• Title/Summary/Keyword: Rotational Speed

Search Result 1,122, Processing Time 0.02 seconds

COMPARISON OF SCREW-IN EFFECT FOR SEVERAL NICKEL-TITANIUM ROTARY INSTRUMENTS IN SIMULATED RESIN ROOT CANAL (모형 레진 근관에서 수종의 전동 니켈-티타늄 파일에 대한 screw-in effect 비교)

  • Ha, Jung-Hong;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.4
    • /
    • pp.267-272
    • /
    • 2010
  • Screw-in effect is one of the unintended phenomena that occurs during the root canal preparation with nickel-titanium rotary files. The aim of this study was to compare the screw-in effect among various nickel-titanium rotary file systems. Six different nickel-titanium rotary instruments (ISO 20/.06 taper) were used: $K3^{TM}$ (SybronEndo, Glendora, CA, USA), $M_{two}$ (VDW GmbH, Munchen, Germany), NRT with safe-tip and with active tip (Mani Inc., Shioya-gun, Japan), ProFile$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland). For ProTaper$^{(R)}$, S2 was selected because it has size 20. Root canal instrumentations were done in sixty simulated single-curved resin root canals with a rotational speed of 300 rpm and single pecking motion. A special device was designed to measure the force of screw-in effect. A dynamometer of the device recorded the screw-in force during simulated canal preparation and the recorded data was stored in a computer with designed software (LCV-USE-VS, Lorenz Messtechnik GmbH, Alfdorf, Germany). The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. P value of less than 0.05 was regarded significant. ProTaper$^{(R)}$ produced significantly more screw-in effects than any other instruments in the study (p < 0.001). $K3^{TM}$ produced significantly more screw-in effects than $M_{two}$, and ProFile$^{(R)}$ (p < 0.001). There was no significant difference among $M_{two}$, NRT, and ProFile$^{(R)}$ (p > 0.05), and between NRT with active tip and NRT with safe one neither (p > 0.05). From the result of the present study, it was concluded, therefore, that there seems significant differences of screw-in effect among the tested nickel-titanium rotary instruments. The radial lands and rake angle of nickel-titanium rotary instrument might be the cause of the difference.

A Study on Effective Information Delivery of Digital Sign Systems in General Hospitals (종합병원 디지털 정보안내사인의 효과적 정보전달을 위한 연구)

  • Kim, Hwa Sil;Paik, Jin Kyung
    • Korea Science and Art Forum
    • /
    • v.19
    • /
    • pp.281-292
    • /
    • 2015
  • For this study, I conducted a survey investigating current situation, user preference, and field experiment. Hospitals utilizing digital sign systems at least five years were selected, which are connected with visual elements (layout, typo, color) used in waiting areas and elements of the systems (time, video time line). The results obtained from the field survey showed that digital sign systems used the color of typo and background contrasted to one another to increase explicitness and to ensure easy understanding of contents. In addition, the Gothic typo with relatively high legibility was adopted. Time and video timeline, which characterize digital sign systems, showed the advertising screens of the hospitals and the guidance of medical treatment at regular intervals. Moreover, survey results on user satisfaction showed that a majority of respondents indicated they had difficulty in understanding digital information conveyed from digital sign systems due to time setting for rotational speed or the small size of typo although most of the users had previous experience with digital sign systems. The highest proportion of respondents (n=86, 86%) answered that information related to medical departments was what they sought most frequently and that this kind of information should be importantly considered in digital sign systems. For the experiment, new samples with restructured contents of current digital sign systems were created and tested while keeping its design unchanged as well as applying these new samples. Study participants were in their 20s through 50s. When the size of typo was larger under the same conditions for all age groups, study participants found the desired information approximately 3.5 seconds faster. In addition, those in their 20-30s and 40-50s showed the time difference of 4.7 seconds for small typo and 6 seconds for large typo, which suggested that there was a difference by age in the amount of time taken in the experiment to find the desired information from the rotating digital sign system regardless of age and the size of typo.