• 제목/요약/키워드: Rubber bearing

검색결과 291건 처리시간 0.021초

The effect of base isolation and tuned mass dampers on the seismic response of RC high-rise buildings considering soil-structure interaction

  • Kontoni, Denise-Penelope N.;Farghaly, Ahmed Abdelraheem
    • Earthquakes and Structures
    • /
    • 제17권4호
    • /
    • pp.425-434
    • /
    • 2019
  • The most effective passive vibration control and seismic resistance options in a reinforced concrete (RC) high-rise building (HRB) are the base isolation and the tuned mass damper (TMD) system. Many options, which may be suitable or not for different soil types, with different types of bearing systems, like rubber isolator, friction pendulum isolator and tension/compression isolator, are investigated to resist the base straining actions under five different earthquakes. TMD resists the seismic response, as a control system, by reducing top displacement or the total movement of the structure. Base isolation and TMDs work under seismic load in a different way, so the combination between base isolation and TMDs will reduce the harmful effect of the earthquakes in an effective and systematic way. In this paper, a comprehensive study of the combination of TMDs with three different base-isolator types for three different soil types and under five different earthquakes is conducted. The seismic response results under five different earthquakes of the studied nine RC HRB models (depicted by the top displacement, base shear force and base bending moment) are compared to show the most suitable hybrid passive vibration control system for three different soil types.

Effectiveness of seismic isolation in a reinforced concrete structure with soft story

  • Hakan Ozturk;Esengul Cavdar;Gokhan Ozdemir
    • Structural Engineering and Mechanics
    • /
    • 제87권5호
    • /
    • pp.405-418
    • /
    • 2023
  • This study focused on the effectiveness of seismic isolation technique in case of a reinforced concrete structure with soft story defined as the stiffness irregularity between adjacent stories. In this context, a seismically isolated 3-story reinforced concrete structure was analyzed by gradually increasing the first story height (3.0, 4.5, and 6.0 m). The seismic isolation system of the structure is assumed to be composed of lead rubber bearings (LRB). In the analyses, isolators were modeled by both deteriorating (temperature-dependent analyses) and non-deteriorating (bounding analyses) hysteretic representations. The deterioration in strength of isolator is due to temperature rise in the lead core during cyclic motion. The ground motion pairs used in bi-directional nonlinear dynamic analyses were selected and scaled according to codified procedures. In the analyses, different isolation periods (Tiso) and characteristic strength to weight ratios (Q/W) were considered in order to determine the sensitivity of structural response to the isolator properties. Response quantities under consideration are floor accelerations, and interstory drift ratios. Analyses results are compared for both hysteretic representations of LRBs. Results are also used to assess the significance of the ratio between the horizontal stiffnesses of soft story and isolation system. It is revealed that seismic isolation is a viable method to reduce structural damage in structures with soft story.

납고무받침의 비선형성을 고려한 벤치마크 사장교의 복합제어 (Hybrid Control of a Benchmark Cable-Stayed Bridge Considering Nonlinearity of a Lead Rubber Bearing)

  • Park, Kyu-Sik;Jung, Hyun-Jo;Lee, In-Won
    • 한국지진공학회논문집
    • /
    • 제6권4호
    • /
    • pp.51-63
    • /
    • 2002
  • 본 논문에서는 지진하중을 받는 사장교의 진동제어 기법 개발을 위해 제공된 벤치마크 사장교에 복합제어 기법을 적용하였다. 이 벤치마크 문제는 2003년 완공 예정으로 미국 Missouri 주에 건설중인 Cape Girardeau 교를 대상 구조물로 고려하였다. Cape Girardeau 교는 New Madrid 지진구역에 위치하고 Mississippi 강을 횡단하는 주요 교량이라는 점 때문에 설계 단계에서부터 내진 문제를 중요하게 고려하였다. 벤치마크 문제에는 사장교의 상세한 설계도면에 기초해 교량의 복잡한 거동을 나타낼 수 있는 3자원 선형모델과 각 제어기법의 성능을 평가하기 위한 18개의 평가기준이 제시되어 있다. 본 연구에서 적용한 복합제어 기법은 지진하중으로 인해 구조물에 발생되는 하중을 줄이기 위한 수동제어 기법과 상판변위와 같은 구조물의 응답을 추가적으로 제어하기 위한 능동제어 기법이 결합된 제어 방법이다. 수동제어 장지로는 납고무받침을 사용하였고 Bouc-Wen 모델을 사용하여 비선형 거동을 고려 할 수 있도륵 모델링 하였다. 능동제어 장치로는 이상적인 hydraulic actuators 가 사용되었으며 제어 알고리듬은 $H_2$/LQG 를 적용하였다. 수치해석 결과 제안방법의 성능은 수동제어 방법에 비해 매우 효과적이며, 능동제어 방법에 비해서는 약간 좋은 제어성능을 나타내었다. 복합제어 방법은 수동제어 부분 때문에 능동제어 방법에 비해 보다 신뢰할 수 있는 제어 방법이다. 따라서 제안된 제어방법은 지진하중을 받는 사장교의 제어를 위해 효과적으로 사용될 수 있다.

신경망 이론을 적용한 납삽입 적층 고무베어링의 비선형 모델링 기법에 관한 연구 (A Study on the Nonlinear Modeling of Lead Rubber Bearings by a Neural Network Theory)

  • 허영철;김영중;김병현
    • 한국지진공학회논문집
    • /
    • 제8권4호
    • /
    • pp.63-69
    • /
    • 2004
  • 본 논문에서는 납삽입 적층 고무베어링의 비선형 모델링에 대해 신경망 이론을 적용한 수학적 모델링 기법을 제안하였다. 신경망 모델의 수치검증을 위해 납삽입 적층 고무베어링이 설치된 프레임 축소모델의 진동대 실험 자료가 사용되었는데, 제안된 신경망의 학습 및 예측을 위한 하중 자료로써 백색잡음과 세 종류의 지진파를 선택하였다. 지진파의 경우 PGA의 세기를 달리하여 신경망 모델의 계산정도를 고찰하였다. 그 결과, 납삽입 적층 고무베어링의 전단변위가 신경망의 학습 영역을 벗어나지 않는 경우 실험결과의 복잡한 이력곡선을 잘 추종하였고 신경망 이론에 의한 비선형 모델링 기법이 유용하게 활용될 수 있다는 가능성을 확인할 수 있었다.

납적층고무받침(LRB)으로 지지된 면진 원전 구조물의 수직방향 지진응답 분석 (Analyses of Vertical Seismic Responses of Seismically Isolated Nuclear Power Plant Structures Supported by Lead Rubber Bearings)

  • 조성국;윤성민;김두기;홍기증
    • 한국지진공학회논문집
    • /
    • 제19권3호
    • /
    • pp.133-143
    • /
    • 2015
  • It is very important to assure the seismic performance of equipment as well as building structures in seismic design of nuclear power plant(NPP). Seismically isolated structures may be reviewed mainly on the horizontal seismic responses. Considering the equipment installed in the NPP, the vertical earthquake responses of the structure also should be reviewed. This study has investigated the vertical seismic demand of seismically isolated structure by lead rubber bearings(LRBs). For the numerical evaluation of seismic demand of the base isolated NPP, the Korean standard nuclear power plant (APR1400) is modeled as 4 different models, which are supported by LRBs to have 4 different horizontal target periods. Two real earthquake records and artificially generated input motions have been used as inputs for earthquake analyses. For the study, the vertical floor response spectra(FRS) were generated at the major points of the structure. As a results, the vertical seismic responses of horizontally isolated structure have largely increased due to flexibility of elastomeric isolator. The vertical stiffness of the bearings are more carefully considered in the seismic design of the base-isolated NPPs which have the various equipment inside.

Generic optimization, energy analysis, and seismic response study for MSCSS with rubber bearings

  • Fan, Buqiao;Zhang, Xun'an;Abdulhadi, Mustapha;Wang, Zhihao
    • Earthquakes and Structures
    • /
    • 제19권5호
    • /
    • pp.347-359
    • /
    • 2020
  • The Mega-Sub Controlled Structure System (MSCSS), an innovative vibration passive control system for building structures, is improved by adding lead rubber bearings (LRBs) on top of the substructure. For the new system, a genetic algorithm is used to optimize the dynamic parameters and distributions of dampers and LRBs. The program uses various seismic performance indicators as optimization objectives, and corresponding results are compared. It is found that the optimization procedure for maximizing the energy dissipation ratio yields the best solutions, and optimized models have consistent seismic performances under different earthquakes. Seismic performances of optimized MSCSS models with and without LRBs, as well as the traditional Mega-Sub Structure model, are evaluated and compared under El Centro wave, Taft wave and 20 other artificial waves. In both elastic and plastic analysis, the model with LRBs shows significantly smaller story drift and horizontal acceleration than those of the other two models, and fewer plastic hinges are developed during severe earthquakes. Energy analysis also shows that LRBs installed in proper locations increase the deformation and energy dissipation of dampers, thereby significantly reduce the kinetic, potential, and hysteretic energy in the structure. However, LRBs do not have to be mounted on all the additional columns. It is also demonstrated that LRBs at unfavorable locations can decrease the energy dissipation for dampers. After LRBs are installed, the optimal damping coefficient and the optimal damping exponent of dampers are reduced to produce the best damping effect.

자동복원 및 보강 시스템과 결합된 면진받침의 지진거동과 평가 (Seismic Behavior and Estimation for Base Isolator Bearings with Self-centering and Reinforcing Systems)

  • 허종완
    • 대한토목학회논문집
    • /
    • 제35권5호
    • /
    • pp.1025-1037
    • /
    • 2015
  • 지반과 상부 구조물 사이의 경계에서 유연성이 확보된 지진동 격리 받침 시스템을 설치한 후에 전체 구조물의 고유 주기를 연장하고 구조물에 전달되는 지진 가속도를 저감하여 구조물을 보호하는 면진 설계 방식이 최근 건설 현장에서 널리 활용되고 있다. 하지만 도심지의 현대 구조물이 점차 대형화 및 고층화 되면서 기존의 면진 받침을 그대로 사용하기에는 지진 발생시 저항 능력의 부족으로 인한 전단파괴 혹은 잔류변형이 발생하여 구조물의 사용성 향상을 위한 보수 및 붕괴 위험에 따른 철거의 문제점을 발생시킨다. 따라서 본 연구에서는 기존에 주로 사용되는 면진 받침의 저항 강도와 복원성을 향상시키기 위하여 부가적인 개장 시스템을 설치하고 지진 하중에 대한 성능을 평가하고자 한다. 초탄성 형상기억합금 소재의 보강 봉을 납 적층 고무 받침에 설치한 면진 시스템을 설계하고 단자유도 스프링 모델로 모형화하여 지진 데이터를 활용하고 비선형 동적 해석을 실시하였다. 본 연구에서 제안된 면진 시스템이 성능적인 우수성을 입증하기 위하여 기존에 사용된 면진 받침과 여기에 추가로 강재 봉으로 보강된 면진 시스템과의 극한 전단 저항력, 복원성 및 잔류변형 발생 등을 해석을 통하여 비교 평가하였다. 그 결과 초탄성 형상기억합금 소재의 제어 봉으로 보강된 면진 받침이 다른 면진 받침과 비교하여 지진저항 성능에 있어서 우수함을 확인하였다.

H-말뚝을 이용한 일체식교대 교량 (Integral Bridge Using H-pile)

  • 정경자;김성환;유성근
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.241-248
    • /
    • 1999
  • The existing bridge with deck joint has many problems during construction and maintenance. To overcome these difficulties, an integral bridge, which is defined as the practice of constructing bridges without deck joints, is proposed in this study. A test bridge with 3 spans of PC beam was selected to verify the function of the bridge and is under construction. Characteristics of integral bridge are followings: $\circled1$ Flexible H-piles under the abutment are installed to accommodate thermal movements of the superstructures of bridge. $\circled2$ PC beam of the superstructure and the abutment are integrated. $\circled3$ The existing approach and relief slabs are applied to minimize the stress transfer occurred from the bridge deck to the pavement. $\circled4$ A cyclic control joint is installed between approach and relief slabs to absorb the thermal movement. $\circled5$ It is used a dual direction bearing which is cheaper than single direction bearing and has a good workability as well. It is also installed a shear block on the top of pier coping to protect the lateral movement caused by temperature change and earthquake.

  • PDF

가속 열 노화시험에 의한 탄성받침용 합성고무의 수명 예측에 관한 연구 (Accelerated Heat Aging Test for Predicting Useful Lifetime of Elastomeric Rearing)

  • 박광화;박준형;이하영;권영일
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제4권2호
    • /
    • pp.73-90
    • /
    • 2004
  • We performed the heat aging test to predict the useful lifetime of Elastomeric Bearing Chloroprene Rubber (CR) used for supporting bridge. During the test, we measured elongation that are influenced by temperature and aging time. The failure of a test piece is defined as the point at which the elongation reaches to 75% of the initial value. This failure criterion is based on KS F 4420: 1998 (Elastomeric Bearing for bridge). Through the accelerated heat aging test, we found that the Arrhenius relationship and the Weibull lifetime distribution are appropriate as the life-temperature relationship and lifetime distribution of the CR, respectively. Using the Arrhenius -Weibull model, the parameters of the model are estimated and the lifetime of the CR at use condition is predicted.

  • PDF

Seismic behavior of energy dissipation shear wall with CFST column elements

  • Su, Hao;Zhu Lihua;Wang, Yaohong;Feng, Lei;Gao, Zeyu;Guo, Yuchen;Meng, Longfei;Yuan, Hanquan
    • Steel and Composite Structures
    • /
    • 제43권1호
    • /
    • pp.55-66
    • /
    • 2022
  • To develop high-efficiency lateral force resistance components for high-rise buildings, a novel energy dissipation shear wall with concrete-filled steel tubular (CFST) column elements was proposed. An energy dissipation shear wall specimen with CFST column elements (GZSW) and an ordinary reinforced concrete shear wall (SW) were constructed, and experimented by low-cycle reversed loading. The mechanical characteristics of these two specimens, including the bearing capacity, ductility, energy dissipation, and stiffness degradation process, were analyzed. The finite-element model of the GZSW was established by ABAQUS. Based on this finite-element model, the effect of the placement of steel-plate energy dissipation connectors on the seismic performance of the shear wall was analyzed, and optimization was performed. The experiment results prove that, the GZSW exhibited a superior seismic performance in terms of bearing capacity, ductility, energy dissipation, and stiffness degradation, in comparison with the SW. The results calculated by the ABAQUS finite-elements model of GZSW corresponded well with the results of experiment, and it proved the rationality of the established finite-elements model. In addition, the optimal placement of the steel-plate energy dissipation connectors was obtained by ABAQUS.