• 제목/요약/키워드: Rotation tip

검색결과 132건 처리시간 0.04초

덕트 종횡비가 회전덕트 내 압력강하에 미치는 영향 (Effect of Duct Aspect Ratios on Pressure Drop in a Rotating Two-Pass Duct)

  • 김경민;이동현;조형희
    • 대한기계학회논문집B
    • /
    • 제30권6호
    • /
    • pp.505-513
    • /
    • 2006
  • The pressure drop characteristics in a rotating two-pass duct with rib turbulators are investigated in the present study. Three ducts of different aspect ratios (W/H=0.5, 1.0 and 2.0) are employed with a fixed hydraulic diameter ($D_h$) of 26.7 mm. $90^{\circ}$-rib turbulators with $1.5mm{\times}1.5mm$ cross-section are attached on the leading and trailing surfaces. The pitch-to-rib height ratio (p/e) is 1.0. The distance between the tip of the divider and the outer wall of the duct is 1.0 W. The thickness of divider wall is 6.0 mm o. 0.225 $D_h$. The Reynolds number (Re) based on the hydraulic diameter is kept constant at 10,000 and the .elation number (Ro) is varied from 0.0 to 0.2. As duct aspect ratio increases, high friction factor ratios show in overall regions. The reason is that the rib height-to-duct height ratio (e/H) increases, but the divider wall thickness-to-duct width ($t_d/W$) decreases. The rotation of duct produces pressure drop discrepancy between the leading and trailing surfaces. However, the pressure drop discrepancy of the high duct aspect ratio (AR=2.0) is smaller than that of the low duct aspect ratio (AR=0.5) due to the decrement of duct hight (H).

덕트의 유로 최적화를 통한 소음저감 연구 (Study on Noise Reduction by Optimizations of In-line Duct Flow)

  • 한재오;이수영;모진용;이재권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.803-808
    • /
    • 2006
  • This paper was a study about noise reduction through flow stabilization in duel using experimental method and numerical analysis at the same time. To determine the fan's type three kinds of fans(axial fan, centrifugal fan, and axial fan with centrifugal type) was examined to investigate the suitability for duct. As a result, under the equal number of rotation 2000 RPM, performance of an axial fan with centrifugal type was the most superior by 55dBA at 4.3CMM among other fans. After this, analyzed the results of the numerical analysis to find out the optimum design of pitch angle such as $0^{\circ},\;10^{\circ},\;15^{\circ}\;and\;20^{\circ}$. The intensity of turbulence was low when pitch angle was $15^{\circ}$ and air volume became peak by 5.08 CMM. It was observed that axis component of velocity increased gradually when pitch angle increased from $0^{\circ}\;to\;20^{\circ}$. Finally, designed the shapes of D/S(Down Stream) in duct that agreed inlet angle($\delta$) of stationary blades with pitch angle($\beta$) of axial fan with centrifugal type and derived flow to duct medial, and changed the shape of motor-mount to reduce occurance of unstable vortex in tip of impeller, and embodied noise reduction and improvement of air flow rate through flow stabilization.

  • PDF

고주파 절제술을 위한 심장전극도자 원격 제어 로봇 플랫폼의 개발 (Development of a Cardiac Catheter Remote Control Robot Platform for Radiofrequency Ablation Intervention)

  • 박준우;송승준;이정찬;최혁;이정주;최재순
    • 전기학회논문지
    • /
    • 제60권7호
    • /
    • pp.1417-1426
    • /
    • 2011
  • Radiofrequency ablation through cardiac catheterization is one of minimally invasive intervention procedures used in drug resistant arrhythmia treatment. To facilitate more accurate and precise catheter navigation, systems for robotic cardiac catheter navigation have been developed and commercialized. The authors have been developing a novel robotic catheter navigation system. The system is a network-based master-slave configuration 3-DOF (Degree-Of-Freedom) robotic manipulator for operation with conventional cardiac ablation catheter. The catheter manipulation motion is composed of the translation (forward/backward) and the roll movements of the catheter and knob rotation for the catheter tip articulation. The master manipulator comprises an operator handle compartment for the knob and the roll movement input, and a base platform for the translation movement input. The slave manipulator implements a robotic catheter platform in which conventional cardiac catheter is mounted and the 3-DOF motions of the catheter are controlled. The system software that runs on a realtime OS based PC, implements the master-slave motion synchronization control in the robot system. The master-slave motion synchronization performance tested with step, sinusoidal and arbitrarily varying motion commands showed satisfactory results with acceptable level of steady state error. The developed system will be further improved through evaluation of safety and performance in in vitro and in vivo tests.

Modified toe pulp fillet flap coverage: Better wound healing and satisfactory length preservation

  • Baek, Sang Oon;Suh, Hyo Wan;Lee, Jun Yong
    • Archives of Plastic Surgery
    • /
    • 제45권1호
    • /
    • pp.62-68
    • /
    • 2018
  • Background Amputation is commonly performed for toe necrosis secondary to peripheral vascular diseases, such as diabetes mellitus. When amputating a necrotic toe, preservation of the bony structure is important for preventing the collapse of adjacent digits into the amputated space. However, in the popular terminal Syme's amputation technique, partial amputation of the distal phalanx could cause increased tension on the wound margin. Herein, we introduce a new way to resect sufficient bony structure while maintaining the normal length, based on a morphological analysis of the toes. Methods Unlike the pulp of the finger in the distal phalanx, the toe has abundant teardrop-shaped pulp tissue. The ratio of the vertical length to the longitudinal length in the distal phalanx was compared between the toes and fingers. Amputation was performed at the proximal interphalangeal joint level. Then, a mobilizable pulp flap was rotated $90^{\circ}$ cephalad to replace the distal soft tissue defect. This modified toe fillet flap was performed in 5 patients. Results The toe pulp was found to have a vertically oriented morphology compared to that of the fingers, enabling length preservation through cephalad rotation. All defects were successfully covered without marginal ischemia. Conclusions While conventional toe fillet flap coverage focuses on the principle of length preservation as the first priority, our modified method takes both wound healing and length into account. The fattiest part of the pulp is advanced to the toe tip, providing a cushioning effect and enough length to substitute for phalangeal bone loss. Our modified method led to satisfactory functional and aesthetic outcomes.

Diagonal Tension Failure Model for RC Slender Beams without Shear Reinforcement Based on Kinematical Conditions (I) - Development

  • 유영민
    • 한국해양공학회지
    • /
    • 제21권6호
    • /
    • pp.7-15
    • /
    • 2007
  • A mechanical model was developed to predict the behavior of point-loaded RC slender beams (a/d > 2.5) without stirrups. It is commonly accepted by most researchers that a diagonal tension crack plays a predominant role in the failure mode of these beams, but the failure mechanism of these members is still debatable. In this paper, it was assumed that diagonal tension failure was triggered by the concrete cover splitting due to the dowel action at the initial location of diagonal tension cracks, which propagate from flexural cracks. When concrete cover splitting occurred, the shape of a diagonal tension crack was simultaneously developed, which can be determined from the principal tensile stress trajectory. This fictitious crack rotates onto the crack tip with load increase. During the rotation, all forces acting on the crack (i.e, dowel force of longitudinal bars, vertical component of concrete tensile force, shear force by aggregate interlock, shear force in compression zone) were calculated by considering the kinematical conditions such as crack width or sliding. These forces except for the shear force in the compression zone were uncoupled with respect to crack width and sliding by the proposed constitutive relations for friction along the crack. Uncoupling the shear forces along the crack was aimed at distinguishing each force from the total shear force and clarifying the failure mechanism of RC slender beams without stirrups. In addition, a proposed method deriving the dowel force of longitudinal bars made it possible to predict the secondary shear failure. The proposed model can be used to predict not only the entire behavior of point-loaded RC slender shear beams, but also the ultimate shear strength. The experiments used to validate the proposed model are reported in a companion paper.

A practical approach to nasal reconstruction in Asian patients

  • Koh, In Suk;Sun, Hook
    • 대한두개안면성형외과학회지
    • /
    • 제22권5호
    • /
    • pp.268-275
    • /
    • 2021
  • Background: The study aimed to evaluate nasal reconstruction techniques customized for Asians. The currently available nasal reconstruction guidelines are based on Caucasian patients, and their applicability is limited in Asian patients due to differences in anatomical and structural features. Methods: A retrospective analysis was performed of the medical records of 76 patients who underwent nasal reconstruction at a single center between January 2010 and June 2020. A comprehensive evaluation was conducted of patients' baseline demographics and clinical characteristics, including age, sex, medical history, defect size and location, reconstructive procedure, pathological diagnosis, postoperative complications, and recurrence. Results: In 59 cases (77%), nasal defects resulted from tumor ablation, and the remaining 17 cases involved post-traumatic (20%) and infection-induced (3%) tissue damage. The most common defect location was the alae, followed by the sidewalls, tip, and dorsum. Forehead flaps were the most commonly used reconstructive technique, followed by nasolabial advancement flaps, rotation flaps, and skin grafts. Each procedure was applied considering aspects of structural anatomy and healing physiology specific to Asians. Complications included nasal deformity, hypertrophic scarring, secondary infection, and partial flap necrosis, but no cases required additional surgical procedures. Tumors recurred in two cases, but tumor recurrence did not significantly affect flap integrity. Conclusion: Nasal reconstruction techniques applied considering Asians' facial features resulted in fewer postoperative complications and higher patient satisfaction than the approaches that are currently in widespread use. Therefore, this study is expected to serve as an essential reference for establishing treatment guidelines for nasal reconstruction in Asians.

혼합치열기 전치부 반대교합 아동에서 $F{\ddot{r}}ankel$ functional regulator III의 치료효과 (TREATMENT EFFECTS OF $F{\ddot{R}}ANKEL$ FUNCTIONAL REGULATOR III IN MIXED DENTITION CHILDREN WITH ANTERIOR CROSSBITE)

  • 박정아;양규호;최남기;김선미
    • 대한소아치과학회지
    • /
    • 제35권4호
    • /
    • pp.652-661
    • /
    • 2008
  • 본 연구는 혼합치열기 전치부 반대교합 어린이를 대상으로 FR III가 치아와 골격의 성장에 미치는 효과를 평가하고자 하였다. FR III로 처치한 전치부 반대교합을 지닌 30명의 아동(평균나이 $7.9{\pm}1.1$세 : 평균 치료기간 $1.5{\pm}0.8$년)을 대상으 로 치료 전후의 측모 두부방사선 사진을 분석하여 다음과 같은 결과를 얻었다. 1. 상악에 대한 FR III의 골격적인 효과는 상악의 하방이동이며, 전방이동은 대조군과 유의한 차이를 보이지 않았다. 2. 하악에 미치는 FR III의 골격적인 효과는 하악의 후하방이동과 SNB의 감소이다. 3. 치아에 대한 FR III의 효과는 하악 전치 첨부의 후방이동과 수평피개의 증가였다. 이상의 결과로 단기간의 FR III 치료는 상악골의 전방이동 촉진효과는 미미하며 상악골의 하방이동, 하악골의 후하방 회전, 수평피개 증가효과가 있음을 알 수 있었다.

  • PDF

SHN490강종의 보-기둥 접합부 형태에 따른 실험적 연구 (Test Results on the Type of Beam-to-Column Connection using SHN490 Steel)

  • 김소영;변상민;이호;신경재
    • 한국강구조학회 논문집
    • /
    • 제27권3호
    • /
    • pp.311-321
    • /
    • 2015
  • 본 연구는 중 저층 건축물에 적용된 강재의 보-기둥 접합부에 따른 내진성능을 규명하기 위한 실험적 연구이다. 실험체는 보-기둥 접합부의 보 플랜지와 웨브의 접합형태에 따라 분류하여 총 5가지를 제작하였다. 실험체는 웨브와 플랜지 모두 용접한 접합부(SHN-W-W)와 웨브는 용접하고 플랜지는 고력볼트 접합한 접합부(SHN-W-B)와 웨브는 고력볼트 접합하고 플랜지는 용접접합한 접합부(SHN-B-W)와 웨브와 플랜지 모두 고력볼트 접합한 접합부(SHN-B-B)와 보 단부에 엔드플레이트를 이용하여 접합한 접합부(SHN-EP)이다. 실험은 KBC2009에서 제시하는 반복재하인증실험으로 층간변위각(${\theta}$)을 제어하기 위한 변위 제어방식으로 실시하였다. 실험으로부터 각 시험체의 하중-회전각 곡선을 나타내었으며, 접합부의 최종 파괴형상을 요약하였다. 접합부는 강성과 강도의 관점에서 강접합과 반강접합으로 분류하였으며 내진성능평가를 위한 에너지소산능력을 비교하였다.

헬리컬 터빈의 설계인자에 따른 성능 연구 (Parametric Numerical Study on the Performance of Helical Tidal Stream Turbines)

  • 한준선;최다혜;현범수;김문찬;이신형;송무석
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제14권2호
    • /
    • pp.114-120
    • /
    • 2011
  • 조류발전용 다리우스 터빈의 변형된 형태인 헬리컬 터빈의 설계 인자 변화에 따른 성능을 수치해석으로 살펴보았다. 헬리컬 터빈은 수직축 다리우스 터빈을 회전축을 중심으로 상부와 하부를 비틀리게 함으로써 다리우스 터빈의 일반적인 취약점인 초기구동불량과 진동문제를 개선하기 위해 고안된 형태이다. 본 논문에서는 헬리컬 터빈의 비틀림각(Twisting Angle)과 직경대비 높이를 변화시키며 수치해석을 수행하였고, 결과를 바탕으로 최적의 구조를 제안하였다. 3차원 비정상 난류유동해석을 위하여 FLUENT의 RANS방정식과 k-${\omega}$ SST 난류모델을, 격자계 모델링을 위하여 GAMBIT을 이용하였다. 헬리컬 터빈은 적절한 비틀림각에서 양호한 발전효율을 보장하면서 진동을 유발하는 회전력 변화의 진폭을 최소화 할 수 있음을 확인하였고, 효율의 최대가 확보되는 터빈의 최소 높이를 발견하였다.

관입형 현장 전단파 측정장치의 개발 및 적용 (Development and Application of Penetration Type Field Shear Wave Apparatus)

  • 이종섭;이창호;윤형구;이우진;김형섭
    • 한국지반공학회논문집
    • /
    • 제22권12호
    • /
    • pp.67-76
    • /
    • 2006
  • 준설 매립된 연약지반이나 해성 점토의 전단강성 평가는 시료 교란의 영향으로 많은 어려움이 있다. 본 연구는 기존의 현장 전단파 시험들의 몇가지 제약 조건을 극복한 새로운 현장 전단파 시험 장치를 개발하고 적용성에 대하여 기술한 것이다. 장치 설계 고려사항은 교란효과, 트랜서듀서 간의 전기적 간섭, 케이블 사이의 전자기 커플링, 자체음향 차단, 전단파의 이동 간격 유지, 트랜서듀서의 회전, 프레임(frame)을 통한 파의 직접적 전달, 그리고 트랜서듀서와 케이블의 보호를 포함한다. 이들 고려사항은 현장과 실내실험을 통하여 지속적으로 개선되었다. 현장 전단파 속도는, 어떠한 역산기법 없이, 전단파의 이동거리와 이동시간으로부터 직접 계산되었다 개발된 현장 전단파 프로브는 깊이 30m까지 적용되었다. 실험결과 현장 전단파 프로브를 이용하여 모래와 점토지반에서 매우 세밀한 전단파 프로파일을 산정할 수 있었다. 또한 실험부지에서 수행된 콘관입실험결과와도 좋은 상관관계를 나타내었다. 본 논문에서 제시된 현장 전단파 프로브는 연약지반의 동적 특성 평가를 위한 현장 전단파 속도 측정에 매우 효과적인 장치임 보여준다.