• Title/Summary/Keyword: S-Band

Search Result 4,784, Processing Time 0.03 seconds

FREQUENCY OF GIEMSA C-BAND CHROMOSOMES IN THREE INBRED LINES OF CHICKENS

  • Yeo, J.S.;Shoffner, R.N.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.2 no.1
    • /
    • pp.35-38
    • /
    • 1989
  • Giemsa C-banded mitotic chromosome prepatations from White Leghorn, New Hampshire and Rhode Island Red inbred lines were compared for frequency of C-band regions on individual chromosomes. Except for autosomes 3, 6, 8 and 9 and W sex chromosomes, C-banding was extremely variable in other macrochromosomes. No divergence for C-band difference between homologous chromosomes of these lines was detected. Approximately 75% of the mitotic metaphase microchromosomes have recognizable C-band regions with the current technique.

A study on the Formation of Adiabatic Shear Band of Tungsten Heavy Alloys (텅스텐 중합금의 단열전단밴드 형성 연구)

  • 이승우;문갑태;홍성인
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2002.05a
    • /
    • pp.187-190
    • /
    • 2002
  • To study adiabatic shear band formation of tungsten heavy alloys, 5 prismatic specimens are loaded by high velocity impacts and treated as plane strain problems. Their volume percent of tungsten particles in WHA are 81%, 93% and 97% respectively and for the fixed 81% volume percent, small size particle model, large size particle model, undulated particle models are considered and then, the effects of particle's volume ratio, geometry and size to the formation of shear band are discussed.

  • PDF

The Comparison of Protein Patterns of Several Species in Bivalvia by SDS Polyacrylamide Gel Electrophoresis (SDS Polyacrylamide Gel 電氣泳動에 依한 斧足綱數種의 蛋白質패턴의 比較)

  • Park, Won-Chul;Ha, Man-Joon
    • The Korean Journal of Zoology
    • /
    • v.28 no.2
    • /
    • pp.61-70
    • /
    • 1985
  • SDS-polyacrylamide gel electrophoresis for the proteins obtained from the plasma, Scapharca subcrenata and suapharca broughtonii, and for the proteins of muscles of several species in Bivalvia was performed. The protein patterns of plasma showed little difference between S. subcrenata and S. broughtonii in lower molecular weight weight proteins. However, the protein patterns of muscles of other species, which wre used in this study, were more shown in the lower molecular weights than the higher molecular weights in difference. Thus it is thought be an interesting fact. The protein band of blood corpuscles, 17,800 dalton, was not appeared in S. broughtonii, but this band was appeared in S. subcrenata. Henceforth this is the significantly important difference in these two species. But the protein patterns obtained from muscles of the species did not show a difference in a range of molecular weights between 10,000 and 100,000 daltons. Meanwhile, several protein bands obtained from Meretrix lusoria were similar to those of Mercenaria stimpsona. Hence, in this study, 6 protein bands which exist all species in Bivalvia and 4 characteristic protein bands in S. subcrenata and S. broughtoniionly, were investigated. And in four species of Eulamellibranchia, two protein bands in comon and the characteristic band of 23,000 dalton which is belong to Meretrix lusoria and Mercenaria stimdsona, were found. The molecular weights of the characteristic protein patterns, which are contained in each species, were measured and compared.

  • PDF

A Study on the Analysis of Visibility between a Lunar Orbiter and Ground Stations for Trans-Lunar Trajectory and Mission Orbit (지구-달 전이궤적 및 임무 궤도에서 궤도선과 지상국의 가시성 분석에 관한 연구)

  • Choi, Su-Jin;Kim, In-Kyu;Moon, Sang-Man;Kim, Changkyoon;Rew, Dong-young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.3
    • /
    • pp.218-227
    • /
    • 2016
  • Korean government plans to launch a lunar orbiter and a lander to the Moon by 2020. Before launch these two proves, an experimental lunar orbiter will be launched by 2018 to obtain key space technologies for the lunar exploration. Several payloads equipped in experimental lunar orbiter will monitor the surface of the Moon and will gather science data. Lunar orbiter sends telemetry and receives tele-command from ground using S-band while science data is sent to ground stations using X-band when the visibility is available. Korean deep space network will be mainly used for S and X-band communication with lunar orbiter. Deep Space Network or Universal Space Network can also be used for the S-band during trans-lunar phase when korean deep space network is not available and will be used for the S-band in normal mission orbit as a backup. This paper analyzes a visibility condition based on the combination of various ground antennas and its mask angles according to mission scenario to predict the number of contacts per day and to build an operational scenario for the lunar orbiter.

Ka-band Satellite Broadcasting System using Scalable Video technology

  • Kim, Seung-Chul;Chang, Dae-Ig
    • Journal of Satellite, Information and Communications
    • /
    • v.2 no.2
    • /
    • pp.59-63
    • /
    • 2007
  • In this paper, we propose an advanced Ka-band satellite HD broadcasting system using scalable video coding technology. As already known, it is not so easy to achieve reasonable link availability on Ka-band because of the rain-attenuation effect, and in case of HD broadcasting service it's more difficult. To overcome that problem, we propose an hierarchical broadcasting system based on H.264 SVC technology. In this paper, we suggest a few types of system scenario to realize the concept. Those scenarios are including DVB-S and DVB-S2 and spatially scalable video stream is the source stream in all cases.

  • PDF

A clinical Study of Vitelline Duct and Vessel Remnants (제장간막관 및 혈관 잔류이상에 대한 임상적 고찰)

  • Choi, Jae-Young;Jung, Poong-Man
    • Advances in pediatric surgery
    • /
    • v.4 no.1
    • /
    • pp.27-33
    • /
    • 1998
  • Of 72 patients with vitelline duct and vessel remnants, 45 (62.5 %) had symptomatic lesions. The mean age of the patients was 27.9 months. Males predominated (4.6 : 1). There were 22 cases of Meckel's diverticulum, 6 of Meckel's diverticulum attatched to the umbilicus with a fibrous band, 6 cases of patent vitelline duct, 5 cases of vitelline artery remnants as a fibrous band and 2 cases each of umbilical sinus and polyp, and vitelline cyst. Twenty-three patients (51 %) presented with intestinal obstruction, 6(13 %) with rectal bleeding, 4(9 %) with perforated Meckel's diverticulum, 5 with intestinal juice drainage through umbilicus, 5 with umbilical lesions, 1 with abdominal mass, and 1 with sepsis. Intestinal obstruction due to fibrous band developed during infancy(average age; 4.6 months). Seventeen asymptomatic Meckel's diverticulum, 8 obliterated vitelline artery remnants and 1 vitelline vein remnant as fibrous band, and 1 vitelline cyst were found incidentally at laparotomy. About 82 % of the complicated Meckel's diverticulum presented in infants and children less than 4 years of age.

  • PDF

Ultra-broadband Optical Amplifier for WDM Optical Transmission Networks (파장분할다중 방식 광전송망을 위한 초광대역 광증폭기)

  • Lee, Young-Sun;Jung, Jae-Jin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.4
    • /
    • pp.289-294
    • /
    • 2008
  • Affordable traffic capacity of each node in networks is expected to reach in Tb/s range in proportion to the rapid growth of Internet users. To transmit more than Tb/s per fiber pair, WDM should be used as well as existing TDM. To increase the capacity of transmission in WDM networks, there are two ways, increasing channel speed or channel quantity. To increase the channel quantity, there are two ways, narrow spacing or expanding transmission bandwidth. To expand bandwidth, ultra-broadband optical amplifier technology is necessary. In this paper, we introduce EDFA in effect at C/L band, FRA, and some optical amplifiers in effect at S band, and analyze the development trend of various amplification technologies.

  • PDF

Design of Multi-Band Internal Antenna for Handset Applications Including Media-FLO Band (미디어플로대역을 포함하는 단말기용 다중 대역 내장형 안테나의 설계)

  • Lee, Hyun-Kyu;Lee, Byung-Je
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.3
    • /
    • pp.48-55
    • /
    • 2008
  • This paper presents a design of a multi-band infernal antenna for mobile handsets which can cover the major mobile services such as WiBro/WiMAX mobile internet services and Media-FLO/S-DMB services. Using wideband monopole antenna structure, the proposed antenna obtains the wide bandwidth characteristic at high Sequency band to be applicable for new mobile services. Stacking meandered radiator on the wideband monopole radiator and obtaining the different current path and lenga on these stacked radiators, overall antenna volume is effectively reduced. The measured bandwidths (VSWR<3) of the proposed antenna is 270 MHz and 2032 MHz at low and high band, respectively. This antenna can effectively covers major wireless communication bands including Media-FLO, CDMA, GSM, GPS, DCS, PCS, UMTS, WiBro, WiMAX, and S-DMB.

  • PDF

40channel Arrayed Waveguide Grating with O.75delta% Refractive Index (0.75Δ% 굴절율차를 가진 40채널 광파장 다중화 및 역다중화 소자 제작 및 특성)

  • Moon, H.M.;Choi, G.S.;Lee, K.H.;Kim, D.H.;Lee, J.H.;Lee, D.H.;Oh, J.K;Kwak, S.C.;Kwon, O.K.;Kang, D.S.;Choi, J.S.;Jong, G;Lee, H.Y.
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.3
    • /
    • pp.196-200
    • /
    • 2005
  • A 40 channel arrayed-waveguide grating (AWG) filter operating in C-band and L-band wavelength regions has been fabricated using PLC (Planar Lightwave Circuit) processes with 0.75 refractive index difference. Its design was optimized for matching the center wavelength with the ITU-recommended wavelength. The characteristics of the fabricated C-band AWG are as follows; average insertion loss < 2.5 dB, polarization-dependent loss < 0.3 dB, non-adjacent crosstalk >35dB, and the loss uniformity of 0.8 dB. In the L-band AWG, wavelength accuracy is below 0.02nm.

A Study on the Effect of Time Lapse After Position Change and Abdominal Band on Pulmonary Function in the Cervical Cord Injuries (척수손상 환자의 자세 변화 후 시간경과와 복대사용이 폐기능에 미치는 영향)

  • Lee, Jae-Ho;Park, Chang-Il;Chon, Joong-Sun
    • Physical Therapy Korea
    • /
    • v.4 no.3
    • /
    • pp.17-33
    • /
    • 1997
  • The objective of this study was to identify pulmonary functional variations in relation to postural changes, lapse after changing position, and the use of abdominal band in the cervical cord injured. The subjects of this study were 19 quadriplegic patients who had been admitted to the department of the Rehabilitation Hospital, College of Medicine, Yousei University, from April, 1997 through May 3, 1997. A spiroanalyzer was used to measure pulmonary function in supine, standing, time after changing position, and recording to the position, application method, and tightness of the abdominal band. The data were analyzed by the repeated measure one-way ANOVA, and Wilcoxon signed rank test. The findings were as follows: 1. All phase of the patients' pulmonary function improved significantly in supine posture in contrast to standing (vital capacity by $0.46{\ell}$ and expiratory reserve volume by $0.09{\ell}$). 2. The longer the time lapsed from supine posture to standing, the patient's expiratory reserve volume, maximum ventilation volume, vital capacity, and forced expiratory volume increased. 3. When the patient lay in supine position, the maximum ventilation volume, vital capacity, and the forced vital capacity increased then the center line of the abdominal band was placed along iliac crest; on the other hand, when the patient was standing, placing the bottom line of the abdominal band along iliac crest increased the maximum ventilation volume, vital capacity, and forced expiratory volume. 4. In placing the abdominal band in the patients, leaving space between the top and bottom lines of the band helped increased in maximum ventilation volume, vital capacity, and forced vital capacity for patient in supine as well as in standing. 5. When placing the abdominal band to patients in supine posture, reducing the length of the band by 2.5% along the patient's waist line increased the patients' vital capacity, while reducing the length by 10% to patients in standing increased the maximum ventilation volume. The abdominal band should be placed in such a way that the bottom part of the band should be more tightly fastened while leaving enough room for a hand to be placed in between the body and the band for the top part of the hand. It should also be noted that in a supine position, the bottom line of the band should be placed along the iliac crest, while in standing, the center line should be placed along the iliac crest. The length of the band should also be reduced by 2.5% of the waist line in supine position, and in standing, the length should be reduced by 10%. It should also be noted that the pulmonary function of the patients should be measured at least 10 minutes after one position change.

  • PDF