• Title/Summary/Keyword: S/L ratio

Search Result 2,440, Processing Time 0.035 seconds

The Effect of Nutritional Balance between Carbon and other Nutrient Sources on the Growth of Sporobolomyces holsaticus (탄소원과 다른 영양원간의 영양균형이 Sporobolomyces holsaticus의 균체생육도에 미치는 영향)

  • Park, Wan-Soo;Koo, Young-Jo;Shin, Dong-Hwa;Min, Byung-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.56-61
    • /
    • 1983
  • Direct production of biomass from starch using amylolytic yeast, Sporobolomyces holsaticus FRI Y-5 was studied with varying the ratios between carbon and other nutrient sources in the medium. It was investigated under condition of constant C/P and C/S ratio to influence the initial concentration of starch $(S_o)$ and C/N ratio on its growth which is described as the specific growth rate $({\mu})$, cell yield (Y), the maximum concentration of cell $(X_m)$, and productivity (P). They were very dependent on both $S_o$ and C/N ratio. The form of the relationship between and ${\mu}$ and $S_o$ was observed to be similar to saturation kinetics at C/N = 100 but presented substrate inhibition at other C/N ratios. As $S_o$ was changed from 22.5 to 90 g/l, Y was observed to vary with C/N ratios but seemed to decrease as a wholes. $X_m$ was linearly related to $S_o$ at more than C/N = 50 but at less than C/N = 10 substrate inhibition was presented. P increased suddenly to $S_o$ = 45 g/l and then changed decreasingly at less than C/N = 50, but at more than C/N = 100 it changed increasingly. The effect of C/P ratio and C/S ratio on the yeast growth was also investigated at constant $S_o$ and C/N ratio. ${\mu}$ was dependent on C/P and C/S ratios, but Y, independent on them. But $X_m$ was reliant upon C/P ratio but not upon C/S ratio.

  • PDF

An Experimental Study to Predict Minimum Shear Reinforcement Ratio of RC Beams with Various Shear Span-to-Depth Ratios (전단경간비가 다른 철근콘크리트 보의 최소전단철근비 예측에 관한 실험적 연구)

  • 김욱연;김상우;이정윤
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.890-895
    • /
    • 2003
  • The purpose of this experimental study is to investigate the influence of shear span-to-depth ratio on the minimum shear reinforcement ratio of reinforced concrete beams. In this study, 7 reinforced concrete beam specimens were tested. The parameters of experiment are shear span-to-depth ratio(a/d=2.0, 3.0, 4.0) and shear reinforcement ratio($p_v$=0%, 0.183%, and 0.233%). The section of all secimens was 350mm width and 450mm depth. The observed results were compared with the calculated results by the current ACI 318-02 Building Code and the proposed equation. The safety rate of the specimens, L5S2A, L5S3A, L5S4A, and L5S4P specimens were 1.80, 1.25, 1.38, and 1.56 respectively. The test results indicated that the shear behavior of reinforced concrete beams with the minimum shear reinforcement was influenced by the shear span-to-depth ratio.

  • PDF

Analysis of Lipid Composition in Various Fast-Foods (시판 패스트 푸드의 지질조성에 관한 연구)

  • 김난숙;김성애
    • Korean journal of food and cookery science
    • /
    • v.10 no.2
    • /
    • pp.131-137
    • /
    • 1994
  • This study was to investigate fat content and fatty acid composition of 19 various fast-foods. Fat content per serving in double cheese burger was 38.8g, shrimpburger 27.5g, gogi-mandoo 26.3g, pizza 25.8g and chicken nuggets 18.8g, respectively, Fatty acid contained in fast-foods mostly were oleic acid, palmitic acid, linoleic acid and stearic acid. The ratio of P/S in yubuLchobab was 3.l/l, ccochinoodle 2.3/l, pork cutlet 2.3/l, bibimbab 1.511 and shrimpburger 1.3/l when all the other tested fast-foods'P/S were less than 1. The ratio of P/M/S in ham cheese sandwich was 1/1/1, shrimpburger 1.3/1.5/l, bibimbab 1.s/l.5/l, which are similar to recommended 1∼1.5/1∼1.5/l. The ratio of 6/3 fatty acids was found to be kimbab(34.0/l), chicken nuggets(25.3/l), ccochi noodle(20.0/l), yubu-chobab (16.5/l), fried chicken(16.3/l), chickenburger(12.6/l) and hot dog(10.2/1), which were higher than 10/1. Also pizza(3.511), spaghetti(3.7/l) were lower than 4/1. The rest of the fast-foods were within the range of 4/1∼10/1.

  • PDF

Urban Tissue, Zoning and Achieved Floor Area Ratio (A-FAR) - Focused on Developed Floor Area Ratio (D-FAR) Compared to the Legal Floor Area Ratio (L-FAR) in Residential Area and Commercial Area in Seoul - (용적실현비(A-FAR)에 영향을 미치는 용도지역별 대지특성에 대한 분석 - 서울시 주거지역 및 상업지역에서 법정용적률(L-FAR) 대비 실현된 용적률(D-FAR)을 중심으로 -)

  • Kim, Soo Hyun;Choi, Chang Gyu
    • Journal of Korea Planning Association
    • /
    • v.54 no.2
    • /
    • pp.33-45
    • /
    • 2019
  • The Legal Floor Area Ratio (L-FAR) has been used as a major urban planning tool for efficient management of land use, landscape, and density. The Developed Floor Area Ratio (D-FAR) in each parcel is realized by such physical and institutional factors as urban tissue, local characteristics, and zoning with the L-FAR. The Achieved Floor Area Ratio (A-FAR), the ratio of the D-FAR to the L-FAR, is the relationship between realized density and the intended/desired outcomes of the regulations. The A-FAR informs the efficiency of L-FAR and its effect on parcels, and is an indicator of the demands of real estate developments under the zoning regulation. This study used detailed data of each parcel's characteristics, including parcel size, road width, and the number of roads bordered by a parcel, to identify the influencing factors on A-FAR. This analysis confirmed that the parcel size has a non-linear negative effect in the residential zone but a linear positive effect on A-FAR in the commercial zone. The width of the parcel's frontage in the commercial zone has a positive effect on the value, while in the residential zone the narrower width has higher A-FAR. In Seoul, the residential zone has higher A-FAR than the commercial zone, which means that the former has a relatively higher development pressure but a lower designated L-FAR. This result reflects that Seoul's residential zone absorbs the demand of commercial uses because of the significant permitting of mixed land use and has high-density residential buildings.

N,N'-Dimethylethylenediamine-N,N'-di-α-butyric Acid Cobalt(III) Complexes Utilizing Oxidation of Sulfur of S-Methyl-L-cysteine

  • Kim, Hyun-Jin;Youm, Kyoung-Tae;Yang, Jung-Sung;Jun, Moo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.6
    • /
    • pp.851-856
    • /
    • 2002
  • The Reaction of S-methyl-S-cysteine(L-Smc) with racemic $s-cis-[Co(demba)Cl_2]-1$ (Hydmedba = $NN'-dimethylethylenediamine-NN'-di-\alpha-butyric$, acid) yields ${\Delta}$-s-cis-[Co(dmedba)(L-Smc)] 2 with N, O-chelation. Oxidation of sulfur of 2 with $H_2O_2$ in a 1 : 1 mole ratio gives ${\Delta}$-s-cis[Co(dmedba)(L-S(O)mc)] 3 having an uncoordinated sulfenate group. Oxidation of sulfur of L-Sm with $H_2O_2in$ a 1: 1 mole ratio produces S-methyl-L-cysteinesulfenate (L-S(O)me) 5. Direct reaction of 1 with 5 in basic medium gives an N.O-chelated ${\Delta}$s-cis[Co(dmedba)(L-S(O)mc)-N.O], which turmed out be same as obtained by oxidation of 2, while an N, S-chelated ${\Delta}$-s-cis-[Co(dmedba)(S-S(O)mc)-N,O] complex 4 is obtained in acidic medium from the reaction of 1 with 5. This is one of the rare $[$Co^{III}$(N_2O_2-type$ ligand)(amino acid)] type complex preparations, where the reaction conditions determine which mode of N, O and N, S caelation modes is favored.

A study on the parameters for biodegradable characteristics of sewage discharged intermittently (부정기적 발생 오수의 유기물 생분해도 특성 parameter 산정에 관한 연구)

  • Han, Gee-Bong;Lee, Young-Sin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.3
    • /
    • pp.41-52
    • /
    • 2014
  • In this study, to estimate the biodegradability of sewage discharged intermittently, field scale sampling and analysis was conducted and the results were obtained as follows. According to results of the biodegradability of sewage discharged intermittently, average concentration of TCODcr is 325.5mg/L and ratio of TCOD fraction resulted 100%. Also, average concentration of SCODcr resulted 135.9mg/L and ratio of TCOD fraction resulted 41.8%. Average concentration of Ss showed 74.1mg/L and ratio of TCOD fraction resulted 22.8%. Average concentration of $S_I$ was analyzed to be 61.8mg/L and ratio of TCOD fraction was calculated to 19.0%. Xs which is particulate matter was analyzed to show 27.8mg/L and ratio of TCOD fraction also showed 8.5%. Average concentration of $X_H$ is 103.4mg/L and ratio of TCOD fraction resulted 31.8%. Inert particulate matter showed that average concentration of $X_I$ is 58.5mg/L and ratio of TCOD fraction resulted 18.0%. Accordingly, dissolved biodegradable organic matter showed the ratio of 41.8%, and readily biodegradable matter among this showed 22.8%. Thus intermittent inflow is expected to have less effect with regards equalization by organic loading rate of influent.

Applicability of the Burr XII distribution through dimensionless L-moment ratio of rainfall data in South Korea (우리나라 강우자료의 무차원 L-moment ratio를 통한 Burr XII 분포의 수문학적 적용성 검토)

  • Seo, Jungho;Shin, Hongjoon;Ahn, Hyunjun;Heo, Jun-Haeng
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.3
    • /
    • pp.211-221
    • /
    • 2017
  • In statistical hydrology, various extreme distributions such as the generalized extreme value (GEV), generalized logistic (GLO) and Gumbel (GUM) models have been widely used to analyze the extreme events. In the case of rainfall events in South Korea, the GEV and Gumbel distributions are known to be appropriate among various extreme distribution models. However, the proper probability distribution model may be different depending on the type of extreme events, rainfall duration, region, and statistical characteristics of extreme events. In this regard, it is necessary to apply a wide range of statistical properties that can be represented by the distribution model because it has two shape parameters. In this study, the statistical applicability of rainfall data is analyzed using the Burr XII distribution and the dimensionless L-moment ratio for 620 stations in South Korea. For this purpose, L-skewness and L-kurtosis of the Burr XII distribution are derived and L-moment ratio diagram is drawn and then the applicability of 620 stations was analyzed. As a result, it is found that the Burr XII distribution for the stations of the Han River basin in which L-skewness is relatively larger than L-kurtosis is appropriate, It is possibility of replacing the distribution of commonly used Gumbel or GEV distributions. Therefore, the Burr XII model can be replaced as an appropriate probability model in this basin.

A Study on the Location of Measurements in the Abdominal Fat using CT (In asymptomatic Korean individual) (CT를 이용한 복부 지방측정에서 측정 위치에 대한 고찰 (무증상 한국인을 대상으로))

  • Lee, Sang-Heon;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.685-693
    • /
    • 2020
  • This study was performed to compare the differences between total fat area, subcutaneous fat area and visceral fat area according to L1-S1 inter vertebral disc level in asymptomatic Korean patients with non-contrast abdominal CT scan. The location of the maximum fat ratio of the total fat area is the total fat area measured in male L2-3, L3-4, L4-5, female L4-5, and L5-S1. The location showing the maximum fat ratio of the subcutaneous fat area is the subcutaneous fat area measured in male L4-5, and the woman is the subcutaneous fat area measured in L4-5 and L5-S1. The location of the maximum fat ratio of visceral fat area was the visceral fat area measured in L1-2 and L2-3 males, and there was no difference in visceral fat area according to the measured position in females. Although abdominal fat measurement is common at the L4-5 inter vertebral disc level, fat distribution varies widely depending on nationality, race, and gender. Therefore, it is necessary to analyze through the research data which location to choose according to the research purpose, and to mention why the location is appropriate.

Measurement Conditions of Concrete Pull-off Test in Field from Finite Element Analysis (유한요소 해석을 이용한 현장 콘크리트 부착강도 측정조건)

  • Kim, Seong-Hwan;Jeong, Won-Kyong;Kwon, Hyuck;Kim, Hyoun-Oh;Lee, Bong-Hak
    • Journal of Industrial Technology
    • /
    • v.22 no.A
    • /
    • pp.185-192
    • /
    • 2002
  • The performance of old and the new concrete construction depends upon bond strength between old and the new concrete. Current adhesive and strength measurement method ignores the effect of stress concentration from shape of specimens. Therefore, this research calculates stress concentration coefficient as the ratio of drilling depth to drilling diameter($h_s/D$), the ratio of overlay thickness to drilling diameter($h_0/D$), the ratio of steel disk thickness to drilling diameter(t/D), the ratio of overlay elastic modulus to substrate modulus($E_1/E_0$), the distance from core to corner border(L_$_{corner}$) and the distance between cores(L_$_{coic}$) vary. The finite element method is adapted to analysis The results from 'the F.E.M analysis are as follows. The stress concentration effects can be minimized when the ratio of drilling depth to drilling diameter($h_s/D$) is 0.20~0.25, the elastic modulus ratio($E_1/E_0$) is 06~1.0, and the ratio of steel disk thickness to drilling diameter(t/D) is 3.0. The overlay thickness, the distance from specimens to corner border(L_$_{corner}$), the distance between cores(L_$_{coic}$) almost do not affect to the stress concentration.

  • PDF

Effect of Feed concentration (S0) and F/M ratio (S0/X0) on Anaerobic Digestion of Thickened Sewage Sludge (기질 농도 (S0)와 F/M 비 (S0/X0)가 농축 하수 슬러지 혐기성 소화에 미치는 영향)

  • Kim, Sang-Hyoun;Ju, Hyun Jun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.825-831
    • /
    • 2012
  • The retrofitting of a thickening unit process is widely considered in municipal wastewater treatment plants in Korea to enhance the anaerobic digestion efficiency. The authors examined the effect of feed concentration (2-34.1 g VS/L) and feed to microorganism (F/M) ratio (0.50-1.35 g VS/g VS) on anaerobic batch digestion of sewage sludge. Methane yield over 90 mL $CH_4/g$ $VS_{feed}$ was found at a feed concentration in the range of 12-26 g VS/L and a F/M ratio below 0.6 g VS/g VS. A high F/M ratio decreased methane yield and rate with oragnic acid accumulation. As sudden increase of sewage sludge concentration prior to anaerobic digestion would jeopardize the digester performance due to the rasied F/M ratio, gradual increase of the sludge feed concentration or an additional biomass retention in the digester is recommended.