• Title/Summary/Keyword: Rotation performance

Search Result 1,258, Processing Time 0.029 seconds

A Study on the Current Measurement Using birefringence Fiber (복굴절 광섬유를 이용한 전류측정에 관한 연구)

  • Jang Nam-Young;Choi Pyung-Suk;Eun Jae-Jeong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.6 no.2
    • /
    • pp.59-66
    • /
    • 2005
  • Accuracy of current measurement in fiber optic current sensor(FOCS), especially, unidirectional polarimetric fiber optic current sensor(PFOCS) is affected by the environment perturbations such as acoustic vibrations changes to the sensing fiber, and intrinsic perturbations such as the bending fiber that the sensing fiber wound around a current carrying wire. The perturbations affect the birefringence properties of sensing fiber in sensor head and cause false current readings. Thus, using compensation technique, reciprocal PFOCS, for unidirectional PFOCS the perturbations are suppressed. In this paper, we carried out the numerical analysis of performance in reciprocal PFOCS including the degree of polarization error, and false current of environmental and intrinsic perturbations on the sensing fiber. Also, we compared the effect of mirror with the faraday rotation mirror(FRM) in reciprocal PFOCS configuration. And the different optical source's wavelengths, 633nm and 1300nm is used. In the results, at 633nm, using mirror and FRM, the degree of polarization error is calculated to $2.3\%$ and $0.0196\%$, respectively. At $1300{\cal}nm$ using mirror and FRM the degree of polarization error is calculated to $9.97\%$ and $0.0196\%$, respectively. Also, compared with false current, the results is calculated to $9.82{\times}10^{-9}A$ and $1.4{\times}10^{-17}A$, respectively, and show that the reciprocal PFOCS is more robust configuration than unidiretionnal PFOCS for environmental and intrinsic perturbations.

  • PDF

An Experimental Study on Characteristics of Cooler by Oil Pressure for Decreasing Heat Load in Cold Storage (냉동창고 내 열부하 감소를 위한 유압 구동식 냉각기의 특성에 관한 실험적 연구)

  • Kim, Jae-Dol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1116-1122
    • /
    • 2009
  • As a result of this study, we reached the following conclusions. With appropriate setting of oil pressure and flow rate, it operated same rotation speed with existing cooler by electrical transmission. In initial operation, a temperature of a cold storage is lower rapidly. As an internal temperature of a cold storage is lower, a decreasing rate of temperature is lower. As a result of comparing the both type, the cooler of oil pressure type showed the following results. The decreasing rate of temperature was more faster and shorter operating time was more shorter than existing cooler of electric type. The actual case of a cold storage, the cooler of oil pressure type can prevent quality deterioration and decrease power consumption. As an internal temperature of a cold storage is lower, power consumption increased rapidly, the oil pressure type showed lower power consumption. COP of two of these types decreased continuously as the internal temperature of a cold storage being reach setting temperature, and that of oil pressure type showed higher amount about 25%. As a setting temperature is lower, the number of refrigerator's operating times are less and operating time is longer, so power consumption is increased in the maintenance of a cold storage's internal temperature, power consumption of hydraulic type showed lower amount about 21~25% in two of these types.

Synthesis and Characterization of Non-precious Metal Co-PANI-C Catalysts for Polymer Electrolyte Membrane Fuel Cell Cathodes (고분자 전해질 연료전지 캐소드용 코발트-폴리아닐린-탄소로 구성된 비귀금속 촉매의 제조 및 특성 평가)

  • Choi, Jong-Ho
    • Journal of the Korean Electrochemical Society
    • /
    • v.16 no.1
    • /
    • pp.52-58
    • /
    • 2013
  • In order to overcome the cost issue for commercialization of polymer electrolyte membrane fuel cell (PEMFC), this research was conducted for replacing platinum cathode catalyst with non-precious metal catalyst. The non-precious metal catalyst (Co-PANI-C) was synthesized by the simple reduction method with polyaniline (PANI), carbon black, and cobalt precursor without any heat treatment. Characterization of new Co-PANI-C composite catalysts was done by the measurement of X-ray diffraction (XRD) and thermogravimetric analysis (TGA) for structure analysis and performed by rotating disk electrode (RDE) and rotating ring disk electrode (RRDE) for electrochemical analysis. As a result, Co-PANI-C catalyst showed 60 mV lower on-set potential for oxygen reduction reaction (ORR) than Pt/C catalyst, but the overall reduction current of Co-PANI-C catalysts by ORR was still smaller than that of Pt/C. In addition, the ORR behavior of Co-PANI-C catalysts depending on the rotation speed of electrode and the stability of Co-PANI-C catalyst under potential cycling and the performance of fuel cell conditions are also discussed.

Derivation of Nacelle Transfer Function Using LiDAR Measurement (라이다(LiDAR) 측정을 이용한 나셀전달함수의 유도)

  • Kim, Hyun-Goo;Kang, Yong-Heack;Yun, Chang-Yeol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.9
    • /
    • pp.929-936
    • /
    • 2015
  • Nacelle anemometers are mounted on wind-turbine nacelles behind blade roots to measure the free-stream wind speed projected onto the wind turbine for control purposes. However, nacelle anemometers measure the transformed wind speed that is due to the wake effect caused by the blades' rotation and the nacelle geometry, etc. In this paper, we derive the Nacelle Transfer Function (NTF) to calibrate the nacelle wind speed to the free-stream wind speed, as required to carry out the performance test of wind turbines according to the IEC 61400-12-2 Wind-Turbine Standard. For the reference free-stream wind data, we use the Light Detection And Ranging (LiDAR) measurement at the Shinan wind power plant located on the Bigeumdo Island shoreline. To improve the simple linear regression NTF, we derive the multiple nonlinear regression NTF. The standard error of the wind speed was found to have decreased by a factor of 9.4, whereas the mean of the power-output residual distribution decreased by 6.5 when the 2-parameter NTF was used instead of the 1-parameter NTF.

Reversed Lateral Load Tests on RC Frames Retrofitted with BRB and FRP (좌굴방지가새와 FRP로 보강된 RC골조의 반복 횡하중 실험)

  • Lee, Han-Seon;Lee, Kyung-Bo;Hwang, Seong-Jun;Cho, Chang-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.5
    • /
    • pp.683-692
    • /
    • 2011
  • In piloti-type low-rise RC residential buildings, severe damages have been usually concentrated at piloti stories under the earthquake. In this study, a piloti story was retrofitted by installation of buckling-restrained braces (BRB's) to increase strength and stiffness of piloti story and by application of fiber reinforced polymer (FRP) sheet on columns to avoid the brittle shear and axial failure of columns. To verify this retrofit performance, reversed cyclic lateral load tests were performed on 1:5 scale bare and retrofitted frames. The test results showed that yield strength (43.2 kN) appeared to be significantly larger than design value (30 kN) due to the increase of strength in the compression side, but the stiffness value (11.6 kN/mm) turned out to be approximately one-half of the design value (24.2 kN/mm). The reasons for this difference in stiffness were due to slippage at joint between the frame and the BRB's, displacement and rotation at footing. The energy absorption capacity of the retrofitted frame was 7.5 times larger than that of the bare frame. The change of the number of load cells under the footing from 2 to 1 reduced lateral stiffness from 11.6 kN/mm to 6 kN/mm, which was only three times larger than that of the bare frame (2.1 kN/mm).

A Real-time Hand Pose Recognition Method with Hidden Finger Prediction (은닉된 손가락 예측이 가능한 실시간 손 포즈 인식 방법)

  • Na, Min-Young;Choi, Jae-In;Kim, Tae-Young
    • Journal of Korea Game Society
    • /
    • v.12 no.5
    • /
    • pp.79-88
    • /
    • 2012
  • In this paper, we present a real-time hand pose recognition method to provide an intuitive user interface through hand poses or movements without a keyboard and a mouse. For this, the areas of right and left hands are segmented from the depth camera image, and noise removal is performed. Then, the rotation angle and the centroid point of each hand area are calculated. Subsequently, a circle is expanded at regular intervals from a centroid point of the hand to detect joint points and end points of the finger by obtaining the midway points of the hand boundary crossing. Lastly, the matching between the hand information calculated previously and the hand model of previous frame is performed, and the hand model is recognized to update the hand model for the next frame. This method enables users to predict the hidden fingers through the hand model information of the previous frame using temporal coherence in consecutive frames. As a result of the experiment on various hand poses with the hidden fingers using both hands, the accuracy showed over 95% and the performance indicated over 32 fps. The proposed method can be used as a contactless input interface in presentation, advertisement, education, and game applications.

Experimental Study of Adoption of Alternative Refrigerant for Avionic Equipment Cooling System (항공전자기기용 냉각시스템의 대체냉매 적용에 관한 실험적 연구)

  • Kang, Hoon;Jung, Jongho;Jung, Minwoo;Chi, Yongnam;Yoo, Yongseon;Choi, Heeju;Byeon, Youngman;Kim, Youngjin;Oh, Kwangyoon;Kim, Yongchan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.431-439
    • /
    • 2013
  • A cooling system is adopted to control the thermal load from the avionic equipments in an aircraft for stable operation. In this study, an avionic cooling system was designed and manufactured by adopting a vapor compression cycle with a closed-loop air-circulation system to investigate the operating characteristics of an alternative refrigerant. The performance characteristics of a cooling system adopting R236fa as an alternative refrigerant were experimentally determined by varying the refrigerant charging amount, expansion valve opening, and compressor rotation speed. The experimental results were analyzed and compared with those of a cooling system adopting R124 as a refrigerant. The possibility of the adoption of R236fa as an alternative refrigerant was verified, and design solutions were suggested to improve the system efficiency.

Modelling Pasture-based Automatic Milking System Herds: The Impact of Large Herd on Milk Yield and Economics

  • Islam, M.R.;Clark, C.E.F.;Garcia, S.C.;Kerrisk, K.L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.7
    • /
    • pp.1044-1052
    • /
    • 2015
  • The aim of this modelling study was to investigate the effect of large herd size (and land areas) on walking distances and milking interval (MI), and their impact on milk yield and economic penalties when 50% of the total diets were provided from home grown feed either as pasture or grazeable complementary forage rotation (CFR) in an automatic milking system (AMS). Twelve scenarios consisting of 3 AMS herds (400, 600, 800 cows), 2 levels of pasture utilisation (current AMS utilisation of 15.0 t dry matter [DM]/ha, termed as 'moderate'; optimum pasture utilisation of 19.7 t DM/ha, termed as 'high') and 2 rates of incorporation of grazeable complementary forage system (CFS: 0, 30%; CFS = 65% farm is CFR and 35% of farm is pasture) were investigated. Walking distances, energy loss due to walking, MI, reduction in milk yield and income loss were calculated for each treatment based on information available in the literature. With moderate pasture utilisation and 0% CFR, increasing the herd size from 400 to 800 cows resulted in an increase in total walking distances between the parlour and the paddock from 3.5 to 6.3 km. Consequently, MI increased from 15.2 to 16.4 h with increased herd size from 400 to 800 cows. High pasture utilisation (allowing for an increased stocking density) reduced the total walking distances up to 1 km, thus reduced the MI by up to 0.5 h compared to the moderate pasture, 800 cow herd combination. The high pasture utilisation combined with 30% of the farm in CFR in the farm reduced the total walking distances by up to 1.7 km and MI by up to 0.8 h compared to the moderate pasture and 800 cow herd combination. For moderate pasture utilisation, increasing the herd size from 400 to 800 cows resulted in more dramatic milk yield penalty as yield increasing from c.f. 2.6 and 5.1 kg/cow/d respectively, which incurred a loss of up to $AU 1.9/cow/d. Milk yield losses of 0.61 kg and 0.25 kg for every km increase in total walking distance (voluntary return trip from parlour to paddock) and every one hour increase in MI, respectively. The high pasture utilisation combined with 30% of the farm in CFR in the farm increased milk yield by up to 1.5 kg/cow/d, thereby reducing loss by up to $0.5/cow/d (c.f. the moderate pasture and 800 cow herd scenario). Thus, it was concluded that the successful integration of grazeable CFS with pasture has the potential to improve financial performance compared to the pasture only, large herd, AMS.

Analytical and Experimental Study of an Unstiffened Extended End-Plate Connection (반복하중을 받는 비보강 확장 단부판 접합부의 해석 및 실험적 연구)

  • Kim, Hee Dong;Yang, Jae Guen;Pae, Da Sol
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.6
    • /
    • pp.439-448
    • /
    • 2016
  • Extended end-plate connections(EEPC) are a type of connection applied in Pre-Engineered Building structures comprising beam-column connections of steel structures or tapered members. Extended end-plate connections(EEPC) show different behavioral characteristics owing to the influence of plate thickness, gauge distance of high strength bolt, diameter of high strength bolt frame, and the number of high strength bolts. In the USA and Europe, extended end-plate connections(EEPC) are applied in beam-column connections of steel structures in various forms; however, these are not widely applied in structures in Korea.This can be attributed to the fact that the proposal of design strength types for extended end-plate connections(EEPC), proposal of connection specifications, evaluation of seismic performance, and are not being performed appropriately. Therefore, the purpose of this study is to provide basic data for the domestic application of Unstiffened extended endplate connections. To realize this, nonlinear finite element analysis was conducted on a 12-mm thick Unstiffened extended endplate connections.

A Descriptive Study on Job satisfaction and its Related Factors for Clinical Nurses in Goneral Hospital (일 대학병원 간호사의 직업만족도와 그에 관련된 요인 조사연구)

  • 김조자;박지원
    • Journal of Korean Academy of Nursing
    • /
    • v.18 no.1
    • /
    • pp.5-18
    • /
    • 1988
  • Herzberg and his associates concluded from their findings that job satisfaction consisted on two independent dimension ; the first dimension was related to job satisfaction, the second to job dissatisfaction. According to the Herzberg theory, the satisfiers are related to the nature of the work itself and the rewards that flow directly from the performance of that work. The dissatisfaction factors are associated with the individual's relation to the context or environment in which he works. The purpose of this study was to investigate selected factors which result in job satisfaction / dissatisfaction of nurses employed in general hospital. In a study of this nature, it is important that the population be as homogenous as possible in order to reduce the effects of the different environments and backgrounds on job satisfaction. A job satisfaction questionnaire developed by Slabitt et als. was used for this study. It contains 45 statements and utilizes a Likert type scale of 5. Participants were asked to select response which were congruent with their perceptions of the item. It was decided to conduct the study in one general hospital in Seoul. A sample of 505 clinical nurses were selected to participate in this study. The results of this study were as follows ; 1. The overall mean score for the 45 five-point scales of job satisfaction items was 2.945, showing that the subjects of this study were neither satisfied nor dissatisfied. 2. To identify the specific job related factors that result in Job satisfaction / dissatisfaction, the 45 items of job satisfaction were divided into 6 areas and the mean scores and % of agreement were compared. The specific job related factor that resulted in job satisfaction was the job status and those that resulted in job dissatisfaction were salaries, task requirements and organization requirements. But the areas of autonomy and interaction did not belong to either side of the specific job related factors. 3. To identify the relationship between the job satisfaction and the subject's general characteristic, data was analyzed using the t-test and the Pearson correlation coefficient. It was found that the relationship between the job satisfaction and the request for rotation and intention to remain on the job were statistically significant at .05 level, but the relationship between the job satisfaction and age, work experience, and educational background were nor statistically significant at the .05 level.

  • PDF