• Title/Summary/Keyword: Routine Activity

Search Result 150, Processing Time 0.026 seconds

Suture Anchor Capsulorraphy in the Traumatic Anterior Shoulder Instability: Open Versus Arthroscopic Technique (봉합나사를 이용한 Bankart 봉합술의 관절경적 및 개방적 수술의 비교)

  • Kim Seung-Ho;Ha Kwon-Ick;Kim Sang-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.2
    • /
    • pp.157-169
    • /
    • 1999
  • Eighty-nine shoulders in eighty-eight patients with traumatic unilateral anterior shoulder instability were evaluated for Rowe and UCLA scores, recurrence, return to activity, and range of motion by an independent examiner at an average of 39 months after either arthroscopic or open Bankart repair using suture anchors. The arthroscopic technique included a minimum of 3 anchors, and a routine incorporation of capsular plication and proximal shift. Twenty­six shoulders(86.6%) out of thirty in the open Bankart repair group had excellent or good results while fifty­four(91.5%) of the fifty-nine shoulders with arthroscopic Bankart repair had excellent or good results. The arthroscopic group revealed significantly better results in the Rowe(p=.041) and UCLA scores(p=.026). Two shoulders in each group developed redislocation. There were no significant differences in the loss of external rotation and return to prior activity between the two groups(p>.05). The residual instability occurred more frequently in the group of patients with lesser anchors. Arthroscopic suture anchor capsulorraphy has results equal to or better than the open Bankart procedure.

  • PDF

Behavioral Contextualization for Extracting Occupant's ADL Patterns in Smart-home Environment (스마트 홈 환경에서의 재실자 일상생활 활동 패턴 추출을 위한 행동 컨텍스트화 프로세스에 관한 연구)

  • Lee, Bogyeong;Lee, Hyun-Soo;Park, Moonseo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.1
    • /
    • pp.21-31
    • /
    • 2018
  • The rapid increase of the elderly living alone is a critical issue in worldwide as it leads to a rapid increase of a social support costs (e.g., medical expenses) for the elderly. In early stages of dementia, the activities of daily living (ADL) including self-care tasks can be affected by abnormal patterns or behaviors and used as an evidence for the early diagnosis. However, extracting activities using non-intrusive approach is still quite challenging and the existing methods are not fully visualized to understand the behavior pattern or routine. To address these issues, this research suggests a model to extract the activities from coarse-grained data (spatio-temporal data log) and visualize the behavioral context information. Our approach shows the process of extracting and visualizing the subject's spaceactivity map presenting the context of each activity (time, room, duration, sequence, frequency). This research contributes to show a possibility of detecting subject's activities and behavioral patterns using coarse-grained data (limited to spatio-temporal information) with little infringement of personal privacy.

Comparison of Calibration Methods of $^{192}\textrm{Ir}$ Sources for High Dose Rate Brachytherapy (고선량률 근접조사치료용 이리듐-192 방사성동위원소의 교정방법 비교연구)

  • Huh Hyun Do;Park Sung Yong;Lee Rena J;Shin Dong Oh;Kwon Soo Il;Loh John J K;Choi Jinho
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.192-196
    • /
    • 2004
  • The activity of Ir-192 sources for high dose rate (HDR) Brachytherapy in Korea were measured by using the well-type chamber and using the calibration Jig with the Farmer-type ionization chamber to compare the manufacturer certificated source strength which is supplied with each new Ir-192 source. The activity of two different source models used in six hospitals were measured. The range of measured activities to the manufacturer's suggested ones was -2.40% to +3.31% for the calibration Jig and -3.12% to 0.00% for the well-type chamber system. The source strength values given by the manufacturer for the 6 sources were within ${\pm}5%$ for the two different measuring equipment. Our results demonstrate that well-type chamber as wall as Farmer-type chamber system are appropriate system for the routine source calibration procedures in HDR brachytherapy. Whenever a new source is installed to use in clinics, a source calibration should be carried out.

  • PDF

Root Dynamics of a Pine Stand at Hongcheon Determined by Two Kinds of Soil Samplers (두 가지 토양(土壤) 시료(試料) 채취기(採取器)를 이용한 홍천(洪川) 소재(所在) 소나무림(林)의 근계동태(根系動態) 분석(分析))

  • Huh, Tae-Chul;Park, Hyun
    • Journal of Korean Society of Forest Science
    • /
    • v.86 no.1
    • /
    • pp.105-111
    • /
    • 1997
  • Root dynamics of a pine stand at Hongcheon, Korea was assayed with two kinds of soil samplers which had been tentatively manufactured to renovate the routine soil sampler, Oakfield soil sampler. Root-mixed soil samples were collected on December of 1995, March, May, August and December of 1996 within each randomly selected 8 plots. The amount of roots collected by the two kinds of soil samplers were not significantly different at the 5% level, which indicated that the renovated sampler was more desirable to be used since the sampler showed efficiencies in time for collection and quantification than the routine sampler. The quantities of total root in 100g soils were 469mg on December of 1995, and 352mg, 473mg, 461mg, 522mg on the following March, May, August and December, respectively. That is, total amount of roots showed the smallest in Spring and reached maximum in early Winter, although the differences were not significant among each season. By the way, the alive roots and dead roots showed significant differences among season, the alive roots took about 90% from May to early December while they decreased down to some 65% from late December to March. The roots of Pinus densiflora S. et Z. took about 46% of total roots although the species comprised 70% of crown layer, and the ratio of fine-roots of the species were higher than that of other species. By the way, the dynamics of total roots and that of alive roots were quite different. Thus, the study for root dynamics such as fine roots which take a major role for mycorrhizae formation or nutrient uptake should not be inferred from the data of total root dynamics but be investigated in detail by dividing them into each class.

  • PDF

The Usefulness of Pleural IFN-$\gamma$ Level in Differential Diagnosis of Tuberculous Pleural Effusion and Malignant Pleural Effusion (결핵성 흉막염과 악성 흉수의 감별진단에 있어서 흉수 IFN-$\gamma$ 측정의 유용성)

  • Kim, Myung-Sun;Yang, Sung-Eun;Chi, Hyun-Sook;Kim, Woo-Sung;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.2
    • /
    • pp.280-289
    • /
    • 1998
  • Background: It is sometimes difficult to differentiate tuberculous pleural effusion from malignant pleural effusion by clinical symptoms, signs, by routine tests of pleural fluid, and by pathologic studies. And recently, it was discovered that cytokines such as IL-2, IFN-$\gamma$, TNF-$\alpha$ are elevated in tuberculous pleural fluid, and there have been several attempts to diagnose tuberculous pleural effusion by using these immunological mediators. There are several studies regarding the diagnostic value of IFN-$\gamma$, and there are two studies in Korea. But the diagnostic values of IFN-$\gamma$ in these studies were slightly lower than those in other countries. To compare the diagnostic value of IFN-$\gamma$ with those of CEA and ADA, and to determine the sensitivity and specificity of IFN-$\gamma$ in Korean, we mesured IFN-$\gamma$, CEA level and ADA activity in pleural effusions. Methods: ADA activity, IFN-$\gamma$ level and CEA level as well as cell count, differential count, and biochemical assays such as protein content and lactate dehydrogenase were measured in 40 cases of tuberculous pleuritis and 42 cases of malignant pleural effusion. Results: Tuberculous pleural fluid showed higher levels of IFN-$\gamma$ and ADA ($832.6{\pm}357.2$ pg/ml and $82.5{\pm}25.9$ U/L, respectively) than those of malignant pleural effusion ($2.6{\pm}8.0$ pg/ml and $19.2{\pm}10.9$ U/L, respectively) (p<0.01). Malignant pleural effusions showed higher median value (102.2 ng/ml) than tubercalous pleural effusions (1.8 ng/ml) (p<0.01). The sensitivities of IFN-$\gamma$, ADA, CEA were 0.97, 0.87, 0.67 and the specificities of IFN-$\gamma$, ADA, CEA were 1.0, 0.97, 1.0, respectively. There was no significant correlation between ADA activity and IFN-$\gamma$ level. Conclusion: This study showed that IFN-$\gamma$ test would be a very useful clinical test for differential diagnosis of tuberculous pleuritis and malignant pleural effusion because it is very sensitive and specific, although it is an expensive test.

  • PDF

Radiolabeling of 11C-sertraline by fast and easy loop method with [11C]CH3OTf

  • Lee, Hak Jeong;Jeong, Jae Min;Lee, Sang-Yoon;Ido, Tatsuo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.1
    • /
    • pp.32-37
    • /
    • 2017
  • Cis-(1S,4S)-4-(3,4-dichlorophenyl)-1,2,3,4-tertrahydro-N-methyl-1-naphthalenamine (sertraline) hydrochloride from among selective serotonin reuptake inhibitors (SSRIs) is a treatment of major depression. For the differential diagnosis by metabolizing serotonin in a patient with neurological disorders, the radiolabeled $^{11}C$-sertraline was developed for non-invasive positron emission tomography in living brain and use the evaluation of new drug for SSRIs. We release the results of a fast and easy radiolabeling method applied a one-step loop method with $[^{11}C]CH_3OTf$ for routine clinical applications of $^{11}C$-sertraline. 1 mg of a precursor for $^{11}C$-sertraline in 0.1 mL DMF and $5{\mu}L$ of 1N NaOH, were injected into the loop of semi-prep high-performance liquid chromatography (HPLC). $[^{11}C]CH_3OTf$ was passed through the loop at room temperature (RT). The $^{11}C$-sertraline was separated by the semi-preparative HPLC. $^{11}C$-sertraline was eluted at 28.0 min was collected and evaluated by analytical HPLC and mass spectrometer. The total radiolabeling efficiency of $^{11}C$-sertraline was $30.7{\pm}8.7%$. The specific activity was $64.8{\pm}51.4GBq/{\mu}mol$. The radiochemical and chemical purities were higher than 99%. The mass spectrum of the product showed m/z peaks at 307.1 (M+1), indicating the mass of sertraline. By the one-step loop method with $[^{11}C]CH_3OTf$, $^{11}C$-sertraline could be quickly and easily prepared for clinical application.

A Case of Glutaric Aciduria Type I with Macrocephaly (Glutaric Aciduria Type I 1례)

  • Shin, Woo Jong;Moon, Yeo Ok;Yoon, Hye Ran;Dong, Eun Sil;Ahn, Young Min
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.3
    • /
    • pp.295-301
    • /
    • 2003
  • Glutaric aciduria type 1(GA1) is an autosomal recessive disorder of the lysine, hydroxylysine and tryptophan metabolism caused by the deficiency of mitochondrial glutaryl-CoA dehydrogenase. This disease is characterized by macrocephaly at birth or shortly after birth and various neurologic symptoms. Between the first weeks and the 4-5th year of life, intercurrent illness such as viral infections, gastroenteritis, or even routine immunizations can trigger acute encephalopathy, causing injury to caudate nucleus and putamen. But intellectual functions are well preserved until late in the disease course. We report a one-month-old male infant with macrocephaly and hypotonia. In brain MRI, there was frontotemporal atrophy(widening of sylvian cistern). In metabolic investigation, there were high glutarylcarnitine level in tandem mass spectrometry and high glutarate in urine organic acid analysis, GA1 was confirmed by absent glutaryl-CoA dehydrogenase activity in fibroblast culture. He was managed with lysine free milk and carnitine and riboflavin. He developed well without a metabolic crisis. If there is macrocephaly in an infant with neuroradiologic sign of frontotemporal atrophy, GA1 should have a high priority in the differential diagnosis. Because current therapy can prevent brain degeneration in more than 90% of affected infants who are treated prospectively, recognition of this disorder before the brain has been injured is essential for treatment.

Neutrophil Apoptosis and $H_2O_2$ Release by LPS in Diabetics (내독소로 자극된 당뇨환자의 중성구에서 기획성 세포사멸과 과산화수소 분비능)

  • Seo, Ki Hyun;Na, Joo Ock;Moon, Seung Hyug;Uh, Soo Taek;Kim, Yong Hoon;Park, Choon Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.3
    • /
    • pp.250-256
    • /
    • 2004
  • Background : Bacterial infections in diabetic patients are an important cause of increased morbidity and mortality. It has been reported that bacterial infections in diabetics showed more impaired PMN functions such as reduced PMN respiratory burst and decreased microbicidal activity in inflammed tissues. Also, apoptosis(programmed cell death) is postulated to be a key mechanism for neutrophil elimination. It is very important that PMN apoptosis keeps the balance from an area of inflammation. Actuallly, as little was known about PMN apoptosis and respiratory burst in diabetes, we investigated PMN apoptosis and hydrogen peroxide production after endotoxin exposure. Methods : Peripheral venous blood samples were collected by routine venipuncture from healthy volunteers and diabetics to harvest neutrophils. We respectively measured the PMN apoptosis, the production of hydrogen peroxide, and the cell viability. Results : Normal neutrophils showed a tendency to decreased apoptosis after endotoxin treatment. In patients with diabetes, PMN apoptosis was significantly decreased compared with healthy controls. In addition, the LPS-induced neutrophils in diabetics demonstrated more decreased apoptosis. However, the production of hydrogen peroxide was not different between groups. Conclusion : These observations suggest that the decreased PMN apoptosis in diabetics with endotoxin exposure may also affect the increased susceptibility and severity of infections.

Comparison Studies of SPECT Dopamine Transporter Imaging and Noninvasive Quantification using [Tc-99m]TRODAT-1 and [I-123]IPT ([Tc-99m]TRODAT-1과 [I-123]IPT SPECT를 이용한 도파민 운반체의 영상화 및 정량분석 비교)

  • Kim, Hee-Joung;Bong, Jung-Kyun;Lee, Hee Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.10-19
    • /
    • 1998
  • The SPECT radiopharmaceuticals labeled with I-123 for dopamine transporter imaging have been used to measure dopamine transporters in patients with movement disorders. However, a cyclotron produced I-123 limits its availiability and ease of use as a radioisotope to be labeled with pharmaceuticals in routine clinical diagnostic procedures. Recently, new radiophannaceuticals for Tc-99m which has optimal characteristic for SPECT imaging have been developed to overcome the limits of using I-123. The purpose of this study was to compare the quality of [Tc-99m]TRODAT-1 with [I-123]IPT SPECT data and then to evaluate the usefulness of [Tc-99m]TRODAT-1 SPECT by using three noninvasive simplified quantitative methods. TRODAT-1 labeled with Tc-99m($15.93{\pm}0.82mCi$) and IPT labeled with I-123($6.60{\pm}0.11mCi$) were injected into five normal controls. Dynamic [Tc-99m]TRODAT-1 SPECT scans of brain were performed for 10 minutes each over 180 minnutes, and for 20 minutes at 4 hrs and 5 hrs. [I-123]IPT SPECT scans were performed for 5 minutes each over 120 minutes. Time activity curves were generated for the left basal ganglia(LBG), right basal ganglia(RBG), and occipital cortex(OCC). Dopamine transporter parameters were ohtained using (BG-OCC)/OCC, graphical method($R_V$), and area ratio method($R_A$). TRODAT-1 and IPT SPECT imaging showed high uptake at the level of the basal ganglia. (BG-OCC)/OCC ratios for TRODAT-1 and IPT were $0.80{\pm}0.14$, and $3.22{\pm}0.81$, $R_Vs$ were $0.62{\pm}0.12$, and $2.30{\pm}0.35$, and $R_As$ were $0.37{\pm}0.08$ and $1.73{\pm}0.31$, respectively. In conclusion, further improvement of [Tc-99m]TRODAT-1 imaging characteristics may be required to estimate the dopamine transporter concentrations in human brains although it shows clear BG localization.

  • PDF

Production of $^{11}C$ labeled Radiopharmaceuticals using $[^{11}C]CO_2$ Produced in the KOTRON-13 (한국형 사이클로트론(KOTRON-13)을 이용한 $[^{11}C]CO_2$ 생산과 다양한 $^{11}C$-표지 방사성의약품 생산 적용)

  • Lee, Hong Jin;Park, Jun Hyung;Moon, Byung Seok;Lee, In Won;Lee, Byung Chul;Kim, Sang Eun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.106-109
    • /
    • 2012
  • Purpose : The KOTRON-13 cyclotron was developed and installed in regional cyclotron centers to produce short-lifetime medical radioisotopes. However, this cyclotron has limited capacity to produce $^{11}C$ so far. In present study, we developed an effective $^{11}C$ target system combining with fluorine-18 target and applied to the production of various $^{11}C$ radiopharmaceuticals. Materials and Methods : To develop the optimal $^{11}C$ target system and effective its cooling system, we designed the $^{11}C$ target system by Stopping and Range of Ions in Matter (SRIM) simulation program and considered the cavity pressure during irradiation at target grid. In this investigation, we modified target materials, cavity shapes and the position of cooling system in $^{11}C$ target and then evaluated $[^{11}C]CO_2$ production at different beam currents, thickness of the target foil, oxygen content of nitrogen gas and target gas loading pressure. Also, we evaluate the production of several $^{11}C$ radiopharmaceuticals such as [$^{11}C$]PIB, [$^{11}C$]DASB, and [$^{11}C$]Clozapine. Results : $[^{11}C]CO_2$ was produced about 74 GBq for 30min irradiation at 60 ${\mu}A$ of beam current as following conditions: thickness of the target foil: 19 nm HAVAR, oxygen content of nitrogen: under 50 ppb, target gas loading pressure: 24 bar. Additionally, the cooling system was stable to produce $[^{11}C]CO_2$ at high beam current. The radiochemical yields of [$^{11}C$]PIB, [$^{11}C$]DASB, and [$^{11}C$]Clozapine showed about 26-38% with over 127 GBq/umol of specific activity. Conclusion : The carbon-11 target system in the KOTRON-13 cyclotron was successfully developed and showed stable production of $[^{11}C]CO_2$. These results showed that our $^{11}C$ target system will be compatible with other commercial system for the routine $^{11}C$ radiopharmaceuticals production in the KOTRON-13 cyclotron.

  • PDF