1ppm, Trimethylamine ($(CH_3CH_2)_3N$) 15ppm$\rightarrow$trace, Methylethylketone($CH_3COC_2H_5$) 25ppm$\rightarrow$trace, Acetic acid ($CH_3COOH$) 20ppm$\rightarrow$trace, Acetaldehyde($CH_3CHO$) 15ppm$\rightarrow$2ppm and Acetone($CH_3COCH_3$) 50ppm$\rightarrow$N.D. The pilot test result of the air filter using electroyzed water in vortex scrubber showed high removal efficiency. Because purified air maintain indoor humidity of approximately 40~60%, so users can feel pleasant. In E.coli, S.aureus sterilization test and CODcr, turbidity treatment test by electrolysis, germs was sterilized over 99.99% and CODcr and turbidity was decreased gradually. So water used for washing can be reused by electrolysis.

Simultaneous Determination of Berberine, Cinnamic Acid and Glycyrrhizin in Pharmaceutical Formulations by Capillary Electrophoresis with Diode-Array Detection (모세관 전기이동법에 의한 생약제제중 베르베린, 계피산 및 글리시리진의 동시 정량)

  • Kang, Seong Ho;Chung, Wha Jin;Yoon, Hyung Jung;Chung, Doo Soo
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.2
    • /
    • pp.98-104
    • /
    • 1997
  • A simple, accurate and reproducible capillary electrophoresis(CE) assay has been developed for the determination of berberine, cinnamic acid, and glycyrrhizin which are used in traditional Korean medicinal preparations. Separation of these compounds was performed in 20 mM phosphate buffer(pH 7.5) and acetonitrile(75:25, v/v) using a bare fused silica capillary($57 cm{\times}75 {\mu}m$ i.d.) at 25$^{\circ}C$. With the electric field of 350 V/cm, the time needed for the separation of berberine, cinnamic acid and glycyrrhizin was within 13 min. Calibration curves were linear for 1∼100 ${\mu}g/mL$ berberine, 0.3∼100 ${\mu}g/mL$ cinnamic acid and 2.5∼100 ${\mu}g/mL$ glycyrrhizin. The ranges of relative standard deviations(n=5) for those samples were between 0.96∼2.35%. The limits of detection(S/N=3) for berberine, cinnamic acid and glycyrrhizin were 0.5, 0.1 and 2.0 ${\mu}g/mL$, respectively. The numbers of theoretical plates were 181,000(berberine), 88,000(cinnamic acid) and 169,000(glycyrrhizin), while they were 3,100∼4,800 in HPLC.

  • PDF

17 beta-Estradiol Increases Peak of $\textrm{Ca}^{2+}$ Current in Mouse Early Embryo (에스트로겐이 생쥐 초기배의 $\textrm{Ca}^{2+}$ 전류에 미치는 영향)

  • 강다원;신용원;김은심;홍성근;한재희
    • Journal of Embryo Transfer
    • /
    • v.16 no.2
    • /
    • pp.79-89
    • /
    • 2001
  • Steroid hormones control the expression of many cellular regulators, and a role thor estrogen in mouse oocytes has been well documented. The preovulatory $E_2$increment is generally accepted as the endocrine process regulating induction of in vivo oocyte maturation To address whether the activity of the T-type $Ca^{2+}$ channel is altered by 17 beta-estradiol ( $E_2$), we examined the actions of $E_2$on the calcium channel of mouse oocytes and early embryos. Oocrtes were collected from the oviduct of mice treated with pregnant mare's serum gonadotropin (PMSG) and human choronic gonadotropin (hCG). Whole cell voltage clamp technique and confocal microscopy were used to examine that $E_2$increase intracellular $Ca^{2+}$ concentration ([C $a^{2+}$]$_{i}$ ) via voltage dependent $Ca^{2+}$ channel (VDC) and estrogen receptor (FSR), and $E_2$concentration by the use of radioimmunoassay (RIA) were examined in mouse. The results obtained were as follows: The peak of $Ca^{2+}$ current induced by $E_2$increased 122% to 1.50$\pm$0.03 nA from 1.23$\pm$0.21 nA (n=15) in the presence of 5 mM extracellular $Ca^{2+}$ concentration ([C $a^{2+}$]$_{o}$ ). The increased $Ca^{2+}$ current was temporally associated with $Ca^{2+}$ transients. The intracellular $Ca^{2+}$ level increased 207%~30 s following the addition of 1${\mu}{\textrm}{m}$ $E_2$(relative fluorescence intensity: 836.4$\pm$131.2 for control, n=10, 1736.4$\pm$192.0 in the presence of $E_2$, n=10). $E_2$increased amplitude of $Ca^{2+}$ current and [C $a^{2+}$]$_{i}$ . $E_2$-induced $Ca^{2+}$ current and $E_2$concentration in blood were showed difference on the stage of embryo. These results suggest that $E_2$modulate $Ca^{2+}$ channel to increase $Ca^{2+}$ influx.$Ca^{2+}$ influx.

  • PDF

Role of $Ca^{2+}$ for Inactivation of N-type Calcium Current in Rat Sympathetic Neurons (흰쥐 교감신경 뉴론 N형 칼슘전류의 비활성화에 미치는 칼슘효과)

  • Goo, Yong-Sook;Keith S. Elmslie
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.54-67
    • /
    • 2003
  • The voltage-dependence of N-type calcium current inactivation is U-shaped with the degree of inactivation roughly mirroring inward current. This voltage-dependence has been reported to result from a purely voltage-dependent mechanism. However, $Ca^{2+}$-dependent inactivation of N-channels has also been reported. We have investigated the role of $Ca^{2+}$ in N-channel inactivation by comparing the effects of $Ba^{2+}$and $Ca^{2+}$ on whole-cell N-current in rat superior cervical ganglion neurons. For individual cells in-activation was always larger in $Ca^{2+}$ than in $Ba^{2+}$ even when internal EGTA (11 mM) was replaced with BAPTA (20 mM). The inactivation vs. voltage relationship was U-shaped in both divalent cations. The enhancement of inactivation by $Ca^{2+}$ was inversely related with the magnitude of inactivation in $Ba^{2+}$ as if the mechanisms of inactivation were the same in both $Ba^{2+}$ and $Ca^{2+}$. In support of this idea we could separate fast ( ${\gamma}$ ~150 ms) and slow ( ${\gamma}$ ~ 2500 ms) components of inactivation in both $Ba^{2+}$and $Ca^{2+}$ using 5 sec voltage steps. Differential effects were observed on each component with $Ca^{2+}$ enhancing the magnitude of the fast component and the speed of the slow component. The larger amplitude of fast component indicates that the more channels inactivate via this pathway with $Ca^{2+}$ than with $Ba^{2+}$, but the stable time constants support the idea the fast inactivation mechanism is identical in $Ba^{2+}$and $Ca^{2+}$. The results do not support a $Ca^{2+}$-dependent mechanism for fast inactivation. However, the $Ca^{2+}$-induced acceleration of the slowly inactivating component could result from a $Ca^{2+}$-dependent process.

  • PDF

Effect of tannin contents on the physicochemical characteristics of acorn starch (탄닌함량에 따른 도토리전분의 물리화학적 특성)

  • Ahn, Ho-Kyoung;Choi, Hyeong-Taeg;Kim, Byong-Lyoung;Oh, Doo-Hwan
    • Applied Biological Chemistry
    • /
    • v.33 no.4
    • /
    • pp.301-306
    • /
    • 1990
  • The Physical and chemical properties or dry acorn starch(DS), detannined acorn starch (DTS) and defatted and detannined acorn starch(Drn) were investigated. Ail acorn starch sample, observed by a scanning electron microscope, showed a hemispherical shape ud its size was about $5{\sim}10{\mu}m$ in diameter. It had a little change on the pasting temperature of DS, DTS and DFTS but peak viscosity of DTS was somewhat higher than that of n. Flow behavior of gelatinized starch pastes showed a pseudoplastic behavior and flow behavior index was lower than unit. The consistency coefficient showed concentraion and temperature dependency. The activation energies of DS, DTS and DFTS were $2.09{\sim}3.58Kcal/g\;{\cdot}\;mol and time dependent characteristic of acorn starch samples showed thixotrpic behavior.

  • PDF

The Development and It′s Characteristics of New Film Dosimetry Algorithm for Personal Dosimetry (개인피폭 선량 측정을 위한 필름 배지 선량계의 새로운 알고리즘 개발 및 특성)

  • 이병용;장혜숙;봉정균;권수일
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.35-40
    • /
    • 1995
  • Purpose: We have developed new film dosimetry algorithm for personal dosimetry and examined its characteristics. Materials and methods: Agfagaevart personal monitoring 2/10 films are used. Films which are in the film badges filtered with Cu 0.3mm, plastic 1.5mm, Aluminum 0.6mm and tin 0.8mm, were exposed by standard dosimetry laboratory. Irradiated energy categories are ANSI N13.1l Category III, and IV. Manual type film precessor and X-rite film densitometor was used. Filtered densities to energy relations and does to transformed densities relations can be obtained ofter transformation of H&D curves to linear shape by polynomal fitting. Reults : Personal dose be determined within 25% error for category m and 15% for category IV. And we are able to evaluate the exposed energy. Conclusion : New algorithm developed in this study is good for personal dosimetry within 30% error range for catergory III and IV. It is expectd to be complete personal dosimetry algorithm with further study for categrory, I, Dand II V.

  • PDF

Air-tightness Evaluation of Tube Structures for Super-speed Tube Railway Systems: II. System Test and Parametric Analysis (초고속 열차 시스템을 위한 튜브 구조물의 기밀성 평가 : II. 시스템 실험 및 파라메터 해석)

  • Park, Joo-Nam;Kim, Lee-Hyeon;Nam, Seong-Won
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.2
    • /
    • pp.151-159
    • /
    • 2011
  • This study performed an experimental study for air-tightness performance evaluation of concrete tube structures with joints. The test specimens consist of a continuous concrete tube, a concrete tube with a joint in the middle, and a segmented concrete tube. The test is performed in such a way that the inner pressure of the tube is dropped down to 0.1atm and the increase of the pressure is monitored with time. An equivalent air permeability is then calculated based on the test results. The results show that, as expected, a structure with more joints or bonds tends to be less air-tight. A sensitivity study shows that the system air-tightness performance level becomes higher as either the diameter or the thickness of the tube increases. Moreover, the increase in the diameter or the thickness of the tube makes an effort to enhance the air-tightness more effective.

Security Analysis against RVA-based DPA Countermeasure Applied to $Eta_T$ Pairing Algorithm (RVA 기반의 페어링 부채널 대응법에 대한 안전성 분석)

  • Seo, Seog-Chung;Han, Dong-Guk;Hong, Seok-Hie
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.21 no.2
    • /
    • pp.83-90
    • /
    • 2011
  • Recently, pairings over elliptic curve have been applied for various ID-based encryption/signature/authentication/key agreement schemes. For efficiency, the $Eta_T$ pairings over GF($P^n$) (P = 2, 3) were invented, however, they are vulnerable to side channel attacks such as DPA because of their symmetric computation structure compared to other pairings such as Tate, Ate pairings. Several countermeasures have been proposed to prevent side channel attacks. Especially, Masaaki Shirase's method is very efficient with regard to computational efficiency, however, it has security flaws. This paper examines closely the security flaws of RVA-based countermeasure on $Eta_T$ Pairing algorithm from the implementation point of view.

Characteristics Analysis of SiPM for Detection of High Sensitivity of Portable Detectors (휴대용 검출기의 방사선 고감도 검출을 위한 SiPM 특성 분석)

  • Byung-Wuk Kang;Sun-Kook Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.897-902
    • /
    • 2023
  • The purpose of this paper is to analyze the characteristics of Silicon Photomultiplier (SiPM) for the realization of high-sensitivity radiation detection in portable detectors. Portable X-ray detectors offer the advantage of quickly accessing the patient's location and obtaining real-time images, allowing physicians to perform rapid diagnoses. However, this mobility comes with challenges in achieving accurate radiation detection. In existing detectors, SiPM is used for a simple purpose of detecting X-ray triggers. To verify the feasibility of high-sensitivity X-ray detection through SiPM, seven types of SiPM sensors were compared and selected, and their characteristics were analyzed. The SiPM used in the final test demonstrated the ability to distinguish signals at the ultra-low radiation level of 10 nGy, and it was observed that the slope of the signal rise curve varies with the X-ray tube voltage. Utilizing the characteristics of SiPM, which exhibits changes in signal level and duration with X-ray dose, it appears possible to achieve high-sensitivity measurements for X-ray detection.

Laparoscopic Assisted Total Gastrectomy (LATG) with Extracorporeal Anastomosis and using Circular Stapler for Middle or Upper Early Gastric Carcinoma: Reviews of Single Surgeon's Experience of 48 Consecutive Patients (원형 자동문합기를 이용한 체외문합을 시행한 복강경 보조 위전절제술: 한 술자에 의한 연속적인 48명 환자의 수술성적분석)

  • Cheong, Oh;Kim, Byung-Sik;Yook, Jeong-Hwan;Oh, Sung-Tae;Lim, Jeong-Taek;Kim, Kab-Jung;Choi, Ji-Eun;Park, Gun-Chun
    • Journal of Gastric Cancer
    • /
    • v.8 no.1
    • /
    • pp.27-34
    • /
    • 2008
  • Purpose: Many recent studies have reported on the feasibility and usefulness of laparoscopy assisted distal gastrectomy (LADG) for treating early gastric cancer. On the other hand, there has been few reports about laparoscopy assisted total gastrectomy (LATG) because upper located gastric cancer is relatively rare and the surgical technique is more difficult than that for LADG, We now present our procedure and results of performing LATG for the gastric cancer located in the upper or middle portion of the stomach. Materials and Methods: From Jan 2005 to Sep 2007, 96 patients underwent LATG by four surgeons at the Asan Medical Center, Seoul, Korea. Among them, 48 consecutive patients who were operated on by asingle surgeon were analyzed with respect to the clinicopathological features, the surgical results and the postoperative courses with using the prospectively collected laparoscopy surgery data. Results: There was no conversion to open surgery during LATG. For all the reconstructions, Roux-en Y esophago-jejunostomy and D1+beta lymphadenectomy were the standard procedures. The mean operation time was $212{\pm}67$ minutes. The mean total number of retrieved lymph nodes was $28.9{\pm}10.54$ (range: $12{\sim}64$) and all the patients had a clear proximal resection margin in their final pathologic reports. The mean time to passing gas, first oral feeding and discharge from the hospital was 2.98, 3.67 and 7.08 days, respectively. There were 5 surgical complications and 2 non-surgical complications for 5 (10.4%) patients, and there was no mortality. None of the patients needed operation because of complications and they recovered with conservative treatments. The mean operation time remained constant after 20 cases and so a learning curve was present. The morbidity rate was not different between the two periods, but the postoperative course was significantly better after the learning curve. Analysis of the factors contributing to the postoperative morbidity, with using logistic regression analysis, showed that the 8MI is the only contributing factor forpostoperative complications (P=0.029, HR=2.513, 95% CI=1.097-5.755). Conclusions: LATG with regional lymph node dissection for upper and middle early gastric cancer is considered to be a safe, feasible method that showed an excellent postoperative course and acceptable morbidity. BMI should be considered in the patient selection at the beginning period because of the impact of the BMI on the postoperative morbidity.

  • PDF