Wind Turbine Performance for Eigen Value Change of Closed-Loop System for PI-Controller

피치제어기 폐루프 시스템의 고유치 변화에 따른 풍력발전기의 성능

  • 김종화 (한국기계연구원, 시스템다이나믹스연구실) ;
  • 문석준 (한국기계연구원, 시스템다이나믹스연구실) ;
  • 신윤호 (한국기계연구원, 시스템다이나믹스연구실) ;
  • 원문철 (충남대학교, 메카트로닉스공학과)
  • Received : 2013.09.16
  • Accepted : 2013.12.20
  • Published : 2013.12.31

Abstract

Idealized PID-controlled rotor-speed error for blade pitch control of wind turbines responds as a second-order system with natural frequency and damping ratio for closed-loop system. RISO National Laboratory has recommended specific natural frequency(=0.6 rad/s) and damping ratio(=0.7) for 2 MW wind turbine. The baseline controller for 5 MW wind turbine of NREL(National Renewable Energy Laboratory) is designed based on the same values of RISO recommendation. This study investigates the effect of the natural frequency and damping ratio of the controller for NREL 5 MW wind turbine. It is confirmed that RISO recommendation shall be tuned for each wind turbine.

Keywords

Acknowledgement

본 연구는 미래창조과학부 산하 산업기술연구회의 지원으로 한국기계연구원에서 수행 중인 주요사업 연구과제(과제명 : 능동형 위험관리 기반기술개발)의 결과 중 일부임을 밝힙니다. 또한 2012년도 산업통산자원부 재원으로 한국에너지기술평가원의 지원을 받아 수행한 연구과제(2012T100100730)의 결과 중 일부입니다.