• Title/Summary/Keyword: Rotary Motion

Search Result 261, Processing Time 0.025 seconds

Vibration characteristics of endodontic motors with different motion: reciprocation and conventional rotation (왕복운동 및 회전운동 근관성형용 전동모터 간의 진동 양상 비교)

  • Jeon, Yeong-Ju;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee;Chang, Hoon-Sang
    • The Journal of the Korean dental association
    • /
    • v.52 no.12
    • /
    • pp.734-743
    • /
    • 2014
  • Objectives: By introduced reciprocation motion file in dentistry, dentists benefit simple canal shaping procedure and time-saving. But, reciprocation motion generates uncomfortable vibration to doctors and patients. Because there was no study about this consideration, this study compared vibration pattern and power generated from reciprocation motion motor and conventional rotary motor. Materials & Methods: One conventional rotary motor; X-Smart (Dentsply Maillefer, Ballaigues, Switzerland); and two reciprocating motors; WaveOne Motor (Dentsply Maillefer, Ballaigues, Switzerland) and X-SMART PLUS (Dentsply Maillefer, Ballaigues, Switzerland); were used in this study. Triaxial $ICP^{(R)}$ Accelerometer (Model 356A12, PCB piezotronics, New York, USA) was attached on motor's handpiece head, and was measured tri-axial vibratory acceleration with NI Sound and Vibration Assistant 2009 software (National Instruments, Texas, USA). Mean vibratory acceleration and maximum vibratory acceleration was measured on fixed position and handed position. The results of vibratory acceleration were statistically analyzed using ANOVA and multiple comparisons are made using Turkey's test at p<0.05 level. Results: Reciprocating motors showed higher mean vibratory acceleration and maximum vibratory acceleration than conventional rotary motor (p<0.05). Between reciprocating motors, X-SMART PLUS had lower mean vibratory acceleration and maximum vibratory acceleration than WaveOne Motor (p<0.05). Conclusion: Reciprocating motors generate more vibration than conventional rotary motor. Further study about effect of vibration to dentist and patient is needed. And it seems to be necessary to make a standard about vibration level in endodontic motors.

Optimal Construction of Rotary-Linear Induction Motor (회전-리니어 병용 유도전동기의 특성해석)

  • Onuki, Takashi;Jeon, Woo-Jin;Tanabiki, Masamoto;Yoo, Ji-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.130-132
    • /
    • 1997
  • In this paper, we propose a new type of tubular linear induction motor(TLIM) with two-dimensional motion. The proposed motor consists of four short primary LIMs arranged on a same circumference and a common secondary. By adopting independently energized ring-windings to the primary, we can expect the reduction of coil-end region and the freedom of alternating current supply. The secondary conductor is capable of producing anyone of rotary, linear, and helical motions by controlling the phase of supply currents in each primary winding. From the 3-D finite element analysis and the experiment, we derive the feeding conditions to increase the subsidiary rotary-force and an optimal arrangement of primary currents to reduce the number of slot.

  • PDF

Simulation of Particle Beds with Combustion and Reduction in Steel Making Rotary Kilns (제철용 로터리 킬른 내의 연소 및 환원을 포함한 입자 거동 예측모사 해석)

  • Han, Woojoo;Jang, Kwonwoo;Han, Karam;Huh, Kang Y.
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.173-175
    • /
    • 2015
  • We simulate the particle bed motions with combustion and reduction in steel making rotary kilns. The particle bed motions are simulated by a Lagrangian approach called Discrete Phase Model (DPM). To reduce the number of tracking particles, the Coarse Grain Model (CGM) was applied. The model for particle motions showed good agreements with experimental results. In addition to the particle motion, the combustion and reduction simulation was performed. The combustion and reduction simulation can consider heat, mass and momentum transfer between the gas phase and particle beds.

  • PDF

Effect of adaptive motion on cyclic fatigue resistance of a nickel titanium instrument designed for retreatment

  • Ozyurek, Taha;Yilmaz, Koray;Uslu, Gulsah
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.1
    • /
    • pp.34-38
    • /
    • 2017
  • Objectives: The aim of this study was to evaluate the cyclic fatigue resistance of the ProTaper Universal D1 file (Dentsply Maillefer) under continuous and adaptive motion. Materials and Methods: Forty ProTaper Universal D1 files were included in this study. The cyclic fatigue tests were performed using a dynamic cyclic fatigue testing device, which had an artificial stainless steel canal with a $60^{\circ}$ angle of curvature and a 5 mm radius of curvature. The files were randomly divided into two groups (Group 1, Rotary motion; Group 2, Adaptive motion). The time to failure of the files were recorded in seconds. The number of cycles to failure (NCF) was calculated for each group. The data were statistically analyzed using Student's t-test. The statistical significant level was set at p < 0.05. Results: The cyclic fatigue resistance of the adaptive motion group was significantly higher than the rotary motion group (p < 0.05). Conclusion: Within the limitations of the present study, the 'Adaptive motion' significantly increased the resistance of the ProTaper Universal D1 file to cyclic facture.

Comparison vibration characteristics of several wireless endodontic handpieces (여러 근관치료용 무선 핸드피스의 진동양상 비교)

  • Lee, Bo-Kyung;Lee, Yoon;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.2
    • /
    • pp.81-89
    • /
    • 2022
  • Purpose: Wireless endodontic handpieces (WEH) are widely used in dental clinics due to their convenience and portability. This study aimed to compare the vibration magnitudes and patterns generated by five WEH. Materials and Methods: Vibration acceleration of five WEH (X-Smart IQ, E connect S, Endo A Class, ENDOIT, and TRAUS ENDO) in the rotary and reciprocating motion was measured with accelerometer The average vibration acceleration was analyzed using the t-test, Welch's ANOVA test, and Dunnett T3 test at P < 0.05. Results: In all WEH, the average vibration acceleration in reciprocating motion was significantly higher than that in rotary motion (P < 0.001). In rotary motion, repeated vibration graphs of constant amplitude were obtained without sudden changes in the magnitude of vibration, and the average vibration acceleration value was high in the order of X Smart IQ, Endo A Class, ENDOIT, E Connect S, and TRAUS ENDO (P < 0.001), there was no statistically significant difference between X Smart IQ and Endo A Class. In reciprocating motion, a vibration graph was obtained in which large amplitude peaks appear at specific points within one cycle are repeated. The average vibration acceleration value was highest in the order of X Smart IQ, E Connect S, Endo A class, ENDOIT, and TRAUS ENDO (P < 0.001). Conclusion: Regardless of the type of WEH, greater vibration occurred in the reciprocating motion than in the rotary motion (P < 0.001). In the reciprocating motion, there was a difference in vibration for all handpieces (P < 0.001).

A Study on the Torque Characteristics of Rotary Dampers (로터리 댐퍼의 토오크 특성에 관한 연구)

  • Lee, Choon Tae
    • Journal of Drive and Control
    • /
    • v.16 no.4
    • /
    • pp.87-92
    • /
    • 2019
  • Rotary dampers are damping devices which provide high resistance to shaft rotation. Rotary dampers are being used in various areas to enable the gentle opening and closing of the rotation motion relative to home furniture, industry machinery and automotive parts. Rotary dampers can be installed directly at the rotating point of a various part and can achieve uniform, gentle movement which increases quality and value of products. And generally, the silicone fluid is used as the damping medium because of its stable viscous properties. The movement of these little decelerators can be achieved with a high viscosity of working fluid and throttles installed in the body of the rotary damper. The damping force can be achieved clockwise, anti-clockwise or in both directions according to the structure of the orifices or throttles. In this paper, the torque performances of the rotary damper containing air in the working fluid were studied. For this purpose, the torque characteristic of the rotary damper according to the variation of various operating conditions such as clearance of leakage, dimensions of groove orifice, content ratio of air, etc., were simulated with AMEsim software.

Performance Enhancement of Motion Control Systems Through Friction Identification and Compensation (마찰력 식별과 보상을 통한 운동제어 시스템의 성능 개선)

  • Lee, Ho Seong;Jung, Sowon;Ryu, Seonghyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.6
    • /
    • pp.1-8
    • /
    • 2020
  • This paper proposes a method for measuring friction forces and creating a friction model for a rotary motion control system as well as an autonomous vehicle testbed. The friction forces versus the velocity were measured, and the viscous friction, Coulomb friction, and stiction were identified. With a nominal PID (proportional-integral-derivative) controller, we observed the adverse effects due to friction, such as excessive steady-state errors, oscillations, and limit-cycles. By adding an adequate friction model as part of the augmented nonlinear dynamics of a plant, we were able to conduct a simulation study of a motion control system that well matched experimental results. We have observed that the implementation of a model-based friction compensator improves the overall performance of both motion control systems, i.e., the rotary motion control system and the Altino testbed for autonomous vehicle development. By utilizing a better simulation tool with an embedded friction model, we expect that the overall development time and cost can be reduced.

Shaping Ability of Four Rotary Nickel-Titanium Instruments to Prepare Root Canal at Danger Zone (네 가지 전동 Ni-Ti 파일의 danger zone에서의 근관성형력)

  • Choi, Seok-Dong;Jin, Myoung-Uk;Kim, Ki-Ok;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.5
    • /
    • pp.446-453
    • /
    • 2004
  • The aim of this study was to evaluate the shaping abilities of four different rotary nickel-titanium instruments with anticurvature motion to prepare root canal at danger zone by measuring the change of dentin thickness in order to have techniques of safe preparation of canals with nickel-titanium files. Mesiobuccal and mesiolingual canals of forty mesial roots of extracted human lower molars were instrumented using the crown-down technique with ProFile, $GT^{TM}$ Rotary file, Quantec file and $ProTaper^{TM}$. In each root, one canal was prepared with a straight up-and-down motion and the other canal was with an anticurvature motion. Canals were instrumented until apical foramens were up to size of 30 by one operator. The muffle system was used to evaluate the root canal preparation. After superimposing the pre- and post-instrumentation canal. change in root dentin thickness was measured at the inner and outer sides of the canal at 1. 3, and 5 mm levels from the furcation. Data were analyzed using two-way ANOVA. Root dentin thickness at danger zone was significantly thinner than that at safe zone at all levels (p < 0.05). There was no significant difference in the change of root dentin thickness between the straight up-and-down and the anticurvature motions at both danger and safe zones in all groups (p > 0.05). ProTaper removed significantly more dentin than other files especially at furcal 3 mm level of danger and safe zones (p < 0.05) Therefore, it was concluded that anticurvature motion with nickel-titanium rotary instruments does not seem to be effective in danger zone of lower molars.

Design and Test of Vacuum Rotary Arc Gap Switch (Vacuum Rotary Arc Gap Switch의 설계 및 시험)

  • 서길수;황동원;이태호;황리호;김희진;이홍식;임근희
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.1
    • /
    • pp.19-24
    • /
    • 2003
  • Design and test results of a VRAG(Vacuum Rotary Arc Gap) switch were presented. To control the damage of electrodes caused by the vacuum arc, Lorentz's force by the radial magnetic field between spiral electrodes was used to rotate the vacuum uc. VRAG switch electrodes were made of the material of CuCr and OFHC. Gap distance between two spiral type electrodes for the rotation of the arc discharge is 8, 10, 12mm. In the cathode, one trigger electrode was inserted into each spiral wing. Normal operation of the VRAG switch was confirmed with 10.6[$mutextrm{s}$]of trigger delay and 2~3[$mutextrm{s}$] of the jitter time. The speed of the vacuum arc was measured to be 0.6 ~ 1[km/s] by a motion analyzer.