• Title/Summary/Keyword: S/N Ratio(Signal to Noise Ratio)

Search Result 187, Processing Time 0.031 seconds

SH-EMAT에 의한 Digital 신호처리에 관한 연구

  • 김재열;박환규;조영태;김형일
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.04b
    • /
    • pp.198-203
    • /
    • 1993
  • In this study, byusing EMAT(Electro Magnetic Acoustic Transducer) the artificial slit is installed on 12B-SUS pipe test piece. By mading 4 cycle SH-bust wave (EMA) incidence to 45 .deg. angle, the signaldata of pulse, which is recevied from EMAT translated intodigital-signal-processing-method SSP and Deconvolution method by using FACOM. Results of these indicated that (1) this method of this study shows exellent result more than Ultrasonic testing method; (2) noise is well removed by SSP using signal dataa and resolving power and S/N ratio are advanced; (3) regradless of Ultrasonic wave, whichhas properties of generalstainless steel is generated into multiscattering and reflection phenomena, the resolving power of more than two times is progressed by being translated into Decon-volution method; and (4) as addition-averaging-processing number is increaing, the resolving power and S/N ratio are improved and the satisfactory signal is obtained.

Hepatocellular carcinomas: correlation of enhancement degree with pathologic grades triple contrast MR imaging

  • Kim, Joo-Hee;Kim, Myeong-Jin;Park, Young-Nyun;Kim, Kyung-Sik;Lee, Woo-Jung
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.108-108
    • /
    • 2001
  • Purpose: To correlate the histological differentiation of hepatocellular carcinomas (HCCs) with finding on triple contrast-enhanced MR imaging using gadolinium-chelates, superparamganetic ire oxides (SPIO), and mangafodipir trisodium. Method: Ten patients with proven HCC underwent triple contrast-enhanced MRI befo surgical resection. Subjective ratings of the enhancement pattern and degree were compare with the histological grades determined on surgical specimen. Quantitative measurements signal-to-noise ratio (S/N) of the lesion and the lesion-to-liver contrast-to-noise ratio C/N on the enhanced MR images, and the degree of S/N and C/N changes between the unenhanced and enhanced images were also correlated with the histological grades.

  • PDF

Evaluation of Roadmap Image Quality by Parameter Change in Angiography (혈관조영검사에서 매개변수 변화에 따른 Roadmap 영상의 화질평가)

  • Kong, Chang gi;Song, Jong Nam;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.53-60
    • /
    • 2020
  • The purpose of this study is to identify factors affecting picture quality in Roadmap images, which were studied by varying the dilution rate, collimation field and flow rate of contrast medium. For a quantitative evaluation of the quality of the picture, a 3mm vessel model Water Phantom was self-produced using acrylic, a roadmap image was acquired with a self-produced vascular model Water Phantom, and the SNR(Signal to Noise Ratio) and CNR (Contrast to Noise Ratio) were analyzed. CM:N/S In the study on the change of dilution rate, CM:N/S dilution rate changed to (100%~10%:100%), and the measurement of the roadmap image taken using the vascular model Water Phantom showed that the measurement value of SNR gradually decreased as the N/S dilution rate was increased, and the measurement of CNR was gradually reduced. It was confirmed that the higher the dilution rate of CM:N/S, the lower the SNR and CNR, and also significant image can be obtained at the dilution rate of CM:N/S (100%~70:30%). The study showed the value of SNR and CNR in Roadmap image was increased as the Collimation Field was narrowed to the center of the vascular phantom; the Collimation Field was narrowed to the center of the vessel model by 2cm intervals to 0cm through 12cm. To verify the relationship with Roadmap image and Flow Rate, volume of the autoinjector was kept constant at 15 and the flow rate was gradually increased 1, 2, 3, 4, 5, 6, 7, 8, 9, 10. The value of SNR and CNR of images taken by using water Phantom gradually decreased as the Flow Rate increased, but at Flow Rate 9 and 10, the SNR and CNR value was increase. It was not possible to confirm the relationship with SNR and CNR by ROI mean value and Background mean value. It is considered that further study is needed to evaluate the correlation about Roadmap image and Flow Rate. In conclusion, as the dilution rate of N/S in contrast medium was increased, the value of SNR and CNR was decreased. The narrower the Collimation Field, the higher image quality by increasing value of SNR and CNR. However, it is not confirmed the relationship Roadmap image and Flow Rate. It is considered that appropriate contrast medium concentration to minimize the effects of kidney and proper Collimation Field to improve contrast of image and reduce exposure X-ray during procedure is needed.

Assessment of Osteoporosis Based on Changes in SNR and ADC Values on MR Diffusion Weighted Images (확산강조영상에서 신호대 잡음비, 현성 확산 계수 변화에 따른 골다공증 평가)

  • Cho, Jae-Hwan;Kim, Yeong-Soo
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.70-77
    • /
    • 2010
  • This study tested how S/N (Signal to Noise Ratio) ratios and ADC (apparent diffusion coefficient) values vary with different T-scores in a group of patients with osteoporosis. Based on DEXA (Dual Energy X-ray Absorptiometry) T-scores for L1.L4 for two groups of subjects consisting of 30 healthy people without osteoporosis and 30 patients who came for treatment of waist (lumbar or low back) pain and were suspected to have osteoporosis as judged from the simple X-ray findings, this study classified every spine into two groups of osteoporosis and osteopenia. Signal intensity measurements were made in the four regions of L1 to L4 on diffusion-weighted MR images obtained using 1.5T MR scanner, while ADC measurements were obtained from ADC map images. As an approach for quantitative analysis, the comparison of the variances in S/N ratios and ADC values for varying T-scores in the selected regions of interest was carried out based on averaged T-scores, S/N ratios, and ADC values. Also, the variances in S/N ratios and ADC values for each of the groups of osteoporosis and osteopenia, which were classified into by T-scores, were compared. For qualitative analysis, a careful naked eye examination of signal intensity differences in the area of L4 was made on T1-weighted sagittal images for each of the healthy (normal), osteopenia, and osteoporosis groups. In the qualitative analysis, it was found that for both the osteopenia group and the osteoporosis group, as T-scores deceased, the S/N ratios on diffusion-weighted MR images also decreased, with the greatest decrease in the S/N ratio found in the osteoporosis group. Additionally, among the three groups, the lowest S/N ratio was found in the osteoporosis group. With respect to ADC map, it was found that for both the osteopenia group and the osteoporosis group, as T-scores deceased, the ADC values on diffusion-weighted MR images also decreased, with the greatest decrease in the ADC values found in the osteoporosis group. Additionally, among the three groups, the lowest ADC value was found in the osteoporosis group. On the other hand, in the qualitative analysis, the osteoporosis group showed the highest signal intensity. Additionally, among the three groups, the lowest signal intensity was found in the healthy (normal) group. It was found that as osteoporosis progressed, S/N ratio and ADC decreased, whereas signal intensity increased on T1-weighted images. Also, in diagnosing osteoporosis, MRI tests turned out to be (more) effective.

A Study on the Effective Arc Sensing by the Use of the Weighted-Arc-Current in Flux-Cored Arc Welding for Fillet Joints (가중용접전류를 이용한 FCAW 필릿용접용 아크센싱 알고리즘 연구)

  • 권순창;최재성
    • Journal of Welding and Joining
    • /
    • v.18 no.1
    • /
    • pp.83-90
    • /
    • 2000
  • It was attempted to improve seam-tracking performance by applying a new arc-sensing algorithm for FCAW(flux-cored arc welding) process in fillet joints. For this study the authors have introduced three different weight factors: $\circled1$ arc currents at the weaving end are more weighted, $\circled2$ arc currents are evenly weighted along the weaving, and $\circled3$ arc currents at the weaving center are more weighted. To evaluate the 3 factors the values of signal-to-noise(S/N) ratio has been measured. The values were obtained for various welding conditions with different gaps in horizontal and vertical fillet joints. The test results showed that the S/N ratio of the 1st case was highest which resulted in the best of seam tracking performance. In addition, the comparison between the seam tracking performance in horizontal fillet joints and that in vertical ones has been done, and the result showed that tracking performance in vertical joints was relatively better than that in horizontal joints.

  • PDF

An Adaptive Line Enhancer Using Lattice Notch Filters (격자형 노치 필터를 이용한 정현파 검출기)

  • 조남익;최종호;이상욱
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.4
    • /
    • pp.719-726
    • /
    • 1987
  • In this paper, an adaptive IIR (infinite impulse response) notch filter of lattice type is constructed and its adaptation algorithm is proposed for the detection and retrieval of a sine wave signal embedded in noise. A modified method which adapts only one coefficient of the filter is also suggested. All these methods adapt the coefficients while keepting the poles of the filter inside the unit circle on z-plane, and thus they satisfy the condition on the stability of the IIR filter after it has converged. To investigate the convergence characteristics of these methods such as convergence speed and output S/N ratio, intensive computer simulation has been performed by varying the frequency of the sine wave and the input S/N ratio. And the results of the simulation have been compared to those of Rao and Kung's which shows relatively fast convergence speed. The methods proposed here, especially the second one. shows faster convergence speed and higher output S/N ratio than the Rao and Kung's.

  • PDF

Pseudo Optical PAM-N Signal Using Externally Modulated Lasers

  • Huh, Joon Young;Lee, Joon Ki;Kang, Sae-Kyoung;Lee, Jyung Chan
    • ETRI Journal
    • /
    • v.37 no.6
    • /
    • pp.1120-1128
    • /
    • 2015
  • We propose a pseudo optical N-level pulse-amplitude modulation (PO PAM-N) signal using a few externally-modulated lasers (EMLs) operating at different wavelengths, which is suitable for upgrading the transmission speed over an optical link of < 10 km single-mode fiber with low-cost components. To compare a PO PAM-N signal with that of a standard optical PAM-N signal, we perform experiments for evaluating the performance of a 51.56-Gb/s PO PAM-4 signal and standard 51.56-Gb/s optical PAM-4 signal. The receiver sensitivity (at $BER=10^{-5}$) of the PO PAM-4 signal is 1.5 dB better than the receiver sensitivity of a standard optical PAM-4 signal. We also investigate the feasibility of PO PAM-N (N = 4, 8, and 16) signals operating at 103.12 Gb/s, considering relative intensity noise, timing jitter, extinction ratio (ER) of EMLs, and dispersion. From the results, a PO PAM-8 signal performs better than PO PAM-4 and PO PAM-16 signals at 103.12 Gb/s. Finally, we suggest a timing control method to suppress the effect of dispersion in a PO PAM-N signal. We show that the tolerance to dispersion of a 103.12-Gb/s PO PAM-8 signal can be improved to ${\pm}40ps/nm$ by applying a proposed scheme.

Application of Blind Deconvolution with Crest Factor for Recovery of Original Rolling Element Bearing Defect Signals (볼 베어링 결함신호 복원을 위한 파고율을 이용한 Blind Deconvolution의 응용)

  • Son, Jong-Duk;Yang, Bo-Suk;Tan, A.C.C.;Mathew, J.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.585-590
    • /
    • 2004
  • Many machine failures are not detected well in advance due to the masking of background noise and attenuation of the source signal through the transmission mediums. Advanced signal processing techniques using adaptive filters and higher order statistics have been attempted to extract the source signal from the measured data at the machine surface. In this paper, blind deconvolution using the eigenvector algorithm (EVA) technique is used to recover a damaged bearing signal using only the measured signal at the machine surface. A damaged bearing signal corrupted by noise with varying signal-to-noise (s/n) was used to determine the effectiveness of the technique in detecting an incipient signal and the optimum choice of filter length. The results show that the technique is effective in detecting the source signal with an s/n ratio as low as 0.21, but requires a relatively large filter length.

  • PDF

Transmitter Beamforming and Artificial Noise with Delayed Feedback: Secrecy Rate and Power Allocation

  • Yang, Yunchuan;Wang, Wenbo;Zhao, Hui;Zhao, Long
    • Journal of Communications and Networks
    • /
    • v.14 no.4
    • /
    • pp.374-384
    • /
    • 2012
  • Utilizing artificial noise (AN) is a good means to guarantee security against eavesdropping in a multi-inputmulti-output system, where the AN is designed to lie in the null space of the legitimate receiver's channel direction information (CDI). However, imperfect CDI will lead to noise leakage at the legitimate receiver and cause significant loss in the achievable secrecy rate. In this paper, we consider a delayed feedback system, and investigate the impact of delayed CDI on security by using a transmit beamforming and AN scheme. By exploiting the Gauss-Markov fading spectrum to model the feedback delay, we derive a closed-form expression of the upper bound on the secrecy rate loss, where $N_t$ = 2. For a moderate number of antennas where $N_t$ > 2, two special cases, based on the first-order statistics of the noise leakage and large number theory, are explored to approximate the respective upper bounds. In addition, to maintain a constant signal-to-interferenceplus-noise ratio degradation, we analyze the corresponding delay constraint. Furthermore, based on the obtained closed-form expression of the lower bound on the achievable secrecy rate, we investigate an optimal power allocation strategy between the information signal and the AN. The analytical and numerical results obtained based on first-order statistics can be regarded as a good approximation of the capacity that can be achieved at the legitimate receiver with a certain number of antennas, $N_t$. In addition, for a given delay, we show that optimal power allocation is not sensitive to the number of antennas in a high signal-to-noise ratio regime. The simulation results further indicate that the achievable secrecy rate with optimal power allocation can be improved significantly as compared to that with fixed power allocation. In addition, as the delay increases, the ratio of power allocated to the AN should be decreased to reduce the secrecy rate degradation.

Performance improvement of active noise control using on-line estimation of secondary path transfer function (부가경로 전달함수의 온라인 예측에 의한 능동소음제어의 성능 향상)

  • Kim, Heung-Seob;Sohn, Dong-Gu;Oh, Jae-Eung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.2
    • /
    • pp.281-287
    • /
    • 1997
  • In the conventional inverse modeling method for on-line modeling of the secondary path transfer function, the signal to noise ratio between the arbitrary random signal and the plant noise have to keep at -10 - -20 dB. For these reasons, the modeling can't be exactly implemented by the conventional method alone and the convergence time for modeling becomes too long. In this study, by combining the conventional inverse modeling method with an adaptive line enhancer, or with an adaptive noise canceller, a rigorous transfer functions of secondary path modeling and the control of a primary noise have been implemented simultaneously.