• 제목/요약/키워드: Rotating Pipe Flow

검색결과 37건 처리시간 0.023초

Slim hole 환형관내 고-액 2상 유동에 관한 연구 (Solid-liquid two phase helica l flow in a Rotating Annulus)

  • 한상목;우남섭;황영규;김영주
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.369-372
    • /
    • 2008
  • An experimental study is carried out to study two-phase vertically upward hydraulic transport of solid particles by water in a vertical and inclined (0${\sim}$60 degree) concentric annulus with rotation of the inner cylinder. Rheology of particulate suspensions in shear-thinning fluids is of importance in many applications such as particle removal from surfaces, transport of proppants in fractured reservoir and cleaning of drilling holes, and so on. Annular fluid velocities varied from 0.2 m/s to 1.5 m/s for the actual drilling operational condition. Macroscopic behavior of solid particles, averaged flow rate, and particle rising velocity are observed. Main parameters considered in this study were radius ratio, inner-pipe rotary speed, fluid flow regime, and particle injection rate. For both water and CMC solutions, the higher the concentration of the solid particles is, the larger the pressure gradients become

  • PDF

150℃에서 원전 2차측 배관재료의 Cr함량에 따른 유체가속부식 특성 (Effect of Cr content on the FAC of pipe material at 150℃)

  • 박태준;김홍표
    • Corrosion Science and Technology
    • /
    • 제12권6호
    • /
    • pp.274-279
    • /
    • 2013
  • Flow accelerated corrosion (FAC) of the carbon steel piping in nuclear power plants (NPPs) has been major issue in nuclear industry. During the FAC, a protective oxide layer on carbon steel dissolves into flowing water leading to a thinning of the oxide layer and accelerating corrosion of base material. As a result, severe failures may occur in the piping and equipment of NPPs. Effect of alloying elements on FAC of pipe materials was studied with rotating cylinder FAC test facility at $150^{\circ}C$ and at flow velocity of 4m/s. The facility is equipped with on line monitoring of pH, conductivity, dissolved oxygen(DO) and temperature. Test solution was the demineralized water, and DO concentration was less than 1 ppb. Surface appearance of A 106 Gr. B which is used widely in secondary pipe in NPPs showed orange peel appearance, typical appearance of FAC. The materials with Cr content higher than 0.17wt.% showed pit. The pit is thought to early degradation mode of FAC. The corrosion product within the pit was enriched with Cr, Mo, Cu, Ni and S. But S was not detected in SA336 F22V with 2.25wt.% Cr. The enrichment of Cr and Mo seemed to be related with low, solubility of Cr and Mo compared to Fe. Measured FAC rate was compared with Ducreaux's relationship and showed slightly lower FAC rate than Ducreaux's relationship.

Coil Insert에 의한 회전열파이프의 내부유동 및 열전달특성에 관한 연구 (A Study on Characteristics of Internal flow Pattern and Heat Transport Performance by Installing a Coil Insert in the Inside Wall of a Rotating Heat Pipe)

  • 김선주;이진성;김철주;박이동
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1996년도 추계학술발표회 논문집
    • /
    • pp.181-189
    • /
    • 1996
  • 회전열파이크는 전기모터, 고온가스터빈 등의 냉각에 이용함으로써 성능개선을 얻을 수 있다는 점에서 지난 20년 동안 많은 연구가 이루어져왔다. 그동안 내부벽면형상개발은 Taper를 설치하거나, 계단식 단면변화 또는 Impeller설치와 같은 기술들이 연구되었다. 본 연구는 회전 열파이프 용기내벽에 Coil Insert를 설치하여 응축액막 유동효과에 대한 가시화실험 및 열전달 성능실험을 통하여 그 특성을 검토하였고 아래와 같은 결과를 얻을 수 있었다. 1) Pool 영역에서는 Coil Insert에 의한 축방향 펌프효과가 매우 크며, 그 효과는 나선각이 클수록 크게 나타난다. 2) Coil Insert는 Pool에서 환상류로 천이를 촉진시키며, 나선각이 클수록 그 효과가 크게 나타난다. 3) Coil insert 열파이프의 열저항에 미치는 효과는 크지 않은 것으로 보인다. 4) Coil Insert에 의해 Dry-out한계의 증가가 예상되지만, 실험장치의 열부하한계에 의해 확인할 수 없었다.

  • PDF

직결식 변속펌프의 운전 방안에 대한 연구 (A Study on the Operating Characteristics of Variable Speed Pump for In-Line Booster Pumping Station)

  • 박종문;최성일;노형운;서상호;김상균
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.191-196
    • /
    • 2001
  • In the systems with largely pipe head loss, variable speed pumps are generally used because substantial energy saving can be expected from such systems by controlling pump speed and also they offer simpler maintenance and operational ease even in conditions where abrupt changes In flow rate and head can occur. The invertor or the fluid coupling system are mainly adopted to control the rotating speed. In this paper, operating conditions at Migum pressing pump station(5 stage), where the fluid coupling system was the first installed for KOWACO, are investigated and analysed so that information thus gained can be usefully employed in the efficient operation of variable speed pump in new installations of in-line booster pumping station.

  • PDF

양광시스템내 스크류피더 이송성능에 관한 연구 (Study on the performance of transportation using the screw-feeder in lifting system)

  • 김영주;한상목;황영규;윤치호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2574-2577
    • /
    • 2008
  • The screw-feeders are used at gathering the minerals at the seafloor, transportation of the sewage, and at the beverage industry. This study was carried out to study solid-liquid mixture hydraulic transport of solid particles in a horizontal and inclined screw-feeders with rotating. This study is about the amount of the alteration amount of the material transportation for regular transportation. In this study a clear acrylic pipe was used in order to observe the movement of solid particles. Relates to the angle, rpm and ratio of pitch ; finding the optimum condition and knowing about designing the screw feeders shape. As a result, we found the suitable rpm and a suitable angle. According to the experiment, the best rpm and angle are 100-200rpm and $10^{\circ}$, respectively.

  • PDF

경사 환형관내 고-액 혼합 유동특성에 관한 연구 (Study on Solid-liquid Mixture Flow in Inclined Annulus)

  • 김영주;김영훈;우남섭
    • 한국해양공학회지
    • /
    • 제25권5호
    • /
    • pp.15-20
    • /
    • 2011
  • This study carried out a series of experiments involving impact tests (Drop Weight type & Charpy type with a standard specimen and newly designed I-type specimen), hardness tests, and fracture surface observations of French-made roll shell steel (F), abnormal roll shell steel (M), reheated roll shell steel (R), and S25C steel under heat treatment conditiAn experimental study was carried out to study the solid-liquid mixture upward hydraulic transport of solid particles in vertical and inclined annuli with a rotating inner cylinder. The lift forces acting on a fluidized particle play a central role in many important applications such as the removal of drill cuttings in horizontal drill holes, sand transport in fractured reservoirs, sediment transport, the cleaning of particles from surfaces, etc. In this study a clear acrylic pipe was used to observe the movement of solid particles. Annular velocities varied from 0.4 to 1.2 m/s. The effect of the annulus inclination and drill pipe rotation on the carrying capacity of a drilling fluid, particle rising velocity, and pressure drop in a slim hole annulus were measured for fully-developed flows of water and aqueous solutions of CMC (sodium carboxymethyl cellulose) and bentonite. The rotation of the inner cylinder was efficient at carrying particles to some degree. For a higher particle volume concentration, the hydraulic pressure loss of the mixture flow increased because of the friction between the wall and solids or between solids.

클린 디젤엔진용 워터펌프 유동해석 (Flow Analysis of Water Pump for Clean Disel Engine Application)

  • 이동주;김태영;전문수
    • 융복합기술연구소 논문집
    • /
    • 제4권2호
    • /
    • pp.61-65
    • /
    • 2014
  • Pressure distribution around rotating impeller blades in centrifugal pump has been main issue for design of efficient and high performance automotive water pump. In addition, pressure losses of inlet water pipes should be considered to reduce additional pressure drop and design high performance engine cooling system. In this paper, pressure distribution inside water pump and pressure drop between inlet and outlet of water pump are investigated numerically to design plastic water pump for clean diesel engine application. And the inlet geometry of water pump was considered to analysis the effect of inlet water pipe geometry on pressure distribution around impeller blades and outlet pressure. The prediction results are compared with experimental data to validate and determine optimal operation condition without water pump cavitation. Major design parameters such as blade angle, volute geometry, system pressure, and coolant flow rate are considered to confirm applying possibility of plastic blades to the clean diesel engine.