• Title/Summary/Keyword: Rotary Pump

Search Result 66, Processing Time 0.031 seconds

Solubility Consideration in Performance Analysis of a $CO_2$ Twin Rotary Compressor (오일 용해도를 고려한 $CO_2$ 트윈 로타리 압축기 성능해석)

  • Kim, Woo-Young;Ahn, Jong-Min;Kim, Hyun-Jin;Cho, Sung-Oug
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.12
    • /
    • pp.842-849
    • /
    • 2007
  • For a $CO_2$ two-stage twin rotary compressor used for heat pump water heater system, changes of $CO_2$ solubility in PAG oil were investigated along the gas passages from the first stage suction to final discharge. Only slight changes in solubility took place in suction chambers for both of the first and second stages, but for compression chambers, solubility variation ranged from 0.115 to 0.136, and from 0.133 to 0.182, respectively for the first and second stages. Calculation of gas flashing in parts of leakage oil flows and of oil contained in control volumes due to solubility changes was conducted and included in gas pressure calculation. For the second stage, gas flashing amounts to around $5%\sim6%$ for most leakage flows. Cooling capacity, compressor input, and COP obtained by calculation were well compared to the experimental results. Effects of operation speed on the compressor performance was also studied: as the shaft speed increased, adiabatic efficiency decreased rapidly due to increased over-compression loss.

Performance Analysis of a $CO_2$ Two-Stage Twin Rotary Compressor ($CO_2$ 2단 트윈 로타리 압축기 성능해석)

  • Kim, Woo-Young;Ahn, Jong-Min;Kim, Hyun-Jin;Cho, Sung-Oug
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.19-27
    • /
    • 2007
  • Analytical investigation on the performance of a two stage twin rotary compressor for $CO_2$ heat pump water heater system has been carried out. A computer simulation program was made based on analytical models for gas compression in control volumes, leakages among neighboring volumes, and dynamics of moving elements of the compressor. Calculated cooling capacity, compressor input, and COP were well compared to those of experiments over the compressor speeds tested. For the operating condition of suction pressure of 3 MPa, and discharge pressure of 9 MPa, and compressor inlet temperature of $35^{\circ}C$, the compressor efficiency was calculated to be 80.2%: volumetric, adiabatic, and mechanical efficiencies were 88.3%, 93.2%, and 92.7%, respectively. For the present compressor model, volumetric and adiabatic efficiencies of the second stage cylinder were lower by about $6{\sim}7%$ than those of the first stage mainly due to the smaller discharge port at the second stage. Parametric study on the discharge port size showed that the compressor performance could be improved by 3.5% just by increasing the discharge port diameter by 20%.

Au 전극을 적용한 방사선 영상 검출기의 전기적 특성 평가

  • Song, Yong-Geun;O, Gyeong-Min;Kim, Seong-Heon;Kim, Ji-Na;No, Seong-Jin;Heo, Seung-Uk;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.365-365
    • /
    • 2012
  • 본 연구에서는 X-ray 영상을 얻기 위한 검출기 중 직접 검출방식에 쓰이고 있는 광도전체(Photoconductor)의 전극으로 Au를 사용하여 전기적인 특성을 파악하였다. Au는 유기물에 대한 반응이 적고 전기 전도도가 좋은 물질로서 투명전극으로 많이 쓰이고 있는 인듐 주석 산화물(ITO)을 대체할 수 있는 물질로 각광받고 있다. 우선 시편 제작을 위해 투명한 기판(Corning Glass, 0.7t)위에 하부전극으로 Au를 $3cm{\times}3cm$의 크기로 Physical Vapor Deposition(PVD) 방식을 이용하여 증착하였다. 이 때 챔버 내 저진공은 Rotary Pump를 이용하여 $3.9{\times}10-2Torr$ 이하를 유지하고 고진공은 Diffusion Pump를 이용하여 $5.3{\times}10-5Torr$ 이하를 유지하였다. 완성된 하부전극 위에 광도전체인 $HgI_2$를 폴리머 물질에 교반하여 메탈 폴리머 결합을 가진 Paste를 제조하고 이 Paste를 Screen Printing Method를 이용하여 증착 후 건조하였다. 마지막으로 시편위에 상부전극을 하부전극과 같은 조건으로 증착함으로서 시편을 완성한다. 상하부 전극으로 쓰이는 Au의 증착 조건을 변화시키면서 그에 따른 시편의 전기적인 특성 변화를 관찰하였다. 그 결과, Au의 증착온도와 질량에 따라 특성이 변화함을 알 수 있었다. 본 연구의 결과를 통해 디지털 방사선 검출기에서 Au 전극의 적용 가능성을 확인하였으며, 추후 Au 증착 조건의 최적화를 통해 방사선 검출기의 효율 향상을 위한 연구를 하고자 한다.

  • PDF

Finite Element Analysis of an Incremental Forming Process for Joining the Ball with the Socket of a Concave Piston Assembly (오목형 피스톤 조립체의 볼과 소켓의 체결을 위한 점진적 성형공정의 유한요소해석)

  • Lee, M.C.;Eom, J.G.;Joun, M.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.353-358
    • /
    • 2006
  • A three-dimensional finite element approach to process analysis and design for joining the socket with the ball by a kind of the rotary forging processes is presented in this paper. The rigid-plastic finite element method is employed and its results are used to reduce the number of process design tryouts. The approach is applied to developing a concave piston assembly for a high pressure hydraulic pump. Experiments show that the developed piston assembly satisfies the quality requirement on geometrical tolerance.

  • PDF

A study on the applications of firefighting equipment in use of Rotary Positive Displacement Pump (회전용적형펌프의 소방장비 적용에 관한 연구)

  • Kim, Yoo-Shik;Kno, Sung-Wang;Park, Jong-Won;Joo, Jong-Kil
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.71-75
    • /
    • 2011
  • 현재 소방장비에 적용되어지는 소방펌프를 살펴보면 원심펌프가 주류를 이루고 있으며 폼 약제 이송 장치와 같은 특수한 장비에 용적형펌프가 일부 사용되고 있다. 또한 국내 소방펌프의 형식승인 및 검정기술기준 또한 원심펌프 위주로 되어 있어 원심펌프 이외의 펌프를 소방장비에 적용하기에는 현실적으로 많은 어려움이 있는 실정이다. 따라서 본 연구는 고압으로 대유량 방수가 가능하도록 개발된 회전용적형펌프의 방수성능을 기존의 원심펌프와 비교 테스트하고 그 결과를 분석하여 회전용적형펌프의 소방장비에 적용 가능성을 제시하고자 한다.

  • PDF

Characteristic of sub-cooled nitrogen cryogenic system for 6.6kV/200A Inductive Superconducting Fault Current Limiter (6.6kV/200A급 유도형 한류기용 과냉질소 냉각시스템의 특성)

  • 박동근;강형구;윤경용;주민석;김태중;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.234-236
    • /
    • 2003
  • The cryogenic system for inductive superconducting fault current limiter (SFCL) has been investigated recently. In this investigation, the sub-cooled nitrogen cryogenic system was adopted to enhance the performance of DC reactor for 6.6㎸/200A inductive SFCL. In sub-cooled nitrogen state at 64K, the critical current value and the thermal conductivity are larger than those of saturated nitrogen state at 77K and the electrical insulation capacitance should be remarkably enhanced. The solenoid type of 84mH superconducting DC reactor was fabricated and cooled down to 64K by using sub-cooled cooling method with GM-cryocooler and rotary pump. The fabrication techniques of cryogenic system and some experimental results such as cooling down characteristic are introduced in this study. Moreover, the sub-cooled nitrogen cryogenic system was detailedly introduced in this paper.

  • PDF

A study on the characteristics of cast iron made by continuous cast iron for the parts of the rotary pump (진공 펌프용 부품에 적용한 연속 주조봉 주철의 특성연구)

  • 박상준
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.48-48
    • /
    • 2000
  • 진공부품에 사용되고 있는 재료는 여러 가지 있으나 회주철품은 진동 감쇄 및 흡진성이 우수하여 소음 발생이 적고, 조직 중에 흑연이 존재하므로 주강에 비하여 자기윤활작용이 있으며, 말차계수가 적어 마찰면의 면입이 높은 경우에도 소손 등의 이상 마멸현상이 적어 진공펌프, 내연기관, 공작 기계등과 같이 강인성과 내마멸성을 요구하는 부품에 많이 이용되어 왔다, 이 회주철도 대별하면 여러 종류가 있고, 진공 펌프용 재질은 주로 회주철 중에 ASTM A형으로 도면에 명기되어 있다. 따라서 본 제품을 개발하는 과정중에 연속 주조법으로 제조된 ASTM형이 기존의 재료에 비하여 내기밀성, 내마면성, 내피로성 및 기계적 성질등이 우수함을 확인하여본 재질로 개발하였고, 시험한 연구 결과를 발표하고자 한다. 실험은 ASTM A형으로 주조하기 위하여 용해된 용탕을 사형 주형에서 GC200으로 주조하고, ASTM D형은 D사의 연속 주조기에서 직경 30mm로 주조하였다. 이와 같이 주조된 사료를 일정한 크기로 시험편을 만들어 인장 강도, 경도, 피로한도, 피로성, 절삭성, 내유압성, 소입성과 내마멸성을 시험하였다.

  • PDF

Prediction of Hemolysis in Intra-Cardiac Axial Flow Blood Pumps for Optimization of the Impellers (심장 내 이식형 축류 혈액펌프의 임펠러 최적화를 위한 용혈량 예측)

  • Kim, Dong-Uk;Mitamura, Yoshinori
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.9
    • /
    • pp.431-437
    • /
    • 2002
  • Low hemolysis is one of the key factors in the production of successful rotary blood pumps. It is, however, difficult to identify the areas where hemolysis occurs. Computational fluid dynamics(CFD) analysis enables the engineer to predict hemolysis on a computer Fluid dynamics in five different axial flow pumps was analyzed 3-dimensionally using CFD software. The impeller was rotated at a speed which supplied a flow of 5L/min at a pressure difference of 100mmHg. Changes in the turbulent kinetic energy along streamlines through the pumps were computed. Reynolds' shear stress( (equation omitted) ) was calculated using the turbulent kinetic energy. Hemolysis was evaluated based on Reynolds'shear stress and its exposure time(t) : dHb/Hb=3.62$\times$10$^{-5}$ $t^{0.785}$$\tau$$^{2.416}$ . Hemolysis of the pumps was measured in vitro using fresh bovine blood to which citrate phosphate dextrose was added to prevent clotting. A pump flow of 5L/min was maintained at a pressure difference of 100mmHg for 3h. The normalized index of hemolysis(NIH) as measured. Reynolds' shear stress was high behind the impellers. The measured NIH and the calculated hemolysis(dHb/Hb) shoed a good correlation; NIH=0.0003(dHb/Hb) (r=0.90, n=6) in the range of NIH between 0.003 and 1.1. CFD analysis can predict the in vitro results of hemolysis as well as the areas where hemolysis occurs.ysis occurs.

Performance of Heat Pumps Charged with R170/R290 Mixture (R170/R290 혼합냉매 적용 히트펌프 성능 평가)

  • Park, Ki-Jung;Lee, Cheol-Hee;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.9
    • /
    • pp.590-598
    • /
    • 2008
  • In this study, performance of R170/R290 mixtures is measured on a heat pump bench tester in an attempt to substitute R22. The bench tester is equipped with a commercial hermetic rotary compressor providing a nominal capacity of 3.5kW. All tests are conducted under the summer cooling and winter heating conditions of $7/45^{\circ}C$ and $-7/41^{\circ}C$ in the evaporator and condenser respectively. During the tests, the composition of R170 is varied from 0 to 10% with an interval of 2%. Test results show that the coefficient of performance (COP) and capacity of R290 are up to 15.4% higher and 7.5% lower than those of R22 for both conditions respectively. For R170/R290 mixture, the COP decreases and the capacity increases with an increase in the amount of R170. The mixture of 4%R170/96%R290 shows the similar capacity and COP as those of R22. For the mixture, the compressor discharge temperature is $16{\sim}30^{\circ}C$ lower than that of R22. There is no problem with mineral oil since the mixture is mainly composed of hydrocarbons. The amount of charge is reduced up to 58% as compared to R22. Overall, R170/R290 mixture is a good long term 'drop-in' candidate to replace R22 in residential air-conditioners and heat pumps.

he deposition and analysis of ITO thin film by DC magnetron sputter at room temperature (DC 마그네트론 스펏터를 이용한 ITO 박막의 실온 증착 및 특성 분석)

  • Kim, Howoon;Yun, Jung-Oh
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.59-66
    • /
    • 2020
  • In this study, the characteristics of ITO thin film was investigated to finding a low cost and highly transparent electrodes for display of mobile communication devices. The ITO film was deposited by DC magnetron sputter. The experimental conditions were changed as follows: 1. ambient pressure changed 1 to 3 mTorr with 1mTorr step, 2. bias electric voltage changed with 10V step. The chamber was pumped out by rotary pump until 10-3Torr then the diffusion pump was used to lower the pressure of 10-6Torr. The results shows us the film growth was obvious when the bias voltage was larger than 300V, but the overall thickness tendency was existed: the more voltage is the thicker thickness. At 330V bias voltage condition, the deposition rate was the largest and apparent grain was showed.