• Title/Summary/Keyword: Rotation axis

Search Result 627, Processing Time 0.029 seconds

Experimental Study on Aerodynamic Performance and Wake Characteristics of the Small Ducted Fan for VTOL UAV (수직 이착륙 무인기용 소형 덕티드팬의 공력성능 및 후류특성에 관한 실험적 연구)

  • Shin, Soo-Hee;Lee, Seung-Hun;Kim, Yang-Won;Cho, Tae-Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.1
    • /
    • pp.1-12
    • /
    • 2022
  • Wind tunnel test for a small scale electric ducted fan with a 104mm diameter was conducted to analyze the aerodynamic characteristics when it was used as a propulsion system of tilt-propeller UAV. Experimental conditions were derived from flight conditions of a sub-scaled OPPAV. Forces and moments of the ducted fan model were measured by a 6-axis balance and 3-dimensional wake vectors which could induce an aerodynamic influence in the vehicle were measured by 5-hole probes. Thrust and torque on hover and cruise conditions were measured and analyzed to drive out the operating conditions when it was applied in the sub-scaled OPPAV. On transition conditions, thrust keep its value with tilt angle variation below 40° and increase after that. But, sideforce increase constantly until 75°. The maximum axial velocity in the wake on hover and cruise conditions was around 60m/s and tangential velocity was around 12m/s. The position of the maximum axial velocity and vortex center move off the fan rotation center line as the tilt angle increases.

A Study on Alternative Concepts of Pre-Elementary Teachers on the Causes of Seasonal Changes (계절변화 원인에 대한 초등예비교사들의 대안개념 연구)

  • Kim, Soon-Shik
    • Journal of the Korean Society of Earth Science Education
    • /
    • v.15 no.2
    • /
    • pp.249-262
    • /
    • 2022
  • This study was conducted on the alternative concept of elementary school pre-service teachers to seasonal changes. From May 2021 to June 2022, it was conducted with 60 pre-primary teachers at P National University of Education. The conclusion of this study is as follows. First, pre-primary teachers explained the cause of seasonal changes, and out of 60 pre-primary teachers, only 22 (36%) had scientific concepts, and the remaining 38 (64%) students had alternative concepts. Second, in explaining how the inclination of the Earth's axis of rotation is related to seasonal changes, only 16 (27%) of the 60 pre-primary teachers had a scientific concept, and the remaining 44 (73%) had alternative concepts. Third, pre-primary teachers explained the relationship between the change in the solar altitude and the seasonal change. Among 60 pre-primary teachers, 12 (20%) had a scientific concept, and the remaining 48 (80%) had alternative concepts. Fourth, looking at the comprehensive types of alternative concepts for seasonal changes, the aS-bS-cS type, which is classified as a type that explains the causes of seasonal changes using scientific concepts as a whole, was 8(13%) out of 60 pre-primary teachers. and the remaining 52 (87%) had at least one alternative concept to explain seasonal changes.

A Study for Predicting Rotational Cutting Torque from Electrical Energy Required for Ground Drilling (지반절삭 전기에너지를 활용한 회전굴착토크 예측에 관한 연구)

  • Choi, Chang-Ho;Cho, Jin-Woo;Lee, Yong-Soo;Chung, Ha-Ik;Park, Yong-Boo
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.7
    • /
    • pp.57-64
    • /
    • 2007
  • This study proposes a method to estimate drilling torque during ground boring with an aid of electrical energy required for rotating a boring-auger. Ground boring is commonly used in geotechnical engineering such as preboring precast pile installation, soil-cement grouting, ground exploration and so forth. In order to understand the correlation between required electrical energy to rotate the boring auger and the drilling torque, a small laboratory apparatus was designed and a pilot study was performed. The apparatus rotates common drill bits of $D=5{\sim}25mm$ in CBR specimens. The velocity of a bit is 19 RPM and predefined using a reduction gear which connects a main rotation axis to a 25 Watts AC electrical motor shaft. In the middle of drilling the motor current increments and the drilling torque were measured and the correlation between the current and the torque was obtained through linear square fits. Based on the correlation the acquired motor current during drilling was applied to predict the drilling torque in consequent testing and the prediction results were compared to the measured torque. The comparison leads a conclusion that the motor current during drilling using electrical power may be a good indicator to estimate/determine strength characteristics of the ground.

Effect of Patient's Positioning on the Grade of Tendinosis and Visible Range of Infraspinatus Tendon on Ultrasound (초음파 영상에서 극하근 힘줄병의 단계와 관찰가능 범위에 환자의 자세가 미치는 영향)

  • Jee Won Chai;Joo-ho Lee;Dong Hyun Kim;Jina Park;So-Hee Oh;Su-Mi Shin
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.627-637
    • /
    • 2023
  • Purpose To investigate the effect of patient positioning on tendinosis grade, visible range, and infraspinatus tendon (IST) thickness, and to determine the feasibility of internal rotation (IR) position to assess IST on ultrasound (US). Materials and Methods This study included 52 shoulders of 48 subjects who were evaluated for IST in three different positions: neutral position (N), IR, and position with the ipsilateral hand on the contralateral shoulder (HC). Two radiologists retrospectively graded IST tendinosis from grade 0 to grade 3 and the visible range from grade 1 to grade 4. The thickness of the IST was measured by another radiologist with a short-axis view. A generalized estimating equation was used for statistical analysis. Results The tendinosis grades were higher in the HC position than in the IR position, with a cumulative odds ratio of 2.087 (p = 0.004, 95% confidence interval [CI]: 1.268-3.433). The tendinosis grades in the HC position (p = 0.370) and IR position (p = 0.146) were not significantly different from those in the N position. The overall difference in IST thickness was significant (p < 0.001), but the visible range (p = 0.530) was not significantly different according to position. Conclusion Patient positioning significantly affected the grade of tendinosis and thickness but not the visible range of the IST. The IR position is a feasible position for assessing the IST on US.

Verify Image-Guided Shifts for 6DoF Couch using Yonsei Cancer Center QA Set (Yonsei Cancer Center QA Set을 이용한 6DoF Couch의 이동 정확성 검증)

  • Jung, Dongmin;Park, Hyokuk;Yoon, Jongwon;Lee, Sangkyu;Kim, Jooho;Cho, Jeonghee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.7-18
    • /
    • 2017
  • Purpose: A QA Set was established to verify the movement accuracy of image-guided 6DoF Couch and to evaluate its usefulness. Materials and Methods: Two sets of linear accelerators equipped with 6DoF Couch and CBCT were used. Using the established QA Set, each CBCT image was obtained over 15 times through the Penta-Guide Phantom installed with off-set shift values along six translational (Translation; TX, TY, TZ) and rotational (Rotation, Pitch; RX, Roll; RY, Yaw; RZ) directions. Using this method, we compared the reference image and the registration image, and we analyzed the error calculated by measuring the positional accuracy of the modified 6DoF Couch. Results: The Air Cavity corresponding to the Pixel of the reference image and the registration image were all contained between 30 and 66, and the revealing high registration accuracy. Error between the modified off-set value of 6DoF Couch and the measured value along translational directions were $0.25{\pm}0.18mm$ in the TX direction, $0.25{\pm}0.25mm$ in the TY direction, and $0.36{\pm}0.2mm$ in the TZ direction. Misalignments along the rotational axis were $0.18{\pm}0.08^{\circ}$ in the RX direction, $0.26{\pm}0.09^{\circ}$ in the RY direction, and $0.11{\pm}0.08^{\circ}$ in the RZ direction, it was corrected precisely for any value. Conclusion: Using the YCC QA Set, we were able to verify the error of 6DoF Couch along both the translational and rotational directions in a very simple method. This system would be useful in performing Daily IGRT QA of 6DoF Couch.

  • PDF

A Study on Mechanical Errors in Cone Beam Computed Tomography(CBCT) System (콘빔 전산화단층촬영(CBCT) 시스템에서 기계적 오류에 관한 연구)

  • Lee, Yi-Seong;Yoo, Eun-Jeong;Kim, Seung-Keun;Choi, Kyoung-Sik;Lee, Jeong-Woo;Suh, Tae-Suk;Kim, Joeng-Koo
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • This study investigated the rate of setup variance by the rotating unbalance of gantry in image-guided radiation therapy. The equipments used linear accelerator(Elekta Synergy TM, UK) and a three-dimensional volume imaging mode(3D Volume View) in cone beam computed tomography(CBCT) system. 2D images obtained by rotating $360^{\circ}$and $180^{\circ}$ were reconstructed to 3D image. Catpan503 phantom and homogeneous phantom were used to measure the setup errors. Ball-bearing phantom was used to check the rotation axis of the CBCT. The volume image from CBCT using Catphan503 phantom and homogeneous phantom were analyzed and compared to images from conventional CT in the six dimensional view(X, Y, Z, Roll, Pitch, and Yaw). The variance ratio of setup error were difference in X 0.6 mm, Y 0.5 mm Z 0.5 mm when the gantry rotated $360^{\circ}$ in orthogonal coordinate. whereas rotated $180^{\circ}$, the error measured 0.9 mm, 0.2 mm, 0.3 mm in X, Y, Z respectively. In the rotating coordinates, the more increased the rotating unbalance, the more raised average ratio of setup errors. The resolution of CBCT images showed 2 level of difference in the table recommended. CBCT had a good agreement compared to each recommended values which is the mechanical safety, geometry accuracy and image quality. The rotating unbalance of gentry vary hardly in orthogonal coordinate. However, in rotating coordinate of gantry exceeded the ${\pm}1^{\circ}$ of recommended value. Therefore, when we do sophisticated radiation therapy six dimensional correction is needed.

Results of Surgical Treatment of Patella Dislocation (슬개골 탈구의 수술적 치료 결과)

  • Kim, Hui Taek;Cho, Yoon Jae
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.2
    • /
    • pp.134-141
    • /
    • 2021
  • Purpose: Patellar dislocations have a range of causes. This study examined the results of treatment aimed at balancing soft tissues around the patella. Materials and Methods: Thirty-two patellar dislocations in 28 patients (21 females and seven males) were examined. The mean patient age at the time of surgery was 11.5 years, and the mean follow-up period was 4.6 years. Dislocations were 19 chronic, six habitual, six congenital, and one acute. Soft tissue balancing surgery included lateral capsular release, medial capsular plication, and inferolateral transfer of the vastus medialis obliquus. Medial transfer of the patellar tendon, partial strip of the rectus femoris and patella tendon, and distal femoral osteotomy were also performed selectively. The preoperative Q angle, femoral anteversion angle, tibial external rotation angle, tibial tubercle-trochlear groove distance (TT-TG distance), mechanical femoral-tibial angle, and femoral trochlear dysplasia according to Dejour were measured, and the pre- and postoperative Lysholm-Tegner scores were used to analyze the clinical results. Results: The mean preoperative Q angle, TT-TG distance, femoral anteversion angle, tibial external rotation angle, mechanical femoraltibia angle, and Lysholm-Tegner score were 9.3°, 15.5 mm, 25.6°, 30.4°, 3.0°, and 75.8, respectively. Eleven patients had systemic ligament laxity with a Beighton score of five or more. Twenty-two patients had femoral trochlear dysplasia: four type A (3 patients), 16 type B (15 patients), one type C (1 patient), and four type D (3 patients). Of the 32 cases, 28 were corrected successfully by the first operation. Of four cases of postoperative subluxation, three were corrected by the second operation, and one of them was corrected after a third operation. The last patient is currently being followed-up. The mean Lysholm-Tegner score improved to 85.6 after the operation. Conclusion: Correcting all the causes of patella dislocation simultaneously is difficult. Nevertheless, satisfactory outcomes were obtained with soft tissue balancing surgery around the patella and a corrective osteotomy for an abnormal mechanical axis of the femur-tibia and torsion.

A LONGITUDINAL STUDY ON THREE FACIAL GROWTH PATTERNS IN KOREANS WITH NORMAL OCCLUSION (정상교합자의 3가지 안면골 성장양상에 관한 누년적 연구)

  • Park, Krung-Duk;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.25 no.3 s.50
    • /
    • pp.273-286
    • /
    • 1995
  • The purpose of this study was to compare the difference of the growth aspects in three facial growth patterns. The biennial serial cephalometric radiographs of 33 samples(19males, 14females) with normal occlusion from 8.5 years to 18.5 yews of age were used in this study. The facial growth patterrn was categorized in 3 types(Drop type, Neutral type, Forward type) by the total amounts of the Y-axis which changed from 8.5 years to 18.5 years of age. The growth change of the craniofacial area during 10 years in each growth type was analyzed and was compared among the 3 growth types. The results of this study might be summarized as follows. 1. The samples that were classified by total change of the Y-axis during this study period were distributed to 52% of the neutral type, 27% of the forward type, 21% of the drop type. 2. The anterior growth of the maxilla to the cranial base(N per A) showed larger in the forward type than in other 2 types(p<0.05). 3. The palatal plane to the FH plane showed more anterior-superior inclination in the forward type with age during this study period. 4. The anterior growth of the mandible to the cranial base(N per Pog) appeared large in rank order, of largest the forward type, second the neutral type, and third the drop type(p<0.05). 5. During this study period the mandibular plane(SN/MN,FMA) showed more counterclockwise rotation in the forward type than in the drop type(p<0.05), and this tendency was stronger in males than in females(p<0.05). 6. The growth of the mandibular corpus length(Go-Me) showed smaller in the drop type than in the other 2 types(p<0.05). 7. In the forward type and the neutral type, the anterior growth of the mandible was larger than that of the maxilla(p<0.05). 8. In the craniofacial growth distances and angulations turned out to be somewhat variable, but the vertical proportion had a strong tendency whose original relation was maintained consistently during this study period. 9. Through these analyzed data, the profilograms on each growth type were constructed to evaluate individual growth pattern in the orthodontic diagnosis.

  • PDF

The Pattern of Initial Displacement in Lingual Lever Arm Traction of 6 Maxillary Anterior Teeth According to Different Material Properties: 3-D FEA (유한요소모델에서 레버암을 이용한 상악 6전치 설측 견인 시 초기 이동 양상)

  • Choi, In-Ho;Cha, Kyung-Suk;Chung, Dong-Hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.213-230
    • /
    • 2008
  • The aim of this study was to analyze the initial movement and the stress distribution of each tooth and periodontal ligament during the lingual lever-arm retraction of 6 maxillary incisors using FEA. Two kinds of finite element models were produced: 2-properties model (simple model) and 24-properties model (multi model) according to the material property assignment. The subject was an adult male of 23 years old. The DICOM images through the CT of the patient were converted into the 3D image model of a skull using the Mimics (version 10.11, Materialise's interactive Medical Image Control System, Materialise, Belgium). After series of calculating, remeshing, exporting, importing process and volume mesh process was performed, FEA models were produced. FEA models are consisted of maxilla, maxillary central incisor, lateral incisor, canine, periodontal ligaments and lingual traction arm. The boundary conditions fixed the movements of posterior, sagittal and upper part of the model to the directions of X, Y, Z axis respectively. The model was set to be symmetrical to X axis. Through the center of resistance of maxilla complex, a retraction force of 200g was applied horizontally to the occlusal plane. Under this conditions, the initial movements and stress distributions were evaluated by 3D FEA. In the result, the amount of posterior movement was larger in the multi model than in the simple model as well as the amount of vertically rotation. The pattern of the posterior movement in the central incisors and lateral incisors was controlled tipping movement, and the amount was larger than in the canine. But the amount of root movement of the canine was larger than others. The incisor rotated downwardly and the canines upwardly around contact points of lateral incisor and canine in the both models. The values of stress are similar in the both simple and multi model.

Motion Reduction Activities in Patients undergoing Myocardial Perfusion SPECT with the Discovery NM 530c(D530c) (Discovery NM 530c(D530c)에서 촬영한 심근관류 SPECT 환자의 움직임 감소활동을 위한 연구)

  • Lee, Dong Hun;Choi, Woo Jun;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.80-85
    • /
    • 2017
  • Purpose The D530c have cadmium zinc telluride(CZT) detectors that are arranged focus on the heart. This structural characteristic allows for quicker imaging without rotation, but this is sensitive to patient movement and can affect the test results. The aim of this study is to optimize the image quality by reducing patient movement during the examination. Materials and Methods We analyzed the patients' movements, and performed various activities such as provided patient education about correct breathing techniques and avoiding patient movements, and created breathing correction tools to minimize patient movement during exam. The 70 patients who underwent myocardial perfusion SPECT with D530c in November 2016 were categorized as the group before the corrective steps. Another 70 patients who underwent the procedure with D530c from February 14, 2017 to February 21, 2017 were categorized as the improvement group. Images acquired during stress and at rest were compared and analyzed by measuring the durations of heart movements over certain distances (4 mm, 8 mm, 12 mm, or more) noted on the x-, y-, and zaxes. Results After the activities, the durations of heart movements decreased in the images acquired both under stress and at rest. In particular, there were no large motions greater than 12 mm recorded in the stress images after the improvement. There was a significant difference (p<0.005) in the 4-mm and 8-mm fluctuations on the X-axis and the 8-mm fluctuations on the Z axis in the stress images, but there was no significant difference (p>0.005) in the other stress and rest intervals. Conclusion The decrease in the time of motion occurrence due to the 4 mm fluctuation distance that can occur through breathing can be understood as a result of the breathing being corrected through training and motion prevention tools. It is expected that the image quality will be improved by reducing the occurrence time according to the variation distance of 8 mm or 12 mm, which is expected as the actual movement of the patient other than the breathing.

  • PDF