• 제목/요약/키워드: Roughness length

검색결과 280건 처리시간 0.031초

표면거칠기 측정용 다이아몬드 촉침의 마모에 관한 연구 (A Study on the Wear of Diamond Stylus for Surface Roughness Measurement)

  • 한응교;노병옥;박두원;김종억
    • 한국정밀공학회지
    • /
    • 제8권3호
    • /
    • pp.105-113
    • /
    • 1991
  • The practicability of Ion-Sputter machining renders it possible to make diamond stylus for surface roughness measurement with micro stylus tip radius less than 2${\mu}mR$, and to measure surface roughness of fine-machined surface. In this study, we researched the wear or Ion-Sputtered stylus with 0.1${\mu}mR$ and 0.5${\mu}mR$ for micro-figure measurement and polished stylus with 0.5${\mu}mR$ according to measurement distance. As a result, we know that the case of Ion-Sputtered stylus is worn down easilier the case of polished stylus. And we know that in the evaluation of stylus wear, it is more useful method that examine the wear by measuring the variation of stylus tip radius than by evaluating the variation of Ra values.

  • PDF

조도가 후향계단 주위의 난류유동에 미치는 영향에 대한 실험적 연구 (An Experimental Study of Roughness Effects on the Turbulent Flow Downstream of a Backward-Facing Step)

  • 김병남;정명균
    • 대한기계학회논문집
    • /
    • 제15권6호
    • /
    • pp.2083-2099
    • /
    • 1991
  • 본 연구에서는 다른 실험 조건은 일정하게 유지하면서 아래 벽면의 표면조도 를 체계적으로 변화시켜 표면조도가 후향계단 뒤의 재부착 흐름 및 재발달경계층에 미 치는 영향을 조사하고자 하며 구체적인 내응은 다음과 같다. (1) 표면조도가 재부착 길이와 재발달경계층에 미치는 영향의 조사. (2) 표면조도가 평균속도와 난류량 분포 에 미치는 영향의 조사. (3) 여러 종류 표면조도 변화에 따른 재부착길이와 재발달 경 계층 회복에 미치는 영향과 결과의 상호 비교.

취성재료의 가공시 절삭날이 표면거칠기에 미치는 영향 (The Effect of Cutting Edge on the Surface Roughness In Cutting Brittle Materials)

  • 김주현
    • 한국정밀공학회지
    • /
    • 제13권1호
    • /
    • pp.53-61
    • /
    • 1996
  • A clear understanding of the surface formation mechanism due to cutting is very important to help produce a good quality surface. Much of the roughness along the length of a bar being cut in a lathe can be explained in terms of macroscopic tool shape and feed rate. However, the roughness along the direction of cutting requires a different explanation. The formation of surface roughness is a problem in flow and fracture of materials in the vicinity of the tool edge. On a microscopic scale the cutting edge is rounded because it is impossible to grind a perfectly sharp cutting edge. Even if a perfectly sharp cutting edge were obtained it would soon become dull as a result of rapid breakdown and wear of the cutting edge. A research project is proposed in which in the main object is to model the surface formation mechanism due to cutting. The tool was assumed to be dull, that is, its edge has a finite radius. In order to study the effect of the radius of cutting edge on the surface formation, tools having different cutting edges were used. For orthogonal cutting experiment, cast iron and glass were chosen as brittle materials. Plowing forces acting in the cutting edge were estimated and its effect on the surface roughness was studied by observing the machined surface using optical microscope.

  • PDF

Ti 합금의 절삭 가공특성에 관한 연구 (Study on Cutting Processing Characteristic of Ti alloy)

  • 반재삼;이경원;김규하;조규종
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.1017-1020
    • /
    • 2002
  • The pure Ti is taken annealing process for one hour at 90$0^{\circ}C$. The pure Ti is sufficient for ASTM B348 Grade2. The rolling mill roll the Ti-8Ta-3Nb(wt%) which became vacuum melting in arc furnace until the length is about 45mm and the thickness is about 6.05mm. Then it is made 6mm$\times$6mm$\times$44mm by wire cutting with EDM and it is made ∮ 6mm by rough cutting with the general purpose lathe. The machining accuracy of implant parts in the dental and medical science are decided by dimension, shpe, straightness, surface roughness. It is difficult to cut for the Ti alloy. It is caused problems of straight degree and surface roughness to the Ti alloy have many cases which length is smaller than diameter in cutting. Total 24 specimens different kind of 4 alloies are used in experiment to gain a cutting property. According to the cutting velocity, cutting depth, cutting temperature, feed and clearance angle experiments are performed. Conclusively it is expected that cutting depth of 0.5mm, feed velocity of 0.07mm/rev and cutting velocity of 80m/min could make a suitable result.

  • PDF

Deep Hole 가공시 SM55C의 절삭성에 관한 연구 (A Study on Machinability of SM55C for Deep Hole Drilling)

  • 장성규
    • 한국생산제조학회지
    • /
    • 제7권4호
    • /
    • pp.56-63
    • /
    • 1998
  • The purpose of this is to analyze experimentally how the change of cutting speed have effects on hole over size of cutting hole, surface roughness of workpiece and roundness during the deep hole machining of SM55C with solid BTA drill using BTA drilling system. Conclusion reached is as follows. (1) The diameter was expanded for 25$\mu$m at the first section and then was reduced 0$\mu$m and 15$\mu$m respectively at the 10m and 20m section comparing to the diameter of tool with respect to the variation of cutting length at 70m/min of cutting speed. 0.15mm/rev of feed. (2) It was proved that roughness was below 8.67$\mu$m for the whole section of cutting length. (3) The roundness has been below 12$\mu$m. Regarding the polygon phenomenon, it has been proved that not only uneven best at 70m/min of cutting speed. 0.15mm/rev of feed.

Monte Carlo Simulation Study: the effects of double-patterning versus single-patterning on the line-edge-roughness (LER) in FDSOI Tri-gate MOSFETs

  • Park, In Jun;Shin, Changhwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권5호
    • /
    • pp.511-515
    • /
    • 2013
  • A Monte Carlo (MC) simulation study has been done in order to investigate the effects of line-edge-roughness (LER) induced by either 1P1E (single-patterning and single-etching) or 2P2E (double-patterning and double-etching) on fully-depleted silicon-on-insulator (FDSOI) tri-gate metal-oxide-semiconductor field-effect transistors (MOSFETs). Three parameters for characterizing the LER profile [i.e., root-mean square deviation (${\sigma}$), correlation length (${\zeta}$), and fractal dimension (D)] are extracted from the image-processed scanning electron microscopy (SEM) image for each photolithography method. It is experimentally verified that two parameters (i.e., ${\sigma}$ and D) are almost the same in each case, but the correlation length in the 2P2E case is longer than that in the 1P1E case. The 2P2E-LER-induced $V_TH$ variation in FDSOI tri-gate MOSFETs is smaller than the 1P1E-LER-induced $V_TH$ variation. The total random variation in $V_TH$, however, is very dependent on the other major random variation sources, such as random dopant fluctuation (RDF) and work-function variation (WFV).

Investigation of mechanical behaviour of non-persistent jointed blocks under uniaxial compression

  • Asadizadeh, Mostafa;Moosavi, Mahdi;Hossaini, Mohammad Farouq
    • Geomechanics and Engineering
    • /
    • 제14권1호
    • /
    • pp.29-42
    • /
    • 2018
  • This paper presents the results of an empirical study in which square rock-like blocks containing two parallel pre-existing rough non-persistent joints were subjected to uniaxial compression load. The main purpose of this study was to investigate uniaxial compressive strength and deformation modulus of jointed specimens. Response Surface Method (RSM) was utilized to design experiments and investigate the effect of four joint parameters, namely joint roughness coefficient (JRC), bridge length (L), bridge angle (${\gamma}$), and joint inclination (${\theta}$). The interaction of these parameters on the uniaxial compressive strength (UCS) and deformation modulus of the blocks was investigated as well. The results indicated that an increase in joint roughness coefficient, bridge length and bridge angle increased compressive strength and deformation modulus. Moreover, increasing joint inclination decreased the two mechanical properties. The concept of 'interlocking cracks' which are mixed mode (shear-tensile cracks) was introduced. This type of cracks can happen in higher level of JRC. Initiation and propagation of this type of cracks reduces mechanical properties of sample before reaching its peak strength. The results of the Response Surface Methodology showed that the mutual interaction of the joint parameters had a significant influence on the compressive strength and deformation modulus.

STRENGTH OF GLASS FIBER REINFORCED PMMA RESIN AND SURFACE ROUGHNESS CHANGE AFTER ABRASION TEST

  • Lee, Sang-Il;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo;Yun, Suk-Dae
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.310-320
    • /
    • 2007
  • Statement of the problem. The fracture of acrylic resin dentures remains an unsolved problem. Therefore, many investigations have been performed and various approaches to strengthening acrylic resin, for example, the reinforcement of heat-cured acrylic resin using glass fibers, have been suggested over the years. But problems such as poor workability, rough surface, poor adhesion of glass fiber resin complex are not solved yet. Purpose. The aim of the present study was to investigate the effect of short glass fibers on the transverse strength of heat-polymerized denture base acrylic resin and roughness of resin complex after abrasion test. Material and methods. To avoid fiber bunching and achieve even fiber distribution, glass fiber bundles were mixed with acrylic resin powder in conventional mixer with a non-cutting blade, to produce the glass fiber($10{\mu}m$ diameter, 3mm length, silane treated) resin composite. Glass fibers were incorporated at 0%, 3%, 6% and 9% by weight. Transverse strength were measured. After abrasion test, surface roughness was evaluated and scanning electron microscope view was taken for clinical application. Results. 1. 6% and 9% incorporation of 3mm glass fibers in the acrylic resin enhanced the transverse strength of the test specimens(p<0.05). 2. Before abrasion test, incorporation of 0%, 3%, 9% glass fiber in the resin showed no dirrerence in roughness statisticaly(p>0.05). 3. After abrasion test, incorporation of 0%, 3%, 6% glass fiber in the resin showed same surface roughness value statistically(p>0.05). 4. In SEM, surface roughness increased as the percentage of the fibers increased. 5. In the areas where glass fiber bunchings are formated, a remarkably high roughness was noticed. Conclusion. 6% and 9% addition of silane-treated short glass fibers into denture base acrylic resin increased transverse strength significantly. Before and after abrasion test, incorporation of 0%, 3%, 6% glass fiber in the resin showed same surface roughness value statistically.

대체냉매 R-407C의 모세관 선정에 관한 연구 (Investigation on the selection of capillary tube for the alternative refrigerant R-407C)

  • 김용환;김창년;박영무
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.56-65
    • /
    • 1998
  • In this paper, experimental investigation of capillary tube performance for R-407C is performed. The experimental setup is made of real vapor-compression refrigerating system. In this study, mass flow rate is measured for capillary tubes of various diameter and length as inlet pressure and degree of subcooling are changed. These data are compared with the results of a numerical model. The mass flow rates of the numerical model are less than by 14% compared with the measured mass flow rates. It is found that mass flow rate and length for R-407c are less than those of R-22 under the same condition. Also based on this experimental study and the numerical model, a set of capillary tube selection charts for R-407C is constructed.

  • PDF

Investigation on the Selection of Capillary Tube for the Alternative Refrigerant R-407C

  • Kim, Chang-Nyeun;Park, Young-Moo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권1호
    • /
    • pp.40-49
    • /
    • 2000
  • The capillary tube performance for R-407C is experimentally investigated. The experimental setup is a real vapor-compression refrigerating system. Mass flow rate is measured for various diameter and length while inlet pressure and degree of subcooling are changed. These data are compared with the results of a numerical model. The mass flow rate of the numerical model is about 14% less than the measured mass flow rate. It is found that mass flow rate and length for R-407C are less than those for R-22 under the same condition. Based on this experimental study and the numerical model, a set of design charts for capillary tube of R-407C is proposed.

  • PDF