• Title/Summary/Keyword: Row spacing

Search Result 97, Processing Time 0.03 seconds

Impingement heat transfer within 1 row of circular water jets: Part 2-Effects of nozzle to heated surface distance (1열 원형 충돌수분류군에 의한 열전달의 실험적 연구 (제2보, 노즐-전열면간 거리의 영향))

  • 엄기찬;이종수;김상필
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.1
    • /
    • pp.59-66
    • /
    • 2000
  • In a previous paper, we have examined the effects of nozzle configuration and jet to jet spacing on the heat transfer of 1 row of circular water jets. In this paper, experiments have been conducted to obtain the effects of nozzle to target plate distances on the heat transfer of 1 row of 3 jets and 1 row of 5 jets. The nozzle configurations are Cone type, Reverse cone type and Vertical circular type. Nozzle to target plate distance H was varied from 16 mm(H/D=2) to 80mm(H/D=10). For fixed value of mass flow rate and nozzle to target plate distance, larger values of average Nusselt number were obtained for the smaller jet to jet spacing. For the array of water jets, the average heat transfer was decreased slightly with increasing nozzle to target plate distance at low jet velocity of $\textrm{V}_{o}$=3 m/s. However, except for $\textrm{V}_{o}$=8 m/s of 1 row of 5 jets, it was increased with increasing nozzle to target plate distance at high jet velocity of $\textrm{V}_{o}$$\geq$6m/s. We proposed to apply the nozzle configuration of maximum average heat transfer to each nozzle to target plate distance for 1 row of 3 jets, and, it was Reverse cone type nozzle for 1 row of 5 jets(Reynolds number$\geq$36000).

  • PDF

Variations of Lateral Bearing Capacity of 2-row Micropile with Installation Conditions by Model Test (모형시험을 통한 복열 마이크로파일의 설치조건에 따른 수평 지지력 변화)

  • Hwang, Tae-Hyun;Kim, Mu-Yeun;Lee, Yeong-Saeng
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.11
    • /
    • pp.35-49
    • /
    • 2020
  • The lateral bearing capacity of the micropile depends on the installed conditions such as number, installation angle and spacing of the pile. Existing research on micropile has been limited to the evaluation of vertical bearing characteristics and suggestion of effective installation methods, and there are few studies on failure mechanisms such as failure mode. And most of the studies on the lateral bearing capacity of micropile are also on the 1-row micropile. Therefore, in this study, a model test was performed to evaluate the behavior and lateral bearing characteristics of a 2-row micropile when the installed conditions such as the installation length, angle, and spacing of the pile were different. As a result of the model test, when the installation angle is θ > 0° (Not cross installation), the lateral bearing capacity of 2-row micropile depends on the spacing of the piles, and the installation angle θ = +30° was the most effective for increasing the bearing capacity. In addition, when the installation angle is θ < 0° (Overlap installation), it depends on the spacing and angle of the pile, and the condition of installation angle θ = -15° was found to be the most effective for increasing the bearing capacity.

The Load Distribution Characteristics of Pile Group under Lateral Loading (수평력을 받는 무리말뚝의 하중분담특성)

  • Ahn, Byungchul;Oh, Sewook
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.3
    • /
    • pp.17-22
    • /
    • 2010
  • This paper analyzed the characteristics of p-multiplier and the load distribution of H-pile group installed in weathered soil under horizontal loading. The results of this study conducted in pile arrangement ($2{\times}3$, $3{\times}3$), the pile center to center spacing (2D, 4D, 6D), and soil density (relative density: 40%, 80%) were drawn as follows. As to the average horizontal loading applied to each pile in pile groups, the fewer number of piles was, the larger average horizontal resistance became. As the result of analysis on p-y curves of single piles and pile groups according to the pile distance and the soil density, as the pile spacing was increased from 2D to 6D, the interaction coefficients of pile group showed 0.85~0.94 (piles in the front row), 0.57~0.79 (piles in the middle row), and 0.60~0.71 (piles in the rear row) in the loose ground and showed 0.76~0.82 (piles in the front row), 0.58~0.73 (piles in the middle row), and 0.53~0.70 (piles in the rear row) in the dense ground. As above, the wider pile distance was, the larger interaction coefficient value was shown among piles. In addition, piles in the front row showed bigger interaction coefficients than that of piles in the middle and back row.

Performance Evaluation and Design of an Edible Fresh Corn Harvesting Machine (식용 풋옥수수 수확 시험장치 설계 및 성능평가)

  • Kang, Na Rae;Choi, Il Su;Kim, Young Keun;Choi, Yong;Yu, Seung Hwa;Woo, Jea Keun;Hyun, Chang Sik;Kim, Sung Kook
    • Journal of Drive and Control
    • /
    • v.16 no.4
    • /
    • pp.74-79
    • /
    • 2019
  • In this study, an edible fresh corn harvest testing machine was designed and manufactured. And harvesting performance was analyzed through the field test. The testing machine is of the tractor attached type. It is connected to the tractor PTO shaft to transfer power to the each part of the harvesting machine. And it harvests fresh corn by one row through the processes of cutting, stem crushing, detaching, and collecting. The performance test was performed at PTO speed (540, 750, 1050 rpm, respectively), working speed (0.1, 0.15, 0.2 m/s, respectively), and cropping cultivation (row spacing·hill spacing 70·25 cm, 70·40 cm, 90·30 cm, respectively). The performance test was repeated three times in the 15 m section. The detachment loss ratio, uncollected crop ratio, damage ratio, and harvest ratio were analyzed. As a result of the performance test, it was analyzed that the PTO speed 540 rpm, running speed of 0.1 m/s, and row spacing·hill spacing 70·40 cm were the optimal condition.

Effect of Leucaena Row Spacing and Cutting Intensity on the Growth of Leucaena and Three Associated Grasses in Thailand

  • Tudsri, S.;Kaewkunya, C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.7
    • /
    • pp.986-991
    • /
    • 2002
  • An experiment was conducted at Suwanvajokkasikit Research Station, Pakchong, Nakornratchasima, Thailand, to determine the yield and quality of three different grass cultivars intercropped with leucaena (Leucaena leucocephala). The treatments consisted of three grass cultivars (ruzi, dwarf napier and Taiwan A25) as the main plots, planted between leucaena at three row spacings (1, 2 and 4 m width) as the sub plots and leucaena cutting height (10 and 25 cm above ground levels) as sub-sub-plots. Dwarf napier consistently produced more dry matter than Taiwan A25 or ruzi and Taiwan A25 outyielded ruzi. Leucaena yield was highest in the ruzi plot and lowest in the dwarf napier plot. However, yields of grass plus leucaena were highest in the dwarf napier plot and were lowest in the ruzi plots. The difference was due mainly to the grass components. Increasing the spacing between rows of leucaena resulted in a lower leucaena yield but the reverse was true for the grasses. Cutting of leucaena at 10 cm above ground levels depressed yields of leucaena but did not affect the associated grasses. In terms of herbage quality, it was found that the crude protein of leaves and stems of the dwarf napier and Taiwan A25 were higher than that of the ruzi grass. Leucaena gave higher levels of crude protein than all grasses. The phosphorus and potassium levels of all grasses were higher than leucaena. ADF levels were higher in the grasses than in the legumes. Nutrient contents in the leaves and stems of grasses and leucaena were not affected by leucaena spacing and cutting height.

Heat Transfer Characteristics of Individual Row of Fin and Tube Heat Exchangers

  • Chang Keun-Sun;Kweon Young-Chul;Kim Young-Jae;Jeong Ji-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.2
    • /
    • pp.49-56
    • /
    • 2006
  • Heat transfer performances of individual row of two-row fin and tube heat exchangers are experimentally investigated. Tested are four heat exchangers which are geometrically identical with the exception of fin shape, slit or louver, and that the fins between the first row and the second row are connected or separated. The tube diameter and fin spacing of the heat exchangers examined are 7mm and 1.4mm, respectively. All thermal fluid measurements are made using a psychrometric calorimeter. In order to evaluate air-side heat transfer coefficients of individual rows, tube-side water flow rates of individual rows are independently controlled such that the water-side temperature drops in each row remain at $5^{\circ}C$. Frontal air velocity varies in the range from 0.7m/s to 2.5m/s. Heat transfer coefficients are presented in terms of Colburn ${\jmath}-factor$. The results show that the heat transfer coefficient of the upstream row is larger than that for the downstream row at low Reynolds numbers.

Development of a Chain Conveyor Type Row-Spacing System for Plant Factory (식물공장용 체인 컨베이어식 작물 조간 조절장치 개발)

  • Chang Yu Seob;Song Hyun Gap;Kim Dong Eok
    • Journal of Bio-Environment Control
    • /
    • v.14 no.1
    • /
    • pp.7-14
    • /
    • 2005
  • This study was conducted to develop a chain conveyor-type, row-spacing system for a plant factory. The developed system was evaluated for its practical use in growing plants. Results are intended to provide technical suggestions on the row spacing for hydroponically grown vegetables in a plant factory. The designed row-spacing system for a plant factory could be adjusted by four stages with a conveying speed range of $5.3\~15.8cm{\cdot}s^{-1}$ and with a row-space range of 10-25cm. The torque of driving shaft was measured with a torque range of 11.7-33.3 N$\cdot$m according as a trough weight changes with a range of $17\~935$ N. A measured value was $5.9\~9.8\;N{\cdot}m$ lower than a theoretical value. Travel reduction rate was shown up $1.6\~1.9\%$. The conveying time of trough was shown up 2.24 seconds in case that the designed value was 2.26 seconds. The system was evaluated to be functioning effectively according to the initial design factors in the test.

Effects of Plant Spacing on Light Environment, Yield and Quality of Burley Tobacco (Burley종의 재식거잡가 광환경, 수량 및 품종에 미치는 영향)

  • 배성국;임해건
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.26 no.2
    • /
    • pp.212-217
    • /
    • 1981
  • The evaluate the effect of plant spacing on cured leaf of burley tobacco, the row spacings divided to 90, 105, 120cm and hill spacings to 30, 35, 40cm within each row. Growth amount per plant increased with thinner row and wider hill spacing in the same planting density. Relative light intensity increased with thinner row spacing in cutters and leaf and showed the positive correlation with quality. When the planting density was equal, the wider hill spacings, the more effective in utillization of solar radiation. The more plants per l0a were, the greater yield was obtained, and in the case of 3,200 plants per 10a (the most dense planting plot) was 267kg. But, quality, total-alkaloid and total-nitrogen content decreased with dense planting. Value per 10a was highest in the plots of 90 $\times$ 40cm and $105{\times}40cm$. In conclusion the optimum density level was 2,400 to 2,700 plants per 10a and spacing of tobacco either in 105 $\times$ 35 cm or 105 $\times$ 40cm seems to be most appropriate.

  • PDF

A Study on Factors Influencing the Shear Strength of Shear Connectors (전단연결재 강도산정 영향인자에 대한 연구)

  • 여진호;임남형;강영종
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1091-1096
    • /
    • 2001
  • Generally, in a steel girder and the concrete slab act as a composite structure, the connectors must have adequate strength and stiffness. If there are no horizontal or vertical separations at the interface, the connectors are described as rigid, and complete interaction can be said to exist under these idealized circumstances. In previous study, it was considered that the strength of stud is affected by the stud diameter, height of stud and compressive strength of concrete. The differences between previous study and this study are variables, which are shank diameter of shear connector, the spacing of shear connector, the size of specimen and the row of shear connector. So this paper, as a study on the strength of shear connector with the spacing of shear connector, size of specimen (block-out size), row of shear connector and shank diameter of shear connector resulted from the push-out specimen are conducted with ABAQUS program. It is to investigate the effects of characteristics of these factors. The load-slip relations obtained from the experiments are compared with those of analyses. From these results, the trends of stress are stress estimated and compared with push-out test.

  • PDF

Development of a Robotic Transplanter for Pot-Seedlings of Plant Factory (식물공장용 포트묘 로봇 이식기 개발)

  • 류관희;김기영;류영선;한재성;신태웅
    • Journal of Biosystems Engineering
    • /
    • v.23 no.3
    • /
    • pp.277-284
    • /
    • 1998
  • This study was conducted to develop m automatic pot-seedling transplanter for plant factory. The transplanter consists of a gripper, row-spacing control device, nursing tray transfer system, growing trough transfer system, and gripper moving device. The gripper picks up pot-seedling. The gripper moving device moves the gripper between nursing tray and growing-flat. Nursing trays are moved to workspace by the nursing tray transfer system. The growing trough transfer system was developed to move growing trough to workspace. The row-spacing control device was used to adjust the distance between adjacent plants traversely. The results of this study are as follows. The transplanting capacity of the developed transplanter was 7.1 seconds per cycle or 1.18 second per pot-seedling. Successful planting was 98.9% without seedlings and 95.8% with seedlings.

  • PDF