• Title/Summary/Keyword: Rotor Flux

Search Result 761, Processing Time 0.025 seconds

Development of Analytical Models for Switched Reluctance Machine and their Validation

  • Jayapragash, R.;Chellamuthu, C.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.990-1001
    • /
    • 2015
  • This paper presents analysis of Switched Reluctance Machine (SRM) using Geometry Based Analytical Model (GBAM), Finite Element Analysis (FEA) and Fourier Series Model (FSM) with curve fitting technique. Further a Transient Analysis (TA) technique is proposed to corroborate the analysis. The main aim of this paper is to give in depth procedure in developing a Geometry Based Analytical Model of Switched Reluctance Machine which is very accurate and simple. The GBAM is developed for the specifications obtained from the manufacturer and magnetizing characteristic of the material used for the construction. Precise values of the parameters like Magneto Motive Force (MMF), flux linkage, inductance and torque are obtained for various rotor positions taking into account the Fringing Effect (FE). The FEA model is developed using MagNet7.1.1 for the same machine geometry used in GBAM and the results are compared with GBAM. Further another analytical model called Fourier Series Model is developed to justify the accuracy of the results obtained by the methods GBAM and FEA model. A prototype of microcontroller based SRM drive system is constructed for validating the analysis and the results are reported.

Effects of Wind Generation Uncertainty and Volatility on Power System Small Signal Stability

  • Shi, Li-Bao;Kang, Li;Yao, Liang-Zhong;Qin, Shi-Yao;Wang, Rui-Ming;Zhang, Jin-Ping
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.60-70
    • /
    • 2014
  • This paper discusses the impacts of large scale grid-connected wind farm equipped with permanent magnet synchronous generator (PMSG) on power system small signal stability (SSS) incorporating wind generation uncertainty and volatility. Firstly, a practical simplified PMSG model with rotor-flux-oriented control strategy applied is derived. In modeling PMSG generator side converter, the generator-voltage-oriented control strategy is utilized to implement the decoupled control of active and reactive power output. In modeling PMSG grid side converter, the grid-voltage-oriented control strategy is applied to realize the control of DC link voltage and the reactive power regulation. Based on the Weibull distribution of wind speed, the Monte Carlo simulation technique based is carried out on the IEEE 16-generator-68-bus test system as benchmark to study the impacts of wind generation uncertainty and volatility on small signal stability. Finally, some preliminary conclusions and comments are given.

A Study on the Analysis for Ac-losses of the Field Winding considering Load Changes of High-Tc Superconducting Synchronous Motor (고온초전도동기모터의 부하변동에 따른 계자권선의 교류손실 해석에 관한 연구)

  • Yun, Yong-Su;Song, Myeong-Gon;Jang, Won-Gap;Jang, In-Bae;Hong, Gye-Won;Lee, Sang-Jin;Go, Tae-Guk
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.4
    • /
    • pp.167-173
    • /
    • 1999
  • The use of high-Tc superconducting synchronous motor in power machinery has many advantages such as reduced power dissipation, size and weight. This paper presents the ac loss simulation in the rotor having an high-Tc superconducting field winding using Ag sheathed Bi-2223. The analysis was conducted with an equivalent model of the high-Tc superconducting motor with flux damper under transition condition during which the load varies from 0 watt to 250watts and from 250watts to 500watts. The simulation results show that the transient state lasts for about 3 seconds, and the ac losses decreased exponentially from the initial value above 20mW.

  • PDF

A Strategy on Adaptive Current PWM Inverter for Induction Motor (유도 전도기용 순시전류 추종형 PWM 인버터에 관한 연구)

  • 박철우;박성준;권순재;김광태
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.2
    • /
    • pp.56-61
    • /
    • 1992
  • This paper is reported on the simulation and test results of a constant flux vector control scheme of an induction motor without any speed detecting eqiupment, in which the adaptive current PWM inverter is used. The rotor speed is estimated form stator voltage, current and parameters of motor, and control algorithm in the system is performed with by micro processor. By comparing the waveform of input current of this system with that of the case with taco-generator, good agreement is observed except small ripple component. Experimental results which are acquired at start up and during acceleration/deceleration are quite similar to those of the simulation results.

  • PDF

Vector Control of PM Motor without any Rotational Transducer PART 1 - Surface Mounted Permanent Magnet Motor (위치 검출기가 없는 영구자석 동기 전동기의 제어 PART1 - 표면부착형 영구자석 전동기)

  • Jang, Ji-Hun;Ha, Jeong-Ik;Seol, Seung-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.9
    • /
    • pp.453-458
    • /
    • 2001
  • This paper presents a new vector control algorithm of the surface mounted permanent magnet motor (SMPMM) without any rotational tranceducer. Originally, SMPMM does not have any magnetic saliency in structure, but it has a little magnetic saliency due to the saturation by the flux of the permanent magnet. Moreover, it varies according to the load conditions and the control performance of schematics using the saliency can be easily degraded. To prevent it and to improve the performance of the proposed algorithm, the saliency of a SMPMM under various load conditions is analyzed. In the proposed algorithm, the saliency or the impedance difference related to the saliency is utilized in order to estimate the position and speed of the rotor. And the high frequency signal is injected into the motor to measure the impedance difference and also to enhance the control performance of the system. The experimental results verify the performance of the proposed sensorless algorithm.

  • PDF

Thermal Reliability Analysis of a Closed Type Motor in an Axial Fan for the Large Space Ventilation (대형공간환기용 축류팬에 사용되는 밀폐형 모터의 열신뢰성 분석)

  • Lee, Tae-Gu;Hur, Jin-Huek;Moon, Sun-Ae;Yoo, Ho-Seon;Moon, Seung-Jae;Lee, Jae-Heon
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.494-499
    • /
    • 2007
  • The thermal reliability of the closed-type BLDC motor for the high speed axial fans is analyzed by a numerical method in this dissertation. Since the module and the motor part are combined in a closed case, the heat generated from a rotor in the motor and the electronic components in the PCB module can not be effectively removed to the outside. Therefore the module will easily fail by high temperature. The accelerated-life testing was accomplished to formulate the life equation and numerical method is used to predict the inside temperature of the PCB module, which is one of the life equation parameter according to the environment. The experiment for measuring the surface heat flux of the electronic components is carried out to apply the boundary condition of numerical study. When the environment temperature of BLDC motor is 21, 35 and $50^{\circ}C$, the temperature in the PCB space is predicted as 73.4, 87.5 and $102.4^{\circ}C$. Then the life time with the temperature are calculated as 2,239, 863 and 328.

  • PDF

Transient State Analysis of Network Connected to Wind Generation System (풍력발전시스템이 연계된 계통의 과도상태해석)

  • Kim, Se-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.29-35
    • /
    • 2003
  • Generator for wind power can be either synchronous or asynchronous (induction) types. Induction and synchronous generators behave in a different way when subjected to severe faults. Induction generators does not have an angle stability limit and short circuit in the neighborhood of an Induction generator causes the demagnetization of the machine when the fault is cleared, the voltage raises slowly, while the grid contributes with reactive power to the generator and the magnetic flux recovers. On the other hand in the synchronous generators the recovery of the voltage is immediate, since the excitation of the rotor angle comes from an independent circuit. This paper shows the result of the transient state analysis in the network connected to wind generation system Several case studies have been conducted to determine the effect of the clearing time of a fault on the network stability. It has been found that the critical clearing time can be as low as 61ms in the case of induction generator compared to 370ms in the case of synchronous generator.

Small-Size Induction Machine Equivalent Circuit Including Variable Stray Load and Iron Losses

  • Basic, Mateo;Vukadinovic, Dinko
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1604-1613
    • /
    • 2018
  • The paper presents the equivalent circuit of an induction machine (IM) model which includes fundamental stray load and iron losses. The corresponding equivalent resistances are introduced and modeled as variable with respect to the stator frequency and flux. Their computation does not require any tests apart from those imposed by international standards, nor does it involve IM constructional details. In addition, by the convenient positioning of these resistances within the proposed equivalent circuit, the order of the conventional IM model is preserved, thus restraining the inevitable increase of the computational complexity. In this way, a compromise is achieved between the complexity of the analyzed phenomena on the one hand and the model's practicability on the other. The proposed model has been experimentally verified using four IMs of different efficiency class and rotor cage material, all rated 1.5 kW. Besides enabling a quantitative insight into the impact of the stray load and iron losses on the operation of mains-supplied and vector-controlled IMs, the proposed model offers an opportunity to develop advanced vector control algorithms since vector control is based on the fundamental harmonic component of IM variables.

Sensorless Control of PM BLDC Motor Drive Using Third Harmonic (3고조파를 이용한 PM BLDC 전동기 구동을 위한 센서리스 제어)

  • Yoon Yong-Ho;Kim Yuen-Chung;Won Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.323-330
    • /
    • 2005
  • In order to increase reliability and reduce system cost, this paper studies particularly applicable method for sensorless PM BLDCM drive system. The waveform of the motor internal voltages(or back emf) contains a fundamental and higher order frequency harmonics. Therefore the third harmonic component is extracted from the stator phase voltage. The resulting third harmonic signal keeps a constant phase relationship with the rotor flux for any motor speed and load condition, and is practically free of noise that can be introduced by the inverter switching, making this a robust sensing method. In addition, a simple starting method and a speed estimation approach are also proposed. Some experimental results are Provided to demonstrate the validity of the proposed control method.

A Novel Sensorless Low Speed Vector Control for Synchronous Reluctance Motors Using a Block Pulse Function-Based Parameter Identification

  • Ahmad Ghaderi;Tsuyoshi Hanamoto;Teruo Tsuji
    • Journal of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.235-244
    • /
    • 2006
  • Recently, speed sensorless vector control for synchronous reluctance motors (SYRMs) has deserved attention because of its advantages. Although rotor angle calculation using flux estimation is a straightforward approach, the DC offset can cause an increasing pure integrator error in this estimator. In addition, this method is affected by parameter fluctuation. In this paper, to control the motor at the low speed region, a modified programmable cascaded low pass filter (MPCPLF) with sensorless online parameter identification based on a block pulse function is proposed. The use of the MPCLPF is suggested because in programmable, cascade low pass filters (PCLPF), which previously have been applied to induction motors, the drift increases vastly wl)en motor speed decreases. Parameter identification is also used because it does not depend on estimation accuracy and can solve parameter fluctuation effects. Thus, sensorless speed control in the low speed region is possible. The experimental system includes a PC-based control with real time Linux and an ALTERA Complex Programmable Logic Device (CPLD), to acquire data from sensors and to send commands to the system. The experimental results show the proposed method performs well, speed and angle estimation are correct. Also, parameter identification and sensorless vector control are achieved at low speed, as well as, as at high speed.