• Title/Summary/Keyword: Rotator

Search Result 846, Processing Time 0.024 seconds

Arthroscopic Reconstrucion in Megafrequency of Recurrent Anterior Shoulder Dislocations (관절경을 이용한 고 빈도 재발성 전방 견관절 탈구의 재건술)

  • Ko, Sang-Hun;You, Chong-Il;Cho, Sung-Do;Choi, Chang-Hyuk;Cheon, In-Ho;Woo, Jong-Keun;Kwag, Chang-Yul;Yun, Dong-Jin;Choe, Seong-Won
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.194-200
    • /
    • 2005
  • Purpose: To evaluate the short-term follow up outcome and the effectiveness of arthroscopic vertical shift of anteroinferior capsulolabral complex, plication of AIGHLC (anterior band of inferior glenohumeral ligament complex) and thermal capulorraphy, posteroinferior suture plication, rotator interval closure as an adjuncts in recurrent instability of megafrequency with night time dislocation. Materials & Methods: From March 1998 to February 2004, we have had 18 shoulders out of 156. All of the cases have been night time dislocation above more one time. The age were average 29.4$(21{\sim}37)$ year old. The average follow up were 21.1 $(12{\sim}45)$months We checked Rowe score and ROM at pre-operation, post-operation 6 months,1 year & last follow up period. Results: Above good results were 16 cases(88.9%). The excellent were 6 cases, good were 10, fair 1, poor 1. Conclusions: In recurrent anterior shoulder dislocation in greater than 50 frequency, arthroscopic stabilization can be an alternative technique for selected patients against open inferior capsular shift. But more long ter n follow up and large materials will be needed in the future study.

  • PDF

Arthroscopic Repair of Type II SLAP Lesion with Bioabsorbable Knotless Suture Anchor: Surgical Technique and Clinical Results (제 2형 SLAP병변에서 생체흡수성 봉합나사못을 이용한 관절경 봉함; 수술 술기와 임상 결과)

  • Lee, Chae-Chil;Kim, Sung-Jae;Hwang, Chang-Ho;Seo, Dong-Kyo;Ko, Sang-Hun
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.59-64
    • /
    • 2007
  • Purpose: The purpose of this study was to evaluate the results of bioabsorbable knotless suture anchoring for isolated type II SLAP. Materials and Methods: Fourteen patients with isolated type II SLAP underwent a surgical repair with bioabsorbable knotless anchor arthroscopically. Instability, rotator cuff tears or simple subacromial decompression were excluded. The UCLA and pain of VAS (Visual Analogue Scale), ADL (Activity of Daily Living, from the American Shoulder and Elbow Society) were evaluated and patients underwent a thorough shoulder examination at a minimum follow-up period of 2 years postoperatively. Results: At a mean of 27.1 months follow-up. The mean UCLA score improved from 14.4 pre-operatively to 31.2 on last follow-up. The mean VAS for pain was 4.9 and on last follow-up 1.0. The mean VAS for instability was 2.6 and on last follow-up 0.5. The mean ADL was 10.4 and on last follow-up 25.0. 12 patients reported their satisfaction as good to excellent and 10 of the 14 patients returned to their pre-injury level of activity (athletics) (P<0.05). Conclusion: Arthroscopic repair with bioabsorbable knotless suture anchors is an effective surgical technique for the treatment of an isolated unstable type II SLAP lesion. Overall satisfaction was only 85.7%. 1 patient had severe stiffness and 1 patient had shoulder pain.

Arthroscopic Bankart Repair: At Least 5 Years Follow-up (관절경적 Bankart 병변 봉합술: 5년 이상 추시 결과)

  • Heo, Mu-Jung;Kim, Kyung-Taek;Kim, Chul-Hong;Kang, Min-Soo;Kim, Hyeon-Jun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.2
    • /
    • pp.83-88
    • /
    • 2009
  • Purpose: To evaluate the efficacy of arthroscopic Bankart repair using metal suture anchors for treatment of chronic traumatic anterior instability of shoulder joint. Materials and Methods: 85 patients (80 male and 5 female) were included in this study. The average age was 26 (15~52) years old and the period from the first injury to operation was average 20 (6~38) months. All cases had Bankart lesion and 44 cases had Hill-Sachs lesion. The SLAP lesion was associated in 10 cases and 7 cases had partial rotator cuff tear. The average follow-up period was 89 (68~108) months. Results: Preoperative Rowe score was average 29.3 (25~50) and Rowe score improved to 86.8 (40~100), excellent in 28 cases (32.9%) and good in 46 cases (54.1%) at last follow up period and 70 cases (82.4%) had full range of motion of the shoulder. The arthroscopic revision surgery of the shoulder was performed in 3 cases (3.5%) because of postoperative re-dislocation. Conclusion: We concluded that arthroscopic Bankart repair with metal suture anchors is one of the reliable and effective method for recurrent anterior shoulder dislocation with Bankart lesion.

  • PDF

Multiple Rice Body in both Glenohumeral Joint and Subacromial & Subdeltoid Bursa Simultaneously combined with Full Thickness Cuff Tear in Rheumatoid Arthritis: Arthroscopic Treatment & MR Appearance -A Case Report- (류마토이드 관절염에서 회전근 개 전층 파열과 동반되어 견관절과 견봉하 및 삼각근하 점액낭에 동시에 발생된 다발성 미립체: 관절경적 치료 및 자기 공명 영상 소견 -1례 보고-)

  • Noh, Kyu-Cheol;Chung, Yung-Khee;Nah, Kyong-Soo;Yoo, Jung-Han
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.4 no.1
    • /
    • pp.65-69
    • /
    • 2005
  • Numerous small fibrinous rice bodies are a common finding in joints afflicted with rheumatoid arthritis(RA) or seronegative arthropathy, Subacromial and subdeltoid bursitis of the shoulder associated with multiple rice body formation is a rare occurrence. To our knowledge, this is the first report to describe the arthroscopic treatment of massive rice bodies in both glenohumeral joint and subacromial-subdeltoid bursae combined with full thickness of rotator cuff in RA. Besides, the MR appearance of subacromial-subdeltoid bursal rice bodies have been previously described in only few recent reports. Therefore, we also describe the MR appearances subacromial-subdeltoid bursae associated with multiple rice bodies in RA.

  • PDF

Clinical results of arthroscopic tenodesis of the proximal biceps tendon using by interference screw (관절경적 상완 이두근 건고정술의 임상적결과)

  • Kweon, Seok-Hyun;Chun, Churl Hong;Choi, Yoon Hong;Han, Sang Su;Kim, Jeong Woo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.1
    • /
    • pp.24-29
    • /
    • 2012
  • Purpose: To evaluate follow-up after the clinical results of arthroscopic assisted tenodesis of the proximal biceps tendon using an interference screw. Materials and Methods: We reviewed 30 cases of patients receiving tenodesis of the proximal biceps tendon between January, 2008 and January, 2010 who treated with arthroscope. The results were judged by VAS, ASES, tenderness in the biceps groove, fixation failure and the degree of deformity. Results: VAS, ASES scores increased by a statistically significant during the final observation in all patients than before surgery (p<0.05). For those with rotator cuff tear had low ASES results (p<0.05), respectively. But, tenderness in the biceps groove was 17% (5 cases), pepeye deformity and incresead BAD (biceps apex distance) were 10% (3 cases). Conclusion: Arthroscopic tenodesis of the proximal biceps tendon using an interference screw to patients with proximal lesion in their biceps tendon, can achieve good results, but it is possible to groove tenderness and popeye deformity.

  • PDF

Arthroscopic Anterior Acromioplasty for the Treatment of Chronic Impingement Syndrome of the Shoulder (관절경적 전방 견봉 성형술을 이용한 만성 견관절 충돌 증후군의 치료)

  • Park Tae-Soo;Kim Jae-Young
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.1
    • /
    • pp.49-53
    • /
    • 2000
  • Purpose : The purpose of this study was to evaluate clinical efficacy of the arthroscopic anterior acromioplasty for the treatment of chronic impingement syndrome of the shoulder. Materials and Methods : Between July 1995 and December 1997, twenty seven consecutive shoulders of 26 patients with chronic impingement syndrome of the shoulder were treated by arthroscopic anterior acromioplasty. The patients who had severe osteoarthritis of the shoulder full thickness tear of the rotator cuff, and nonoutlet impingement were excluded. The clinical results were evaluated by using UCLA shoulder rating scale. The average follow-up was 2years 3months(range, 1year 7months to 3years 1 11months). Results : Twenty three patients$(85.2\%)$ were rated as excellent or good results, while four patients$(14.8\%)$ were fair. Twenty six cases$(96.3\%)$ were satisfied with the results of the operations, while one case$(3.7\%)$, who had Parkinsonian syndrome, ossification of posterior longitudinal ligament(OPLL) of the cervical spine, and spinal stenosis of the 5th and 6th cervical spine was not satisfied. Conclusion : Arthroscopic anterior acromioplasty was an effective treatment method, especially for relief of pain, for the treatment of chronic impingement syndrome of the shoulder. If the patient has the combined lesions in the cervical spine and the shoulder, and systemic lesions, these lesions may influence the results of treatment after operation, and cause the unpredictable results.

  • PDF

Development of Simultaneous Analysis for the Multi-residual Pesticides in the Ginseng Extract using Gas Chromatography (인삼농축액에서 GC를 이용한 잔류농약 동시다성분 분석법의 개발)

  • Shin Yeong-Min;Lee Seon-Hwa;Son Yeong-Uk;Jeong Ji-Yoon;Jeoung Seoung-Wook;Park Heung-Jai;Kim Sung-Hun;Won Young-Jun;Lee Chang-Hee;Kim Woo-Seong;Hong Moo-Ki;Chae Kab-Ryong
    • Journal of Environmental Science International
    • /
    • v.15 no.1
    • /
    • pp.85-94
    • /
    • 2006
  • The simultaneous analysis of multi-residual pesticides was developed using a gas chromatography (GC) method. In this study, a simple and reliable methodology was improved to detect 154 kinds of pesticides in sinseng extract sample by using a liquid-liquid extraction procedure, open column chromagraphy and chromatographic analysis by CC electron capture detector (ECD) and GC nitrogen-phosphorus detector (NPD). The 154 kinds of pesticides were classified in 4 groups according to the chemical structure. The extraction of pesticides was experimented with $70\%$ acetone and dichloromethane/petroleum ether in order, and cleaned up via open column chromatography $(3\times30cm)$ packed with florisil $(30g,\;130^{\circ}C,\;12hrs)$. The final extract was concentrated in a rotator evaporator at $40^{\circ}C$ until dryness. Then the residue was redissolved to 2ml with acetone, and analyzed by GC-ECD and GC-NPD. The applied concentration of pesticides was over $1\~10{\mu}g/ml$. The recovery tests were ranged from $70.7\%$ to $115.2\%$ with standard deviations between 0.3 and $5.7\%$ of the standard spiked to the ginseng extract sample (Group $I\~IV$). The limit of detection (LOD) ranged from 0.001 to $0.099{\mu}g/ml$ (Group $I\~IV$). The 9 kinds of pesticides were not detected. The developed method was applied satisfactory to the determination of the 154 kinds of pesticides in the ginseng extract with good reproducibility and accuracy.

Dynamic Electromyography Analysis of Shoulder Muscles for One-handed Manual Material Handling

  • Mo, Seung-Min;Jung, Myung-Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.4
    • /
    • pp.313-326
    • /
    • 2015
  • Objective: The objective of this research is to quantitatively analyze muscle activities of arm and shoulder, according to direction in various types of one-handed manual material handling, based on surface electromyography. Background: Workers in industrial sites frequently carry out one-handed manual material handling using arm and shoulder muscles. Therefore, chronic load and accumulated fatigue occur to arm and shoulder muscles, which becomes a main cause of upper arm and shoulder musculoskeletal disorders. The shoulder muscles have widely range of motion, and complex interactions take place among various muscles including rotator cuff muscles. In this regard, research on interactions among should muscles, according to such various dynamic motions, is required. Method: Ten male subjects in their 20s participated in this research. This research considered upward, downward, leftward, rightward, forward and backward directions and fourteen muscles around arm and shoulder (biceps brachii and trapezius, etc.) as independent variables. The mean muscle activity was set as the dependent variable. This research extracted $4^{th}{\sim}7^{th}$ repetition signals according to ten times of repetitive muscle contraction, and analyzed the muscle activity concerned using the envelope detection technique. Results: The mean muscle activity of upward direction was analyzed highly statistically significant. The reason is that the effect of gravity works to arm and shoulder muscles. Also, it is conjectured that deformation of coracoacromial ligament was caused, and its contact pressure increased, due mainly to the shoulder flexion, and therefore load was analyzed high. Muscle activity was analyzed significantly low, according to concentric ballistic motion used in the concentric contraction phase by storing elastic energy in the eccentric contraction phase with a motion to bring the weight to the front of subject's body as to downward, leftward and backward directions. Because, elbow joint's flexion-extension motions mainly occurred, biceps brachii was analyzed high muscle activity as the prime mover. Conclusion: The information on the quantitative load of muscles can be applied to ergonomic work design for one-handed manual material handling to minimize muscle load. Application: This research has effectively identified muscle activity according to dynamic contraction by applying an envelope detection technique. The results can be used for ergonomic work design to minimize muscle load during the one-handed manual material handling, according to each direction. The research results are expected to be used for musculoskeletal disorder prevention and physiotherapy in the rehabilitation medical field, based on the muscle load of arm and shoulder in various directions.

The Difference in Diagnostic Performance for Detection of Supraspinatus Tendon Tears by Adding Angled Oblique Sagittal Plane Image to the Routine Shoulder MRI (고식적 견관절 자기공명영상에 추가적인 사각시상면 영상 이용 시 극상건 손상 검출 진단능 차이에 대한 고찰)

  • Kim, Ji Hee;Kim, Hyun Joo;Cha, Jang Gyu;Choi, Duk Lin;Hong, Seong Sook;Chang, Yun Woo;Hwang, Jung Hwa
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.2
    • /
    • pp.157-166
    • /
    • 2014
  • Purpose : The purpose of this study is to determine whether adding an angled oblique sagittal plane to the routine shoulder MRI improves the diagnostic performance in the evaluation of supraspinatus tendon tears with arthroscopic correlation. Materials and Methods: The study included 121 patients who had a shoulder MRI followed by arthroscopy. Two radiologists separately evaluated the supraspinatus tendon for tears on shoulder MRI either with or without the angled oblique sagittal images. Arthroscopy was used as the reference standard. The sensitivity and specificity for diagnosing supraspinatus tendon tears were calculated and compared by using McNemar test. Interobserver and intertechnique variability in the interpretation of supraspinatus tendon tears were calculated as a kappa value. Results: Adding the angled oblique sagittal images to the standard shoulder MRI showed improvement in the sensitivity for diagnosing full-thickness supraspinatus tendon tears and also in the sensitivity, specificity and accuracy for the detection of partial-thickness tears. However, there was no statistically significant difference in all of them between with and without the angled set. Interobserver agreement was substantial to almost perfect and intertechnique agreement was moderate. Conclusion: Adding an angled oblique sagittal plane image to the routine shoulder MRI showed no significantly different diagnostic performance in detecting the partial- and full-thickness supraspinatus tendon tears, compared to MRI without angled oblique sagittal plane.

Development of Rotation Invariant Real-Time Multiple Face-Detection Engine (회전변화에 무관한 실시간 다중 얼굴 검출 엔진 개발)

  • Han, Dong-Il;Choi, Jong-Ho;Yoo, Seong-Joon;Oh, Se-Chang;Cho, Jae-Il
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.4
    • /
    • pp.116-128
    • /
    • 2011
  • In this paper, we propose the structure of a high-performance face-detection engine that responds well to facial rotating changes using rotation transformation which minimize the required memory usage compared to the previous face-detection engine. The validity of the proposed structure has been verified through the implementation of FPGA. For high performance face detection, the MCT (Modified Census Transform) method, which is robust against lighting change, was used. The Adaboost learning algorithm was used for creating optimized learning data. And the rotation transformation method was added to maintain effectiveness against face rotating changes. The proposed hardware structure was composed of Color Space Converter, Noise Filter, Memory Controller Interface, Image Rotator, Image Scaler, MCT(Modified Census Transform), Candidate Detector / Confidence Mapper, Position Resizer, Data Grouper, Overlay Processor / Color Overlay Processor. The face detection engine was tested using a Virtex5 LX330 FPGA board, a QVGA grade CMOS camera, and an LCD Display. It was verified that the engine demonstrated excellent performance in diverse real life environments and in a face detection standard database. As a result, a high performance real time face detection engine that can conduct real time processing at speeds of at least 60 frames per second, which is effective against lighting changes and face rotating changes and can detect 32 faces in diverse sizes simultaneously, was developed.