다운동 방식 회전단조기 개발 (Development of Rotary Forging Press with Multi-Rocking Motion)

  • 이윤우;김소겸;최상수;박준수;김윤배;임성주;윤덕재;김승수;박훈재
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1995년도 제2회 단조심포지엄 단조기술의 진보
    • /
    • pp.47-54
    • /
    • 1995
  • Rotary forging process has many advantages such as compacting of machine, low price of facilities and good quality of products. The last presented was a technical report about rotary forging press in the 100-ton class, which has the only orbital motion limited to the forming of axisymmetric parts. In this paper, the newly developed rotary forging press is introduced. The maximum capacity of forming load is 280 ton and five locking motion, this is, orbital, straight pivot, spiral and two kinds of clover can be available. This machine consists of transmission, double eccentric bush, rocking shaft, die set and hydraulic unit. Especially, the supports of rocking shaft and double eccentric bush are so crucial that hydrostatic bearings are adopted. Finally, it is expected that the technical know-how obtained in this research can be applied to the manufacturing of the another machine with large capacity.

승용차용 전자제어식 조향장치의 개발 (Development of an electronically-controlled power steering for passenger cars)

  • 홍예선
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.698-703
    • /
    • 1990
  • This paper describes an Electronically-controlled Power Steering system which is developed by the modification of a conventional power steering based on so called rotary valve technology. The steering effort is influenced by the electrohydraulic flow rate control of the pressurized oil to rotary valve. The vehicle speed and the steering angular velocity are used to calculate and output a signal to proportional flow rate control valve by the Electronic Control Unit. The improvement of the steering feel was satisfactory compared with that of the original conventional power steering.

  • PDF

Comparison of apical extrusion of intracanal bacteria by various glide-path establishing systems: an in vitro study

  • Dagna, Alberto;El Abed, Rashid;Hussain, Sameeha;Abu-Tahun, Ibrahim H;Visai, Livia;Bertoglio, Federico;Bosco, Floriana;Beltrami, Riccardo;Poggio, Claudio;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제42권4호
    • /
    • pp.316-323
    • /
    • 2017
  • Objectives: This study compared the amount of apically extruded bacteria during the glide-path preparation by using multi-file and single-file glide-path establishing nickel-titanium (NiTi) rotary systems. Materials and Methods: Sixty mandibular first molar teeth were used to prepare the test apparatus. They were decoronated, blocked into glass vials, sterilized in ethylene oxide gas, infected with a pure culture of Enterococcus faecalis, randomly assigned to 5 experimental groups, and then prepared using manual stainless-steel files (group KF) and glide-path establishing NiTi rotary files (group PF with PathFiles, group GF with G-Files, group PG with ProGlider, and group OG with One G). At the end of canal preparation, 0.01 mL NaCl solution was taken from the experimental vials. The suspension was plated on brain heart infusion agar and colonies of bacteria were counted, and the results were given as number of colony-forming units (CFU). Results: The manual instrumentation technique tested in group KF extruded the highest number of bacteria compared to the other 4 groups (p < 0.05). The 4 groups using rotary glide-path establishing instruments extruded similar amounts of bacteria. Conclusions: All glide-path establishment instrument systems tested caused a measurable apical extrusion of bacteria. The manual glide-path preparation showed the highest number of bacteria extruded compared to the other NiTi glide-path establishing instruments.

Incidence of postoperative pain after using single continuous, single reciprocating, and full sequence continuous rotary file system: a prospective randomized clinical trial

  • Umesh Kumar;Pragnesh Parmar;Ruchi Vashisht;Namita Tandon;Charan Kamal Kaur
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제23권2호
    • /
    • pp.91-99
    • /
    • 2023
  • Background: Extrusion of debris is a major factor that results in postoperative pain during root canal treatment with various instruments and instrumentation techniques. Therefore, instrumentation techniques that extrude minimal debris into the periapical area while reducing pain are desirable. This study aimed to compare the incidence of postoperative pain and intake of analgesic medication (frequency and quantity) after endodontic treatment of mandibular posterior teeth using two single files and full-sequence continuous rotary systems with different kinematic motions. Methods: Thirty-five of 105 patients were assigned equally to three groups according to the instrumentation system used: ProTaper Next (PN) X2, 25/06 (Dentsply, Maillefer, Ballaigues, Switzerland), One Shape (OS), #0.25/06 (Micro Mega, Besancon, France), and Wave One Gold (WG), Red - #0.25, 0.07 (Dentsply, Maillefer, Ballaigues, Switzerland). Five specialists were included in this study design; each professional prepared 21 teeth, and randomly selected 7 per instrument system. The VAS sheet ranging from 0 to 10 was used to record the initial and postoperative pains at 24, 48, and 72 h, and 7th day after single visit endodontic treatment in mandibular premolars and molars with a diagnosis of asymptomatic irreversible pulpitis with or without apical periodontitis. Postoperatively, an analgesic, ibuprofen 400 mg was administered for intolerable pain at a dose of 1 tablet for 6 h. The patients were asked over the telephone regarding postoperative pain at intervals of 24, 48, and 72 h, and 7th day using a visual analogue scale. Result: There were no statistically significant differences among the PN, OS, and WG systems (P > 0.05) with regard to the incidence of postoperative pain at any of the four time points assessed. Conclusion: The intensity of postoperative pain, frequency, and analgesic intake were similar across all three types of instrument systems; however, the reciprocating single file (WG) was associated with less postoperative pain than the full sequence continuous rotary file.

자기 유변 유체를 이용한 각도 제한 회전 감쇠기 설계 및 응용 (Constrained rotary MR damper design and its application)

  • 김상화;박영진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.191-194
    • /
    • 1997
  • Passive, semi-active and active dampers have been used to dissipate energy in mechanical systems. Semi-active dampers have higher performance than passive dampers and require lower power to operate than active dampers. Its damping characteristics can be changed appropriately for varying conditions. In this paper, we developed a semi-active damper based on Magnetorheological(MR) fluid. MR fluid has a variable damping characteristics proportional for the magnetic field intensity. It has several advantages such as high strength, low viscosity, robustness in impurities and wide temperature range of operational stability. We designed a constrained rotary MR damper base on valve mode which can dissipate more energy per unit volume. The system with Bingham characteristics is obtained and proved by the experiment.

  • PDF

볼과 소켓의 정밀 체결을 위한 회전성형 장치 (Rotary Forming Equipment for Precision Joining of the Ball and the Socket)

  • 전병윤;엄재근;전만수
    • 소성∙가공
    • /
    • 제16권2호
    • /
    • pp.132-137
    • /
    • 2007
  • A double roll rotary forming equipment is presented in this paper. The equipment is developed for joining the socket with the ball of a concave piston assembly with its geometrical tolerance requirements satisfied. The equipment is composed of a lathe, a double roll system and a roll pressing unit driven by the hydraulic system. The workpiece rotates by spindle chuck of the lathe while the double roll system approaches perpendicularly to the central line of the workpiece. The equipment is successfully applied to precision joining of the ball and the socket fur the concave piston assembly of a high pressure hydraulic pump.

스트레이트 숫돌에 의한 대직경 Si-wafer의 ELID 경면연삭 (Mirror Surface ELID Grinding of Large Scale Diametral Silicon Wafer with Straight Type Wheel)

  • 박창수;김경년;김원일
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.946-949
    • /
    • 2001
  • Mirror surface finish of Si-wafers has been achieved by rotary in-feed machining with cup-type wheels in ELID grinding. But the diameter of the workpiece is limited with the diameter of the grinding wheel in the in-feed machining method. In this study, some grinding experiments by the rotary surface grinding machine with straight type wheels were conducted, by which the possible grinding area of the workpiece is independent of the diameter of the wheels. For the purpose of investigating the grinding characteristics of large scale diametral silicon wafer, grinding conditions such as rotation speed of grinding wheels and revolution of workpiece are varied, and grinding machine used in this experiment is rotary type surface grinding m/c equipped with an ELID unit. The surface ground using the SD8000 wheels showed that mirror like surface roughness can be attained near 2~6nm in Ra.

  • PDF

좌우 틸팅이 가능한 굴삭기 버켓용 로터리 액츄에이터 설계 및 시험 (Design and Performance Test of a Rotary Actuator for Side Tilting Excavator Bucket)

  • 박민수;이준석;김도엽;이응석
    • 한국정밀공학회지
    • /
    • 제34권1호
    • /
    • pp.47-51
    • /
    • 2017
  • Generally, a working excavator has only one directional bucket tilting angle, which is up-forward. However, side direction rotation of the bucket would allow variety of working output. We designed a hydraulic rotary actuator comprising a double rod hydraulic cylinder with a rack-pinion gear set for use in excavator bucket with side tilting mechanism, thus converting the linear to angular motion. The proposed side tilting rotary actuator was designed with parts suitable for medium size of heavy duty excavator. These mechanical parts were inexpensive to purchase and the manufacturing cost was reasonable. The proposed mechanism is potentially useful for excavator with variety of working output.

HDD 스핀들 모터 유니트 및 커버, 베이스의 동특성 해석 (Dynamic Analysis of HDD Spindle Motor Unit; Cover. Base)

  • 이성진;이장무
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.832-936
    • /
    • 1996
  • In this paper, we study a dynamic characteristics of HDD. HDD is constructed by spindle motor/disk unit, cover, base, E-block arm/suspension unit, and rotary actuator/voice coil motor. First, we make a FE model of spindle motor/disk unit and analyzed natural frequency/mode analytically and experimentally. Especially, the change of natural frequecy of spindle motor unit according to change of B.C is considered. Second, FE model of cover, base is made. Third, we assemble the above three FE mode, we get HEE assembly and dynamic analysis of HDD assembly is accomplished.

  • PDF

로터리테이블용 롤러기어캠의 5-축 가공에 관한 연구 (A Study on 5-Axis Machining of Roller Gear Cam for Rotary Table)

  • 조현덕;박종배;신용범;이광수
    • 한국기계가공학회지
    • /
    • 제16권4호
    • /
    • pp.127-134
    • /
    • 2017
  • A rotary table is a positioning device used in metalworking for the multiple axes of machine tools, and the utilization trend is increasing with machining efficiency. In the construction of a rotary table, the core technology is a power transfer unit that drives the table, typically a gear type and a roller gear cam type. As the rollers installed on the turret column have rolling movement on the contact surface of the roller gear cam, the roller gear cam type has the advantage of low wear, high load, and fast driving. Therefore, it is currently being replaced by a roller gear cam type. In this study, we researched a 5-axis machining method for the roller gear cam on a rotary table and a new method of applying double roller gear cam curve to reduce the noise and shock between the roller and the cam surface. We implemented the 5-axis machining process in this study using software to generate NC-code and machined the roller gear cams using a Mazak Integrex-200IV. We found that the roller gear cam and turret were able to identify mutual touch status and the noise from the operation of the roller gear cam was substantially reduced.