• Title/Summary/Keyword: S-Duct

Search Result 603, Processing Time 0.035 seconds

A Study on the Transmitted Noise Characteristics through the Ventilating Duct (환기용 덕트내의 전달소음 특성에 관한 연구)

  • Choi, Han-Lim;Kim, Kyung-Whan;Choi, Ho-Seon;Oh, Sai-Kee;Chung, Baek-Young
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.376-380
    • /
    • 2009
  • The transmission noise characteristics through the ventilating duct was conducted numerically using SYSNOISE. A ventilating system is usually composed of mufflers for preventing noise transmission from the ventilator into indoors through the ducts and distributors for transferring air to or from each room. The transmitted noise characteristics of distributors which have different branch angles and of mufflers having different shapes were analyzed numerically. New duct element combining a muffler and a T-shaped distributor was developed for better noise reduction in this paper. New element's performance was shown numerically.

  • PDF

Identification of Root Age by Histochemical Staining of Secretory Duct Layers in Ginseng (인삼 분비도관의 조직화학적 염색에 의한 연근판별)

  • 이경환;이성식;이명구;김은수
    • Journal of Ginseng Research
    • /
    • v.25 no.2
    • /
    • pp.101-105
    • /
    • 2001
  • Identification of the age of ginseng root is very important in commercial market as well as in research field. However, any criterion abut it has not been clearly established yet. We studied to find a clear morphological key for identification of ginseng root\\`s age using the histochemical staining method. Fresh sections of 3, 4, 5, and 6 year old roots were stained with 1% nile blue, observed under the light microscopy, and compared each other. The number of secretory duct layers(SDL) is a useful key to confirm the age of ginseng root as follow; three-year-old root has two, four-year-old one has three, fie-year-old one has four, and six-year-old one has five resin duct layers on each cortical region of roots. Secretory ducts are thought to be formed by the vascular cambium every year. Unlike the surrounding parenchyma cells, secretory epithelial cells lack starch grains in the cytoplasm.

  • PDF

Development of Cabin Noise Prediction Program Induced by HVAC System (공조시스템 유기 격실 소음 예측 프로그램 개발)

  • Kim, Byung-Hee;Kwon, Jong-Hyun;Cho, Dae-Seung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.554-558
    • /
    • 2004
  • In this paper, we introduce noise prediction program of HVAC system to assist low-noisy design of ship's cabin. The developed program calculates sound power levels at HVAC components considering primary and secondary noise generated by fan and duct element, duct element noise attenuation, and duct break-in noise based on the authentic empirical method suggested by NEBB and acoustic power balancing method. Sound pressure level at cabin with or without ceiling system is evaluated by the diffuse-field theory considering diffuser and duct break-out sound powers. Moreover, the program provides intuitive pre- and post-processors using modem GUI functions to help efficient modeling and evaluation of cabin and HVAC component noise. To validate the accuracy and convenience of the program, noise prediction for a HVAC system is demonstrated.

  • PDF

A Giant Sialolith in a Wharton's Duct: Report of Two Cases (악하선관에 발생한 거대 타석증의 치험 2례)

  • Na, Hye-Jung;Yoon, Kyu-Ho;Cheong, Jeong-Kwon;Bae, Jung-Ho;Kim, Hae-Lin;Jo, Kyu-Hong;Shin, Jae-Myung;Baik, Jee-Seon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.4
    • /
    • pp.363-367
    • /
    • 2010
  • Sialolithiasis is the most commom disease of salivary gland. The main symptoms are pain and swelling of the involved gland during eating. It can occur at any age but patients in their third to fifth decade present most cases. Males are more frequently affected than females. Most sialoliths are located within the duct system of the submandibular gland. Submandibular sialoliths close to the hilum of the gland tend to become large and ovoid shape, whereas sialoliths in the duct tend to be elongated. Commonly, sialoliths measure from 1 mm to less than 10 mm, and larger than 15 mm are considered rare. In one case we have removed a giant sialolith which was located in a wharton's duct and in the other case we have removed multiple sialolith including a giant sialolith which were also located in a Wharton's duct. We report these 2 cases with literature reviews.

Identification of parasite DNA in common bile duct stones by PCR and DNA sequencing

  • Jang, Ji-Sun;Kim, Kyung-Ho;Yu, Jae-Ran;Lee, Soo-Ung
    • Parasites, Hosts and Diseases
    • /
    • v.45 no.4
    • /
    • pp.301-306
    • /
    • 2007
  • We attempted to identify parasite DNA in the biliary stones of humans via PCR and DNA sequencing. Genomic DNA was isolated from each of 15 common bile duct (CBD) stones and 5 gallbladder (GB) stones. The patients who had the CBD stones suffered from cholangitis, and the patients with GB stones showed acute cholecystitis, respectively. The 28S and 18S rDNA genes were amplified successfully from 3 and/or 1 common bile duct stone samples, and then cloned and sequenced. The 28S and 18S rDNA sequences were highly conserved among isolates. Identity of the obtained 28S D1 rDNA with that of Clonorchis sinensis was higher than 97.6%, and identity of the 18S rDNA with that of other Ascarididae was 97.9%. Almost no intra-specific variations were detected in the 28S and 18S rDNA with the exception of a few nucleotide variations, i.e., substitution and deletion. These findings suggest that C. sinensis and Ascaris lumbricoides may be related with the biliary stoneformation and development.

Duct Effects on rotor noise in radiation (덕트가 로터 소음 방사에 미치는 영향)

  • Choi, Han-Lim;Chung, Ki-Hoon;Lee, Duck-Joo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.938-941
    • /
    • 2004
  • Sound generation and radiation from the duct-rotor system are calculated numerically. The wake geometries of a two-bladed rotor are calculated by using a time-marching fiee-wake method without a non-physical model of the far wake. Acoustic free field due to a rotating rotor is obtained by Lowson's equation. Using Kirchhoff source, rotating sources are modeled as stationary ones and can be inserted in the thin body boundary element method. The Kirchhoff source is validated through calculation of acoustic pressure due to a rotating point force. The thin body boundary element method (thin body BEM) is validated through calculation of acoustic radiation of ducted dipole. Using Kirchhoff source and thin body BEM, acoustic radiation of a ducted rotating source is calculated. Acoustic shielding is observed by inserting a duct and shows different phenomena at each major frequency. Acoustic radiation of a real duct-rotor system is also calculated using this method and the ducted acoustic field is significantly different from rotor only.

  • PDF

A Study on the Vertical Flue Duct for Application of Small Wind Power System in High-Rise Apartments (초고층 공동주택의 소형풍력발전시스템 적용을 위한 수직연도 활용에 관한 연구)

  • Kim, Seong-Yong;Lee, Yong-Ho;Park, Jin-Chul;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.116-125
    • /
    • 2011
  • This study examined vertical shafts in high-rise apartments of the old high-rise buildings, reviewed the possibility of using flue ducts, and analyzed airflow patterns according to pressure differences between in and out side of flue ducts through computational fluid dynamics(CFD). The resulting conclusions are as follows: 1) The analysis results of airflow according to the stack effect of flue ducts show that smaller-diameter flue ducts(${\phi}1.2m$) would be morefavorable in increasing downward wind velocity than bigger-diameter ones(${\phi}1.6m$) and that the introduction ducts for outside air should be more than 50% of flue duct diameter to obtain a downward wind velocity higher than $3.0^m/s$ that is the minimum blade wind velocity of a small domestic wind generator. 2) The optimal installation location of a bypass introduction duct is the neutral plane of a flue duct or lower. When the diameter of the upper duct is bigger than that of the lower duct, it will generate more effects on the increase of downward wind velocity in flue ducts.

Active Noise Control of Short Duct using Zero Acoustic Impedance Boundary (음향 임피던스 0의 경계면에 의한 짧은 덕트의 능동소음제어)

  • Cha, Kyung-Hwan;Lee, Chai-Bong;Kim, Chun-Duck
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.101-105
    • /
    • 1997
  • The active noise control method that was developed for long duct has some problems to be applied for short duct. To overcome this problem, we apply the SISO(Single Input Single Output) algorithm for the active noise control of short duct using zero acoustic impedance boundary. The SISO algorithm can input noise signal and error signal with one microphone simultaneously. The real-time controller was implemented using TMS320E25 DSP(Digital Signal Processing) chip and it's performance was evaluated by experiment. As a result, we obtain total 4.7dBA noise reduction for 0.80m short duct.

  • PDF