• 제목/요약/키워드: Rotary heat exchanger

검색결과 29건 처리시간 0.024초

로타리 압축기 저주파 특성에 관한 연구 (Study on Low Frequency Characteristics of Rotary Compressor)

  • Byoungha Kwon;Park, Sinkyu;Insu Hwang
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.384.2-384
    • /
    • 2002
  • Compressor is a major noise source of air-conditioner. Especially, its low frequency band noise below 1000㎐ is very important because it will not be attenuated by passing through the cover panel and heat exchanger in air-conditioner. The factors affecting the low frequency band noise are studied by geometric similarity along with several experiments, and the low frequency noise is closely related with the discharge holes of muffler as well as the cavity of lower shell. (omitted)

  • PDF

기액분리기를 적용한 가스 인젝션 히트펌프의 성능 향상에 관한 실험적 연구 (The Performance Improvement of a Gas Injection Heat Pump with a Flash Tank)

  • 손길수;김동우;최성경;김용찬
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.297-305
    • /
    • 2017
  • Air-source heat pumps are widely used in residential heating systems. However, the decrease in the capacity of the heat pump is unavoidable when operating at very low and high ambient temperatures. The vapor injection technique is considered a promising technology to overcome this problem. Recent research on vapor injection cycles have mainly adopted a scroll compressor with an internal heat exchanger at severe operating conditions. This study measured the COP and EER of a gas injection heat pump using a flash tank with an inverter-driven rotary compressor at severe operating conditions. Compared to non-injection heat pumps, the heating capacity and COP of the gas injection heat pump improved up to 15% and 2.9%, respectively, at outdoor temperatures of $-10^{\circ}C$ to $7^{\circ}C$. The cooling capacity of the gas injection heat pump was 11% higher than the non-injection heat pump at an outdoor temperature of $35^{\circ}C$. At the same time, the EER of the gas injection heat pump was similar to that of the non-injection heat pump.

진동인텐시티를 이용한 로타리압축기 진동 해석 (Vibration Analysis of Rotary Compressor based on Vibration Intensity)

  • 안병하;이장우
    • 한국정밀공학회지
    • /
    • 제20권9호
    • /
    • pp.166-172
    • /
    • 2003
  • Vibration and Noise of air conditioner are entirely determined by compressor vibration. Compressor vibration transmitted to the enclosure of air conditioner or pipes connected compressor with heat exchanger. Enclosure generate(noise and vibration. Therefore, the analysis of compressor vibration analysis is considered significant technical issue. For the reduction of vibration of compressor, it is necessary to grasp correctly vibration transmission paths and excitation sources in the compressor shell. Because, shell ( Surface of compressor ) shows whole vibration characteristic of compressor mechanism. In this paper, vibration intensity was applied to measure vibration energy flow on the shell .From this technique, it is possible to catch the path of vibration propagation along the one cycle and the location of vibration energy sources may change with time on the shell.

진동인텐시티를 이용한 로타리압축기 진동 해석 (Vibration Analysis of Rotary Compressor based on Vibration Intensity)

  • 이장우;김영종;안병하
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.973-978
    • /
    • 2003
  • Vibration and Noise of air conditioner are entirely determined by compressor vibration. Compressor vibration transmitted to the enclosure of air conditioner or Pipes connected compressor with heat exchanger. Enclosure generated noise and vibration. Therefore, the analysis of compressor vibration analysis is considered significant technical issue. For the reduction of vibration of compressor, it is necessary to grasp correctly vibration transmission paths and excitation sources in the compressor shell. Because, shell (Surface of compressor) shows whole vibration characteristic of compressor mechanism. In this paper, vibration intensity was applied to measure vibration energy flow on the shell. From this technique, it is possible to catch the path of vibration propagation along the one cycle and the location of vibration energy sources may change with time on the shell.

  • PDF

R407C 및 R410B 적용 창문형 에어컨의 성능에 관한 실험적 연구 (An experimental study on the performance of a window system air-conditioner using R407C and R410B)

  • 김만회;신정섭;김권진
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.536-544
    • /
    • 1997
  • This study presents test results of a residential window system air-conditioner using R22 and two potential alternative refrigerants, R407C and R410B. A series of performance tests was performed for the basic and liquid-suction heat exchange cycle in a psychrometric calorimeter test facility. For R407C, the same rotary compressor was used as in the R22 system. However, compressor for the R410B system was modified to provide the similar cooling capacity. The evaporator circuit was changed to get a counter-cross flow heat exchanger to take advantage of zeotropic mixture's temperature glide, and liquid-line suction-line heat exchange cycle was also considered to improve the performance of the system. Test results were compared to those for the basic R22 system.

  • PDF

SUS304L 튜브의 U-Bending 성형공정에 관한 해석적·실험적 연구 (Numerical and Experimental Study of U-Bending of SUS304L Heat Transfer Tubes)

  • 김유범;강범수;구태완
    • 소성∙가공
    • /
    • 제23권7호
    • /
    • pp.405-412
    • /
    • 2014
  • As a major type of heat exchanger, the steam generator (SG) produces steam from heat energy of a nuclear power plant reactor. The steam produced by the steam generator flows into a turbine, and plays an important role in electric power generation. The heat transfer tubes in the steam generator consist of approximately 10,000 U-shaped tubes, which perform a structural role and act as thermal boundaries. The heat transfer tubes conduct the thermal energy between the primary coolant (about $320^{\circ}C$, $157kgf/cm^2$) obtained from the reactor and the secondary coolant (about $260^{\circ}C$, $60kgf/cm^2$) as part of the secondary system. Recently, the heat transfer tubes in the steam generator of the pressurized water reactor (PWR) are primarily produced from Alloy 600 and Alloy 690 seamless tubes. As a pilot study to find process parameters for the cold U-bending process using rotary draw bending, numerical and experimental investigations were conducted to produce U-shaped tubes from long straight SUS304L seamless tubes. 3D finite element simulations were run using ABAQUS Explicit with consideration of the elastic recovery. The process parameters studied were the angular speed, the operation period and the bending angle. Experimental verifications were conducted to insure the suitability of the final U-shaped configurations with respect to both ovality and wall thickness.

인버터 로터리 압축기 오일 토출량 산정의 실험적 고찰 (An Experimental Study on the Estimation of Oil Discharge Rate from Inverter Rotary Compressor)

  • 신현석;변순석;태상진;문제명;김윤제
    • 한국유체기계학회 논문집
    • /
    • 제14권3호
    • /
    • pp.28-32
    • /
    • 2011
  • The inverter rotary compressor discharges refrigerant and compressor oil in air-conditioning systems. The compressor oil which discharged form compressor decreases the efficiency of heat exchanger and affects the compressor operation. Recently, several studies are in progress for reducing the compressor oil. Before the reduction of compressor oil discharge rate, the quantitative measurement and evaluation method are required. In order to cope with this requirement we have developed the measurement technic of oil discharge rate. The reliability assessment was carried out approximately 0.1% of the errors with compressor performance indicators. The acceptable errors were to ensure the reliability of measurement technic. In the experiment results at several conditions, The oil discharge rate of heating operation has been confirmed average 3.7 times more than cooling operation. In this study the evaluation method and the experimental results of oil discharge rate in air-conditioning systems are presented with various operating conditions.

로터리 압축기 저주파 특성에 관한 연구 (Study on Low Frequency Characteristics of Rotary Compressor)

  • 권병하;박신규;황인수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.857-862
    • /
    • 2002
  • Compressor is a major noise source of air-conditioner. Especially, its low frequency band noise below 1000Hz is very important because it will not be attenuated by passing through the cover panel and heat exchanger in air-conditioner. The factors affecting the low frequency band noise are studied by geometric similarity along with several experiments, and the low frequency noise is closely related with the discharge holes of muffler as well as the cavity of lower shell. The low frequency band noise is significantly reduced by proposed designs.

  • PDF

2톤/일 고정층 가스화기를 이용한 폐목재의 에너지 전환 연구 (The Study of Energy Conversion in a 2 Ton/day Waste-wood Fixed Bed Gasifier)

  • 이시훈;손영일;고창복;최경빈;김재호
    • 공업화학
    • /
    • 제20권4호
    • /
    • pp.391-395
    • /
    • 2009
  • 폐목재의 에너지 전환을 위하여 2톤/일 규모의 고정층 가스화기($0.9m{\times}2.4m$)를 제작하여 실험하였다. 고정층 가스화 설비는 3~5 cm의 목재칩을 이용하였으며 하부에는 회전식 스토커가 설치되어있다. 목재칩 연료 투입은 다단 나이프밸브 방식으로 되어 있으며 관성력 집진설비, 가스냉각용 열교환기, ID Fan 및 Cooling tower 등으로 구성되어져 있다. 가스화기는 $700{\sim}1000^{\circ}C$ 사이에서 조업하였으며 CO: 25~40 vol%, $H_2$: 7~12 vol%, $CH_4$: 2~4 vol%, $CO_2$: 12~24 vol%의 조성을 가지는 합성가스가 생성되었다. 합성가스 발열량은 $1100{\sim}1500kcal/Nm^3$으로 나타나 공업로의 적용이 가능하였다. 또한 합성가스의 가스 엔진을 통한 전력 생산도 가능하여 1~4 kW의 전력을 생산하였다.