• Title/Summary/Keyword: S/R Valve

Search Result 123, Processing Time 0.025 seconds

Developing Analysis Model of Hydraulic System for Dental Chair (치과용 유니트체어 유압구동 시스템 해석모델 개발)

  • Dae Kyung Noh;Dong Won Lee;Taek June Kim;Joo Sup Jang
    • Journal of Drive and Control
    • /
    • v.20 no.1
    • /
    • pp.27-33
    • /
    • 2023
  • From the perspective of dental chair manufacturers, it is important to of localizing hydraulic system in order to secure market competitiveness. This study aims to develop the analysis model of a dental chair which overseas companies secure core technologies. The study follows the steps below. First, the component parts of the solenoid valve unit of a foreign leading company are analyzed and implemented in virtual environment. Second, dynamic behavior scenario is established based on solenoid valve signal chart provided by a foreign leading company. The analysis model is verified and its performance is analyzed using dynamic behavior according to each scenario. Third, a simulation is carried out to determine whether the cylinder velocity of designed hydraulic system surpasses 1cm/s as required by the design.

Closed-Loop Cooling System for High Field Mangets (고자기장용 자석을 위한 밀폐순환형 냉각장치)

  • Choi, Y.S.;Kim, D.L.;Lee, B.S.;Yang, H.S.;Painter, T.A.;Miller, J.R.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.1
    • /
    • pp.59-64
    • /
    • 2006
  • A closed-loop cryogenic cooling system for high field magnets is presented. This design is motivated by our recent development of cooling system for 21 tesla Fourier Transform ion Cyclotron Resonance (FT-ICR) superconducting magnets without any replenishment of cryogen. The low temperature superconducting magnets are immersed in a subcooled 1.8 K bath, which is connected hydraulically to the 4.2 K reservoir through a narrow channel. Saturated liquid helium is cooled by Joule-Thomson heat exchanger and flows through the JT valve, isenthalpically dropping its pressure to approximately 1 6 kPa, corresponding saturation temperature of 1.8 K. Helium gas exhausted from pump is now recondensed by two-stage cryocooler located after vapor purify system. The amount of cryogenic Heat loads and required mass flow rate through closed-loop are estimated by a relevant heat transfer analysis, from which dimensions of JT heat exchanger and He II heat exchanger are determined. The detailed design of cryocooler heat exchanger for helium recondensing is performed. The effect of cryogenic loads, especially superfluid heat leak through the gap of weight load relief valve, on the dimensions of cryogenic system is also investigated.

Tetralogy of Fallot: A Surgical Perspective

  • Karl, Tom R.
    • Journal of Chest Surgery
    • /
    • v.45 no.4
    • /
    • pp.213-224
    • /
    • 2012
  • Tetralogy of Fallot (TOF) is an index lesion for all paediatric and congenital heart surgeons. In designing an appropriate operation for children with TOF, the predicted postoperative physiology must be taken into account, both for the short and long term. A favourable balance between pulmonary stenosis (PS) and pulmonary insufficiency (PI) may be critical for preservation of biventricular function. A unified repair strategy to limit both residual PS and PI is presented, along with supportive experimental evidence. A strategy for dealing with coronary anomalies and some comments regarding best timing of operation are also included.

SimulationX®-based Modeling for Valve-Plate Notch Design of Variable Swash-Plate Axial Piston Pump (SimulationX®를 이용한 가변 사판식 액셜 피스톤 펌프의 밸브플레이트 노치 최적화에 관한 연구)

  • Lee, San Seong;Chung, Won Jee;Lim, Dong Jae;Cha, Tae Hyung;Kim, Soo Tae;Lee, Jeong Sil;Choi, Kyung Shin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.4
    • /
    • pp.104-112
    • /
    • 2018
  • Considering the shape of a valve plate in design is important for reducing the pulsation phenomenon, which is a negative factor in pump performance. The purpose of this study is to propose an optimized method for a valve-plate V-type notch of a piston pump by modeling and simulation. The method uses $SimulationX^{(R)}$, a commercial hydraulic analysis program, and to provide data for the designing of the notch. The opening areas are determined by performing kinematic analysis of the notch part where the opening area changes rapidly. After applying the result analysis, the main effects on maximum pressure pulsation and maximum backflow according to the notch design factors are analyzed by using the full factorial method of experimental design. The optimized solutions are derived for the notch design variables, based on the analyzed data.

Experimental Study on the Performance of Heat Recovery Heat Pump System using R245fa Refrigerant (R245fa 냉매를 이용한 배열회수 히트펌프 시스템 성능에 관한 실험적 연구)

  • Kim, Hyuntaek;Kim, Yongchan;Cha, Dongan;Kwon, Ohkyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.10
    • /
    • pp.408-413
    • /
    • 2016
  • The objective of this study is to investigate the performance of a heat recovery heat pump dryer using a R245fa refrigerant experimentally. In this study, the main components of the heat pump dryer were an evaporator, a compressor, a condenser, and an expansion valve. As a result, when the amount of refrigerant varied from 15 kg to 16 kg, the hot air outlet temperature in the condenser and the heat transfer rate were almost kept constant. Therefore, the amount of refrigerant at 16 kg was considered to be a suitable amount in the heat pump. As the air inlet velocity varied from 0.5 m/s to 1.5 m/s, the highest temperature in the condenser could be obtained when the air inlet velocity was 0.5 m/s. The heat transfer rate, system (COP), and hot air outlet temperature were 5.6 kW, 3.4, and $102.5^{\circ}C$, respectively, when the bypass ratio and water temperature were 0% and $60^{\circ}C$.

Determination of PID Coefficients for the Ascending and Descending System Using Proportional Valve of a Rice Transplanter

  • Siddique, Md. Abu Ayub;Kim, Wan-Soo;Baek, Seung-Yun;Kim, Yeon-Soo;Choi, Chang-Hyun;Kim, Yong-Joo;Park, Jin-Kam
    • Journal of Biosystems Engineering
    • /
    • v.43 no.4
    • /
    • pp.331-341
    • /
    • 2018
  • Purpose: This study was conducted to develop a linear Proportional-Integral-Derivative (PID) control algorithm for the ascending and descending system of a rice transplanter and to analyze its response characteristics. Methods: A hydraulic model using a single-acting actuator, proportional valve and a PID control algorithm were developed for the ascending and descending system. The PID coefficients are tuned using the Ziegler-Nichols (Z-N) method and the characteristics of unit step response are analyzed to select the PID coefficients at various pump speeds. Results: Results showed that the performance of the PID controller was superior in any condition. It was found that the highest settling time and maximum overshoot were less than 0.210 s and 5%, respectively at all pump speed. It was determined that the steady state errors were 0% in all the cases. The lowest overshoot and settling time were calculated to be nearly 2.56% and 0.205 s, respectively at the pump rated speed (2650 rpm). Conclusions: The results indicated that the developed PID control algorithm would be feasible for the ascending and descending system of a rice transplanter. Finally, it would be helpful to plant the seedlings uniformly and improve the performance of the rice transplanter.

Identification of Noise Source from Main Steam Line in Power Plant (발전소 주증기 배관 소음 발생 원인 규명)

  • Sohn, M.S.;Lee, J.S.;Lee, S.K.;Lee, W.R.;Lee, S.K.
    • Journal of Power System Engineering
    • /
    • v.7 no.3
    • /
    • pp.23-28
    • /
    • 2003
  • In heavy nuclear power plant, high energy through main steam line is provided to turbine that generate the electric power. Since plant had generated power, high noise has been occurred. Noise make equipments and work environment worse. For finding out the location and the cause of making noise, noise was measured along main steam line at open/close test of Main Steam Isolation Valve (MSIV hereafter). As the result, it was identified that the vortex shedding in the cavity of MSIV is main noise source. The profile change of MSIV seat ring was proposed as the method of noise reduction. After filletting MSIV seat ring, the noise level reduced $10{\sim}20dB$ compared before the change of profile.

  • PDF

Blood pressure simulator using hybrid controller (합성제어기를 이용한 혈압 시뮬레이터의 구현)

  • Kim, C.H.;SaGong, G.;Nam, Gi-Gon;Jeon, R.
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.44-51
    • /
    • 2007
  • A hybridized simulator for generating blood pressure waveform is proposed to study the remedy and/or evaluation of the conventional sphygmomanometer utilizing the oscillometric method which is widely applied. The blood pressure of a flowing fluid was controlled for the blood vessel's condition caused by a rhythmical and periodical contraction/relaxation because of the special excitatory and conductive system of the heart. In this study, a hybridized controller composed of the PI feedback controller and the feedforward controller. The inverse dynamics function is proposed to operating the control valve while the pressure is applied in an oil pressure tank. The proposed hybrid simulator reproducing the blood pressure waveform in an artificial blood vessel has kept the control performance consistent over all range. Based on these results, the proposed simulators could be applied to the development and compensation of the non invasive sphygmomanometer type as well as to study the characteristics of the blood pressure and blood vessel.

Measurement method for control valve noise (콘트롤 밸브의 소음 측정 방법)

  • Lee Y. B.;Yoon B. R.;Park K. A.;Lee D. H.;Yoo S. H.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.515-518
    • /
    • 2002
  • 콘트롤밸브는 지역 냉${\cdot}$난방 및 APT, 대형 빌딩의 냉온수, 중온수 및 공조배관 시스템에 사용되어 유체적 바란스를 이루는데 사용된다. 이와같이 유체의 흐름을 조절하기 위하여 사용되는 콘트롤 밸브가 때로는 소음 문제를 일으키기도 한다. 최근 들어 밸브의 소음이 문제가 되는 경우가 빈번해 지고 있다. 밸브의 기본적 기능을 충족시키기 위해서는 영구적인 수두 손실이 필요하며 이러한 수두손실을 발생시키는 과정에서 유체 흐름에 의해 발생한 난류가 커다란 밸브 소음을 유발하게 된다. 본 연구에서는 콘트롤 밸브 소음 특성 평가 방법을 검토하였다. 밸브 및 배관으로 이루어진 시스템에서 발생되는 소음을 예측하는 절차를 살펴보았다. 밸브의 음향 파워레벨을 측정하고 유량 및 차압의 변화에 따른 소음 예측식을 결정 하였다. 본 연구에서 제시한 밸브 소음 측정 방법은 새로운 밸브의 소음특성 평가, 밸브 소음의 예측 그리고 서로 다른 밸브 사이의 성능비교 등에 사용될 수 있을 것이다.

  • PDF

A new merging-zone flow injection system for the quantification of ferrous and ferric ions in aqueous solution and sludge of wastewater

  • Farhood, Ahmed Saleh;Taha, Dakhil Nassir
    • Analytical Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.218-227
    • /
    • 2022
  • A simple and fast throughput flow injection (FI) system with a merging-zone technique was designed to determine ferrous and ferric in an aqueous solution. The method is based on the direct reaction of ferrous with a Bathophenanthroline reagent (Bphen) in acidic media. The forming red complex absorbs light at 533 nm. All conditions of the flow injection system were investigated. The analytical curve of ferrous was linear in the range of 0.07 to 4 mg/L with an r2 value of 0.9968. The detection and quantification limits were 0.02 and 0.04 mg/L, respectively. The molar absorptivity and Sandell's sensitivity were 4.0577 × 106 L/mol cm and 25 × 10-5 ㎍/cm2, respectively. The homemade valve was low-cost with high repeatability (n = 7) at an RSD of 1.26 % and zero dead volume. The values of the dispersion coefficient were 2.318, 2.022, and 1.636 for the concentrations of 0.2, 1, and 3 mg/L, respectively. The analysis throughput of the designed flow injection unit was 57 sample per hour.