• Title/Summary/Keyword: Rotator cuff tendon

Search Result 148, Processing Time 0.029 seconds

Non-displaced Acromial Fracture diagnosed early by the Ultrasonography (초음파로 조기 진단한 비전위 견봉 골절)

  • Song, Hyun-Seok;Kim, Do-Hoon;Kim, Ryul;Choi, Nam-Yong
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.1
    • /
    • pp.46-49
    • /
    • 2012
  • Diagnoses of the acromial fractures are frequently delayed because most acromial fractures are non-displaced or minimally displaced patterns and the frequency are low. We report a case that a non-displaced acromial fracture of 74 years old male hit by the falling pipes could be diagnosed by the ultrasonography. For this case who had a pain, swelling, and the limitation of active elevation of the left shoulder after direct injury, the evaluation about the rotator cuff and the biceps long head tendon was required but the early diagnosis of the non-displaced acromial fracture was done by the easier ultrasonography before the additional studies. The ultrasonography has the advantage over the computed tomography in the aspect of evaluating the injury of the tendons of the shoulder joint.

  • PDF

Spinoglenoid Cyst Combined with SLAP Lesion Initially Missed with Ultrasonography - A Case Report - (초기 초음파 검사로 발견되지 않은 상부관절와순 전후 병변을 동반한 극관절와 낭종 - 증례보고 -)

  • Oh, Chung Hee;Oh, Joo Han;Kim, Sae Hoon;Chung, Seok Won;Kim, Joon Yub
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.1
    • /
    • pp.33-37
    • /
    • 2011
  • Spinoglenoid cyst have been reported in small series in the orthopaedic literature in association with SLAP lesion, which is one of less common causes of shoulder pain. Authors experienced one case of spinoglenoid cyst with SLAP lesion initially missed with ultrasonographic examination and physical examination. This case was confirmed by MRI, EMG and arthroscopic surgery was done. When clinicians cannot find a definite cause of shoulder pain and decreased power of rotator cuff tendon with ultrasonographic examination, they need further study such as MRI and EMG with careful physical examination. Clinicians need to aware of the limitation of ultrasonography for spinoglenoid cyst especially, (1) cyst size is small, (2) location of cyst is too deep to detect and along the scapula spine from SLAP lesion.

  • PDF

Symptomatic Mid-Substance Posterior Cruciate Ligament Calcification of the Knee Joint (증상을 동반한 슬관절의 후방십자인대 실질부에 발생한 석회화)

  • Ahn, Gil Yeong;Lee, Tae Hun;Hwang, Sung Hyun;Lee, Kyung Jin
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.93-97
    • /
    • 2021
  • Calcification in the tendon is a common disease especially in the rotator cuff. The condition can be treated conservatively in the chronic stage, but surgically in the acute stage. On the other hand there are few reports of calcification in the cruciate ligament of the knee joint, especially calcification of the posterior cruciate ligament. A 51-year-old patient with symptomatic calcification in the mid-substance of the posterior cruciate ligament was treated conservatively. The symptoms did not improve after eight months of conservative treatment, so arthroscopic surgery was performed. During arthroscopic removal of the calcification, the ligament was damaged beyond preservation. Eventually a posterior cruciate ligament reconstruction was performed. At two years after surgery, radiography confirmed no recurrence of the calcification, and the patient was free. We report this case study with a review of the relevant literature.

Arthroscopic Findings of Biceps pulley in Shoulder Pathology (견관절 병변과 관련된 이두박건 활차의 관절경적 소견)

  • Choi Chang-Hyuk;Kim Shin-Kun;Jang Woo-Chang;Lee Sung-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.136-141
    • /
    • 2002
  • Purpose : The role of biceps pulley is stabilizing sling for the long head of the biceps tendon against anterior shearing stress in the rotator interval. The purpose of this study was to classify arthroscopic findings of biceps pulley and to evaluate the relationship with shoulder pathology. Materials and Methods : From January 2002 through July 2002, we observed biceps pulley in 49 cases of shoulder pathology treated with arthroscopically. There were 22 cases of anterior instability, 12 cases of rotator cuff tear, 5 of impingement syndrome, 6 of frozen shoulder, 2 of superior labral injury and 1 of each scapulothoracic bursitis and biceps dislocation. We classified biceps pulley as four types according to the arthroscopic appearance. Type I its stretched type. type II as sling type, type III at detached sling type, and type IV as concealed type. Results : We observed stretched type in 24 cases $(49\%)$, sling type in 5 cases $(10\%)$, detached sling type in 2 cases, concealed type in 1 case, and unidentified cases in 17 cases $(35\%)$. Conclusion : Development and variation of biceps pulley may have symptomatic correlation according to the degree of shoulder motion or pathologic status.

  • PDF

Effect of Patient's Positioning on the Grade of Tendinosis and Visible Range of Infraspinatus Tendon on Ultrasound (초음파 영상에서 극하근 힘줄병의 단계와 관찰가능 범위에 환자의 자세가 미치는 영향)

  • Jee Won Chai;Joo-ho Lee;Dong Hyun Kim;Jina Park;So-Hee Oh;Su-Mi Shin
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.627-637
    • /
    • 2023
  • Purpose To investigate the effect of patient positioning on tendinosis grade, visible range, and infraspinatus tendon (IST) thickness, and to determine the feasibility of internal rotation (IR) position to assess IST on ultrasound (US). Materials and Methods This study included 52 shoulders of 48 subjects who were evaluated for IST in three different positions: neutral position (N), IR, and position with the ipsilateral hand on the contralateral shoulder (HC). Two radiologists retrospectively graded IST tendinosis from grade 0 to grade 3 and the visible range from grade 1 to grade 4. The thickness of the IST was measured by another radiologist with a short-axis view. A generalized estimating equation was used for statistical analysis. Results The tendinosis grades were higher in the HC position than in the IR position, with a cumulative odds ratio of 2.087 (p = 0.004, 95% confidence interval [CI]: 1.268-3.433). The tendinosis grades in the HC position (p = 0.370) and IR position (p = 0.146) were not significantly different from those in the N position. The overall difference in IST thickness was significant (p < 0.001), but the visible range (p = 0.530) was not significantly different according to position. Conclusion Patient positioning significantly affected the grade of tendinosis and thickness but not the visible range of the IST. The IR position is a feasible position for assessing the IST on US.

A Suture Bridge Transosseous-Equivalent Technique for Bankart Lesions with Deficient Bony Stability - Technical Note - (골안정성 결손을 가진 Bankart 병변에 대한 경 골-유사 교량형 봉합술식 - 술기 보고 -)

  • Choi, Chang-Hyuk;Kim, Shin-Kun;Chang, Il-Woong;Chae, Sung-Bum
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.2
    • /
    • pp.179-182
    • /
    • 2009
  • Purpose: Point fixation at the margin of the glenoid is a limitation of conventional arthroscopic stabilization using suture anchors, and does not afford sufficient footprint healing, especially in glenoid bone deficiency. So, we introduce an arthroscopic suture bridge transosseous-equivalent technique for bony Bankart lesions to avoid the technical disadvantage of point contact with anchor fixation and to improve mechanical stability through cross compression of the labrum. Surgical approach: The technique was adapted from the transosseous-equivalent rotator cuff repair technique using suture bridges, which improved the pressurized contact area and mean pressure between the tendon and footprint. After preparation of the glenoid bed by removal, reshaping, or mobilization of the bony lesion, two anchors (3.0 mm Biofastak, $Arthrex^{(R)}$, Naples, FL) were inserted into the superior and inferior portion of the bony Bankart lesion. Using a suture hook, medial mattress sutures were applied around the capsulolabral portion of the IGHL complex to obtain sufficient depth of glenoid coverage. A 3.5 mm pushloc anchor ($Arthrex^{(R)}$, Naples, FL) hole was made in the articular edge of the anterior glenoid rim. distal, suture bridge was applied, and proximal was inserted to mobilize the labrum in the proximal direction. This avoided the technical disadvantage of point contact with anchor fixation and decreased the level of gap formation through cross-compression of the labrum.

  • PDF

Analysis of Anatomical Conformity of Straight Antegrade Humeral Intramedullary Nail in Korean (한국인에서의 직선형 전향적 상완골 골수 내 금속정의 해부학적 적합성 분석)

  • Choi, Sung;Jee, Seungmin;Hwang, Seongmun;Shin, Dongju
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.498-503
    • /
    • 2021
  • Purpose: The aim of this study were to find ideal entry point of straight antegrade humeral intramedullary nail (SAHN) for the treatment of proximal humerus fracture in Korean and to analyze anatomical conformity using computed tomography. Materials and Methods: From May 2014 to October 2016, the study was conducted retrospectively on 74 Korean patients who had taken computed tomography on both normal and affected shoulder joint as result of shoulder injury. The mean age of the patients was 64.5 years (range, 22-95 years). Radiologic evaluation was done using multiplanar reconstruction technique of the computer tomography on normal proximal humerus. We located ideal entry point of SAHN as the point where humerus intramedullary center axis and humeral head meet. Distance between the entry point and local anatomical landmark was measured. We defined the critical distance as the distance between entry point and the most medial point of the supraspinatus attachment site. For adequate fixation and avoidance of injury to rotator cuff, critical distance should be over 8 mm according to Euler, and we defined the critical type when it is less than 8 mm. Critical distance, sex, age, height, body weight, body mass index was evaluated for the statistical significance. Results: The ideal entry point was as follows: the mean anteroposterior distance, the sagittal distance to the lateral margin of bicipital groove, was 11.5 mm and the mean mediolateral distance, the coronal distance to the lateral margin of grater tuberosity, was 20.5 mm. The mean critical distance, distance from the entry point to the just medial to insertion of the supraspinatus tendon, was 8.0 mm. Critical type with critical distance less than 8 mm was found in 41 in 74 patients (55.4%). Conclusion: The ideal entry point of SAHN in Korean was located on 11.5 mm posteriorly from the lateral margin of bicipital groove and 20.5 mm medially from lateral margin of greater tuberosity. More than half of the cases were critical type. Since critical type can possibly cause rotate cuff injury during nail insertion on entry point, surgeon should consider anatomical variance before choosing surgical option.

Accompanying Lesions and Clinical Results in the Greater Tuberosity Fracture of the Humerus with Anterior Shoulder Dislocation Under the Age of Forty (40세 이하에서 견관절 전방 탈구가 동반된 상완골 대결절 골절에서 관절내 병변 및 임상 결과)

  • Kim, Doo-Sup;Yoon, Yeo-Seung;Lee, Dong-Kyu;Park, Hyeun-Kook;Park, Jang-Hee;Shin, John
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.20-26
    • /
    • 2011
  • Purpose: The purpose of this study is to investigate the accompanying lesions of humerus greater tuberosity fracture with anterior shoulder dislocation and to analyze its clinical results. Materials and Methods: From May 2005 to November 2008, arthroscopy was performed on a total of 30 selected patients who were diagnosed with humerus greater tuberosity fracture with anterior shoulder dislocation and who were also under the age of 40. The preoperative and postoperative Constant and Rowe scores were compared. Results: There was a total of 21 cases of anteroinferior labral lesions: 2 Bankart lesions, 4 bony Bankart lesions, 4 Perthes lesions, 2 free ALPSA lesions, 3 GLAD lesions and 6 capsular tears. For other lesions, 5 rotator cuff partial tears, 3 SLAP lesions and 1 biceps tendon rupture were found. The constant scores were increased from 56.3 to 94.43 points (p=0.034), and the Rowe scores were increased from 52.56 to 91.76 points (p=0.026). Conclusion: For humerus greater tuberosity fracture with anterior shoulder dislocation, the accompanying lesion was identified and the fracture was treated using arthroscopy. Good clinical results and bone union were achieved. According to the secondary arthroscopic findings, all of the Perthes lesion, the free ALPSA lesion, the GLAD lesion and the capsular tear spontaneously healed or they did not progress to extended rupture although arthroscopic suture was not performed. Any postoperative secondary instability was not observed.