• Title/Summary/Keyword: Rotation motion

Search Result 1,106, Processing Time 0.027 seconds

The Influence of the Glenohumeral Rotation on the Scapulothoracic Motion (관절과 상완 관절의 회전운동이 견갑흉곽 운동에 미치는 영향)

  • Seo Joong-Bae;Choi Eui-Seong;Won Choong-Hee;Kim Yong-Min;Lee Ho-Seung;Kim Eung-Rok
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.2
    • /
    • pp.186-192
    • /
    • 1998
  • This study was performed to evaluate the influences of the passive glenohumeral rotation on the scapulothoracic motion. We took anteroposterior radiograms of the right shoulders including the thoracic vertebrae with supine position in 10 normal male adults, at 0 degree abduction, 45 degrees abduction and 90 degrees abduction in scapular plane and in neutral rotation, maximal internal rotation and maximal external rotation in each abduction view. The scapulothoracic motion was measured as the distances between the vertical line drawn from the spinous process of the 7th cervical vertebra and the inferior and superior angles of the right scapula respectively. At 0 degree abduction, the distances were not changed in internal rotation relative to neutral rotation, but decreased significantly in external rotation, that is, the scapula shifts medially on external rotation. At 45 degrees abduction, the distances were increased significantly only in internal rotation, that is, the scapula shifts laterally on internal rotation. At 90 degrees abduction, the scapula rotated laterally on internal rotation and medially on external rotation. In conclusion, when a physician examines the rotation of the shoulder joint, he cannot exclude the scapulothoracic motion just by examining the patient with supine position. And we concluded that the rotatory movement of the shoulder is not solely contributed to the glenohumeral motion.

  • PDF

A Study on the Rotation Accuracy According to Unbalance Variation of High Precision Spindle Unit for Machine Tool (고정밀 회전체의 불평형 변동에 따른 회전정밀도 영향에 관한 연구)

  • Kim, Sang-Hwa;Kim, Byung-Ha;Jin, Yong-Gyoo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.3
    • /
    • pp.174-181
    • /
    • 2012
  • The spindle unit is a core part in high precision machine tool. Rotation accuracy of spindle unit is needed for high dignity cutting and improving the performance of machine tool. However, there are many factors to effect to rotational error motion(rotation accuracy). This study studied how rotational error motion is variation when unbalance amount is variation. Rotation accuracy of initial spindle unit is decided depending on parts and assembly such as bearing. When it is rotation, vibration and noise is appeared depending on volume of unbalance amount, so it works to decrease unbalance amount. The purpose of the study tests that unbalance amount how much effects to initial rotation condition. The result of the study shows that accuracy of parts and assembly is highly necessary to reach high rotation accuracy and unbalance amount hardly effects to initial rotation accuracy. However, it shorten spindle's life because vibration and noise is increasing by increasing unbalance amount and we can expect situation that rotation accuracy is falling by long time operation.

Shoulder and Hip Joint Range of Motion in Normal Adults (정상 성인의 견, 고관절 가동범위에 대한 조사)

  • Ham, Yong-Woon
    • The Journal of Korean Physical Therapy
    • /
    • v.3 no.1
    • /
    • pp.97-108
    • /
    • 1991
  • The purpose of this article is to know the standard figures of joint range of motion, in conjuction with age and sen, for normal adults. The results of assessment and analysis io shoulder and hip joint range of motion are as follows : 1) The average shoulder joint range of motion in normal adults are $160.5^{\circ}$ in flexion, $53.5^{\circ}$ in extension, $159.3^{\circ}$ in adduction, $62.3^{\circ}$ in internal rotation, $83.9^{\circ}$ in external rotation, The average hip joint range of motions are $116.8^{\circ}$ in flexion, $16.1^{\circ}$ in extension, $41.1^{\circ}$ in abduction, $33.8^{\circ}$ in abduction, $40.0^{\circ}$ in interne rotation, $41.2^{\circ}$ in external rotation. 2) There is no significant difference in shoulder and hip joint range of motion between male and female (p>0.05). 3) As to the inter-relation in age and range of motion, the left flexion and extension, internal rotation and right extension in shoulder joint is decreased gradually with increasing age, and left flexion (knee flexion, knee extension) and right flexion (knee extension) in hip joint is decreased with increasing age (p<0.01). 4) Relating to age and sex, the twenties male shows highest range of motion in shoulder and hip joint, with .the fifties female shows, lowest range of motion.

  • PDF

Shoulder Range of Motion in Postmastectomy Patients (유방암 절제술 후 환자의 어깨관절 가동범위 조사)

  • Eom, Ae-Yong;Lee, Eun-Ok
    • Asian Oncology Nursing
    • /
    • v.4 no.1
    • /
    • pp.62-70
    • /
    • 2004
  • The purpose of this study was to use as a basic data to develop suitable nursing intervention program and decide an appropriate intervention time after assessing shoulder range of motion in postmastectomy from 2 weeks to 3 month. 147 patients are chosen as study subject among patients who were in recovery of 2weeks, 1month, 2months and 3 months after surgical operation which is modified radical mastectomy. Data were collected at oncology medicine local and general surgery local in Seoul National University Hospital from May, 2003 to October, 2003. The range of motion of the shoulder(flexion, extension, abduction, internal rotation, external rotation) were examined. Analysis of data that shoulder range of motion average and standard deviation, percentage of the unaffected side and affected side compare with normal shoulder range of motion. Paired t-test was adopted to analyze the difference between affected side and unaffected side. Conclusion from this study is as following, 1. The most serious problem was external rotation (0.56%) and internal rotation is the next (19.9%) in 5 kinds of shoulder range of motion in 2 weeks after surgical operation 2. There was no difference in internal rotation after post operation 3 months but there were differences and shown to recover more than 90% in flexion and abduction. Also shoulder function incresed in flextion less than 80% and more than 80% in external rotation. As this study finding was shown that shoulder range of motion did not get back perfectly except of internal rotation and extension in point of 3 months after breast cancer surgical operation. External rotation was specially shown the lowest result so it is needed to exercise for improving their physical functioning recovery in postmastectomy patients. And it is suggested to study for helping to postmastectomy patients' physical and psycosocial functions with the early rehabilitation program which is based on these results.

  • PDF

Digital Image Stabilization Using Simple Estimation of Rotational and Translational Motion (회전 및 병진운동 추정을 통한 디지털 영상안정화)

  • Seok, Ho-Dong;Kang, Kil-Soon;Lyou, Joon
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.46-48
    • /
    • 2004
  • This paper presents a simple method of rotational and translational motion estimation for digital image stabilization. The scheme first computes the rotation center by taking least squares of selected local velocity vectors, and the rotational angle is found from special subset of motion vectors. And then translational motion can be estimated by the relation among movement of rotation center, rotation angle and translation movement. To show the effectiveness of our approach, the synthetic images are evaluated, resulting in better performance.

  • PDF

Concurrent Validity and Clinical Usefulness of Universal Plastic Goniometer for Hip Internal and External Rotation Range Measurement (고관절 내외회전 가동범위 검사에 대한 범용플라스틱 측각기의 동시타당도와 임상적 유용성)

  • Kim, Yong-Wook
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.1
    • /
    • pp.99-105
    • /
    • 2018
  • PURPOSE: The aim of this study was to evaluate the concurrent validity and clinical usefulness of the universal plastic goniometer to measure the range of motion of the internal and external rotation of the hip joint using the three dimensional motion analysis which can analyze the joints and segment movements in the most objective and quantitative method. METHODS: Clinical and kinematic data were collected from thirty individuals using a universal plastic goniometer and a ten camera motion analysis system. Passive hip rotation range was obtained three trials for left and right hip joints using two measure methods simultaneously. RESULTS: There were significant differences between all matching measures of the two measures of internal and external rotation of the hip joint (p<.05). The relationship between the two tests for all measurements of the internal and external rotation of the hip was statistically significant with correlation coefficient form r=.87 to .96. (p<.01). CONCLUSION: Clinical measurement of the internal and external rotation of the hip using a universal plastic goniometer is effective to assess the hip condition. However, application of universal plastic goniometer requires careful attention in more accurate evaluation and research verification of the internal and external rotation of hip joint.

Effect of postural change on shoulder joint internal and external rotation range of motion in healthy adults in their 20s

  • Kim, Beom-Ryong;Yi, Dong-Hyun;Yim, Jong-Eun
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.3
    • /
    • pp.152-157
    • /
    • 2019
  • Objective: We aimed to investigate differences of range of motion in measuring shoulder internal rotation (IR) and external rotation (ER) resulting from posture change in manual scapular stabilization in prone, hook-lying, sitting, and standing positions in healthy young adults. Design: Cross-sectional study. Methods: This study included healthy young adults who agreed to participate after a thorough explanation about the study purpose and methods. A clinometer was used to measure shoulder rotation. Measurements of shoulder rotation according to postural change were performed in prone, hook-lying, sitting, and standing positions. The repeated measures analysis of variance was used to compare between-group differences in postural change. Results: The lower the posture, the greater the average value of IR angle. In contrast, the higher the posture, the greater the average value of the external rotation angle. In active and passive IR with posture change, there was difference in average value but with no statistical significance. In active and passive ER, there was a statistically significant difference between prone and sitting, prone and standing, hook-lying and sitting, hook-lying and standing, and sitting and standing position (p<0.05). Conclusions: Our findings suggest that postural change should be considered in order to increase the strength or range of motion of the internal and external rotation of the patient's shoulder joint.

Reliability and Validity of Measurement Using Smartphone-Based Goniometer of Tibial External Rotation Angle in Standing Knee Flexion

  • Jeon, In-Cheol;Kwon, Oh-Yun;Weon, Jong-Hyuck;Ha, Sung-Min;Kim, Si-Hyun
    • Physical Therapy Korea
    • /
    • v.20 no.2
    • /
    • pp.60-68
    • /
    • 2013
  • The purpose of this study was to assess the intra-rater test-retest reliability of tibial external rotation angle measurement using a smartphone-based photographic goniometer, DrGoniometer (DrG) compared to a three-dimensional motion analysis system (Vicon). The current study showed an interchangeable method using DrG to measure the tibial external rotation angle in standing knee flexion at $90^{\circ}$. Twelve healthy subjects participated in this study. A rest session was conducted 30 minutes later for within-day reliability and five days later for between-day intra-rater test-retest reliability. To assess the validity of the measurement using DrG, we used a three dimensional motion analysis system as a gold standard to measure the angle of tibial external rotation. Intra-class correlation coefficient (ICC) and the standard error of measurement (SEM) values were used to determine the within- and between- day intra-rater test-retest reliability of using DrG and a three dimensional motion analysis system. To assess validity, Pearson correlation coefficients were used for two measurement techniques. The measurement for tibial external rotation had high intra-rater test-retest reliability of within-day (ICC=.88) and between-day (ICC=.83) reliability using DrG and of within-day (ICC=.93) and between-day (ICC=.77) reliability using a three-dimentional motion analysis system. Tibial external rotation angle measurement using DrG was highly correlated with those of the three-dimensional motion analysis system (r=.86). These results represented that the tibial external rotation angle measurement using DrG showed acceptable reliability and validity compared with the use of three-dimensional motion analysis system.

Simple Method of Evaluating the Range of Shoulder Motion Using Body Parts

  • Yun, Yeo-Hon;Jeong, Byeong-Jin;Seo, Myeong-Jae;Shin, Sang-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.1
    • /
    • pp.13-20
    • /
    • 2015
  • Background: The purpose of this study is to assess the range of shoulder motion using an indirect evaluation method without physical examinations of patients based on questionnaires regarding several specific arm postures referenced by patient's own body parts. Methods: Nine criteria of specific shoulder motion including 4 forward flexion, 2 external rotation, and 3 internal rotation were decided as reference position which can represent a certain shoulder motion. Flexion contains postures such as lifting arm to waist-height, shoulder-height, eye-height, and raising arm above head with arm touching ears. External rotation comprises grasping ears and placing hands on back of the head. Vertebral height in internal rotation is determined by calculating the samples' motions, which are holding on to trouser belts, opposite-elbow, and scapula. These postures are included in questionnaires for patients to evaluate the validity and effectiveness of this indirect method. Results: The range of flexion was $77^{\circ}$ ($60^{\circ}$ to $100^{\circ}$), $96^{\circ}$ ($87^{\circ}$ to $115^{\circ}$), $135^{\circ}$ ($115^{\circ}$ to $150^{\circ}$), and $167^{\circ}$ ($150^{\circ}$ to $175^{\circ}$) when arms go up to waist, shoulder, eye, and high vertically. Range of external rotation was $39.6^{\circ}$ ($30^{\circ}$ to $50^{\circ}$) when grasping ears and $69.2^{\circ}$ ($60^{\circ}$ to $80^{\circ}$) with the hands on the back of the head. Range of internal rotation was L4 when placing trouser belts, T12 for holding opposite elbow, and T9 for reaching scapula. The mismatch rates of flexion, external rotation, and internal rotation were 11.6%, 9.6%, and 7.8%. Conclusions: The range of shoulder motion using this method is expected to be applied to an established shoulder scoring system which included shoulder motion evaluation item.