• Title/Summary/Keyword: Rotation Operation

Search Result 385, Processing Time 0.029 seconds

MORPHOLOGIC AND POSITIONAL CHANGE OF THE PROXIMAL SEGMENTS AFTER INTRAORALVERTICAL RAMUS OSTEOTOMY OF THE MANDIBULAR PROGNATHISM ON SUBMENTOVERTEX CEPHALOGRAM (하악골 전돌증환자의 구내 하악골상행지 수직골절단술후 이하두정 계측방사선사진상에서의 근심골편의 형태 및 위치 변화)

  • Chung, Jae-Hyung;Park, Hyung-Sik;Hwang, Chung-Ju
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.1
    • /
    • pp.26-34
    • /
    • 2003
  • Intraoral Vertical Ramus Osteotomy,along with Sagittal Split Ramus Osteotomy,is an popular surgical technique performed on mandibular prognathism. However Intraoral Vertical Ramus Osteotomy has been suspected for an initial mobilization at the healing phase of segment because it does not employ the rigid fixation between segments. To execute a study on the healing phase of segment after Intraoral Vertical Ramus Osteotomy on the horizontal plane, 102 patients (204 parts) who were diagnosed mandibular prognathism and took Intraoral Vertical Ramus Osteotomy at the Yonsei University dental hospital were observed during the period of before operation, immediately postoperation, 1 month, 3 months, 6 months, and 12 months. The change in the width of segment and horizontal angle of proximal segment and condylar head on the Submentovertex Cephalogram taken from those patients represented following results. 1. The width of proximal and distal segment decreased with the lapse of time. It decreased into 84.5% between immediate postoperative and 6M and even continued to decrease till 12M. 2. The horizontal angle of the proximal segment did medial rotation according as the lapse of time and rigorously continued till 3M. The rotation angle of condylar head indicated its tendency of recurrence to the original position but the entire recurrence was not allowed. The bigger an initial angle was, the higher was the tendency of recurrence after the operation while the rotation angle remained still bigger. 3. After grouping into group 1, group 2,and group 3 based on the extent of the variation of rotation angle of condylar head at immediate postoperative, the variation of rotation angle was measures in each group. The result presented that the initial rotation angle of condylar head had correlation with that of proximal segment but had no relation with the extent of setback of the mandible. However a quantitative analysis alone is not a sufficient method for analyzing the healing phase of segment on the horizontal plane.Therefore a multilateral analysis using 3 dimensional data such as CT is recommendable for the future study.

The Cooling control system with inverter (인버터를 통한 냉방제어시스템)

  • Moon, Joon-Soo;Woo, Yee-Wan;Park, Jea-Hong
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.43-48
    • /
    • 2011
  • Cooling system's operation ratio shall be controlled automatically by the internal external temperature sensors in rolling stock. The Cooling System shall be the automatic operation ratio control system which automatically controlling the rotation speed of condenser, evaporator etc. using temperature detection from outside and inside of cabin. This paper will examine the cooling system that can be provide comfortable cooling service for passenger in summer.

  • PDF

Low-Complexity and High-Speed Multi-Size Circular Shifter With Benes Network Control Signal Optimization for WiMAX QC-LDPC Decoder (Benes 네트워크 제어 신호 최적화를 이용한 WiMAX QC-LDPC 복호기용 저면적/고속 Multi-Size Circular Shifter)

  • Kang, Hyeong-Ju
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.10
    • /
    • pp.2367-2372
    • /
    • 2015
  • One of various low-density parity-check(LDPC) codes that has been adopted in many communication standards due to its error correction ability is a quasi-cyclic LDPC(QC-LDPC) code, which leads to comparable decoder complexity. One of the main blocks in the QC-LCDC code decoder is a multi-size circular shifter(MSCS) that can perform various size rotation. The MSCS can be implemented with many structures, one of which is based on Banes network. The Benes network structure can perform the normal MSCS operation efficiently, but it cannot use the properties coming from specifications like rotation sizes. This paper proposesd a scheme where the Benes network structure can use the rotation size property with the modification of the control signal generation. The proposed scheme is applied to the MSCS of IEEE 802.16e WiMAX QC-LDPC decoder to reduce the number of MUXes and the critical path delay.

Practicability Assessment of Spherical Mechanical Check Device(SMCD) (Mechanical Check용 Spherical device의 제작 및 특성 평가)

  • Lee, Byung-Koo;Yang, Dae-Sik;Kweon, Young-Ho;Ko, Shin-Gwan;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.153-159
    • /
    • 2007
  • Digital medical image commenced with an introduction of PACS has become more popular today in the radiation diagnosis and radiation treatment and made great progress, in particular, for medical testing field, whereas it has made slow progress for radiation treatment field. In order to accommodate the current trend of digital from analog, a spherical mechanical check device(SMCD) that is the form of spherical differing from the existing form of flat or cube has been designed and tested its practicability to replace the part in mechanical check with digital image from QA operation. If the distance maintains constance between source(target) and image detector with constant distance to the center of spherical mechanical check device(SMCD), the size will be shown as a constant image at all times regardless of its direction exposed. For the test, two accurate hemispheres are made and put together which results in a sphere of the equilateral circle. It enables a variety of implementation of the existing mechanical check using digital image as follows: congruity level of radiation field and light field, size accuracy of radiation field and collimation field, gantry rotation isocenter check, collimation rotation isocenter check, room laser accuracy check, collimation rotation angle check, couch rotation angle check, and more. In addition, it has proved its practicability in checking isocenter congruity level as real time at the time of simultaneous rotation between gantry and couch that is applied to the non-coplanar field, which had been hard to apply as a device formed of existing flat or cube.

  • PDF

Practicability Assessment of Spherical Type Mechanical Check Device (SMCD) (Mechanical Check용 Spherical Device의 제작 및 특성 평가)

  • Lee, Byung-Koo;Kim, Gun-Oh;Kweon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.55-62
    • /
    • 2007
  • Purpose: Digital medical image commenced with an introduction of PACS has become more popular today in the radiation diagnosis and medical treatment and made great progress, in particular, for medical testing field, whereas it has made slow progress for radiation therapy area. In order to accommodate the current trend of digital from analog, a spherical type mechanical check device (SMCD) that is form of spherical differing from the existing form of flat or cube has been designed and tested its practicability to replace the part in mechanical check with digital image from QA operation. Materials and Methods: If the distance maintains constant between source(target) and image detector with constant distance to the center of spherical type mechanical check device(SMCD), the size will be shown as a constant image at all times regardless of its direction exposed. For the test, two accurate hemispheres are made and put together which results in a sphere of the equilateral circle. Results: It enables a variety of implementation of the existing mechanical check using digital image as follows: congruity level of radiation field and light field, size accuracy of radiation field and collimation field, gantry rotation isocenter check, collimation rotation isocenter check, room laser accuracy check, collimation rotation angle check, couch rotation angle check, and more. Conclusion: It has proved its practicability in checking isocenter congruity level as real time at the time of simultaneous rotation between gantry and couch that is applied to the non-coplanar field, which had been hard to apply as a device formed of existing flat or cube.

  • PDF

Record and Replay Motion Implementation to Modular Toys using Two Potentiometers (두개의 전위차계를 이용한 모듈형 완구의 동작 저장 및 반복 재생 동작의 구현)

  • Lee, JinKyu;Lee, BoHee;Kim, JongTae;Park, JiYoup;Kong, JungShik
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.2
    • /
    • pp.59-65
    • /
    • 2017
  • In order to realize the operation of the creative modular toy, it is required to record the motion and to read and repeat the motion. At this time, a control potentiometer is used to read the absolute angle of rotation of the toy motion output shaft. However, the unstable part of the sensing area of the potentiometer is present in a certain region, which may lead to instability of the motor control. In this paper, we propose an algorithm to find the absolute angle of one rotation by reading two stable potentiometers on one axis and reading each stable region. We also describe the correction algorithm that is needed to perform multiple rotations. The proposed method is applied to Topobo modular toys to record the operation and perform iterative operation. In addition, multi-turn operation is recorded and operated to suggest the usefulness of the proposed method. In the future, we will expand the functions of recording and playback through various actions.

Stuides on the Cutting Methods of the Self-feeding Type Combine -on the Mixed Cutting Method (1)-on the Mixed Cutting Method(I) (자탈형 콤바인의 예취작업법에 관한 연구 -혼합예취법을 중심으로 (제1보)-)

  • 최복연
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.18 no.2
    • /
    • pp.4096-4104
    • /
    • 1976
  • This experiment was carried out to investigate the efficient turning method which will be able to use every cutting methods, to calculate the width of the center field which must transpose from rotary cutting method to return cutting method, to investigate the effects of L/W and unit field on the operation efficiency. The results are summarized as follows: 1. In case of cutting in the outer field, the efficient turning method is the "$\alpha$" type turning method (half U-shaped turning method) at the first rotation, is the "$\beta$" type turning method (T-shaped turning method) at the second to fourth rotation. 2. In case of cutting in the inner field, the efficient turning method which takes the least turning time is the "a" type turning method ($\Delta$-shaped turning method). 3. The width of the center field (W') changes by the length-width ratio (L/W) and width (W), W' is 9.0m in case that L/W is 2.5 and W is 30m. 4. The larger L/W and area of unit field (A) become, the more operation efficiency (E) increases, and the limits that E is affected signicantly by L/W is 2 to 3.5 and A is within 5,000$m^2$. within 5,000$m^2$.

  • PDF

Comparison of Scapular Position Between Operation and Non-operation Side to the Rotator Cuff Surgery (회전근개 수술 환자의 수술측과 비수술측 간에 견갑골 자세 비교)

  • Jeong, Eui-young;Kim, Suhn-yeop
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.22 no.2
    • /
    • pp.15-20
    • /
    • 2016
  • Background: The purpose of this study was to compared of scapular position between operation side and non-operation side to the rotator cuff surgery. Methods: This study was carried out with a total 34 patients: male (n=14), female (n=20). Shoulder range of motion (ROM), the quadruple visual analogue scale (QVAS), the shoulder pain and disability index (SPADI), and the scapular index (SI) were used to assess shoulder posture and function. SI was the resting position of the scapular was determined by measuring the distance from the mid-point of the sternal notch (SN) to the medial aspect of the coracoid process (CP) and the horizontal distance from the posterolateral angle of the acromion (PLA) to the thoracic spine (TS) with a soft tape measure. The SI was calculated using the equation: [(SN to CP/PLA to TS) ${\times}$ 100]. Results: There were no significant difference in ROM, QVAS to rotator repair patients according to SI (p>.05). There were significant differences in SI between the operation side and the non-operation side (p<.01). Conclusions: Scapular position was operation side more internal rotation, protraction, abduction than non-operation side. Therefore, health professionals managing for rotator cuff tear repair patients should consider scapular position.

  • PDF

Development of Stem-cutting Transplanter for Short-term Rotation Coppice (단기순환림 생산을 위한 삽목 이식기 개발)

  • Kim, Dong-Hwa;Kim, Dae-Cheol;Kim, Sang-Hun;Shin, Beom-Soo
    • Journal of Biosystems Engineering
    • /
    • v.35 no.1
    • /
    • pp.37-45
    • /
    • 2010
  • Since SRC (Short-term Rotation Coppice) such as poplar and willow can be harvested in three years, they are known to be a potential forest biomass as fuel for a power plant. The production system including transplanting and harvesting is, however, necessary to be mechanized because such a biomass should be handled in a massive volumetric size. A pull-type stem-cutting transplanter was developed in the research as the first step to realize the production of SRC. A needle-like transplanting device pushes a stem-cutting into the prepared soil bed by a pneumatic cylinder, and another device firms soil around a stem-cutting transplanted. Since this is an intermittent operation, it was necessary to develop a zero horizontal velocity mechanism which enabled only the transplanting needle part to continue a zero horizontal movement relative to the ground during the transplanting operation even when the tractor kept moving forward. The 2-row transplanter can transplant stem-cuttings at the rate of 6.5 seconds per row without missing a single attempt. The planting depth and distance were well maintained and controlled. Their CVs were between 2.1~3.4% and 0.87~1.7% for the depth and the distance, respectively. Although, the transplanted stem-cuttings tended to lean outward from the back-view and forward from the side view, they were planted within the range of $3^{\circ}$ from the upright position.

Design and Stability Analysis of MAP Network Management Module (MAP 네트워크 관리 모듈의 설계와 안정성 해석)

  • 김정호
    • Journal of the Korean Professional Engineers Association
    • /
    • v.28 no.3
    • /
    • pp.121-134
    • /
    • 1995
  • To operate the automatic devices of manufacturing process more effectively and to solve the needs of the resource sharing, network technology is applied to the unit con-trol devices located In common manufacturing zone and operated by connecting them. The network management system, which controls and supervises the network resources in the communication network, is the function that is necessarily required in this net-work. For the stability in this network, this paper measures the variation of data packet length and node number and analyzes the variated value of the token rotation time and waiting time for the network operation. On the evalution of the performance, the data packet length varies from 10 bytes to 100 bytes in the operation of the group manage-ment network, the variation of the token rotation time and waiting time is less than 10 msec. When the variation of the data packet lenhth is less than 50 bytes, differences in token rotation time or waiting time is unnoticable. Since the waiting time in this case is less than 10 msec, response time Is fast enough.

  • PDF