• Title/Summary/Keyword: Rotor performance

Search Result 1,501, Processing Time 0.03 seconds

A Sensorless Speed Control of Brushless DC Motor in Digital Lightening Processor using the Linear Quadratic Regulator (DLP용 BLDC 모터의 속도 센서리스 제어)

  • Yang, Iee-Woo;Kim, Young-Seok;Kim, Sang-Uk;Kim, Hyun-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1102-1103
    • /
    • 2007
  • This Paper presents a solution to control the Brushless DC Motor(BLDCM) in Digital Lightening Processor(DLP) using the Linear Quadratic Regulator(LQR). Generally, The speed of BLDCM in DLP is controlled by the lead angle control or the input voltage control using PAM(Pulse Amplitude Modulation) etc. These control methods have speed overshoot in speed control and need the long time until BLDCM reaches at the steady state. In order to improve the performance, this paper present the PI speed controller using the LQR based on vector control and the rotor position detection methods at the space vector PWM inverter. The proposed methods are proved by the experimental results

  • PDF

The developement of BLOC motor with short rating and high power density (단시간 고출력 BLDC 전동기 개발)

  • Kong, Young-Kyoung;Kim, H.C.;Song, J.W.;Kim, B.S.;Kim, C.L.;Hong, S.Y.;Choi, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.43-45
    • /
    • 1998
  • ADD has developed a special BLDCM(brushless d.c. motor) that has small size and high power density. The model of BLDCM is like that of advanced nation. Design, production and test carried out with ADD and HICO. Now the performance of BLDCM is achieved 65% of design data. Also we are concerned with adhesion of magnet in rotor for high speed.

  • PDF

Speed Sensorless Vector Control of Induction Motors Using a Minimum-order Extended Kalman Filter (최소 차수 확장 칼만 필터를 이용한 속도센서 없는 유도전동기 벡터제어)

  • Lee, Seung-Hyun;Chung, Gyo-Bum
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.171-175
    • /
    • 1998
  • This paper proposes a speed sensorless vector control of induction motor using a minimum-order EKF(extended kalman filter). Minimum-order EKF has the advantage of reducing the computational estimation cost because the stator current is not estimated. EKF does not deteriorate the performance of the overall speed control system, even though the measurements are relatively noisy. The estimated rotor speed is used for vector control and overall speed control. Computer simulations of the speed sensorless vector control are carried out to test the usefulness of the minimum-order EKF algorithm.

  • PDF

A Modeling of a Variable-damping Mount Using Magneto-Rheological Fluid (ER유체를 이용한 이방성 스퀴즈필름 댐퍼의 응답특성에 관한 연구)

  • Ahn, Young-Kong;Yang, Bo-Suk;Morishita, Shin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.256-261
    • /
    • 2000
  • Electro-Rheological(ER) fluid is applied to a controllable squeeze film damper(SFD) for stabilizing a flexible rotor system. ER fluid is a class of functional fluid whose yield stress varies according to the applied electric field strength, which is observed as viscosity variation of the fluid. In applying ER fluid to a SFD, a pair of rings of the damper can be used as electrodes. When the electrodes are divided into a horizontal pair and a vertical one, the SFD can produce damping force in each direction independently. A prototype of the directionally controllable SFD was constructed and its performance was experimentally and numerically investigated in the present work.

  • PDF

Sensorless Control Method of Single-Phase hybrid SRM (단상 하이브리드 SRM의 센서리스 제어기법)

  • Tang, Ying;Zhang, Fengge;Lee, Dong-Hee;Ahn, Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.213-214
    • /
    • 2015
  • In this paper, a novel method of sensorless control scheme is proposed to apply on a single phase hybrid SRM used in high speed operation. The proposed method utilizes beneficially permanent magnet field whose performance is motor parameter independent to estimate the rotor position. The differential value of back-EMF is used to detect its peak point when there is no current conducting in the winding. Through this approach, the adjustable turn on/off position can be achieved without prior knowledge of inductance profile which is always employed by many sensorless schemes. And this paper may offer an available method to do the sensorless control in hybrid SRM used for high speed running.

  • PDF

A Study on The characteristics based on the stauration effects of traction motor for korea High Speed Train (한국형 고속전철용 견인전동기의 포화현상에 따른 특성연구)

  • 이상우;김근웅;윤종학;한성수
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.360-367
    • /
    • 1999
  • An inverter-driven induction motor is used as the traction motor for a high speed drive system that required safety, reliabillity, performance, compact size owing to the space and weight alloted for attaching to train, etc. particularly it is possible to happen the saturation effects of flux density at constant voltage-frequency region and then increase very higher than the at lowed capacity of no-load current and temperature in any case. therefore the optimum design of core, optimum voltage-frequency ratio, adoption of high grade magnetic core have been developed and researched for preventing these problems. this paper show the saturation effects of traction rotor by measuring the induced voltage of search coil at stator teeth and presents optimum voltage-frequency ratio as well as optimum core design through the comparison with efficiency, power factor, load current and no-load current for korea high speed train.

  • PDF

SSCI Mitigation of Series-compensated DFIG Wind Power Plants with Robust Sliding Mode Controller using Feedback Linearization

  • Li, Penghan;Xiong, Linyun;Wang, Jie;Ma, Meiling;Khan, Muhammad Waseem
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.569-579
    • /
    • 2019
  • A robust controller is designed based on feedback linearization and sliding mode control to damp sub-synchronous control interaction (SSCI) in doubly fed induction generator (DFIG) wind power plants (WPPs) interfaced with the grid. A feedback-linearized sliding mode controller (FLSMC) is developed for the rotor-side converter (RSC) through feedback linearization, design of the sliding mode controller, and parameter tuning with the use of particle swarm optimization. A series-compensated 100-MW DFIG WPP is adopted in simulation to evaluate the effectiveness of the designed FLSMC at different compensation degrees and wind speeds. The performance of the designed controller in damping SSCI is compared with proportional-integral controller and conventional sub-synchronous resonance damping controller. Besides the better damping capability, the proposed FLSMC enhances robustness of the system under parameter variations.

Simulation for fault current of wind turbine generating system following transformer winding connection (변압기결선에 따른 풍력발전시스템의 고장전류에 대한 시뮬레이션)

  • An, Hae-Joon;Ro, Kyoung-Soo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.454-457
    • /
    • 2007
  • This study suggests a modeling of grid-connected wind turbine generation system that has induction generator, and aims to perform simulations for outputs by the variation of actual wind speed and for fault current of wind generation system by the transformer winding connection. This study is implemented by MARTLB & SIMULINK. The simulation shall be performed by assuming single line to ground fault generated in the system Generator power, rotor speed, terminal voltage, system voltage, and fault current shall be observed following the performance of simulation. The fault current change will be dealt through the simulation results for fault current of wind generation system following the grid-connected transformer winding connection and the simulation result by the transformer neutral ground method.

Error Aalysis of Mechanical Parts and Dynamic Balancing in A Dynamically Tuned Gyroscope (동조자이로스코프의 기계부 오차 해석 및 동적밸런싱)

  • J.O. Young;C.G. Ahn;Lee, J.M.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.2
    • /
    • pp.13-22
    • /
    • 1997
  • Strapdown inertial navigation system(SDINS) is a navigational instruments necessary to guide and con- trol a free vehicle. In this study, an error analysis of mechanical parts is carried out for manufacturing a dynamically tuned gyroscope. The errors usually come from the tolerance in machining and assembly. In the error analysis, a criterion to be considered during designing and manufacturing is proposed by quanti- tatively analyzing the effect of DTG performance by tolerances. The theory of dynamic balancing is deduced and unbalance is reduced through experiment.

  • PDF

Wind Turbine Performance for Eigen Value Change of Closed-Loop System for PI-Controller (피치제어기 폐루프 시스템의 고유치 변화에 따른 풍력발전기의 성능)

  • Kim, Jong-Hwa;Moon, Seok-Jun;Shin, Yun-Ho;Won, Moon-Cheol
    • Journal of Wind Energy
    • /
    • v.4 no.2
    • /
    • pp.17-24
    • /
    • 2013
  • Idealized PID-controlled rotor-speed error for blade pitch control of wind turbines responds as a second-order system with natural frequency and damping ratio for closed-loop system. RISO National Laboratory has recommended specific natural frequency(=0.6 rad/s) and damping ratio(=0.7) for 2 MW wind turbine. The baseline controller for 5 MW wind turbine of NREL(National Renewable Energy Laboratory) is designed based on the same values of RISO recommendation. This study investigates the effect of the natural frequency and damping ratio of the controller for NREL 5 MW wind turbine. It is confirmed that RISO recommendation shall be tuned for each wind turbine.