• 제목/요약/키워드: Round robin test

검색결과 77건 처리시간 0.028초

지반 응답 해석 Round Robin Test의 입력 지진파 및 물성에 관한 고찰 (Investigation into the Input Earthquake Motions and Properties for Round Robin Test on Ground Response Analysis)

  • 선창국;한진태;최정인;김기석;김명모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2007년 가을학술발표회
    • /
    • pp.266-292
    • /
    • 2007
  • Round Robin Test (RRT) on ground response analyses was conducted for three sites in Korea based on several site investigation data, which include borehole logs with the N values from standard penetration test (SPT) for all three sites and additionally cone tip resistance profiles for two sites. Three input earthquake motions together with the site investigation data were provided for the RRT. A total of 12 teams participating in this RRT presented the results of ground response analyses using equivalent-linear and/or nonlinear method. Each team determined input geotechnical properties by using empirical relationships and literatures based on own judgment, with the exception of the input motions. Herein, the characteristics of input motions were compared in terms of the frequency and period, and the selection of the depth to bedrock, on which the motions is impinged, was discussed considering geologic conditions in Korea. Furthermore, a variety of geotechnical properties such as shear wave velocity profiles and soil nonlinear curves were investigated with the input properties used in this RRT.

  • PDF

콘칼로리미터 연소가스 FT-IR 분석을 위한 국제표준 초안의 비교시험 결과분석 (Results of a Round-Robin Test for the Draft International Standard on FT-IR Gas Analysis of Fire Effluents from a Cone Calorimeter)

  • 최정민;박계원;정재군
    • 한국화재소방학회논문지
    • /
    • 제33권3호
    • /
    • pp.1-8
    • /
    • 2019
  • ISO TC 92에서는 콘칼로리미터의 연소가스를 FT-IR 방식의 가스분석기로 분석하기 위한 표준을 개발하고 있다. 2018년에는 표준 초안(WD 21397)의 절차에 따라 6개 기관이 참여하여 표준 초안의 반복성 및 재현성을 평가하였다. 시험대상 시료는 polymethyl methacrylate (PMMA), 경질 폴리우레탄 보드 및 PVC 장판이었고 콘칼로리미터 시험결과 중 착화시간(s), 최대 열방출률(kW·m-2), 총 방출열량(MJ·m-2) 및 유효연소열(MJ·m-2·kg-1)을, 그리고 FT-IR 가스분석결과 중 독성가스의 최대 농도(µL·L-1), 가스 발생량(g) 및 가스 수율(g·g-1)을 ISO 5725-2에 따라 통계 분석하여 정밀도를 평가하였다. 이상치(outlier)는 발견되지 않았으며 콘칼로리미터 시험의 반복성(sr/m)은 1.5%, 재현성(sR/m)은 9.8%로 나타났고 FT-IR 가스분석의 반복성은 12.9%, 재현성은 27.9%로 나타났다.

입력지진파 차이로 인한 지반응답 분산도 평가 연구 (Evaluation of Ground Response Dispersion Caused by the Difference of Input Ground Motions)

  • 김진만;류정호;권기철;심재호;김제경
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2007년 가을학술발표회
    • /
    • pp.293-304
    • /
    • 2007
  • In 2007, Round Robin Test (RRT) on ground response analyses has been conducted by the technical committee of Soil Dynamics and Geotechnical Earthquake Engineering of Korean Geotechnical Society. Total 14 teams have reported 16 different results. This paper discusses the evaluation of ground response dispersion caused by the difference of input ground motions. In order to determine the characteristics of ground response, this study analysed the peak ground acceleration, predominant period, and response spectrum of reported ground surface motions. The results suggest that ground response dispersion due to the difference of input ground motions can be significant.

  • PDF

알루미나에서의 파괴인성 측정 (Fracture Toughness Testing in Alumina)

  • 윤경진;박성길;김종집;조성재
    • 한국세라믹학회지
    • /
    • 제29권8호
    • /
    • pp.651-659
    • /
    • 1992
  • Fracture toughness of alumina was determined by IF, IS, DT, SEPB methods, and the data were inter-compared. Round robin test on IF and IS methods was also conducted under the participitation of 4∼5 domestic institutes. Fracture toughness data determined by IF, IS, DT methods were similar, while those by SEPB method were smaller. Variation of toughness data determined by IS method using 98N of indentation load was significantly small compared to those determined by any other methods. Round robin test results showed that toughness data determined by IF method at various institutes do not coincide each other, while those by IS method do well coincide. Thus, it was concluded that inter-confidence on fracture toughness data, if determined by IS method at all institute, can be established between institutes.

  • PDF

장미 정유의 기체 크로마토그래피 분석표: 중국산 쿠스이형 장미유에 대한 재현정밀도 시험 (Gas chromatographic profiles of rose essential oils: a round-robin test on oil of rose, Chinese Kushui type (Rosa sertata × Rosa rugosa))

  • 손현화;이동선
    • 분석과학
    • /
    • 제25권4호
    • /
    • pp.207-213
    • /
    • 2012
  • 이 연구는 ISO/TC54 전문위원회(Shanghai, Sep. 14-15, 2010)의 결정에 따라 국제규격 초안으로 제안된 ISO/DIS (Draft International Standard) 25157-resolution 385 중국산 쿠스이(苦水)형 장미(Rosa sertata ${\times}$ Rosa rugosa) 정유의 기체 크로마토그래피 분석표에 대한 국제 6개국 전문가 실험실간 재현정밀도 시험 (round-robin test: RRT)의 하나로 수행되었다. GC-FID로 분석할 때 비극성인 SPB-1 컬럼에서는 총 179개 성분, 중간 극성의 DB-624 컬럼에서는 165개 성분, 극성 Supelcowax-10 컬럼에서는 총 162개 성분을 분리하였다. ${\beta}$-Citronellol (41.6~46.7%)과 geraniol (9.7~11.0%) 및 nerol (3.4~4.5%)이 쿠스이형 장미 정유의 주성분이었다. SPB-1 컬럼과 DB-624 컬럼에서는 ${\beta}$-citronellol과 nerol성분 피크가 서로 분리되지 않고 중첩하였으나, Supelcowax-10 컬럼에서는 두 성분을 분리할 수 있었다. Phenethyl alcohol의 경우 정지상 극성이 커질수록 머무름 시간이 길어짐을 확인하였다. 그런데 거의 대부분의 특성 성분들의 머무름 시간은 중국측이 ISO/DIS 25157에서 제시한 것과 일치하였으나 극성 컬럼으로 분리한 phenethyl alcohol의 머무름 시간의 경우 중국측이 제시한 것 보다 큰 차이를 보였다. 동시에 불가리아산 장미(Rosa damascena Miller) 정유와 향수에 대한 기체크로마토그래피 분석표도 비교 분석하였다. 불가리아 장미 정유의 특성 아로마 성분 함량이 중국산 쿠스이형의 함량보다 더 많았다.

경질유 유량표준장치의 신뢰도 검증을 위한 측정정확도 비교 (Intercomparison of Light Oil Flow Standard System for the Reliability of Measurement Accuracy)

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제32권9호
    • /
    • pp.712-719
    • /
    • 2008
  • Light Oil Flow Standard System(LOFSS), as a national oil flow standard system, in Korea Research Institute of Standards and Science(KRISS) was developed for oil flowmeter calibration, and the expanded uncertainty of flow quantity determination was estimated within 0.04 %. In order to improve the reliability of the LOFSS measurement, a proficiency test was carried out in the flow range of 20 and $240\;m^3/h$ (Reynolds number $20,000{\sim}900,000$). A turbine flowmeter was used as a transfer package in round robin test. The water flow standard system of KRISS, the pipe prover of the national calibration and test organization and the master meter calibrator of the turbine flowmeter supplier, which used the different working fluid respectively, were compared with the turbine flowmeter measurement. The maximum difference of measurement was 0.15 % between the LOFSS and the pipe prover. The En numbers of the each system measurement were evaluated at the same Reynolds number. It was found that the En numbers were less than 1 in the comparison, which means the procedures of the uncertainty estimation of the each calibrators were reasonable and reliable.