• Title/Summary/Keyword: Rotational flow

Search Result 522, Processing Time 0.024 seconds

주기적으로 회전진동하는 원주 후류의 유동구조에 관한 실험적 연구 (Experimental Study on Flow Structure of Wake Behind a Rotationally Oscillating Circular Cylinder)

  • 이정엽;이상준
    • 대한기계학회논문집B
    • /
    • 제30권4호
    • /
    • pp.298-305
    • /
    • 2006
  • The flow around a circular cylinder which oscillates rotationally with a relatively high forcing frequency has been investigated experimentally using flow visualization and hot-wire measurements. Dominant parameters are Reynolds number (Re), oscillation amplitude $({\theta}_A)$, and frequency ratio $F_R=f_f/f_n$, where $f_f$ is the forcing frequency and $f_n$ is the natural frequency of vortex shedding. Experiments were carried out under the conditions of $Re=4.14{\times}10^3,\;{\theta}_A={\pi}/6$, and $0{\leq}F_R{\leq}2$. The effect of frequency ratio $F_R$ on the flow structure of wake was evaluated by measuring wake velocity profile and spectral analysis of hot-wire signal. Depending on the frequency ratio $F_R$, the cylinder wake has 5 different flow regimes. The vortex formation length and vortex shedding frequency are changed significantly before and after the lock-on regime. The drag coefficient was reduced under the condition of $F_R<1.0$ and the maximum drag reduction is about 33% at $F_R=0.8$. However, the drag is increased as $F_R$ increases beyond $F_R=1.0$. This active flow control method can be effective in aerodynamic applications, if the forcing parameters are selected optimally.

전동차용 DRIVING GEAR UNIT의 윤활유량 선정에 관한 연구 (Study on Flow Lubrication Selection of Driving Gear Unit for EMU)

  • 김경한;이태훈;김학수;서영진;고형근
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.132-137
    • /
    • 2011
  • 철도차량의 고속화, 경량화와 함께 승객의 안전성을 보다 더 높이기 위한 많은 연구가 진행 되고 있다. 철도차량의 안전성을 높이기 위해서는 주행성능을 안정시키는 것이 무엇보다 중요하며, 드라이빙기어 내부의 윤활유량을 최적화하는 것은 주행성능 확보에 필수적이다. 본 연구에서는 전동차용 Driving Gear Unit의 회전 방향에 따라 저속 Gear 치면을 통해 Splash 되는 드라이빙기어 Casing내의 윤활유 유동 변화를 ANASYS CFD 프로그램과 전산유체해석 기법을 사용하여 구현 하였으며, 해석 내역을 토대로 유사 구동 조건에 대한 무부하 실증 시험을 실시하여 해석의 적합성 및 윤활유량 선정과 드라이빙기어의 안전성에 대해 고찰하였다.

  • PDF

회전속도가 상반각 정익을 적용한 천음속 축류 압축기 성능에 미치는 영향 (Effects of Rotational Speed on the Performance in a Transonic Axial Compressor with a Dihedral Stator)

  • 황동하;최민석;백제현
    • 한국유체기계학회 논문집
    • /
    • 제17권5호
    • /
    • pp.27-36
    • /
    • 2014
  • This paper presents a numerical investigation of the effect of the rotation speed on the performance in a transonic axial compressor with the dihedral stator. Four stator geometries with different stacking line variables were tested in the flow simulations over the whole operating range. It was found that a large shroud loss at the rotor outlet and the subsequent shroud corner separation in the stator passage occurred at low mass flow rate with the 100 % design speed. The hub dihedral stator could suppress the shroud loss region and consequently improve the stall margin. In case of the 70 % design speed condition as the mass flow rate decreased, it was seen that the high loss region was placed at the midspan of the rotor passage. The dihedral stator slightly affected the local diffusion factor, but the performance of the compressor was not changed.

터보펌프 인듀서의 수치해석을 통한 성능예측 (Numerical Study on the Hydrodynamic Performance Prediction of Turbopump Inducers)

  • 최창호;이기수;김진한;양수석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.625-630
    • /
    • 2001
  • The inducers in liquid-rocket engines are to increase the inlet pressure of the pump to avoid any malfunction due to cavitation. Inducers are typically designed to be operated with some amount of cavitation for the compactness of the turbopump system. Also, inducers are designed to produce low headrise to prevent the decrease of the overall pump efficiency due to the low efficiency of inducers. In the present paper, a computational study on the hydrodynamic behavior of the inducer for the rocket-engine turbopump are presented including the effect of the mass flow rate under the constant rotational speed. As the mass flow rate is decreased, the inducer showed better performance with strong back flows which may have deleterious effects upon the anti-cavitation ability. But the adopted inducer showed very low headrise with high volume flow rates, which may be caused by the small passage area near the trailing edge. The modified version of the present inducer is proposed and numerically evaluated, which in turn showed better results.

  • PDF

터보펌프 Cavitation 성능시험기 개발 및 성능시험에 관한 연구 (Development of Turbopump Cavitation Performance Test Facility and the Test of Inducer Performance)

  • 손동기;김춘택;윤민수;차봉준;김진한;양수석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.619-624
    • /
    • 2001
  • A performance test facility for turbopump inducer cavitation was developed and the inducer cavitation performance tests were performed. Major components of the performance test facility are driving unit, test section, piping, water tank, and data acquisition and control system. The maximum of testing capability of this facility are as follows: flow rate - 30kg/s; pressure - 13 bar; rotational speed 10,000rpm. This cavitation test facility is characterized by the booster pump installed at the outlet of the pump that extends the flow rate range, and by the pressure control system that makes the line pressure down to vapor pressure. The vacuum pump is used for removing the dissolved air in the water as well as the line pressure. Performance tests were carried out and preliminary data of test model inducer were obtained. The cavitation performance test and cavitation bubble flow visualization were also made. This facility is originally designed for turbopump inducer performance test and cavitation test. However it can be applied to the pump impeller performance test in the future with little modification.

  • PDF

초전도 케이블 냉각유로에서의 압력강하 특성 (Pressure Drop Characteristics on HTS Power Cables with LN2 Flow)

  • 고득용;염한길;이관수
    • 설비공학논문집
    • /
    • 제18권1호
    • /
    • pp.81-86
    • /
    • 2006
  • High temperature superconducting (HTS) power cable requires forced sub-cooled LN2 flow cooling. Liquid nitrogen is circulated by a pump and cooled back by cooling system. Typical operating temperature range is expected to be between 65 K and 77 K. The HTS power cable needs sufficient cooling to overcome its low temperature heat load. For successful cooling, the hydraulic characteristics of the HTS power cable must be well investigated to design the cables. Especially, the pressure drop in the cable is an important design parameter, because the pressure drop decides the length of the cable, size of the coolant circulation pump and circulation pressure, etc. This paper describes measurement and investigation of the pressure drop of the cooling system. In order to reduce the total pressure drop of the cooling system, the flow rate of liquid nitrogen must be controlled by rotational speed of the circulation pump.

CFD에 의한 500kW급 수평축 풍력발전용 터빈의 성능평가 및 유동해석에 관한 연구 (A Study of Performance Estimate and Flow Analysis of the 500 kW Horizontal-Axis Wind Turbine by CFD)

  • 김유택;김범석;김정환;남청도;이영호
    • 한국유체기계학회 논문집
    • /
    • 제5권4호
    • /
    • pp.32-39
    • /
    • 2002
  • The purpose of this 3-D numerical simulation is to calculate and examine the complex 3-D stall phenomena on the rotor blade and wake distribution of the wind turbine. The flow characteristics of 500kW Horizontal Axis Wind Turbine (HAWT) are compared with the calculated 3-D stall phenomena and wake distribution. We used the CFX-TASCflow to predict flow and power characteristics of the wind turbine. The CFD results are somewhat consistent with the BEM (Blade Element Momentum) results. And, the rotational speed becomes faster, the 3-D stall region becomes smaller. Moreover, the pressure distribution on the pressure side that directly gets the incoming wind grows high as it goes toward the tip of the blade. The pressure distribution on the blade's suction side tells us that the pressure becomes low in the leading edge of the airfoil as it moves from the hub to the tip. However, we are not able to precisely predict on the power coefficient of the rotor blade at the position of generating complex 3-D stall region.

자율무인잠수정의 수중 도킹을 위한 비쥬얼 서보 제어 알고리즘 (A Visual Servo Algorithm for Underwater Docking of an Autonomous Underwater Vehicle (AUV))

  • 이판묵;전봉환;이종무
    • 한국해양공학회지
    • /
    • 제17권1호
    • /
    • pp.1-7
    • /
    • 2003
  • Autonomous underwater vehicles (AUVs) are unmanned, underwater vessels that are used to investigate sea environments in the study of oceanography. Docking systems are required to increase the capability of the AUVs, to recharge the batteries, and to transmit data in real time for specific underwater works, such as repented jobs at sea bed. This paper presents a visual :em control system used to dock an AUV into an underwater station. A camera mounted at the now center of the AUV is used to guide the AUV into dock. To create the visual servo control system, this paper derives an optical flow model of a camera, where the projected motions of the image plane are described with the rotational and translational velocities of the AUV. This paper combines the optical flow equation of the camera with the AUVs equation of motion, and deriver a state equation for the visual servo AUV. Further, this paper proposes a discrete-time MIMO controller, minimizing a cost function. The control inputs of the AUV are automatically generated with the projected target position on the CCD plane of the camera and with the AUVs motion. To demonstrate the effectiveness of the modeling and the control law of the visual servo AUV simulations on docking the AUV to a target station are performed with the 6-dof nonlinear equations of REMUS AUV and a CCD camera.

3중 열선 프로브를 이용한 Gun식 가스버너의 3차원 유동장 측정 (Measurement of the Three-Dimensional Flow Fields of a Gun-Type Gas Burner Using Triple Hot-Wire Probe)

  • 김장권;정규조
    • 동력기계공학회지
    • /
    • 제10권3호
    • /
    • pp.23-31
    • /
    • 2006
  • Mean velocities and turbulent characteristics in the three-dimensional flow fields of a gun-type gas burner were measured by using triple hot-wire probe (T-probe) in order to compare them with the results already presented by X-type hot-wire probe (X-probe). Vectors obtained by the measurement of two kinds of probes in the horizontal plane and in the cross section respectively show more or less difference in magnitude each other, but comparatively similar shape in overall distribution. Axial mean velocity component along the centerline shows that the value by T-probe is about ten times smaller than that by X-probe above the range of X/R=3. Also, the axial component of turbulent intensity along the centerline appears the biggest difference between the two probes. Moreover, axial mean velocity component, axial turbulent intensity component and rotational along the Y-directional distance show a big difference between slits and swirl vanes. On the whole, the values by T-probe appear smaller than those by X-probe.

  • PDF

CFX 코드에 의한 산업용 원심펌프 성능해석에 관한 연구 (A Study on the Performance Analysis of an Industrial Centrifugal Pump Using CFX Code)

  • 김명석;김범석;김진구;박권하;이영호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.174-175
    • /
    • 2005
  • The purpose of this study is focused on the analysis of 3D complex flow and performance characteristics of a centrifugal pump with volute casing. The numerical analysis was performed by commercial code CFX-10 according to the variation of flow rate, which is changing from 5.847$m^3$/min to 6.865$m^3$/min. The rated rotational speed of close type impeller is 1750rpm. Turbulence model, k-${\omega}$ SST was selected to guaranty more accurate prediction of flow separation. The ICEM-CFD 10, reliable grid generation software was also adapted to secure high quality grid generation necessary for the reliable numerical simulation. The experimental results such as static head, brake horse power and efficiency of the centrifugal pump were compared with the numerical analysis results. The simulated results are good agreement with the experimental results less 5$%$ error.

  • PDF